Wear of polyethylene cups in total hip arthroplasty: a parametric mathematical model.

Abstract:

:This paper presents a parametric mathematical model of the head-cup wear coupling in total hip arthroplasty (THA). The model evaluates the dependence of acetabular volumetric wear upon the characteristic parameters of patient and hip prosthesis. Archard's law is assumed to calculate the wear coupling behaviour. The wear factor is taken from pin-on-disc wear tests as a function of materials and finishing of the articular joint. The forces acting on the hip joint are taken from experimental data found in the literature whilst the load distribution is calculated under the hypotheses of perfectly rigid ideal wear coupling. The sliding distance is obtained by combining the three elementary displacements -- due to rotations around the three axes -- at the generic bearing surface location. The simulations show that the polymeric wear volume per step cycle decreases ranging from fast walking speeds to low running speeds, it increases linearly with patient body weight and with femoral head diameter, it decreases slightly for positive variations of the socket inclination angle and it increases exponentially with femoral head roughness. The volumetric wear rate per year calculated for a standard reference patient is 5.8 mm3. The relevant iso-wear maps show a marginal pattern with the maximum located near the cup superior borderline. At the instant of peak load, the iso-stress maps show a paracentral pattern with the maximum superior to the cup polar point, and the iso-sliding distance maps show a marginal pattern with two maxima located near the cup's superior and inferior borderlines.

journal_name

Med Eng Phys

authors

Pietrabissa R,Raimondi M,Di Martino E

doi

10.1016/s1350-4533(98)00004-6

subject

Has Abstract

pub_date

1998-04-01 00:00:00

pages

199-210

issue

3

eissn

1350-4533

issn

1873-4030

pii

S1350453398000046

journal_volume

20

pub_type

杂志文章
  • Micro-CT evaluation of bone defects: applications to osteolytic bone metastases, bone cysts, and fracture.

    abstract::Bone defects can occur in various forms and present challenges to performing a standard micro-CT evaluation of bone quality because most measures are suited to homogeneous structures rather than ones with spatially focal abnormalities. Such defects are commonly associated with pain and fragility. Research involving bo...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.05.016

    authors: Buie HR,Bosma NA,Downey CM,Jirik FR,Boyd SK

    更新日期:2013-11-01 00:00:00

  • Study on gastric interdigestive pressure activity based on phase space reconstruction and FastICA algorithm.

    abstract::To investigate the features of the gastric interdigestive pressure activity under normal physiological conditions, we have developed the wireless radiotelemetry capsule based on a telemetry technique. Twelve healthy volunteers participated in this study. Pressure activity data which are an important index of gastric m...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.04.017

    authors: Huang B,Yan G,Zan P,Li Q

    更新日期:2009-04-01 00:00:00

  • Electroactive polymeric sensors in hand prostheses: bending response of an ionic polymer metal composite.

    abstract::In stark contrast to the inspiring functionality of the natural hand, limitations of current upper limb prostheses stemming from marginal feedback control, challenges of mechanical design, and lack of sensory capacity, are well-established. This paper provides a critical review of current sensory systems and the poten...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.09.009

    authors: Biddiss E,Chau T

    更新日期:2006-07-01 00:00:00

  • Assessment of body composition in adolescent subjects with anorexia nervosa by bioimpedance.

    abstract::Our main goal was to test various impedance methods for measuring body composition in adolescents with anorexia nervosa (AN) during refeeding therapy. A specific objective was to compare the information provided by a foot-to-foot impedancemeter (FFI) with that supplied by a medical multifrequency impedancemeter and by...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.09.005

    authors: Moreno MV,Djeddi DD,Jaffrin MY

    更新日期:2008-07-01 00:00:00

  • Functional evaluation of natural sensory feedback incorporated in a hand grasp neuroprosthesis.

    abstract::We investigated whether automatic control of a hand grasp neuroprosthesis by means of signals from natural sensors in the skin of the index finger can mimic the natural control of grasp force in an important task of daily living, namely eating. We designed a simulated eating task with the same ratio of rest and activi...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2004.03.002

    authors: Inmann A,Haugland M

    更新日期:2004-07-01 00:00:00

  • Development and validation of an improved mechanical thorax for simulating cardiopulmonary resuscitation with adjustable chest stiffness and simulated blood flow.

