Reproducible metacarpal joint space width measurements using 3D analysis of images acquired with high-resolution peripheral quantitative computed tomography.

Abstract:

OBJECTIVE:Joint space narrowing is an important feature of progressive joint damage and functional impairment in rheumatoid arthritis (RA). Methods to provide a continuous measurement of joint space width have not been adopted in research or clinical settings. High-resolution peripheral quantitative computed tomography (HR-pQCT) (Scanco Medical AG, Brüttisellen, Switzerland) accurately and reproducibly images bone microstructure at a nominal isotropic voxel dimension of 82 μm. Given the ability of HR-pQCT to detect bone margins with high precision, we developed methodology to measure a three-dimensional (3D) metacarpophalangeal (MCP) joint space width and tested the reproducibility of the scan protocol with hand repositioning. MATERIALS AND METHODS:Consecutive HR-pQCT scans of the 2nd and 3rd MCP joints of ten subjects with early RA (70% female, mean age 45 years), with repositioning between scans, were obtained. The periosteal edges of the metacarpal head and proximal phalanx base were detected using the μCT Evaluation Program V6.0 (Scanco Medical AG). Using the method of 'fitting maximal spheres', the joint space width and distribution of joint space thickness was estimated. RESULTS:The mean minimum joint space width of the 2nd MCP was 1.82 mm (SD 0.20) and of the 3rd MCP 1.84 mm (SD 0.23). Reproducibility with repositioning was reliable, with overlapping filtered histograms and a root square mean coefficient of variance of 4.8%. CONCLUSIONS:We provide reproducible methodology for evaluating the joint space width of the MCP joints. When combined with the assessment of erosions and periarticular bone density, HR-pQCT may be the ideal technology to assess disease activity and progression in RA.

journal_name

Med Eng Phys

authors

Barnabe C,Buie H,Kan M,Szabo E,Barr SG,Martin L,Boyd SK

doi

10.1016/j.medengphy.2013.04.003

subject

Has Abstract

pub_date

2013-10-01 00:00:00

pages

1540-4

issue

10

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(13)00096-9

journal_volume

35

pub_type

杂志文章
  • Fuzzy clustering of gait patterns of patients after ankle arthrodesis based on kinematic parameters.

    abstract::Kinematic parameters for 10 normal subjects and 10 patients with ankle arthrodesis are grouped using the fuzzy cluster paradigm. The features chosen for clustering are Euler angles of the sagittal plane in the hindfoot, the forefoot and combined hindfoot and forefoot joints. Gait patterns are identified using informat...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00020-0

    authors: Su F,Wu W,Cheng Y,Chou Y

    更新日期:2001-03-01 00:00:00

  • A new method of assessing the mechanical properties of patient support systems (PSS) using a phantom. A preliminary communication.

    abstract::Pressure ulcers are a major problem worldwide believed to affect over 5% of all hospital in-patients, and countless others in the community at large. Many types of Patient Support Systems (PSS) are sold as pressure ulcer prevention equipment, but no consensus exists as to their mechanical efficacy. The use of human vo...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00053-3

    authors: Bain DS,Scales JT,Nicholson GP

    更新日期:1999-06-01 00:00:00

  • Variation of the impact duration during the in vitro insertion of acetabular cup implants.

    abstract::The acetabular cup (AC) is an implant impacted into a bone cavity and used for hip prosthesis surgery. Initial stability of the AC is an important factor for long term surgical success. The aim of this study is to determine the variations of the impact duration during AC implant insertion. Twenty-two bone samples take...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.04.005

    authors: Mathieu V,Michel A,Flouzat Lachaniette CH,Poignard A,Hernigou P,Allain J,Haïat G

    更新日期:2013-11-01 00:00:00

  • An investigation to determine if a single validated density-elasticity relationship can be used for subject specific finite element analyses of human long bones.

    abstract::Subject-specific FE-models of human long bones have to predict mechanical parameters with sufficient accuracy to be applicable in a clinical setting. One of the main aspects in subject-specific FE-models of bones regarding accuracy is the modeling of the material inhomogeneity. The goal of this study was therefore to ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.08.022

    authors: Eberle S,Göttlinger M,Augat P

    更新日期:2013-07-01 00:00:00

  • Stimulated production of vowel-like LX-waveforms and spectral damping in the absence of phonation.

