Influence of antegrade pulmonary blood flow on the hemodynamic performance of bidirectional cavopulmonary anastomosis: a numerical study.

Abstract:

:The role and effect of preserved antegrade pulmonary blood flow (APBF) at the time of bidirectional cavopulmonary anastomosis (BCPA) in the management of single-ventricle physiology is controversial. We investigated the influence of APBF on the fluid dynamics of BCPA connection using computational fluid dynamics (CFD). Patient-specific, three-dimensional geometry of a BCPA connection with native pulmonary artery (PA) trunk was reconstructed and transient CFD simulations were done at four predetermined mean flow rates of PA trunk (0.5L/min, 1L/min, 1.5L/min and 2L/min). During a cardiac cycle, the flow ratio of left pulmonary artery (LPA)/right pulmonary artery (RPA) increased from 1.91 to 2.50, and average control volume power loss increased from 0.76 mW to 18.05 mW when the mean flow rate of PA trunk changed from 0.5L/min to 2L/min. The pulsatility of pressures in LPA, RPA and superior vena cava became more prominent as the amount of APBF increased. Local fluid structures in the connection area at four levels of APBF differed from each other.

journal_name

Med Eng Phys

authors

Sun Q,Wan D,Liu J,Liu Y,Zhu M,Hong H,Sun Y,Wang Q

doi

10.1016/j.medengphy.2008.07.004

subject

Has Abstract

pub_date

2009-03-01 00:00:00

pages

227-33

issue

2

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(08)00129-X

journal_volume

31

pub_type

杂志文章
  • Minimization of the knee shear joint load in leg-extension equipment.

    abstract::We developed an analytical biomechanical model for leg-extension equipment and the associated knee-extension/flexion exercises. The shear component, phi(t), of the tibiofemoral joint load was calculated taking into account all the fundamental elements of the equipment mechanics (resistance pad placement, cam/pulley sy...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.12.012

    authors: Biscarini A

    更新日期:2008-10-01 00:00:00

  • Dynamic properties of human incudostapedial joint-Experimental measurement and finite element modeling.

    abstract::The incudostapedial joint (ISJ) is a synovial joint connecting the incus and stapes in the middle ear. Mechanical properties of the ISJ directly affect sound transmission from the tympanic membrane to the cochlea. However, how ISJ properties change with frequency has not been investigated. In this paper, we report the...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.02.006

    authors: Jiang S,Gan RZ

    更新日期:2018-04-01 00:00:00

  • New product development processes within the UK medical device industry.

    abstract::This paper reports on the findings of an extensive survey investigating practising design engineers' perceptions of new product development within the UK medical device industry. The design activity recorded was predominantly the small-scale development of low volume products. Explicit formal procedures were rarely us...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00021-5

    authors: Glen JM,Lord M

    更新日期:1996-12-01 00:00:00

  • Personalized 3D reconstruction of the rib cage for clinical assessment of trunk deformities.

    abstract::Scoliosis is a 3D deformity of the spine and rib cage. Extensive validation of 3D reconstruction methods of the spine from biplanar radiography has already been published. In this article, we propose a novel method to reconstruct the rib cage, using the same biplanar views as for the 3D reconstruction of the spine, to...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.06.002

    authors: Grenier S,Parent S,Cheriet F

    更新日期:2013-11-01 00:00:00

  • A decentralized adaptive fuzzy robust strategy for control of upright standing posture in paraplegia using functional electrical stimulation.

    abstract::In this paper, we present a novel decentralized robust methodology for control of quiet upright posture during arm-free paraplegic standing using functional electrical stimulation (FES). Each muscle-joint complex is considered as a subsystem and individual controllers are designed for each one. Each controller operate...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.06.013

    authors: Kobravi HR,Erfanian A

    更新日期:2012-01-01 00:00:00

  • Human body model response to mechanical impulse.

    abstract::Despite our understanding of the importance of falling, previous studies have ignored the effects of falls from standing height. In this article, lumped parameter linear and nonlinear models of a standing human have been used to simulate the impact response of the body segments due to inputs at the shoes. The accelera...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00081-1

    authors: Jarrah M,Qassem W,Othman M,Gdeisat M

    更新日期:1997-06-01 00:00:00

  • Effect of specimen length: are the mechanics of individual motion segments comparable in functional spinal units and multisegment specimens?

