Abstract:
:The objective of this study is to determine the three dimensional kinematics of the human pelvis including both sacroiliac joints following a simulated open book injury induced on cadavers by applying anterior-posterior compressive loads to the pelvis. An electromagnetic digitizing and motion tracking system was utilized to measure the morphology of the pelvis and the relative movements of its bones during this simulated open book fracture. The screw displacement axis method was used to describe the relative motion between the sacrum and each hipbone. Morphologically, it was found that the articular surfaces forming the sacroiliac joints could be approximated with planar surfaces directed from proximal and lateral to distal and medial and from posteromedial to anterolateral. The kinematic data obtained from this study indicate that there is a direct correlation between the opening of the symphysis pubis and the opening of the sacroiliac joint (SIJ) during open book injury. This suggests that the extent of injury of the SIJ maybe estimated from the degree of opening of the symphysis pubis as demonstrated on anteroposterior (A-P) x-rays. The results obtained from this study also indicate that the motion of the hipbone with respect to the sacrum on the side of the sacroiliac joint opening is almost a pure rotation, which translates clinically on the A-P x-rays as pure opening of the SIJ without vertical displacement. The average axis of rotation was found to be almost parallel to the SIJ planar articular surface. Furthermore, the pubic bone on the side of SIJ opening was found to displace inferiorly and posteriorly. One can thus conclude that in open book pelvic injuries, the pubic bone on the side of injury displaces inferiorly on the outlet projection x-rays with no vertical displacement of the SIJ. This is important since the initial assessment of the open book injury in the emergency room includes outlet projection x-rays. From this study, the relative vertical positions of the pubic bones on these x-rays can help the surgeon in differentiating open book fracture injury from other pelvic injuries.
journal_name
Med Eng Physjournal_title
Medical engineering & physicsauthors
Hefzy MS,Ebraheim N,Mekhail A,Caruntu D,Lin H,Yeasting Rdoi
10.1016/s1350-4533(02)00196-0subject
Has Abstractpub_date
2003-05-01 00:00:00pages
259-74issue
4eissn
1350-4533issn
1873-4030pii
S1350453302001960journal_volume
25pub_type
杂志文章abstract::The Fit4Purpose project aims to develop upper limb prosthetic devices which are suitable for deployment in lower- and middle-income countries (LMIC's). Open-frame trans-radial socket designs are being considered, formed of several, linked components, including pads which interface directly with the skin surface. A mec...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2020.08.003
更新日期:2020-10-01 00:00:00
abstract::This study relates to eye fixation systems with combined optical and audio systems. Many devices for eye diagnostics and some devices for eye therapeutics require the patient to fixate on a small target for a certain period of time, during which the eyes do not move and data from substructures of one or both eyes are ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.05.004
更新日期:2016-08-01 00:00:00
abstract::A numerical model was developed to predict the dynamics of a solid particle in a poststenotic blood vessel region. The flow through a 3D axisymmetric stenosis with 75% reduction in cross-section area was considered for inlet Reynolds numbers of 500 and 1000, which corresponds to typical values for the blood flow in hu...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.11.003
更新日期:2012-09-01 00:00:00
abstract:BACKGROUND:An ideal prosthetic mesh for incisional hernia repair should mimic the anisotropic compliance of the abdominal wall, and at lower loads should exhibit higher distensibility without impairment of safety at higher loads. This study evaluated the biomechanical properties of six meshes in a rabbit model. METHOD...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.09.022
更新日期:2012-09-01 00:00:00
abstract::In recent years, a combination of traction and vibration therapy is usually used to alleviate low back pain (LBP) in clinical settings. Combining head-down tilt (HDT) traction with vibration was demonstrated to be efficacious for LBP patients in our previous study. However, the biomechanics of the lumbar spine during ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.10.004
更新日期:2017-01-01 00:00:00
abstract::The addition of cryopreservative agents (CPAs) to chondrocytes and natural and engineered cartilage is critical to protect the cells and tissues from freezing damage during cryopreservation, but this may cause cell damage, e.g. by osmotic shock. The damage could be minimized by the control of the cell volume excursion...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(03)00073-0
更新日期:2003-09-01 00:00:00