    abstract::Electrical impedance 'LX' waveforms measured across the neck at the thyroid level during phonation are known to be correlated with vocal fold movement. Changes in vocal fold contact are thought to be the cause of this phenomenon though emerging applications in radiotherapy indicate that changes in the configuration of...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00065-6

    authors: Moore C,Jones S

    更新日期:2002-09-01 00:00:00

  • A finite element model to accurately predict real deformations of the breast.

    abstract::Most surgical procedures in breast plastic surgery are either reconstructive procedures following oncologic interventions (tumorectomy, quadrantectomy, mastectomy ...) or aesthetic ones, both augmentation and reduction. With current techniques, the results of such procedures cannot be fully guaranteed. Usually, surgic...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.01.005

    authors: del Palomar AP,Calvo B,Herrero J,López J,Doblaré M

    更新日期:2008-11-01 00:00:00

  • Measurement of ejection fraction with standard thermodilution catheters.

    abstract::Right ventricle ejection fraction (RVEF) is clinically used to evaluate right ventricular function. The thermodilution method can be modified to estimate the RVEF. However, this method requires a thermistor with a fast time response in order to yield correct estimates. Digital signal processing techniques that were de...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00026-7

    authors: dos Santos I,Ferreira da Rocha A,Assis de O Nascimento F,Souza Neto J,Valvano JW

    更新日期:2002-06-01 00:00:00

  • Ultrasonography and electromyography based hand motion intention recognition for a trans-radial amputee: A case study.

    abstract::Surface electromyography (sEMG) has dominated upper-limb prosthesis control for decades due to its simplicity and effectiveness [1-3]. However, the inherent variability of EMG signal hinders the flexible and accurate control of advanced multi-functional prosthesis. This study is an attempt to use ultrasonography (US) ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.11.005

    authors: Wang Z,Fang Y,Zhou D,Li K,Cointet C,Liu H

    更新日期:2020-01-01 00:00:00

  • Effects of laminectomy and facetectomy on the stability of the lumbar motion segment.

    abstract::A ligamentous, nonlinear, sliding contact, three-dimensional finite element (FE) model of L2-L3 complex was developed to investigate the biomechanical effect of laminectomy with and without facetectomy. The L2-L3 FE model was validated against experimental study under various physiological loadings and found to match ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2003.11.006

    authors: Lee KK,Teo EC

    更新日期:2004-04-01 00:00:00

  • Characterizing the reduction of stimulation artifact noise in a tripolar nerve cuff electrode by application of a conductive shield layer.

    abstract::Tripolar nerve cuff electrodes have been widely used for measuring peripheral nerve activity. However, despite the high signal-to-noise ratio levels that can be achieved with this recording configuration, the clinical use of cuff electrodes in closed-loop controlled neuroprostheses remains limited. This is largely att...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.11.010

    authors: Sabetian P,Sadeghlo B,Zhang CH,Yoo PB

    更新日期:2017-02-01 00:00:00

  • Reliability, validity, and precision of an active stereophotogrammetry system for three-dimensional evaluation of the human torso.

    abstract::To determine the reliability, stability, validity and precision of a stereophotogrammetry (SP) system for use in quantifying the complex three-dimensional structure of the human torso, we performed assessments of the system using images of geometric solids and a human-form mannequin. Analysis of geometric solids revea...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.08.011

    authors: Paul SM,Chamberlin AP,Hatt C,Nayak AV,Danoff JV

    更新日期:2009-12-01 00:00:00

  • Pre-planning of intramedullary nailing procedures: A methodology for predicting the position of the distal hole.

    abstract::Inserting the distal locking screws is a challenging step of the intramedullary nailing procedures due to the nail deformation that makes the proximally mounted targeting systems ineffective. A pre-planning methodology is proposed, based on an analytical model of the nail-bone construct, to predict the nail deformatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.09.012

    authors: Mortazavi J,Farahmand F,Behzadipour S,Yeganeh A

    更新日期:2019-12-01 00:00:00

  • Non-invasive measurement of hepatic oxygenation by an oxygen electrode in human orthotopic liver transplantation.