    abstract::Functional spinal units (FSUs) are frequently used for in vitro mechanical testing. This approach assumes that the mechanical behavior of the FSUs is equivalent to the mechanics of these segments within the intact spine. The purpose of this study was to determine whether normal spinal mechanics are compromised in FSU ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00152-2

    authors: Dickey JP,Kerr DJ

    更新日期:2003-04-01 00:00:00

  • Optimised analytical models of the dielectric properties of biological tissue.

    abstract::The interaction of electromagnetic fields with the human body is quantified by the dielectric properties of biological tissues. These properties are incorporated into complex numerical simulations using parametric models such as Debye and Cole-Cole, for the computational investigation of electromagnetic wave propagati...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.01.017

    authors: Salahuddin S,Porter E,Krewer F,O' Halloran M

    更新日期:2017-05-01 00:00:00

  • Automatic detection of EEG artefacts arising from head movements using EEG and gyroscope signals.

    abstract::Contamination of EEG signals by artefacts arising from head movements has been a serious obstacle in the deployment of automatic neurological event detection systems in ambulatory EEG. In this paper, we present work on categorizing these head-movement artefacts as one distinct class and on using support vector machine...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.08.017

    authors: O'Regan S,Faul S,Marnane W

    更新日期:2013-07-01 00:00:00

  • In vitro determination of the passive knee flexion axis: Effects of axis alignment on coupled tibiofemoral motions.

    abstract::The natural passive flexion axis of human cadaveric knees was determined using a technique that minimized coupled tibiofemoral motions (translations and rotations), and the kinematic effects of mal-positioned flexion axes were determined. The femur was clamped in an apparatus that allowed unconstrained tibial motions ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.03.009

    authors: Markolf KL,Yang PR,Joshi NB,Petrigliano FA,McAllister DR

    更新日期:2019-05-01 00:00:00

  • Thermographic imaging in the beating heart: a method for coronary flow estimation based on a heat transfer model.

    abstract::Intraoperative thermographic imaging in open-chest conditions can provide the surgeon with important qualitative information regarding coronary flow by utilizing heat transfer analysis following injection of cold saline into the aortic root. The heat transfer model is based on the assumption that the epicardial temper...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00040-x

    authors: Gordon N,Rispler S,Sideman S,Shofty R,Beyar R

    更新日期:1998-09-01 00:00:00

  • A numerical and experimental study of periodic flow in a model of a corrugated vessel with application to stented arteries.

    abstract::The investigation presented in this paper has attempted to study, from a fluid dynamics point of view, the consequences of the presence of a stent on the flow of blood. The method adopted is mainly by numerical simulation using a finite element technique, but visualization experiments and an analytical study have also...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00072-2

    authors: Natarajan S,Mokhtarzadeh-Dehghan MR

    更新日期:2000-10-01 00:00:00

  • An e-caring chair for physiological signal measurement and recording.

    abstract::There is an increasing awareness among the populace of the need for regular health check-up to detect diseases in their early stages and thereby administer treatments in a timely fashion. However, commercially available physiological signal monitoring devices, which may offer clues on the onset of diseases, are time-c...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.04.011

    authors: Chang HT,Chung CG,Chen MW

    更新日期:2013-02-01 00:00:00

  • Porcine carotid arterial material property alterations with induced atheroma: an in vivo study.

    abstract:OBJECTIVE:A novel methodology has been developed to evaluate regional alterations in arterial wall material properties with induced atheroma in an animal model. METHODS:Atheromatous lesions (fatty, fibro-fatty, and fibrous) were induced in the carotid arteries of a Yucatan miniswine model by endothelial cell denudatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.09.014

    authors: Nagaraj A,Kim H,Hamilton AJ,Mun JH,Smulevitz B,Kane BJ,Yan LL,Roth SI,McPherson DD,Chandran KB

