fMRI brain mapping during motion capture and FES induced motor tasks: signal to noise ratio assessment.

Abstract:

:Functional Electrical Stimulation (FES) is a well known clinical rehabilitation procedure, however the neural mechanisms that underlie this treatment at Central Nervous System (CNS) level are still not completely understood. Functional magnetic resonance imaging (fMRI) is a suitable tool to investigate effects of rehabilitative treatments on brain plasticity. Moreover, monitoring the effective executed movement is needed to correctly interpret activation maps, most of all in neurological patients where required motor tasks could be only partially accomplished. The proposed experimental set-up includes a 1.5 T fMRI scanner, a motion capture system to acquire kinematic data, and an electro-stimulation device. The introduction of metallic devices and of stimulation current in the MRI room could affect fMRI acquisitions so as to prevent a reliable activation maps analysis. What we are interested in is that the Blood Oxygenation Level Dependent (BOLD) signal, marker of neural activity, could be detected within a given experimental condition and set-up. In this paper we assess temporal Signal to Noise Ratio (SNR) as image quality index. BOLD signal change is about 1-2% as revealed by a 1.5 T scanner. This work demonstrates that, with this innovative set-up, in the main cortical sensorimotor regions 1% BOLD signal change can be detected at least in the 93% of the sub-volumes, and almost 100% of the sub-volumes are suitable for 2% signal change detection. The integrated experimental set-up will therefore allows to detect FES induced movements fMRI maps simultaneously with kinematic acquisitions so as to investigate FES-based rehabilitation treatments contribution at CNS level.

journal_name

Med Eng Phys

authors

Gandolla M,Ferrante S,Casellato C,Ferrigno G,Molteni F,Martegani A,Frattini T,Pedrocchi A

doi

10.1016/j.medengphy.2011.04.005

subject

Has Abstract

pub_date

2011-10-01 00:00:00

pages

1027-32

issue

8

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(11)00086-5

journal_volume

33

pub_type

杂志文章
  • Using robotic mechanical perturbations for enhanced balance assessment.

    abstract::Balance impairment is critical for many patient groups such as those with neural and musculoskeletal disorders and also the elderly. Accurate and objective assessment of balance performance has led to the development of several indices based on the measurement of the center of pressure. In this study, a robotic device...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.07.006

    authors: Baselizadeh A,Behjat A,Torabi A,Behzadipour S

    更新日期:2020-09-01 00:00:00

  • A method for determining the heat transfer and water vapour permeability of patient support systems.

    abstract::The formation of pressure ulcers can be exacerbated by a breakdown in the integrity of the patient's skin caused by poor maintenance of the skin microclimate. Patient support systems (PSSs-specialised beds, mattresses, chairs, cushions and pads) play an important role in the dissipation of heat and moisture away from ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00003-5

    authors: Nicholson GP,Scales JT,Clark RP,de Calcina-Goff ML

    更新日期:1999-12-01 00:00:00

  • Validation of three-dimensional model-based tibio-femoral tracking during running.

    abstract::The purpose of this study was to determine the accuracy of a radiographic model-based tracking technique that measures the three-dimensional in vivo motion of the tibio-femoral joint during running. Tantalum beads were implanted into the femur and tibia of three subjects and computed tomography (CT) scans were acquire...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2008.03.003

    authors: Anderst W,Zauel R,Bishop J,Demps E,Tashman S

    更新日期:2009-01-01 00:00:00

  • A fast responding combined direct and indirect calorimeter for human subjects.

    abstract::The construction and performance of a 5.4 m3 combined direct and indirect calorimeter for human subjects is described. The calorimeter was constructed for studies on human subjects primarily undergoing fast alterations in heat production and heat losses, e.g. after a meal or during physical exercise. A heat sink and a...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00037-x

    authors: Faber P,Lammert O,Johansen O,Garby L

    更新日期:1998-06-01 00:00:00

  • Loosening detection of the femoral component of hip prostheses with extracorporeal shockwaves: a pilot study.