    abstract::Precise evaluation of graft reperfusion is difficult in clinical liver transplantation. The oxygen electrode (OE) is a novel technique to detect blood flow indirectly by measuring the quantity of oxygen which can diffuse from the hepatic tissue to the surface electrode. Application of the surface OE does not influence...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00060-6

    authors: Seifalian AM,Mallett S,Piasecki C,Rolles K,Davidson BR

    更新日期:2000-06-01 00:00:00

  • Modelization of a self-opening peripheral neural interface: a feasibility study.

    abstract::In this paper a self-opening intrafascicular neural interface (SELINE) has been modeled using both a theoretical approach and a Finite Element (FE) analysis. This innovative self opening interface has several potential advantages such as: higher selectivity due to its three-dimensional structure and efficient anchorag...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.06.001

    authors: Cutrone A,Sergi PN,Bossi S,Micera S

    更新日期:2011-12-01 00:00:00

  • Kinematics of the human pelvis following open book injury.

    abstract::The objective of this study is to determine the three dimensional kinematics of the human pelvis including both sacroiliac joints following a simulated open book injury induced on cadavers by applying anterior-posterior compressive loads to the pelvis. An electromagnetic digitizing and motion tracking system was utili...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00196-0

    authors: Hefzy MS,Ebraheim N,Mekhail A,Caruntu D,Lin H,Yeasting R

    更新日期:2003-05-01 00:00:00

  • Grasping soft tissue by means of vacuum technique.

    abstract:INTRODUCTION:A notable characteristic of bariatric surgery is the frequent manipulation of the bowel. The bowel is large, delicate, flexible, and has a natural lubricant on the tissue surface. Therefore the bowel is difficult to grasp and manipulate. Vacuum technique is commonly used in industry for all types of graspi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.11.014

    authors: Vonck D,Jakimowicz JJ,Lopuhaä HP,Goossens RH

    更新日期:2012-10-01 00:00:00

  • Non-invasive identification of gastric contractions from surface electrogastrogram using back-propagation neural networks.

    abstract::Gastric contractions play an important role in the digestive process of the stomach. The established method for the measurement of gastric contractions is invasive and involves the insertion through the nose of a manometric probe into the stomach. A non-invasive method is introduced in this paper for the identificatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)95713-k

    authors: Chen JD,Lin Z,Wu Q,McCallum RW

    更新日期:1995-04-01 00:00:00

  • A method of examining the magnitude and origin of "soft" and "hard" tissue forces resisting limb lengthening.

    abstract::Complications arising from limb-lengthening procedures such as muscle contracture, axial malalignment of the bone and traction injuries to the nerves and vessels, are often severe. Often complications arise from the build-up of forces in the biological tissues which are resisting lengthening. Little is known about the...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/s1350-4533(97)00010-6

    authors: Gardner TN,Evans M,Simpson AH,Kyberd PJ,Kenwright J

    更新日期:1997-07-01 00:00:00

  • A non-invasive Cochlear Microphonic measurement system.

    abstract::The Cochlear Microphonic is one of the electrical potentials generated by the ear in response to audible stimuli. It is very difficult to measure the CM non-invasively because it has a very small magnitude (less than 1 μV). A high Common Mode Rejection Ratio (CMRR) and very large bandwidth (5 Hz-20 kHz) biomedical amp...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.06.017

    authors: Masood A,Teal PD,Hollitt C

    更新日期:2012-10-01 00:00:00

  • A biomechanical model to determine lumbosacral loads during single stance phase in normal gait.

    abstract::A dynamic biomechanical model to determine loads (joint forces) attained at the lumbosacral joint-centre during the stance phase of normal level walking was developed. The biomechanical model was based on rigid free body-segments; namely, the foot, shank, thigh, pelvis and head, arms and trunk (HAT) segments. In this ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)90374-k

    authors: Khoo BC,Goh JC,Bose K

    更新日期:1995-01-01 00:00:00

  • Design and testing of a high-speed treadmill to measure ground reaction forces at the limit of human gait.

    abstract::Investigations focused on the gait and physiological limits of human speed have been on-going for more than a century. However, due to measurement limitation a kinetic understanding of the foot-ground collision and how these dynamics differ between individuals to confer speed and limit gait has only recently begun to ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.04.009

    authors: Bundle MW,Powell MO,Ryan LJ

    更新日期:2015-09-01 00:00:00

  • Computation of the elastic properties of a resin impregnated wire mesh by the means of a homogenisation procedure.