    更新日期:2005-03-01 00:00:00

  • Mechanical characterization of bone anchors used with a bone-attached, parallel robot for skull surgery.

    abstract::Bone-attached robots and microstereotactic frames, intended for deep brain stimulation and minimally invasive cochlear implantation, typically attach to a patient's skull via bone anchors. A rigid and reliable link between such devices and the skull is mandatory in order to fulfill the high accuracy demands of minimal...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.02.012

    authors: Kobler JP,Prielozny L,Lexow GJ,Rau TS,Majdani O,Ortmaier T

    更新日期:2015-05-01 00:00:00

  • Validation of computerized square-drawing based evaluation of motor function in patients with stroke.

    abstract::Human-administered clinical scales are commonly used for quantifying motor performance and determining the course of therapy in post-stroke individuals. Computerized methods aim to improve consistency, resolution and duration of patients' evaluation. The objective of this study was to test the validity of computerized...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.06.001

    authors: Isaković MS,Savić AM,Konstantinović LM,Popović MB

    更新日期:2019-09-01 00:00:00

  • Acoustic power measurement of high-intensity focused ultrasound transducer using a pressure sensor.

    abstract::The acoustic power of high-intensity focused ultrasound (HIFU) is an important parameter that should be measured prior to each treatment to guarantee effective and safe outcomes. A new calibration technique was developed that involves estimating the pressure distribution, calculating the acoustic power using an underw...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.01.014

    authors: Zhou Y

    更新日期:2015-03-01 00:00:00

  • On the secondary stability of coated cementless hip replacement: parameters that affected interface strength.

    abstract::Unlike primary stability of coated cementless implants, their secondary stability has been poorly studied. This paper considers some theoretical aspects of the secondary stability of a coated cementless hip implant in a human femur. The bone is separated from the implant by a thin layer of microscopic peaks and trough...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(03)00099-7

    authors: Orlik J,Zhurov A,Middleton J

    更新日期:2003-12-01 00:00:00

  • Time-dependent analysis of leaflets in mechanical aortic bileaflet heart valves in closing phase using the finite strip method.

    abstract:BACKGROUND AND AIMS OF THE STUDY:Mechanical heart valves (MHV) are widely used to replace dysfunctional and failed heart valves. The bileaflet MHV design is very popular due to its superior hemodynamics. Since their introduction in 1977, the hemodynamics of bileaflet prostheses has been extensively studied. In this stu...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.03.013

    authors: Mohammadi H,Ahmadian MT,Wan WK

    更新日期:2006-03-01 00:00:00

  • Clinical workflow for personalized foot pressure ulcer prevention.

    abstract::Foot pressure ulcers are a common complication of diabetes because of patient's lack of sensitivity due to neuropathy. Deep pressure ulcers appear internally when pressures applied on the foot create high internal strains nearby bony structures. Monitoring tissue strains in persons with diabetes is therefore important...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.04.017

    authors: Bucki M,Luboz V,Perrier A,Champion E,Diot B,Vuillerme N,Payan Y

    更新日期:2016-09-01 00:00:00

  • Robust infrarenal aortic aneurysm lumen centerline detection for rupture status classification.

    abstract::The objective of this work is to develop a robust method for human abdominal aortic aneurysm (AAA) centerline detection that can contribute to the accurate computation of features for the prediction of AAA rupture risk. A semiautomatic algorithm is proposed for detecting the lumen centerline in contrast-enhanced abdom...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.03.005

    authors: Zhang H,Kheyfets VO,Finol EA

    更新日期:2013-09-01 00:00:00

  • Preliminary observations on the presence of sustained tendon strain and eccentric contractions of the wrist extensors during a common manual task: implications for lateral epicondylitis.

    abstract::Lateral epicondylitis (LE) is hypothesized to occur as a result of repetitive, strenuous and abnormal postural activities of the elbow and wrist. There is still a lack of understanding of how wrist and forearm positions contribute to this condition during common manual tasks. In this study the wrist kinematics and the...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.02.002

    authors: Murgia A,Harwin W,Prakoonwit S,Brownlow H

    更新日期:2011-07-01 00:00:00

  • Identification of lower arm motions using the EMG signals of shoulder muscles.

