Abstract:
:This article investigates whether prediction of subject-specific physiological data is viable through an individualised computational model of a cochlear implant. Subject-specific predictions could be particularly useful to assess and quantify the peripheral factors that cause inter-subject variations in perception. The results of such model predictions could potentially be translated to clinical application through optimisation of mapping parameters for individual users, since parameters that affect perception would be reflected in the model structure and parameters. A method to create a subject-specific computational model of a guinea pig with a cochlear implant is presented. The objectives of the study are to develop a method to construct subject-specific models considering translation of the method to in vivo human models and to assess the effectiveness of subject-specific models to predict peripheral neural excitation on subject level. Neural excitation patterns predicted by the model are compared with single-fibre electrically evoked auditory brainstem responses obtained from the inferior colliculus in the same animal. Results indicate that the model can predict threshold frequency location, spatial spread of bipolar and tripolar stimulation and electrode thresholds relative to one another where electrodes are located in different cochlear structures. Absolute thresholds and spatial spread using monopolar stimulation are not predicted accurately. Improvements to the model should address this.
journal_name
Med Eng Physjournal_title
Medical engineering & physicsauthors
Malherbe TK,Hanekom T,Hanekom JJdoi
10.1016/j.medengphy.2012.09.001subject
Has Abstractpub_date
2013-07-01 00:00:00pages
926-36issue
7eissn
1350-4533issn
1873-4030pii
S1350-4533(12)00251-2journal_volume
35pub_type
杂志文章abstract::We present a finite element based simulation and analysis method to describe the spatial extent of stimulation and the effects of electrode-tissue interactions in subretinal prostheses. In particular, we estimate the threshold stimulation current needed to depolarise and evoke action potentials in the ganglion cells t...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.01.015
更新日期:2011-07-01 00:00:00
abstract::Total hip arthroplasty (THA) broaching involves impacting a broach handle with a mallet, facilitating force transmission to progress broaches into the femoral medullary canal. Limited surgical access during direct anterior THAs increases off-axis forces, potentially contributing to tissue damage. The aim was to charac...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.12.004
更新日期:2020-02-01 00:00:00
abstract::Medical imaging and clinical studies have proven that the heart pumps by means of minor outer volume changes and back-and-forth longitudinal movements in the atrioventricular (AV) region. The magnitude of AV-plane displacement has also shown to be a reliable index for diagnosis of heart failure. Despite this, AV-plane...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.11.002
更新日期:2015-01-01 00:00:00
abstract::Middle cerebral arterial blood velocity (MCAv) response to spontaneous and manipulated changes of arterial blood pressure (ABP) was studied in eight subjects using a linear autoregressive with exogenous input (ARX) model. ABP and MCAv were measured non-invasively by photoplethysmograph and transcranial Doppler ultraso...
journal_title:Medical engineering & physics
pub_type: 临床试验,杂志文章
doi:10.1016/s1350-4533(03)00015-8
更新日期:2003-10-01 00:00:00
abstract::Bone defects can occur in various forms and present challenges to performing a standard micro-CT evaluation of bone quality because most measures are suited to homogeneous structures rather than ones with spatially focal abnormalities. Such defects are commonly associated with pain and fragility. Research involving bo...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2013.05.016
更新日期:2013-11-01 00:00:00
abstract::Tripolar systems have been implanted to reduce the risk of recurrent dislocation. However, there is little known about the dynamic behavior of tripolar hip endoprostheses under daily life conditions and achieved joint stability. Hence, the objective of this biomechanical study was to examine the in vivo dynamics and d...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2013.09.007
更新日期:2014-01-01 00:00:00
abstract::The deformation of soft tissue compromises the accuracy of image-guided surgery based on preoperative images, and restricts its applicability to surgery on or near bony structures. One way to overcome these limitations is to combine biomechanical models with sparse intraoperative data, in order to realistically warp t...
