Abstract:
:A system for acoustic analysis of pathological voices is proposed. The vocalized part of the voice signal is separated and all glottal cycles are traced by means of a cross-correlation detector. Based on the so determined beginning and duration of all glottal cycles, shimmer, jitter, several harmonics-to-noise ratios and other widely used acoustic parameters are calculated. New parameters are also introduced for estimation of the turbulent noise in voice signals (Turbulent Noise Index - TNI) and for the "breathy" voice characterization (Normalized First Harmonic Energy - NFHE). These parameters are applied for laryngeal pathology detection. An identification accuracy of 96.1% by the K-nearest neighbors' method has been achieved. The system is clinically tested.
journal_name
Med Eng Physjournal_title
Medical engineering & physicsauthors
Hadjitodorov S,Mitev Pdoi
10.1016/s1350-4533(02)00031-0subject
Has Abstractpub_date
2002-07-01 00:00:00pages
419-29issue
6eissn
1350-4533issn
1873-4030pii
S1350453302000310journal_volume
24pub_type
杂志文章abstract::In this study, we propose a new classification method for early differentiation of paroxysmal and persistent atrial fibrillation episodes, i.e. those which spontaneously or with external intervention will return to sinus rhythm within 7 days of onset from the ones where the arrhythmia is sustained for more than 7 days...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.10.013
更新日期:2017-01-01 00:00:00
abstract::The second-order difference plot, as a modified Poincaré plot, is one of the important approaches for assessing the dynamics of heart rate variability. However, corresponding quantitative analysis methods are relatively limited. Based on the second-order difference plot, we propose a novel method, called the multi-sca...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.09.015
更新日期:2014-12-01 00:00:00
abstract::The purpose of the present study was to compare the passive angle-torque curves and the passive stiffness (PS, N m °(-)(1)) values recorded simultaneously from a load cell versus an isokinetic dynamometer during dorsiflexion stretch tolerance assessments in vivo. Nine healthy men (mean ± SD age = 21.4 ± 1.6 years) com...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.02.010
更新日期:2015-05-01 00:00:00
abstract::We present a finite element based simulation and analysis method to describe the spatial extent of stimulation and the effects of electrode-tissue interactions in subretinal prostheses. In particular, we estimate the threshold stimulation current needed to depolarise and evoke action potentials in the ganglion cells t...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.01.015
更新日期:2011-07-01 00:00:00
abstract::Computational fluid dynamics (CFD) simulations quantifying thoracic aortic flow patterns have not included disturbances from the aortic valve (AoV). 80% of patients with aortic coarctation (CoA) have a bicuspid aortic valve (BAV) which may cause adverse flow patterns contributing to morbidity. Our objectives were to d...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2012.07.015
更新日期:2013-06-01 00:00:00
abstract::Despite our understanding of the importance of falling, previous studies have ignored the effects of falls from standing height. In this article, lumped parameter linear and nonlinear models of a standing human have been used to simulate the impact response of the body segments due to inputs at the shoes. The accelera...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(96)00081-1
更新日期:1997-06-01 00:00:00
abstract::This study concerns the effects of different drilling parameters of pilot drills and twist drills on the temperature rise of alveolar bones during dental implant procedures. The drilling parameters studied here include the feed rate and rotation speed of the drill. The bone temperature distribution was analyzed throug...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.08.009
更新日期:2016-11-01 00:00:00
abstract::Observational balance tests (e.g., Berg Balance Scale) are used to evaluate fall-risk. However, they tend to be subjective, and their reliability and sensitivity can be limited. The use of in-lab equipment for objective balance evaluation has not been common in clinical practice, due to the requirement of an equipped ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.10.018
更新日期:2020-03-01 00:00:00
abstract::Functional spinal units (FSUs) are frequently used for in vitro mechanical testing. This approach assumes that the mechanical behavior of the FSUs is equivalent to the mechanics of these segments within the intact spine. The purpose of this study was to determine whether normal spinal mechanics are compromised in FSU ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(02)00152-2
更新日期:2003-04-01 00:00:00
abstract::To better understand the mechanisms underlying distal radius fracture we have developed finite element models to predict radius bone strain and fracture strength under loading conditions simulating a fall. This study compares experimental surface strains and fracture loads of the distal radius with specimen-specific f...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.07.016
更新日期:2012-04-01 00:00:00
abstract::The strains developed on the surface of a femur with and without an implanted femoral hip replacement were investigated using holographic interferometry (HI). Interferometric fringe data from the four aspects of the loaded femur were quantified and the resulting curvature calculated. Curvature was related to the strai...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(98)00003-4
更新日期:1998-03-01 00:00:00
abstract::Two quantitative techniques have been evaluated to examine whether respiratory sinus arrhythmia can be detected in atrial fibrillation. Cyclical changes in heart rate during deep breathing indicating respiratory sinus arrhythmia were seen in 11/15 control patients, but only 1/44 patients with atrial fibrillation. Powe...
