Abstract:
:To better understand the mechanisms underlying distal radius fracture we have developed finite element models to predict radius bone strain and fracture strength under loading conditions simulating a fall. This study compares experimental surface strains and fracture loads of the distal radius with specimen-specific finite element models to validate our model-generating algorithm. Five cadaveric forearms were instrumented with strain gage rosettes, loaded non-destructively to 300 N, and subsequently loaded until failure. Finite element models were created from computed tomography data; three separate density-elasticity relationships were examined. Fracture strength was predicted for three specimens that failed at the distal radius using six different failure theories. The density-elasticity relationship providing the strongest agreement between measured and predicted strains had a correlation of r=0.90 and a root mean squared error 13% of the highest measured strain. Mean absolute percent error (11.6%) between measured and predicted fracture loads was minimized with Coulomb-Mohr failure theory and a tensile-compressive strength ratio of 0.5. These results suggest that our modeling method is a suitable candidate for the in vivo assessment of distal radius bone strain and fracture strength under fall type loading configurations.
journal_name
Med Eng Physjournal_title
Medical engineering & physicsauthors
Edwards WB,Troy KLdoi
10.1016/j.medengphy.2011.07.016subject
Has Abstractpub_date
2012-04-01 00:00:00pages
290-8issue
3eissn
1350-4533issn
1873-4030pii
S1350-4533(11)00181-0journal_volume
34pub_type
杂志文章abstract::The temperature at which collagen denatures from a triple helix to a random coil structure is a useful measure of the degree of crosslinking. A new multi-sample denaturation temperature tester (DTT) has been constructed for rapid determination of the collagen denaturation temperature of natural tissues and collagenous...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(95)91882-h
更新日期:1995-03-01 00:00:00
abstract::Post-myocardial infarction remodeling process is known to alter the mechanical properties of the heart. Biomechanical parameters, such as tissue stiffness and contractility, would be useful for clinicians to better assess the severity of the diseased heart. However, these parameters are difficult to obtain in the curr...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2020.09.003
更新日期:2020-11-01 00:00:00
abstract::The aim of this study is to develop a technical quality evaluation system of electroencephalogram (EEG) recording in order to acquire technically satisfactory EEG records, which may contribute to the accuracy improvement of EEG interpretation. In our developed system, the evaluation of EEG recording comprises the dete...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2004.09.001
更新日期:2005-01-01 00:00:00
abstract::It is important to be able to quantify changes in gait pattern accurately in order to understand the clinical implications of surgery or rehabilitation. Although supervised feed-forward backpropagation neural networks are very efficient in many pattern-recognition tasks, the genetic algorithm neural network (GANN), wh...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(00)00011-4
更新日期:2000-01-01 00:00:00
abstract::Understanding morphological features that characterize normal hip joint is critical and necessary for a more comprehensive definition of pathological presentations, such as femoroacetabular impingement and hip dysplasia. Based on anatomical observations that articular surfaces of synovial joints are better represented...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2018.07.001
更新日期:2018-09-01 00:00:00
abstract::The prerequisite for the continuous in vivo monitoring of glucose concentration is the development of an implantable glucose sensor with long-term stability. A new enzyme electrode concept featuring fluid-state glucose oxidase modified carbon powder along with a cross-linked glucose oxidase enzyme layer has been devel...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(90)90008-v
更新日期:1994-09-01 00:00:00
abstract::Locking compression plates (LCPs) have been used to fix femoral shaft fractures. Previous studies have attempted to identify the best LCP screw positions and numbers to achieve the fixation stability. However, the determined screw positions and numbers were mainly based on the surgeons' experiences. The aim of this st...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2013.09.005
更新日期:2014-01-01 00:00:00
abstract::Human-administered clinical scales are commonly used for quantifying motor performance and determining the course of therapy in post-stroke individuals. Computerized methods aim to improve consistency, resolution and duration of patients' evaluation. The objective of this study was to test the validity of computerized...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.06.001
更新日期:2019-09-01 00:00:00
abstract::The natural passive flexion axis of human cadaveric knees was determined using a technique that minimized coupled tibiofemoral motions (translations and rotations), and the kinematic effects of mal-positioned flexion axes were determined. The femur was clamped in an apparatus that allowed unconstrained tibial motions ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.03.009
更新日期:2019-05-01 00:00:00
abstract::Using an anaesthetized cat's central footpad pressed against an object as the model of a paralyzed human hand, a nerve signal recording system was developed to measure the effect of a group of consecutive slips between the footpad and the object. Electroneurographic (ENG) activity was recorded using a cuff electrode i...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2007.05.007
更新日期:2008-05-01 00:00:00
abstract::A method aimed at the real-time monitoring of muscular fatigue was implemented and optimized. The method is based on an estimate of the complex covariance function in order to evaluate, in real time, the mean frequency of the myoelectric signal spectrum. Real-time implementation is guaranteed by a recursive computatio...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(99)00049-1
更新日期:1999-05-01 00:00:00
abstract::We have developed a method that allows biological tissues to be adhered together with minimal invasion by delivering integrated low-level energies from heat, pressure, and vibration. Tensile tests on adhered slices of porcine aorta were performed to determine the relationships between adhesive strength and conditions ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2009.12.005
更新日期:2010-05-01 00:00:00
abstract::Various simulation models of different complexity have been proposed to model the dynamic response of the human cardiovascular system. In a related paper we proposed an improved numerical model to study the dynamic response of the cardiovascular system, and the pressures, volumes and flow-rates in the four chambers of...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2005.11.005
更新日期:2006-10-01 00:00:00
