Abstract:
:The spectral analysis of crackles sounds has been carried out based on the assumption that they are stationary signals, and the majority of the work on the crackles was accomplished before the publication of the Computerized Respiratory Sound Analysis (CORSA) guidelines. This works characterizes crackles acquired from patients with fibrosis, heart failure, and pneumonia, breathing at a constant rate, with a system developed according to the CORSA guidelines. Their maximum frequency was obtained by applying discrete pseudo Wigner-Ville distribution, suitable for non-stationary signals, and an objective method to estimate the maximum frequency, the modified geometric method. The effects of the breathing rate and the tidal volume on the spectra of the crackles were also investigated. The role of the high-pass filter cutoff frequency of the acquisition system on the characteristics of the acquired crackles was also assessed in this present study. Higher high-pass filter cutoff frequency allows for higher amplification which modifies the maximum frequency and the 2CD index. It is shown that the crackles acquired according to the CORSA guidelines have higher frequencies and shorter 2CD indexes than those previously reported, highlighting the need for the standardization and detailed report of the acquisition setup when quantifying lung sounds. The results pointed out that the maximum frequency and the 2CD indexes may allow crackles generated by fibrosis to be distinguished from the ones generated by the heart failure and pneumonia. It is not possible, however, by means of these two indexes, to differentiate between pneumonia and heart failure crackles.
journal_name
Med Eng Physjournal_title
Medical engineering & physicsauthors
Ponte DF,Moraes R,Hizume DC,Alencar AMdoi
10.1016/j.medengphy.2012.06.009subject
Has Abstractpub_date
2013-04-01 00:00:00pages
448-56issue
4eissn
1350-4533issn
1873-4030pii
S1350-4533(12)00144-0journal_volume
35pub_type
杂志文章abstract::In this paper, we derive a comprehensive computational model to estimate the arterial pressure and the cardiac output of humans, by refining and adapting the well-established equations of the Windkessel theory. The model inputs are based on patient specific factors such as age, sex, smoking and fitness habits as well ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2008.11.010
更新日期:2009-06-01 00:00:00
abstract::Investigations of compressive frequency, duty cycle, or waveform during CPR are typically rooted in animal research or computer simulations. Our goal was to generate a mechanical model incorporating alternate stiffness settings and an integrated blood flow system, enabling defined, reproducible comparisons of CPR effi...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2017.02.005
更新日期:2017-05-01 00:00:00
abstract::Despite our understanding of the importance of falling, previous studies have ignored the effects of falls from standing height. In this article, lumped parameter linear and nonlinear models of a standing human have been used to simulate the impact response of the body segments due to inputs at the shoes. The accelera...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(96)00081-1
更新日期:1997-06-01 00:00:00
abstract::This study concerns the effects of different drilling parameters of pilot drills and twist drills on the temperature rise of alveolar bones during dental implant procedures. The drilling parameters studied here include the feed rate and rotation speed of the drill. The bone temperature distribution was analyzed throug...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.08.009
更新日期:2016-11-01 00:00:00
abstract::Acetabular fractures potentially account for up to half of all pelvic fractures, while pelvic fractures potentially account for over one-tenth of all human bone fractures. This is the first biomechanical study to assess acetabular fracture fixation using plates versus cables in the presence of a total hip arthroplasty...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2017.06.004
更新日期:2017-08-01 00:00:00
abstract::Reconstruction of segmental defects in the mandible remains a challenge for maxillofacial surgery. The use of porous scaffolds is a potential method for repairing these defects. Now, additive manufacturing techniques provide a solution for the fabrication of porous scaffolds with specific geometrical shapes and comple...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2017.06.015
更新日期:2017-09-01 00:00:00
abstract::Complications arising from limb-lengthening procedures such as muscle contracture, axial malalignment of the bone and traction injuries to the nerves and vessels, are often severe. Often complications arise from the build-up of forces in the biological tissues which are resisting lengthening. Little is known about the...