journal_title:Medical engineering & physics
pub_type: 杂志文章,评审
doi:10.1016/j.medengphy.2005.10.005
更新日期:2005-12-01 00:00:00
abstract::We observed an anomaly in the human electroencephalogram (EEG) associated with exposure to terrestrial trunked radio (TETRA) Radiofrequency Fields (RF). Here, we characterize the time and frequency components of the anomaly and demonstrate that it is an artefact caused by TETRA RF interfering with the EEG recording eq...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2013.04.009
更新日期:2013-11-01 00:00:00
abstract::Interest in patient-specific blood-flow circulation modeling has increased substantially in recent years. The availability of clinical data for geometric and elastic properties together with efficient numerical methods has now made model rendering feasible. This work uses 3-D fluid-structure interaction (FSI) to provi...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2012.08.009
更新日期:2013-06-01 00:00:00
abstract::Foot pressure ulcers are a common complication of diabetes because of patient's lack of sensitivity due to neuropathy. Deep pressure ulcers appear internally when pressures applied on the foot create high internal strains nearby bony structures. Monitoring tissue strains in persons with diabetes is therefore important...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.04.017
更新日期:2016-09-01 00:00:00
abstract::Gastric contractions play an important role in the digestive process of the stomach. The established method for the measurement of gastric contractions is invasive and involves the insertion through the nose of a manometric probe into the stomach. A non-invasive method is introduced in this paper for the identificatio...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(95)95713-k
更新日期:1995-04-01 00:00:00
abstract::In this study, we propose a new classification method for early differentiation of paroxysmal and persistent atrial fibrillation episodes, i.e. those which spontaneously or with external intervention will return to sinus rhythm within 7 days of onset from the ones where the arrhythmia is sustained for more than 7 days...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.10.013
更新日期:2017-01-01 00:00:00
abstract::In recent years, a combination of traction and vibration therapy is usually used to alleviate low back pain (LBP) in clinical settings. Combining head-down tilt (HDT) traction with vibration was demonstrated to be efficacious for LBP patients in our previous study. However, the biomechanics of the lumbar spine during ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.10.004
更新日期:2017-01-01 00:00:00
abstract::The purpose of this study was to determine the use and feasibility of accelerometry-based monitoring and to examine a discrete multi-resolution signal analysis technique to determine motoric subtypes in patients with DSM-IV delirium. Forty consecutive patients receiving palliative care (23 male, 17 female, mean age+/-...
journal_title:Medical engineering & physics
pub_type: 临床试验,杂志文章
doi:10.1016/j.medengphy.2009.10.012
更新日期:2010-03-01 00:00:00
abstract::The thermal conductivity of cortical bone was characterized experimentally. Specimens were taken from the mid-diaphysis of bovine femora, and the rate of heat transfer was measured in three orthogonal directions. The conductivity was found to be 0.58+/-0.018 W/mK in the longitudinal direction, 0.53+/-0.030 W/mK in the...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(01)00003-0
更新日期:2000-12-01 00:00:00
abstract::Budd-Chiari syndrome (BCS) is a rare liver disease characterised by the obstruction of draining hepatic veins, and subsequent reduced blood return to the heart. Although many clinical BCS studies have been reported, few studies have quantified the associated changes that occur in the entire hepatic circulation. In thi...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.04.010
更新日期:2019-07-01 00:00:00
abstract::Kinematic parameters for 10 normal subjects and 10 patients with ankle arthrodesis are grouped using the fuzzy cluster paradigm. The features chosen for clustering are Euler angles of the sagittal plane in the hindfoot, the forefoot and combined hindfoot and forefoot joints. Gait patterns are identified using informat...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(01)00020-0
更新日期:2001-03-01 00:00:00
abstract::Using an anaesthetized cat's central footpad pressed against an object as the model of a paralyzed human hand, a nerve signal recording system was developed to measure the effect of a group of consecutive slips between the footpad and the object. Electroneurographic (ENG) activity was recorded using a cuff electrode i...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2007.05.007
更新日期:2008-05-01 00:00:00
