Design and testing of a genetic algorithm neural network in the assessment of gait patterns.

Abstract:

:It is important to be able to quantify changes in gait pattern accurately in order to understand the clinical implications of surgery or rehabilitation. Although supervised feed-forward backpropagation neural networks are very efficient in many pattern-recognition tasks, the genetic algorithm neural network (GANN), which can search in some appropriate space, has not been used previously for gait-pattern recognition. This study discusses how to use the GANN approach in gait-pattern recognition, and evaluates the complexity and training strategy of the particular classification problem. Both the GANN and a traditional artificial neural network (ANN) were used to classify the gait patterns of patients with ankle arthrodesis and normal subjects. The GANN model was able to classify subjects with recognition rates of up to 98.7%. In contrast, the ANN trained by using all possible predictor variables was only able to classify the subjects with recognition rates of 89.7%. It is suggested that the GANN model is more suitable to exploit the patient's gait pattern. The value of the neuron output can be used as an index of the difference from normal. By this means, all pathological gait patterns may be presented quantitatively.

journal_name

Med Eng Phys

authors

Su FC,Wu WL

doi

10.1016/s1350-4533(00)00011-4

subject

Has Abstract

pub_date

2000-01-01 00:00:00

pages

67-74

issue

1

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(00)00011-4

journal_volume

22

pub_type

杂志文章
  • A 16-channel SQUID-device for biomagnetic investigations of small objects.

    abstract::Biomagnetic investigations in basic physiological research using animals require measurement devices different from commercial biomagnetometers used in human investigations. Two major problems have to be tackled in the design of such biomagnetometers. First, the spatial sampling needs to be much higher. Second, the di...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00088-0

    authors: Nowak H,Giessler F,Huonker R,Haueisen J,Röther J,Eiselt M

    更新日期:1999-10-01 00:00:00

  • In vivo soft tissue damage assessment for applications in surgery.

    abstract::In robotic and conventional minimally invasive surgery the risk of complications caused by collateral tissue damage remains high. This paper studies the concept of imposing damage thresholds on surgical instruments to avoid tissue overload. More specifically, the correlation between mechanical loading and damage in ca...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.04.002

    authors: Famaey N,Verbeken E,Vinckier S,Willaert B,Herijgers P,Vander Sloten J

    更新日期:2010-06-01 00:00:00

  • Evaluation of four blood pump geometries: fluorescent particle flow visualisation technique.

    abstract::Artificial blood pumps play an increasingly important role in the treatment of end-stage cardiac failure. The fluid dynamics of blood flow through such devices crucially affects their clinical effectiveness. Specifically, if the flow of blood stagnates or slowly re-circulates thrombus formation can occur and the avoid...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00023-0

    authors: Rose ML,Mackay TG,Wheatley DJ

    更新日期:2000-04-01 00:00:00

  • A biomechanical model to determine lumbosacral loads during single stance phase in normal gait.

    abstract::A dynamic biomechanical model to determine loads (joint forces) attained at the lumbosacral joint-centre during the stance phase of normal level walking was developed. The biomechanical model was based on rigid free body-segments; namely, the foot, shank, thigh, pelvis and head, arms and trunk (HAT) segments. In this ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)90374-k

    authors: Khoo BC,Goh JC,Bose K

    更新日期:1995-01-01 00:00:00

  • Assessment of gait sensitivity norm as a predictor of risk of falling during walking in a neuromusculoskeletal model.

    abstract::Quantifying the risk of falling (falls risk) would be helpful in treating people with gait disorders. The gait sensitivity norm (GSN) is a stability measure that correlates well to risk of falling in passive dynamic walkers but has not been evaluated on humans or human-like walking models. We assessed the correlation ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.03.018

    authors: Thangal SN,Talaty M,Balasubramanian S

    更新日期:2013-10-01 00:00:00

  • An impedance sensor to monitor and control cerebral ventricular volume.

    abstract::This paper presents a sensor for monitoring and controlling the volume of the cerebrospinal fluid-filled ventricles of the brain. The measurement principle of the sensor exploits electrical conductivity differences between the cerebrospinal fluid and the brain tissue. The electrical contrast was validated using dog br...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.03.011

    authors: Linninger A,Basati S,Dawe R,Penn R

    更新日期:2009-09-01 00:00:00

  • Detection of cardiac late potentials in nonstationary noise.

    abstract::An 'instantaneous' optimal filter is presented for improving the signal-to-noise ratio in averaged electrocardiograms (ECGs). The filter design is based on a simple model that accounts for correlation across the ensemble of beats but ignores correlation in time. Another property of the model is that the noise level is...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00069-0

    authors: Atarius R,Sörnmo L

    更新日期:1997-04-01 00:00:00

  • Personalized 3D reconstruction of the rib cage for clinical assessment of trunk deformities.

    abstract::Scoliosis is a 3D deformity of the spine and rib cage. Extensive validation of 3D reconstruction methods of the spine from biplanar radiography has already been published. In this article, we propose a novel method to reconstruct the rib cage, using the same biplanar views as for the 3D reconstruction of the spine, to...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.06.002

    authors: Grenier S,Parent S,Cheriet F

    更新日期:2013-11-01 00:00:00

  • A four-parameter linear model for analysing cardiorespiratory data in post-operative cardiac patients.