journal_title:Medical engineering & physics
pub_type: 临床试验,杂志文章
doi:10.1016/1350-4533(94)90061-2
更新日期:1994-07-01 00:00:00
abstract::In most computational fluid dynamic (CFD) analysis of the human lung, it has been assumed that the trachea and branches of the lung have smooth walls. In order to determine if this is a valid assumption, the effects of cartilage rings on airflow and particle deposition in the lungs was determined through conducting si...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2007.06.010
更新日期:2008-06-01 00:00:00
abstract::The pulse pressure waveform has, for long, been known as a fundamental biomedical signal and its analysis is recognized as a non-invasive, simple, and resourceful technique for the assessment of arterial vessels condition observed in several diseases. In the current paper, waveforms from non-invasive optical probe tha...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.07.014
更新日期:2014-11-01 00:00:00
abstract::Unlike primary stability of coated cementless implants, their secondary stability has been poorly studied. This paper considers some theoretical aspects of the secondary stability of a coated cementless hip implant in a human femur. The bone is separated from the implant by a thin layer of microscopic peaks and trough...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(03)00099-7
更新日期:2003-12-01 00:00:00
abstract::In contrast enhanced magnetic resonance imaging (MRI) and computed tomography (CT), the equilibrium distribution of anionic contrast agent is expected to reflect the fixed charged density (FCD) of articular cartilage. Diffusion is mainly responsible for the transport of contrast agents into cartilage. In osteoarthriti...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2010.06.002
更新日期:2010-10-01 00:00:00
abstract::The loads between adjacent vertebrae can be generalised as a single spatial force acting at the intervertebral centre of reaction. The exact position in vivo is unknown. However, in rigid body musculoskeletal models that simulate upright standing, the position is generally assumed to be located at the discs' centres o...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.12.003
更新日期:2016-03-01 00:00:00
abstract::A model of the lumbar spine, pelvis and buttocks is developed, based on linear horizontal and vertical systems along with a rotational subsystem. The model can mimic qualitatively different experimental observations of transmission of vibrations from the seat to L3 in the sitting posture. It is concluded that while th...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(95)00062-3
更新日期:1996-07-01 00:00:00
abstract::We studied muscle fatigue in 19 paraplegic patients during an isometric sustained contraction. Both quadriceps (n = 38) were maximally stimulated for 126 s. We defined a nonlinear equation with four coefficients to fit the data and extract fatigue indices carrying information on the amount (asymptotic values, torque c...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(97)00038-6
更新日期:1997-12-01 00:00:00
abstract::Whereas left ventricular assist device (LVAD) is the gold-standard therapy for patients with heart failure, gastrointestinal bleeding is one of the most common complications. LVAD implantation may remarkably impact aortic hemodynamics so that experimental and computational flow analyses can be used to study the diseas...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2017.06.029
更新日期:2017-09-01 00:00:00
abstract::To determine the reliability, stability, validity and precision of a stereophotogrammetry (SP) system for use in quantifying the complex three-dimensional structure of the human torso, we performed assessments of the system using images of geometric solids and a human-form mannequin. Analysis of geometric solids revea...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2009.08.011
更新日期:2009-12-01 00:00:00
abstract::Apparatus has been built to explore the practical feasibility of using automatic control with electrical stimulation of paralysed legs to restore function. The experiments are performed with paraplegics with the aim of achieving a realistic postural task: to see whether the body may be maintained upright by stimulatio...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(97)00020-9
更新日期:1997-09-01 00:00:00
abstract::The natural passive flexion axis of human cadaveric knees was determined using a technique that minimized coupled tibiofemoral motions (translations and rotations), and the kinematic effects of mal-positioned flexion axes were determined. The femur was clamped in an apparatus that allowed unconstrained tibial motions ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.03.009
更新日期:2019-05-01 00:00:00
abstract::A DNA electrochemical biosensor is an integrated receptor-transducer device. The most important step in the development and manufacture of a sensitive DNA-biosensor for the detection of DNA-drug interactions is the immobilization procedure of the nucleic acid probe on the transducer surface. Magnetic A/C Mode atomic f...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2006.05.009
更新日期:2006-12-01 00:00:00
abstract::Human-administered clinical scales are commonly used for quantifying motor performance and determining the course of therapy in post-stroke individuals. Computerized methods aim to improve consistency, resolution and duration of patients' evaluation. The objective of this study was to test the validity of computerized...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.06.001
更新日期:2019-09-01 00:00:00
abstract::This study presents a specimen-specific C2-C7 cervical spine finite element model that was developed using multiblock meshing techniques. The model was validated using in-house experimental flexibility data obtained from the cadaveric specimen used for mesh development. The C2-C7 specimen was subjected to pure continu...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2010.03.001
更新日期:2010-06-01 00:00:00
abstract::In stark contrast to the inspiring functionality of the natural hand, limitations of current upper limb prostheses stemming from marginal feedback control, challenges of mechanical design, and lack of sensory capacity, are well-established. This paper provides a critical review of current sensory systems and the poten...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2005.09.009
更新日期:2006-07-01 00:00:00
abstract::This study presents a novel method for the detection and classification of a wide range of physical activities, including standing, sitting, lying, level walking, and walking upstairs and downstairs using a single chest-mounted accelerometer. The trunk inclination angle and variation of the gravitational component of ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2018.04.008
更新日期:2018-07-01 00:00:00
abstract:OBJECTIVE:Joint space narrowing is an important feature of progressive joint damage and functional impairment in rheumatoid arthritis (RA). Methods to provide a continuous measurement of joint space width have not been adopted in research or clinical settings. High-resolution peripheral quantitative computed tomography...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2013.04.003
更新日期:2013-10-01 00:00:00
abstract::The incudostapedial joint (ISJ) is a synovial joint connecting the incus and stapes in the middle ear. Mechanical properties of the ISJ directly affect sound transmission from the tympanic membrane to the cochlea. However, how ISJ properties change with frequency has not been investigated. In this paper, we report the...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2018.02.006
更新日期:2018-04-01 00:00:00