abstract::A DNA electrochemical biosensor is an integrated receptor-transducer device. The most important step in the development and manufacture of a sensitive DNA-biosensor for the detection of DNA-drug interactions is the immobilization procedure of the nucleic acid probe on the transducer surface. Magnetic A/C Mode atomic f...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2006.05.009
更新日期:2006-12-01 00:00:00
abstract::The presented research positively evaluates the vocality of the cough sound by estimating the global cough fundamental frequency or pitch. The fundamental frequency was determined by autocorrelation analysis on both the original time-signal and the linear predicted time-signal. The experimental cough database was regi...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(02)00055-3
更新日期:2002-09-01 00:00:00
abstract::Lateral epicondylitis (LE) is hypothesized to occur as a result of repetitive, strenuous and abnormal postural activities of the elbow and wrist. There is still a lack of understanding of how wrist and forearm positions contribute to this condition during common manual tasks. In this study the wrist kinematics and the...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.02.002
更新日期:2011-07-01 00:00:00
abstract::A method for assessment and second-order polynomial detrending of signals containing periodic components is proposed. The analytically derived properties of this method are validated with synthesized signals, processed by the computational procedure developed. It is shown that, in addition to accurate detrending, the ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(98)00077-0
更新日期:1998-11-01 00:00:00
abstract::This paper describes the application of probabilistic design methods to the analysis of the behaviour of an uncemented total hip replacement femoral component implanted in a proximal femur. Probabilistic methods allow variations in factors which control the behaviour of the implanted femur (the input parameters) to be...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2009.01.002
更新日期:2009-05-01 00:00:00
abstract::The objective of this work is to develop a robust method for human abdominal aortic aneurysm (AAA) centerline detection that can contribute to the accurate computation of features for the prediction of AAA rupture risk. A semiautomatic algorithm is proposed for detecting the lumen centerline in contrast-enhanced abdom...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2013.03.005
更新日期:2013-09-01 00:00:00
abstract::The aim of this study is to develop a technical quality evaluation system of electroencephalogram (EEG) recording in order to acquire technically satisfactory EEG records, which may contribute to the accuracy improvement of EEG interpretation. In our developed system, the evaluation of EEG recording comprises the dete...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2004.09.001
更新日期:2005-01-01 00:00:00
abstract::The rehabilitation engineering community is working towards the development of robotic devices that can assist during gait training of patients suffering from neurologic injuries such as stroke and spinal cord injuries (SCI). The field of robot assisted treadmill training has rapidly evolved during the last decade. Th...
journal_title:Medical engineering & physics
pub_type: 杂志文章,评审
doi:10.1016/j.medengphy.2010.12.010
更新日期:2011-06-01 00:00:00
abstract::An 'instantaneous' optimal filter is presented for improving the signal-to-noise ratio in averaged electrocardiograms (ECGs). The filter design is based on a simple model that accounts for correlation across the ensemble of beats but ignores correlation in time. Another property of the model is that the noise level is...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(96)00069-0
更新日期:1997-04-01 00:00:00
abstract:BACKGROUND:An ideal prosthetic mesh for incisional hernia repair should mimic the anisotropic compliance of the abdominal wall, and at lower loads should exhibit higher distensibility without impairment of safety at higher loads. This study evaluated the biomechanical properties of six meshes in a rabbit model. METHOD...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.09.022
更新日期:2012-09-01 00:00:00
abstract::Tripolar nerve cuff electrodes have been widely used for measuring peripheral nerve activity. However, despite the high signal-to-noise ratio levels that can be achieved with this recording configuration, the clinical use of cuff electrodes in closed-loop controlled neuroprostheses remains limited. This is largely att...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.11.010
更新日期:2017-02-01 00:00:00
abstract::Patients affected by motor disorders of the hand and having residual voluntary movements of fingers or wrist can benefit from self-rehabilitation exercises performed with so-called dynamic hand splints. These systems consist of orthoses equipped with elastic cords or springs, which either provide a sustained stretch o...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2013.10.015
更新日期:2014-02-01 00:00:00