    abstract::The present paper presents a homogenisation technique applied to the problem of calculating equivalent material properties of a resin impregnated wire mesh. Although this type of material can be expected to possess, in general, a four-fold axis of rotational symmetry, it was found that a transversally isotropic model ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00065-5

    authors: Hübsch PF,Middleton J,Knox J

    更新日期:2000-09-01 00:00:00

  • Attention attraction in an ophthalmic diagnostic device using sound-modulated fixation targets.

    abstract::This study relates to eye fixation systems with combined optical and audio systems. Many devices for eye diagnostics and some devices for eye therapeutics require the patient to fixate on a small target for a certain period of time, during which the eyes do not move and data from substructures of one or both eyes are ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.05.004

    authors: Gramatikov BI,Rangarajan S,Irsch K,Guyton DL

    更新日期:2016-08-01 00:00:00

  • Assessing the sound of cough towards vocality.

    abstract::The presented research positively evaluates the vocality of the cough sound by estimating the global cough fundamental frequency or pitch. The fundamental frequency was determined by autocorrelation analysis on both the original time-signal and the linear predicted time-signal. The experimental cough database was regi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00055-3

    authors: Van Hirtum A,Berckmans D

    更新日期:2002-09-01 00:00:00

  • Design of a biodegradable plate for femoral shaft fracture fixation.

    abstract::Biodegradable materials have been generating increasing bit of interest in biomedical applications and associated research. The evolution of implants made up of such materials (Mg-alloys, etc.) has the potential to be a game changer in fracture surgeries. These implants are essentially made up of a plate and a number ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.05.010

    authors: Chandra G,Pandey A,Pandey S

    更新日期:2020-07-01 00:00:00

  • Intramedullary femoral nails: one or two lag screws? A preliminary study.

    abstract::Failures of proximal femoral nails that treat unstable femoral fractures have been reported. In this communication, a finite element model to include a proximal femoral nail within a fractured femur was used to carry out preliminary investigations into configurations of single or double lag screws. The effects of the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00081-3

    authors: Wang CJ,Brown CJ,Yettram AL,Procter P

    更新日期:2000-11-01 00:00:00

  • Sensitivity analysis of the position of the intervertebral centres of reaction in upright standing--a musculoskeletal model investigation of the lumbar spine.

    abstract::The loads between adjacent vertebrae can be generalised as a single spatial force acting at the intervertebral centre of reaction. The exact position in vivo is unknown. However, in rigid body musculoskeletal models that simulate upright standing, the position is generally assumed to be located at the discs' centres o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.12.003

    authors: Zander T,Dreischarf M,Schmidt H

    更新日期:2016-03-01 00:00:00

  • Three-dimensional localisation based on projectional and tomographic image correlation: an application for digital tomosynthesis.

    abstract::Accurate three-dimensional tumor localisation in Radiotherapy, is critical to the treatment outcome, particularly when high dose gradients are present. A number of techniques have been proposed for the localisation of anatomical structures or markers. The present study proposes an approach to a concurrent maximisation...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00015-6

    authors: Messaris G,Kolitsi Z,Badea C,Pallikarakis N

    更新日期:1999-03-01 00:00:00

  • Application of time-varying analysis to diagnostic needle electromyography.

    abstract::Quantification in clinical, diagnostic electromyography (EMG) currently includes motor unit action potential (MUAP) analysis and interference pattern analysis. Early efforts to examine the frequency/power spectra of the interference pattern showed modest value but the technique was not developed further. This paper re...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.07.017

    authors: Sheean GL

    更新日期:2012-03-01 00:00:00

  • Pulsatile impeller heart: a viable alternative to a problematic diaphragm heart.

    abstract::The impeller blood pump with its simplicity has many advantages compared with the diaphragm pump, but the nonpulsatile property has limited its applications. To make the impeller pump pulsatile, many investigations have been made in vain because of resulting haemolysis. The author has succeeded in producing a pulsatil...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)00010-0

    authors: Qian KX

    更新日期:1996-01-01 00:00:00