    abstract::This investigation explored pattern recognition of EMG signals produced by shoulder area muscles to identify the performance of a select number of lower arm motions. The signals were modelled as fourth-order autoregressive processes with the parameters of the models used to classify the different motions. The recorded...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(94)90024-8

    authors: Latwesen A,Patterson PE

    更新日期:1994-03-01 00:00:00

  • A method for determining the heat transfer and water vapour permeability of patient support systems.

    abstract::The formation of pressure ulcers can be exacerbated by a breakdown in the integrity of the patient's skin caused by poor maintenance of the skin microclimate. Patient support systems (PSSs-specialised beds, mattresses, chairs, cushions and pads) play an important role in the dissipation of heat and moisture away from ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00003-5

    authors: Nicholson GP,Scales JT,Clark RP,de Calcina-Goff ML

    更新日期:1999-12-01 00:00:00

  • Magnetic resonance-based thermometry during laser ablation on ex-vivo swine pancreas and liver.

    abstract::Laser Ablation (LA) is a minimally-invasive procedure for tumor treatment. LA outcomes depend on the heat distribution inside tissues and require accurate temperature measurement during the procedure. Magnetic resonance imaging (MRI) allows a non-invasive and three-dimensional thermometry of the organ undergoing LA. I...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.04.001

    authors: Allegretti G,Saccomandi P,Giurazza F,Caponero MA,Frauenfelder G,Di Matteo FM,Beomonte Zobel B,Silvestri S,Schena E

    更新日期:2015-07-01 00:00:00

  • A finite element model to accurately predict real deformations of the breast.

    abstract::Most surgical procedures in breast plastic surgery are either reconstructive procedures following oncologic interventions (tumorectomy, quadrantectomy, mastectomy ...) or aesthetic ones, both augmentation and reduction. With current techniques, the results of such procedures cannot be fully guaranteed. Usually, surgic...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.01.005

    authors: del Palomar AP,Calvo B,Herrero J,López J,Doblaré M

    更新日期:2008-11-01 00:00:00

  • A computational assessment of the hemodynamic effects of crossed and non-crossed bifurcated stent-graft devices for the treatment of abdominal aortic aneurysms.

    abstract::There are several issues attributed with abdominal aortic aneurysm endovascular repair. The positioning of bifurcated stent-grafts (SG) may affect SG hemodynamics. The hemodynamics and geometrical parameters of crossing or non-crossing graft limbs have not being totally accessed. Eight patient-specific SG devices and ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.09.011

    authors: Stefanov F,McGloughlin T,Morris L

    更新日期:2016-12-01 00:00:00

  • Bi-directional flow sensor with a wide dynamic range for medical applications.

    abstract::This paper describes a novel three-wire thermal flow sensor for medical applications. The present innovation for low-frequency measurements involves the use of a pulsed-wire anemometer with a comparatively large wire diameter (12.5 microm and larger) together with a novel signal processing approach. A small wire is he...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.06.002

    authors: Al-Salaymeh A,Jovanović J,Durst F

    更新日期:2004-10-01 00:00:00

  • Characterization of crackles from patients with fibrosis, heart failure and pneumonia.

    abstract::The spectral analysis of crackles sounds has been carried out based on the assumption that they are stationary signals, and the majority of the work on the crackles was accomplished before the publication of the Computerized Respiratory Sound Analysis (CORSA) guidelines. This works characterizes crackles acquired from...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.06.009

    authors: Ponte DF,Moraes R,Hizume DC,Alencar AM

    更新日期:2013-04-01 00:00:00

  • A pin-array method for capturing tissue deformation under defined pressure distributions and its application to prosthetic socket design.

    abstract::The Fit4Purpose project aims to develop upper limb prosthetic devices which are suitable for deployment in lower- and middle-income countries (LMIC's). Open-frame trans-radial socket designs are being considered, formed of several, linked components, including pads which interface directly with the skin surface. A mec...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.08.003

    authors: Prince M,Kenney LP,Howard D

    更新日期:2020-10-01 00:00:00