abstract::A decrease in mobility, related to illness, trauma or ageing, negatively affects the quality of life of the rapidly growing elderly population. A promising solution to maintain this standard of living is powered wearable mobility assist devices. Although they have achieved technological breakthroughs in the last decad...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2020.03.008
更新日期:2020-06-01 00:00:00
abstract::The present investigation was conducted to see the effect of subcutaneous fat on the transmission characteristics of an electrical stimulus applied to the skin and conducted to skeletal muscle. Two groups of subjects participated. In one, the subjects were three males and three females whose average age was 24.6+/-1.5...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2008.02.009
更新日期:2008-11-01 00:00:00
abstract::Stent implantation has become a widely accepted endovascular intervention for the treatment of stenosed arteries. This minimally invasive technique has shown excellent results in unbranched arteries. However, stenting bifurcation lesions remains a challenge in coronary intervention as it is associated with a lower suc...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2008.11.013
更新日期:2009-05-01 00:00:00
abstract::Airway stents improve pulmonary function and quality of life in patients suffering from airway obstruction. The aim of this study was to compare main types of stents (silicone, balloon-dilated metal, self-expanding metal, and covered self-expanding metal) in terms of their mechanical properties and the radial forces t...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.02.008
更新日期:2015-04-01 00:00:00
abstract::Whereas left ventricular assist device (LVAD) is the gold-standard therapy for patients with heart failure, gastrointestinal bleeding is one of the most common complications. LVAD implantation may remarkably impact aortic hemodynamics so that experimental and computational flow analyses can be used to study the diseas...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2017.06.029
更新日期:2017-09-01 00:00:00
abstract:OBJECTIVE:A novel methodology has been developed to evaluate regional alterations in arterial wall material properties with induced atheroma in an animal model. METHODS:Atheromatous lesions (fatty, fibro-fatty, and fibrous) were induced in the carotid arteries of a Yucatan miniswine model by endothelial cell denudatio...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2004.09.014
更新日期:2005-03-01 00:00:00
abstract::Postural control deficits are the most disabling aspects of Parkinson's disease (PD), resulting in decreased mobility and functional independence. The aim of this study was to assess the postural control stability, revealed by variables based on the centre of pressure (CoP), in individuals with PD while performing a s...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.08.011
更新日期:2015-11-01 00:00:00
abstract::The biomedical applications of wireless robots are an active area of study. In addition to moving to a target lesion, wireless locomotive robots can deliver a therapeutic drug for a specific disease. Thus, they hold great potential as therapeutic devices in blood vessel diseases, such as thrombi and occlusions, and in...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.01.001
更新日期:2016-04-01 00:00:00
abstract::Contact interactions between the hand and handle, such as the contact surface softness and contact surface curvature, will affect both physical effort and musculoskeletal fatigue, thereby the comfort and safety of power tool operations. Previous models of hand gripping can be categorized into two groups: multi-body dy...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.03.007
更新日期:2014-07-01 00:00:00
abstract::Beat detection is a basic and fundamental step in electrocardiogram (ECG) processing. In many ECG applications strong artifacts from biological or technical sources could appear and cause distortion of ECG signals. Beat detection algorithm desired property is to avoid these distortions and detect beats in any situatio...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2012.07.017
更新日期:2013-06-01 00:00:00
abstract::The reliability of internal joint moment calculation in gait analysis during daily living activities is fundamental for clinical decisions based on joint function. This calculation, obtained by means of the inverse dynamics, depends on several modelling factors, such as assumptions on the segments and on the relevant ...
journal_title:Medical engineering & physics
pub_type: 临床试验,杂志文章
doi:10.1016/j.medengphy.2004.12.002
更新日期:2005-07-01 00:00:00
abstract::The aim of this study is to assess the utility of traditional statistical pattern recognition techniques to help in obstructive sleep apnoea (OSA) diagnosis. Classifiers based on quadratic (QDA) and linear (LDA) discriminant analysis, K-nearest neighbours (KNN) and logistic regression (LR) were evaluated. Spectral and...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2009.05.010
更新日期:2009-10-01 00:00:00
abstract::Electrochemotherapy (ECT) exploits the phenomenon of electroporation, which is the increase of cell permeability through the application of an electrical field. This technique is applied in medical centers in Europe and in veterinary clinics in Europe, Brazil, and Argentina. ECT treatment requires a minimum electric f...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.09.016
更新日期:2019-12-01 00:00:00
abstract::Automated methods of neonatal EEG seizure detection attempt to highlight the evolving, stereotypical, pseudo-periodic, nature of EEG seizure while rejecting the nonstationary, modulated, coloured stochastic background in the presence of various EEG artefacts. An important aspect of neonatal seizure detection is, there...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.08.001
更新日期:2012-05-01 00:00:00
abstract::Miniaturized and parallelized sandwich immunoassays allow the simultaneous analysis of a variety of parameters in a single experiment. Bead-based protein array systems or suspension microarrays are well-established multiplex sandwich immunoassay formats. To study inflammatory diseases, protein arrays can be used to an...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2008.01.003
更新日期:2008-10-01 00:00:00
abstract::The objective of this study is to determine the three dimensional kinematics of the human pelvis including both sacroiliac joints following a simulated open book injury induced on cadavers by applying anterior-posterior compressive loads to the pelvis. An electromagnetic digitizing and motion tracking system was utili...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(02)00196-0
更新日期:2003-05-01 00:00:00
abstract::Small spaces make collision-free turns difficult for wheelchair users. Contrary to basic kinematic wheelchair modelling and not considered previously by engineers; when wheelchairs turn in small spaces, could lateral drift (sideways slipping) increase the risk of collisions with surrounding structures such as walls an...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2020.11.012
更新日期:2021-01-01 00:00:00