journal_title:Medical engineering & physics
pub_type: 临床试验,杂志文章
doi:10.1016/s1350-4533(97)00010-6
更新日期:1997-07-01 00:00:00
abstract::A system for acoustic analysis of pathological voices is proposed. The vocalized part of the voice signal is separated and all glottal cycles are traced by means of a cross-correlation detector. Based on the so determined beginning and duration of all glottal cycles, shimmer, jitter, several harmonics-to-noise ratios ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(02)00031-0
更新日期:2002-07-01 00:00:00
abstract::In case of large segmental defects in load-bearing bones, an external fixator is used to provide mechanical stability to the defect site. The overall stiffness of the bone-fixator system is determined not only by the fixator design but also by the way the fixator is mounted to the bone. This stiffness is an important ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2012.10.006
更新日期:2013-07-01 00:00:00
abstract::Characterising circulatory dysfunction and choosing a suitable treatment is often difficult and time consuming, and can result in a deterioration in patient condition, or unsuitable therapy choices. A stable minimal model of the human cardiovascular system (CVS) is developed with the ultimate specific aim of assisting...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2003.10.001
更新日期:2004-03-01 00:00:00
abstract::Computational fluid dynamics (CFD) simulations quantifying thoracic aortic flow patterns have not included disturbances from the aortic valve (AoV). 80% of patients with aortic coarctation (CoA) have a bicuspid aortic valve (BAV) which may cause adverse flow patterns contributing to morbidity. Our objectives were to d...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2012.07.015
更新日期:2013-06-01 00:00:00
abstract::Spinal pedicle screw fixations have been used extensively to treat fracture, tumor, infection, or degeneration of the spine. Cannulated spinal pedicle screws with bone cement augmentation might be a useful method to ameliorate screw loosening. However, cannulated spinal pedicle screws might also increase the risk of s...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.06.008
更新日期:2015-09-01 00:00:00
abstract::The complexity, nonlinearity and nonstationarity of the cardiovascular system typically defy comprehensive and deterministic mathematical modeling, except from a statistical perspective. Living systems are governed by numerous, continuously changing, interacting variables in the presence of noise. Cardiovascular signa...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(01)00112-6
更新日期:2002-01-01 00:00:00
abstract::The aim of this study is to develop a technical quality evaluation system of electroencephalogram (EEG) recording in order to acquire technically satisfactory EEG records, which may contribute to the accuracy improvement of EEG interpretation. In our developed system, the evaluation of EEG recording comprises the dete...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2004.09.001
更新日期:2005-01-01 00:00:00
abstract::The analysis of the surface electromyographic (sEMG) signal is particularly attractive because it provides relatively easy access to those physiological processes that allow the muscle to generate force and movement. In this paper, one of the possible applications of recurrence plot strategy to the analysis of sEMG is...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(99)00073-9
更新日期:1999-07-01 00:00:00
abstract::Whereas left ventricular assist device (LVAD) is the gold-standard therapy for patients with heart failure, gastrointestinal bleeding is one of the most common complications. LVAD implantation may remarkably impact aortic hemodynamics so that experimental and computational flow analyses can be used to study the diseas...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2017.06.029
更新日期:2017-09-01 00:00:00
abstract::A method for assessment and second-order polynomial detrending of signals containing periodic components is proposed. The analytically derived properties of this method are validated with synthesized signals, processed by the computational procedure developed. It is shown that, in addition to accurate detrending, the ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(98)00077-0
更新日期:1998-11-01 00:00:00
abstract::A through-water ultrasonic data telemetry system using burst-mode frequency shift keying (FSK) is described. The system can be adapted for the transmission of data from various sensors, but it has been designed principally for monitoring the respiratory rate, heart rate, temperature and depth of a free-swimming diver ...