    abstract::The diagnosis of aseptic loosening of hip implants is often challenging. A vibrational analysis of the bone-implant interface could be an alternative method to analyze the fixation of endoprostheses. We assessed an innovative and new approach for excitation by using extracorporeal shockwaves in this study. In three ca...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.11.011

    authors: Rieger JS,Jaeger S,Kretzer JP,Rupp R,Bitsch RG

    更新日期:2015-02-01 00:00:00

  • Recurrence quantification analysis as a tool for nonlinear exploration of nonstationary cardiac signals.

    abstract::The complexity, nonlinearity and nonstationarity of the cardiovascular system typically defy comprehensive and deterministic mathematical modeling, except from a statistical perspective. Living systems are governed by numerous, continuously changing, interacting variables in the presence of noise. Cardiovascular signa...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00112-6

    authors: Zbilut JP,Thomasson N,Webber CL

    更新日期:2002-01-01 00:00:00

  • Estimation of pulsatile cerebral arterial blood volume based on transcranial doppler signals.

    abstract:OBJECTIVE:Mathematical modeling of cerebral hemodynamics by descriptive equations can estimate the underlying pulsatile component of cerebral arterial blood volume (CaBV). This way, clinical monitoring of changes in cerebral compartmental compliances becomes possible. Our aim is to validate the most adequate method of ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.07.019

    authors: Calviello LA,Zeiler FA,Donnelly J,Uryga A,de Riva N,Smielewski P,Czosnyka M

    更新日期:2019-12-01 00:00:00

  • Enabling variable-stiffness hand rehabilitation orthoses with dielectric elastomer transducers.

    abstract::Patients affected by motor disorders of the hand and having residual voluntary movements of fingers or wrist can benefit from self-rehabilitation exercises performed with so-called dynamic hand splints. These systems consist of orthoses equipped with elastic cords or springs, which either provide a sustained stretch o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.10.015

    authors: Carpi F,Frediani G,Gerboni C,Gemignani J,De Rossi D

    更新日期:2014-02-01 00:00:00

  • Compressive and tensile properties of articular cartilage in axial loading are modulated differently by osmotic environment.

    abstract::Aims of the present study were to test the hypotheses that (1) the compressive properties of articular cartilage are affected more by changes in the medium ionic concentration than the tensile properties, (2) collagen network controls the compression-tension nonlinearity of articular cartilage, and (3) proteoglycan (P...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.11.004

    authors: Korhonen RK,Jurvelin JS

    更新日期:2010-03-01 00:00:00

  • Design and testing of a genetic algorithm neural network in the assessment of gait patterns.

    abstract::It is important to be able to quantify changes in gait pattern accurately in order to understand the clinical implications of surgery or rehabilitation. Although supervised feed-forward backpropagation neural networks are very efficient in many pattern-recognition tasks, the genetic algorithm neural network (GANN), wh...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00011-4

    authors: Su FC,Wu WL

    更新日期:2000-01-01 00:00:00

  • Preliminary observations on the presence of sustained tendon strain and eccentric contractions of the wrist extensors during a common manual task: implications for lateral epicondylitis.

    abstract::Lateral epicondylitis (LE) is hypothesized to occur as a result of repetitive, strenuous and abnormal postural activities of the elbow and wrist. There is still a lack of understanding of how wrist and forearm positions contribute to this condition during common manual tasks. In this study the wrist kinematics and the...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.02.002

    authors: Murgia A,Harwin W,Prakoonwit S,Brownlow H

    更新日期:2011-07-01 00:00:00

  • Influence of dual-task on sit-to-stand-to-sit postural control in Parkinson's disease.

    abstract::Postural control deficits are the most disabling aspects of Parkinson's disease (PD), resulting in decreased mobility and functional independence. The aim of this study was to assess the postural control stability, revealed by variables based on the centre of pressure (CoP), in individuals with PD while performing a s...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.08.011

    authors: Fernandes Â,Sousa AS,Couras J,Rocha N,Tavares JM

    更新日期:2015-11-01 00:00:00

  • Human body model response to mechanical impulse.

    abstract::Despite our understanding of the importance of falling, previous studies have ignored the effects of falls from standing height. In this article, lumped parameter linear and nonlinear models of a standing human have been used to simulate the impact response of the body segments due to inputs at the shoes. The accelera...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00081-1

    authors: Jarrah M,Qassem W,Othman M,Gdeisat M

    更新日期:1997-06-01 00:00:00

  • TETRA mobile radios interfere with electroencephalography recording equipment.