abstract::Frozen clamps can hold tendons and ligaments tightly and transmit high loads, from 4 kN to 13 kN, without slippage, yet they are complex and expensive. The existing non-frozen serrated jaw clamp is simple to fabricate and use, but the maximal tensile force it can sustain is only about 2.5 kN, which is not enough in ma...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.11.019
更新日期:2012-05-01 00:00:00
abstract::The present study demonstrates the design, simulation, fabrication and testing of a label-free continuous manipulation and separation micro-device of particles/biological cells suspended on medium based on conventional dielectrophoresis. The current dielectrophoretic device uses three planner electrodes to generate no...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2013.12.010
更新日期:2014-06-01 00:00:00
abstract::Core decompression is the most common procedure for treatment of the early stages of osteonecrosis of the femoral head. The purpose of this study was to compare the biomechanical performance of four different bone graft substitutes combined with core decompression. Subject-specific finite element models generated from...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.05.008
更新日期:2016-09-01 00:00:00
abstract::Right ventricle ejection fraction (RVEF) is clinically used to evaluate right ventricular function. The thermodilution method can be modified to estimate the RVEF. However, this method requires a thermistor with a fast time response in order to yield correct estimates. Digital signal processing techniques that were de...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(02)00026-7
更新日期:2002-06-01 00:00:00
abstract::The present paper presents a homogenisation technique applied to the problem of calculating equivalent material properties of a resin impregnated wire mesh. Although this type of material can be expected to possess, in general, a four-fold axis of rotational symmetry, it was found that a transversally isotropic model ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(00)00065-5
更新日期:2000-09-01 00:00:00
abstract::Biodegradable materials have been generating increasing bit of interest in biomedical applications and associated research. The evolution of implants made up of such materials (Mg-alloys, etc.) has the potential to be a game changer in fracture surgeries. These implants are essentially made up of a plate and a number ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2020.05.010
更新日期:2020-07-01 00:00:00
abstract::Functional Electrical Stimulation (FES) is a well known clinical rehabilitation procedure, however the neural mechanisms that underlie this treatment at Central Nervous System (CNS) level are still not completely understood. Functional magnetic resonance imaging (fMRI) is a suitable tool to investigate effects of reha...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.04.005
更新日期:2011-10-01 00:00:00
abstract::To reduce the time of computation of a motor unit potential (MUP), the shape of intracellular action potential (IAP) and (or) MU anatomy are generally simplified. A method of MUP presentation is suggested. It provides accuracy of the MUPs calculated for any distance and size of rectangular electrodes together with con...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(98)00014-9
更新日期:1998-07-01 00:00:00
abstract::A kinematical model of the lower spine was designed and used to obtain a robust estimation of the vertebral rotations during torso movements from skin-surface markers recorded by video-cameras. Markers were placed in correspondence of the anatomical landmarks of the pelvic bone and vertebral spinous and transverse pro...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2004.08.005
更新日期:2004-12-01 00:00:00
abstract::Sequentially drilling multiple holes in bone is used clinically for surface preparation to aid in fusion of a joint, typically under non-irrigated conditions. Drilling induces a significant amount of heat and accumulates after multiple passes, which can result in thermal osteonecrosis and various complications. To und...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.06.002
更新日期:2015-09-01 00:00:00
abstract::Understanding the load mechanics of orthopaedic implants is important to be able to predict their behaviour in-vivo. Much research, both mechanical and clinical, has been carried out on hip and knee implants, but less has been written about the mechanics of wrist implants. In this paper, the load mechanics of the Univ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.02.008
更新日期:2016-06-01 00:00:00
abstract::Taper connections of modular hip prostheses are at risk of fretting and corrosion, which can result in reduced implant survival. The purpose of this study was to identify the minimum torque required to initiate a removal of the passivation layer at the taper interface as a function of assembly force and axial load. Ti...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.06.011
更新日期:2014-09-01 00:00:00