journal_title:Medical engineering & physics
pub_type: 临床试验,杂志文章
doi:10.1016/1350-4533(94)90051-5
更新日期:1994-07-01 00:00:00
abstract::This paper describes the application of probabilistic design methods to the analysis of the behaviour of an uncemented total hip replacement femoral component implanted in a proximal femur. Probabilistic methods allow variations in factors which control the behaviour of the implanted femur (the input parameters) to be...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2009.01.002
更新日期:2009-05-01 00:00:00
abstract::Compared to conventional deep brain stimulation (DBS) for patients with Parkinson's Disease (PD), the newer approach of adaptive DBS (aDBS), regulating stimulation on the basis of the patient's clinical state, promises to achieve better clinical outcomes, avoid adverse-effects and save time for tuning parameters. A re...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.02.007
更新日期:2016-05-01 00:00:00
abstract::Recent research has indicated that consumers of upper limb prostheses desire lighter-weight, anthropomorphic devices. The potential of dielectric elastomer (DE) actuators to better meet the design priorities of prosthesis users is explored. Current challenges are critically reviewed with respect to (1) durability, (2)...
journal_title:Medical engineering & physics
pub_type: 杂志文章,评审
doi:10.1016/j.medengphy.2007.05.011
更新日期:2008-05-01 00:00:00
abstract::Surface electromyography (sEMG) has dominated upper-limb prosthesis control for decades due to its simplicity and effectiveness [1-3]. However, the inherent variability of EMG signal hinders the flexible and accurate control of advanced multi-functional prosthesis. This study is an attempt to use ultrasonography (US) ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.11.005
更新日期:2020-01-01 00:00:00
abstract::Despite its medical relevance, accurate recognition of sedentary (sitting and lying) and dynamic activities (e.g. standing and walking) remains challenging using a single wearable device. Currently, trunk-worn wearable systems can differentiate sitting from standing with moderate success, as activity classifiers often...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.01.001
更新日期:2014-06-01 00:00:00
abstract::Kinematic parameters for 10 normal subjects and 10 patients with ankle arthrodesis are grouped using the fuzzy cluster paradigm. The features chosen for clustering are Euler angles of the sagittal plane in the hindfoot, the forefoot and combined hindfoot and forefoot joints. Gait patterns are identified using informat...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(01)00020-0
更新日期:2001-03-01 00:00:00
abstract::To better understand the mechanisms underlying distal radius fracture we have developed finite element models to predict radius bone strain and fracture strength under loading conditions simulating a fall. This study compares experimental surface strains and fracture loads of the distal radius with specimen-specific f...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.07.016
更新日期:2012-04-01 00:00:00
abstract::The role and effect of preserved antegrade pulmonary blood flow (APBF) at the time of bidirectional cavopulmonary anastomosis (BCPA) in the management of single-ventricle physiology is controversial. We investigated the influence of APBF on the fluid dynamics of BCPA connection using computational fluid dynamics (CFD)...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2008.07.004
更新日期:2009-03-01 00:00:00
abstract::Currently, a number of studies focus on the study and design of new healthcare technologies to improve elderly health and quality of life. Taking advantage of the popularity, portability, and inherent technology of smartphones, we present an emergency application for smartphones, designated as knock-to-panic (KTP). Th...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.05.002
更新日期:2016-09-01 00:00:00
abstract::The value of compliance of disposable elements such as infusion lines and syringes can significantly affect the performance characteristics of infusion devices. In a technique used to determine the compliance of infusion lines, the item under test is placed in a semi sealed water filled enclosure and the volume of flu...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.07.016
更新日期:2014-11-01 00:00:00
abstract::The thermal conductivity of cortical bone was characterized experimentally. Specimens were taken from the mid-diaphysis of bovine femora, and the rate of heat transfer was measured in three orthogonal directions. The conductivity was found to be 0.58+/-0.018 W/mK in the longitudinal direction, 0.53+/-0.030 W/mK in the...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(01)00003-0
更新日期:2000-12-01 00:00:00
abstract::We present a finite element based simulation and analysis method to describe the spatial extent of stimulation and the effects of electrode-tissue interactions in subretinal prostheses. In particular, we estimate the threshold stimulation current needed to depolarise and evoke action potentials in the ganglion cells t...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.01.015
更新日期:2011-07-01 00:00:00