    abstract::We observed an anomaly in the human electroencephalogram (EEG) associated with exposure to terrestrial trunked radio (TETRA) Radiofrequency Fields (RF). Here, we characterize the time and frequency components of the anomaly and demonstrate that it is an artefact caused by TETRA RF interfering with the EEG recording eq...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.04.009

    authors: Fouquet NC,Hawken MB,Elliott P,Burgess AP

    更新日期:2013-11-01 00:00:00

  • Effect of specimen length: are the mechanics of individual motion segments comparable in functional spinal units and multisegment specimens?

    abstract::Functional spinal units (FSUs) are frequently used for in vitro mechanical testing. This approach assumes that the mechanical behavior of the FSUs is equivalent to the mechanics of these segments within the intact spine. The purpose of this study was to determine whether normal spinal mechanics are compromised in FSU ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00152-2

    authors: Dickey JP,Kerr DJ

    更新日期:2003-04-01 00:00:00

  • Comparison of the bending performance of solid and cannulated spinal pedicle screws using finite element analyses and biomechanical tests.

    abstract::Spinal pedicle screw fixations have been used extensively to treat fracture, tumor, infection, or degeneration of the spine. Cannulated spinal pedicle screws with bone cement augmentation might be a useful method to ameliorate screw loosening. However, cannulated spinal pedicle screws might also increase the risk of s...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.06.008

    authors: Shih KS,Hsu CC,Hou SM,Yu SC,Liaw CK

    更新日期:2015-09-01 00:00:00

  • Finite element prediction of surface strain and fracture strength at the distal radius.

    abstract::To better understand the mechanisms underlying distal radius fracture we have developed finite element models to predict radius bone strain and fracture strength under loading conditions simulating a fall. This study compares experimental surface strains and fracture loads of the distal radius with specimen-specific f...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.07.016

    authors: Edwards WB,Troy KL

    更新日期:2012-04-01 00:00:00

  • Effect of different inertial parameter sets on joint moment calculation during stair ascending and descending.

    abstract::The reliability of internal joint moment calculation in gait analysis during daily living activities is fundamental for clinical decisions based on joint function. This calculation, obtained by means of the inverse dynamics, depends on several modelling factors, such as assumptions on the segments and on the relevant ...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2004.12.002

    authors: Fantozzi S,Stagni R,Cappello A,Leardini A

    更新日期:2005-07-01 00:00:00

  • Finite-element design and optimization of a three-dimensional tetrahedral porous titanium scaffold for the reconstruction of mandibular defects.

    abstract::Reconstruction of segmental defects in the mandible remains a challenge for maxillofacial surgery. The use of porous scaffolds is a potential method for repairing these defects. Now, additive manufacturing techniques provide a solution for the fabrication of porous scaffolds with specific geometrical shapes and comple...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.06.015

    authors: Luo D,Rong Q,Chen Q

    更新日期:2017-09-01 00:00:00

  • Motor unit firing rates and synchronisation affect the fractal dimension of simulated surface electromyogram during isometric/isotonic contraction of vastus lateralis muscle.

    abstract::During fatiguing contractions, many adjustments in motor units behaviour occur: decrease in muscle fibre conduction velocity; increase in motor units synchronisation; modulation of motor units firing rate; increase in variability of motor units inter-spike interval. We simulated the influence of all these adjustments ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.09.022

    authors: Mesin L,Dardanello D,Rainoldi A,Boccia G

    更新日期:2016-12-01 00:00:00

  • Effects of sterilization on the Tekscan digital pressure sensor.

    abstract::Investigations into the effects of sterilization on a new biomechanical pressure sensor are necessary before contemplating in vivo use. Ten, designated Experimental, "K-Scan" digital pressure sensor arrays were sterilized with ethylene oxide gas (EtO), and their ability to accurately and reproducibly measure an applie...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(03)00119-x

    authors: Agins HJ,Harder VS,Lautenschlager EP,Kudrna JC

    更新日期:2003-11-01 00:00:00

  • Monolithic superelastic rods with variable flexural stiffness for spinal fusion: modeling of the processing-properties relationship.