    abstract::Investigations of compressive frequency, duty cycle, or waveform during CPR are typically rooted in animal research or computer simulations. Our goal was to generate a mechanical model incorporating alternate stiffness settings and an integrated blood flow system, enabling defined, reproducible comparisons of CPR effi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.02.005

    authors: Eichhorn S,Spindler J,Polski M,Mendoza A,Schreiber U,Heller M,Deutsch MA,Braun C,Lange R,Krane M

    更新日期:2017-05-01 00:00:00

  • Nintendo® Wii Fit based sleepiness tester detects impairment of postural steadiness due to 24 h of wakefulness.

    abstract::A field-usable sleepiness tester could reduce sleepiness related accidents. 15 subjects' postural steadiness was measured with a Nintendo(®) Wii Fit balance board every hour for 24 h. Body sway was quantified with complexity index, CI, and the correlation between CI and alertness predicted by a three-process model of ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.08.007

    authors: Tietäväinen A,Gates FK,Meriläinen A,Mandel JE,Hæggström E

    更新日期:2013-12-01 00:00:00

  • Validation of computerized square-drawing based evaluation of motor function in patients with stroke.

    abstract::Human-administered clinical scales are commonly used for quantifying motor performance and determining the course of therapy in post-stroke individuals. Computerized methods aim to improve consistency, resolution and duration of patients' evaluation. The objective of this study was to test the validity of computerized...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.06.001

    authors: Isaković MS,Savić AM,Konstantinović LM,Popović MB

    更新日期:2019-09-01 00:00:00

  • Fluid pressure driven fibril reinforcement in creep and relaxation tests of articular cartilage.

    abstract::Biological tissues exhibit diverse mechanical behaviors because of complex material properties. As has been shown for ligaments and intervertebral discs, mathematical models often appear to well predict load responses individually by adjusting model parameters, but likely fail to describe several different load respon...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.03.001

    authors: Li LP,Korhonen RK,Iivarinen J,Jurvelin JS,Herzog W

    更新日期:2008-03-01 00:00:00

  • Baseline drift removal and denoising of MCG data using EEMD: role of noise amplitude and the thresholding effect.

    abstract::We adopt the Ensemble Empirical Mode Decomposition (EEMD) method, with an appropriate thresholding on the Intrinsic Mode Functions (IMFs), to denoise the magnetocardiography (MCG) signal. To this end, we discuss the two associated problems that relate to: (i) the amplitude of noise added to the observed signal in the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.06.023

    authors: Mariyappa N,Sengottuvel S,Parasakthi C,Gireesan K,Janawadkar MP,Radhakrishnan TS,Sundar CS

    更新日期:2014-10-01 00:00:00

  • Bi-directional flow sensor with a wide dynamic range for medical applications.

    abstract::This paper describes a novel three-wire thermal flow sensor for medical applications. The present innovation for low-frequency measurements involves the use of a pulsed-wire anemometer with a comparatively large wire diameter (12.5 microm and larger) together with a novel signal processing approach. A small wire is he...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.06.002

    authors: Al-Salaymeh A,Jovanović J,Durst F

    更新日期:2004-10-01 00:00:00

  • Hemodynamic aspects of the Budd-Chiari syndrome of the liver: A computational model study.

    abstract::Budd-Chiari syndrome (BCS) is a rare liver disease characterised by the obstruction of draining hepatic veins, and subsequent reduced blood return to the heart. Although many clinical BCS studies have been reported, few studies have quantified the associated changes that occur in the entire hepatic circulation. In thi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.04.010

    authors: Ho H,Qiu C

    更新日期:2019-07-01 00:00:00

  • Effect of longitudinal anatomical mismatch of stenting on the mechanical environment in human carotid artery with atherosclerotic plaques.

    abstract::Longitudinal anatomic mismatch (LAM) of stenting (i.e., a stenotic artery segment is not fully covered by a deployed stent) worsens the mechanical environment in the treated artery, which most likely is the cause for the associated high risks of restenosis, myocardial infarction and stent thrombosis. To probe the poss...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.06.010

    authors: Fan Z,Liu X,Sun A,Zhang N,Fan Z,Fan Y,Deng X

    更新日期:2017-10-01 00:00:00

  • Acoustic power measurement of high-intensity focused ultrasound transducer using a pressure sensor.