abstract::A flow model utilizing an irrotational, inviscid algorithm of vortex-ring elements simulating the leaflets and source/sink elements simulating the aortic root coupled with a boundary layer model has been developed to model the internal flow phenomena of bi-leaflet mechanical heart valves implanted in the aortic root. ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(95)00075-5
更新日期:1996-09-01 00:00:00
abstract::Electrochemotherapy (ECT) exploits the phenomenon of electroporation, which is the increase of cell permeability through the application of an electrical field. This technique is applied in medical centers in Europe and in veterinary clinics in Europe, Brazil, and Argentina. ECT treatment requires a minimum electric f...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.09.016
更新日期:2019-12-01 00:00:00
abstract::In case of large segmental defects in load-bearing bones, an external fixator is used to provide mechanical stability to the defect site. The overall stiffness of the bone-fixator system is determined not only by the fixator design but also by the way the fixator is mounted to the bone. This stiffness is an important ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2012.10.006
更新日期:2013-07-01 00:00:00
abstract:OBJECTIVE:To evaluate whether outcomes based on stopwatch time and power output (PO) over a 15m-overground wheelchair sprint test can be used to assess wheelchair-specific anaerobic work capacity, by studying their relationship with outcomes on a Wingate-based 30s-wheelchair ergometer sprint (WAnT). METHODS:Able-bodie...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.01.003
更新日期:2014-04-01 00:00:00
abstract::Total hip arthroplasty (THA) broaching involves impacting a broach handle with a mallet, facilitating force transmission to progress broaches into the femoral medullary canal. Limited surgical access during direct anterior THAs increases off-axis forces, potentially contributing to tissue damage. The aim was to charac...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.12.004
更新日期:2020-02-01 00:00:00
abstract::Three-dimensional surface imaging technologies have been used in the planning and evaluation of breast reconstructive and cosmetic surgery. The aim of this study was to develop a 3D surface imaging system based on the Microsoft Kinect and assess the accuracy and repeatability with which the system could image the brea...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2013.12.018
更新日期:2014-06-01 00:00:00
abstract::This paper presents a sensor for monitoring and controlling the volume of the cerebrospinal fluid-filled ventricles of the brain. The measurement principle of the sensor exploits electrical conductivity differences between the cerebrospinal fluid and the brain tissue. The electrical contrast was validated using dog br...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2009.03.011
更新日期:2009-09-01 00:00:00
abstract::Fetal movement is one index of fetal well-being. We designed and built a new recorder based on fetal movement acceleration measurement (FMAM). The FMAM recorder has a newly developed, capacitive acceleration sensor that can detect the oscillations of the maternal abdominal wall caused by fetal movements. In this study...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.09.001
更新日期:2012-06-01 00:00:00
abstract::Investigations into the effects of sterilization on a new biomechanical pressure sensor are necessary before contemplating in vivo use. Ten, designated Experimental, "K-Scan" digital pressure sensor arrays were sterilized with ethylene oxide gas (EtO), and their ability to accurately and reproducibly measure an applie...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(03)00119-x
更新日期:2003-11-01 00:00:00
abstract::Pressure ulcers are a major problem worldwide believed to affect over 5% of all hospital in-patients, and countless others in the community at large. Many types of Patient Support Systems (PSS) are sold as pressure ulcer prevention equipment, but no consensus exists as to their mechanical efficacy. The use of human vo...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(99)00053-3
更新日期:1999-06-01 00:00:00
abstract::Knowledge about the human skin mechanical properties is essential in several domains, particularly for dermatology, cosmetic or to detect some cutaneous pathology. This study proposes a new method to determine the human skin mechanical properties in vivo using the indentation test. Usually, the skin mechanical paramet...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2007.06.011
更新日期:2008-06-01 00:00:00
abstract::In robotic and conventional minimally invasive surgery the risk of complications caused by collateral tissue damage remains high. This paper studies the concept of imposing damage thresholds on surgical instruments to avoid tissue overload. More specifically, the correlation between mechanical loading and damage in ca...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2010.04.002
更新日期:2010-06-01 00:00:00