    abstract::The concept of a monolithic Ti-Ni spinal rod with variable flexural stiffness is proposed to reduce the risks associated with spinal fusion. The variable stiffness is conferred to the rod using the Joule-heating local annealing technique. The annealing temperature and the mechanical properties' distributions resulted ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.07.012

    authors: Facchinello Y,Brailovski V,Petit Y,Mac-Thiong JM

    更新日期:2014-11-01 00:00:00

  • A multi-scale feedback ratio analysis of heartbeat interval series in healthy vs. cardiac patients.

    abstract::The second-order difference plot, as a modified Poincaré plot, is one of the important approaches for assessing the dynamics of heart rate variability. However, corresponding quantitative analysis methods are relatively limited. Based on the second-order difference plot, we propose a novel method, called the multi-sca...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.09.015

    authors: Huo C,Huang X,Ni H,Liu H,Bian C,Ning X

    更新日期:2014-12-01 00:00:00

  • Multi-adaptive filtering technique for surface somatosensory evoked potentials processing.

    abstract::Somatosensory evoked potential (SEP) testing has been widely applied to diagnosis of various neurological disorders. However, SEP recorded using surface electrodes is buried in noises, which makes the signal-to-noise ratio (SNR) very poor. Conventional averaging method usually requires up to thousands of raw SEP input...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.09.007

    authors: Lam BS,Hu Y,Lu WW,Luk KD,Chang CQ,Qiu W,Chan FH

    更新日期:2005-04-01 00:00:00

  • New product development processes within the UK medical device industry.

    abstract::This paper reports on the findings of an extensive survey investigating practising design engineers' perceptions of new product development within the UK medical device industry. The design activity recorded was predominantly the small-scale development of low volume products. Explicit formal procedures were rarely us...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00021-5

    authors: Glen JM,Lord M

    更新日期:1996-12-01 00:00:00

  • A microfluidic device for continuous manipulation of biological cells using dielectrophoresis.

    abstract::The present study demonstrates the design, simulation, fabrication and testing of a label-free continuous manipulation and separation micro-device of particles/biological cells suspended on medium based on conventional dielectrophoresis. The current dielectrophoretic device uses three planner electrodes to generate no...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.12.010

    authors: Das D,Biswas K,Das S

    更新日期:2014-06-01 00:00:00

  • Sensorized pacifier to evaluate non-nutritive sucking in newborns.

    abstract::We developed a device for an objective measurement of non-nutritive sucking (NNS). NNS is newborns' spontaneous action that is a predictor of their neural system development and can be adopted as an intervention to train oral feeding skills in preterms. Two miniaturized digital pressure sensors were embedded into a co...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.12.013

    authors: Grassi A,Cecchi F,Sgherri G,Guzzetta A,Gagliardi L,Laschi C

    更新日期:2016-04-01 00:00:00

  • Evaluation of four blood pump geometries: fluorescent particle flow visualisation technique.

    abstract::Artificial blood pumps play an increasingly important role in the treatment of end-stage cardiac failure. The fluid dynamics of blood flow through such devices crucially affects their clinical effectiveness. Specifically, if the flow of blood stagnates or slowly re-circulates thrombus formation can occur and the avoid...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00023-0

    authors: Rose ML,Mackay TG,Wheatley DJ

    更新日期:2000-04-01 00:00:00

  • Technical quality evaluation of EEG recording based on electroencephalographers' knowledge.

    abstract::The aim of this study is to develop a technical quality evaluation system of electroencephalogram (EEG) recording in order to acquire technically satisfactory EEG records, which may contribute to the accuracy improvement of EEG interpretation. In our developed system, the evaluation of EEG recording comprises the dete...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.09.001

    authors: Nakamura M,Chen Q,Sugi T,Ikeda A,Shibasaki H

    更新日期:2005-01-01 00:00:00

  • Grasping soft tissue by means of vacuum technique.

    abstract:INTRODUCTION:A notable characteristic of bariatric surgery is the frequent manipulation of the bowel. The bowel is large, delicate, flexible, and has a natural lubricant on the tissue surface. Therefore the bowel is difficult to grasp and manipulate. Vacuum technique is commonly used in industry for all types of graspi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.11.014

    authors: Vonck D,Jakimowicz JJ,Lopuhaä HP,Goossens RH

    更新日期:2012-10-01 00:00:00