    abstract::The acoustic power of high-intensity focused ultrasound (HIFU) is an important parameter that should be measured prior to each treatment to guarantee effective and safe outcomes. A new calibration technique was developed that involves estimating the pressure distribution, calculating the acoustic power using an underw...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.01.014

    authors: Zhou Y

    更新日期:2015-03-01 00:00:00

  • Use of charged membranes to control interference by body chemicals in a glucose biosensor.

    abstract::The prerequisite for the continuous in vivo monitoring of glucose concentration is the development of an implantable glucose sensor with long-term stability. A new enzyme electrode concept featuring fluid-state glucose oxidase modified carbon powder along with a cross-linked glucose oxidase enzyme layer has been devel...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(90)90008-v

    authors: Vaidya R,Wilkins E

    更新日期:1994-09-01 00:00:00

  • Gabor frames for classification of paroxysmal and persistent atrial fibrillation episodes.

    abstract::In this study, we propose a new classification method for early differentiation of paroxysmal and persistent atrial fibrillation episodes, i.e. those which spontaneously or with external intervention will return to sinus rhythm within 7 days of onset from the ones where the arrhythmia is sustained for more than 7 days...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.10.013

    authors: Ortigosa N,Galbis A,Fernández C,Cano Ó

    更新日期:2017-01-01 00:00:00

  • Technical quality evaluation of EEG recording based on electroencephalographers' knowledge.

    abstract::The aim of this study is to develop a technical quality evaluation system of electroencephalogram (EEG) recording in order to acquire technically satisfactory EEG records, which may contribute to the accuracy improvement of EEG interpretation. In our developed system, the evaluation of EEG recording comprises the dete...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.09.001

    authors: Nakamura M,Chen Q,Sugi T,Ikeda A,Shibasaki H

    更新日期:2005-01-01 00:00:00

  • Quantitative characterisation of impaction events during femoral broaching in total hip arthroplasty.

    abstract::Total hip arthroplasty (THA) broaching involves impacting a broach handle with a mallet, facilitating force transmission to progress broaches into the femoral medullary canal. Limited surgical access during direct anterior THAs increases off-axis forces, potentially contributing to tissue damage. The aim was to charac...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.12.004

    authors: Preutenborbeck M,Reuter J,Ferrari E

    更新日期:2020-02-01 00:00:00

  • Application of soft tissue modelling to image-guided surgery.

    abstract::The deformation of soft tissue compromises the accuracy of image-guided surgery based on preoperative images, and restricts its applicability to surgery on or near bony structures. One way to overcome these limitations is to combine biomechanical models with sparse intraoperative data, in order to realistically warp t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2005.10.005

    authors: Carter TJ,Sermesant M,Cash DM,Barratt DC,Tanner C,Hawkes DJ

    更新日期:2005-12-01 00:00:00

  • Biomechanical and histological evaluation of abdominal wall compliance with intraperitoneal onlay mesh implants in rabbits: a comparison of six different state-of-the-art meshes.

    abstract:BACKGROUND:An ideal prosthetic mesh for incisional hernia repair should mimic the anisotropic compliance of the abdominal wall, and at lower loads should exhibit higher distensibility without impairment of safety at higher loads. This study evaluated the biomechanical properties of six meshes in a rabbit model. METHOD...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.09.022

    authors: Konerding MA,Chantereau P,Delventhal V,Holste JL,Ackermann M

    更新日期:2012-09-01 00:00:00

  • Human body model response to mechanical impulse.

    abstract::Despite our understanding of the importance of falling, previous studies have ignored the effects of falls from standing height. In this article, lumped parameter linear and nonlinear models of a standing human have been used to simulate the impact response of the body segments due to inputs at the shoes. The accelera...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00081-1

    authors: Jarrah M,Qassem W,Othman M,Gdeisat M

    更新日期:1997-06-01 00:00:00

  • Motion quality evaluation of upper limb target-reaching movements.

    abstract::Fitts' Law was extended in the polar coordinate system, and a set of indices for human motion evaluation is proposed. In this paper, the index of difficulty and the index of performance are introduced as the general indices for the quality measure of plane target-to-target movement. As an example, the target-reaching ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00121-7

    authors: Yang N,Zhang M,Huang C,Jin D

    更新日期:2002-03-01 00:00:00

  • Validation of three-dimensional model-based tibio-femoral tracking during running.

    abstract::The purpose of this study was to determine the accuracy of a radiographic model-based tracking technique that measures the three-dimensional in vivo motion of the tibio-femoral joint during running. Tantalum beads were implanted into the femur and tibia of three subjects and computed tomography (CT) scans were acquire...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2008.03.003

    authors: Anderst W,Zauel R,Bishop J,Demps E,Tashman S

    更新日期:2009-01-01 00:00:00

  • Number and localization of the implants for the fixed prosthetic reconstructions: on the strain in the anterior maxillary region.

    abstract::Resorption following tooth loss and poor bone quality affect the success of implants in the anterior maxilla. Inappropriate planning can cause implant loss and aesthetics problems that are difficult to resolve. There is a limited literature on the optimum number and location of implants in anterior maxilla for fabrica...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.02.004

    authors: Bölükbaşı N,Yeniyol S

    更新日期:2015-04-01 00:00:00

  • Influence of antegrade pulmonary blood flow on the hemodynamic performance of bidirectional cavopulmonary anastomosis: a numerical study.

    abstract::The role and effect of preserved antegrade pulmonary blood flow (APBF) at the time of bidirectional cavopulmonary anastomosis (BCPA) in the management of single-ventricle physiology is controversial. We investigated the influence of APBF on the fluid dynamics of BCPA connection using computational fluid dynamics (CFD)...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.07.004

    authors: Sun Q,Wan D,Liu J,Liu Y,Zhu M,Hong H,Sun Y,Wang Q

    更新日期:2009-03-01 00:00:00

  • Motor unit firing rates and synchronisation affect the fractal dimension of simulated surface electromyogram during isometric/isotonic contraction of vastus lateralis muscle.

    abstract::During fatiguing contractions, many adjustments in motor units behaviour occur: decrease in muscle fibre conduction velocity; increase in motor units synchronisation; modulation of motor units firing rate; increase in variability of motor units inter-spike interval. We simulated the influence of all these adjustments ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.09.022

    authors: Mesin L,Dardanello D,Rainoldi A,Boccia G

    更新日期:2016-12-01 00:00:00

  • Mechanical characterization of bone anchors used with a bone-attached, parallel robot for skull surgery.

    abstract::Bone-attached robots and microstereotactic frames, intended for deep brain stimulation and minimally invasive cochlear implantation, typically attach to a patient's skull via bone anchors. A rigid and reliable link between such devices and the skull is mandatory in order to fulfill the high accuracy demands of minimal...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.02.012

    authors: Kobler JP,Prielozny L,Lexow GJ,Rau TS,Majdani O,Ortmaier T

    更新日期:2015-05-01 00:00:00

  • Development and validation of a robotic system for ankle joint testing.

    abstract::Ankle sprains are the most common sports injury. Gaining a better understanding of ankle mechanics will help improve current treatments, enabling a better quality of life for patients following surgery. In this paper, the development of a robotic system for ankle joint testing is presented. It is composed of an indust...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.10.002

    authors: El Daou H,Calder JD,Stephen JM

    更新日期:2018-12-01 00:00:00

  • Mechanical testing and modelling of the Universal 2 implant.

    abstract::Understanding the load mechanics of orthopaedic implants is important to be able to predict their behaviour in-vivo. Much research, both mechanical and clinical, has been carried out on hip and knee implants, but less has been written about the mechanics of wrist implants. In this paper, the load mechanics of the Univ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.02.008

    authors: Gislason MK,Foster E,Main D,Fusiek G,Niewczas P,Bransby-Zachary M,Nash DH

    更新日期:2016-06-01 00:00:00

  • Investigation to predict patellar tendon reflex using motion analysis technique.

    abstract::The investigation of patellar tendon reflex involves development of a reflex hammer holder, kinematic data collection and analysis of patellar reflex responses using motion analysis techniques. The main aim of this research is to explore alternative means of assessing reflexes as a part of routine clinical diagnosis. ...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2010.11.002

    authors: Tham LK,Osman NA,Lim KS,Pingguan-Murphy B,Abas WA,Zain NM

    更新日期:2011-05-01 00:00:00