    abstract::This paper investigates the possibility of characterizing the differences between normal- and high-risk postoperative cardiac patients on the basis of four parameters related to a simple linear model of cardiorespiratory performances. The model comprises three subsystems representing cardiac, vascular and respiratory ...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/1350-4533(94)90073-6

    authors: Artioli E,Avanzolini G,Barbini P,Gnudi G

    更新日期:1994-11-01 00:00:00

  • Loosening detection of the femoral component of hip prostheses with extracorporeal shockwaves: a pilot study.

    abstract::The diagnosis of aseptic loosening of hip implants is often challenging. A vibrational analysis of the bone-implant interface could be an alternative method to analyze the fixation of endoprostheses. We assessed an innovative and new approach for excitation by using extracorporeal shockwaves in this study. In three ca...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.11.011

    authors: Rieger JS,Jaeger S,Kretzer JP,Rupp R,Bitsch RG

    更新日期:2015-02-01 00:00:00

  • Micro-CT evaluation of bone defects: applications to osteolytic bone metastases, bone cysts, and fracture.

    abstract::Bone defects can occur in various forms and present challenges to performing a standard micro-CT evaluation of bone quality because most measures are suited to homogeneous structures rather than ones with spatially focal abnormalities. Such defects are commonly associated with pain and fragility. Research involving bo...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.05.016

    authors: Buie HR,Bosma NA,Downey CM,Jirik FR,Boyd SK

    更新日期:2013-11-01 00:00:00

  • Fluid pressure driven fibril reinforcement in creep and relaxation tests of articular cartilage.

    abstract::Biological tissues exhibit diverse mechanical behaviors because of complex material properties. As has been shown for ligaments and intervertebral discs, mathematical models often appear to well predict load responses individually by adjusting model parameters, but likely fail to describe several different load respon...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.03.001

    authors: Li LP,Korhonen RK,Iivarinen J,Jurvelin JS,Herzog W

    更新日期:2008-03-01 00:00:00

  • Toward verified and validated FE simulations of a femur with a cemented hip prosthesis.

    abstract:BACKGROUND:Verified and validated CT-based high-order finite element (FE) methods were developed that predict accurately the mechanical response of patient-specific intact femurs. Here we extend these capabilities to human femurs undergoing a total hip replacement using cemented prostheses. METHODS:A fresh-frozen huma...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.09.007

    authors: Yosibash Z,Katz A,Milgrom C

    更新日期:2013-07-01 00:00:00

  • In vitro assessment of mitral valve function in cyclically pressurized porcine hearts.

    abstract::Recent approaches to the in vitro experimental study of cardiac fluid mechanics involve the use of whole biological structures to investigate in the lab novel therapeutic approaches for the treatment of heart pathologies. To enhance reliability and repeatability, the influence of the actuation strategy of the experime...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.01.007

    authors: Vismara R,Leopaldi AM,Piola M,Asselta C,Lemma M,Antona C,Redaelli A,van de Vosse F,Rutten M,Fiore GB

    更新日期:2016-04-01 00:00:00

  • Numerical analysis and experimental observation of guidewire motion in a blood vessel model.

    abstract::We have developed a computer-based system to simulate a guidewire in blood vessels for surgical planning, intra-operative assistance, and to facilitate the design of new guidewires. In this study, we compared simulation results with experimental results for validation of the simulation system. First, we inserted a com...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.09.012

    authors: Takashima K,Tsuzuki S,Ooike A,Yoshinaka K,Yu K,Ohta M,Mori K

    更新日期:2014-12-01 00:00:00

  • Reproducible metacarpal joint space width measurements using 3D analysis of images acquired with high-resolution peripheral quantitative computed tomography.

    abstract:OBJECTIVE:Joint space narrowing is an important feature of progressive joint damage and functional impairment in rheumatoid arthritis (RA). Methods to provide a continuous measurement of joint space width have not been adopted in research or clinical settings. High-resolution peripheral quantitative computed tomography...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.04.003

    authors: Barnabe C,Buie H,Kan M,Szabo E,Barr SG,Martin L,Boyd SK

    更新日期:2013-10-01 00:00:00

  • Application of higher order statistics/spectra in biomedical signals--a review.

    abstract::For many decades correlation and power spectrum have been primary tools for digital signal processing applications in the biomedical area. The information contained in the power spectrum is essentially that of the autocorrelation sequence; which is sufficient for complete statistical descriptions of Gaussian signals o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2010.04.009

    authors: Chua KC,Chandran V,Acharya UR,Lim CM

    更新日期:2010-09-01 00:00:00

  • A computational assessment of the hemodynamic effects of crossed and non-crossed bifurcated stent-graft devices for the treatment of abdominal aortic aneurysms.

    abstract::There are several issues attributed with abdominal aortic aneurysm endovascular repair. The positioning of bifurcated stent-grafts (SG) may affect SG hemodynamics. The hemodynamics and geometrical parameters of crossing or non-crossing graft limbs have not being totally accessed. Eight patient-specific SG devices and ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.09.011

    authors: Stefanov F,McGloughlin T,Morris L

    更新日期:2016-12-01 00:00:00

  • Morphology based anisotropic finite element models of the proximal femur validated with experimental data.

    abstract::Finite element analysis (FEA) of bones scanned with Quantitative Computed Tomography (QCT) can improve early detection of osteoporosis. The accuracy of these models partially depends on the assigned material properties, but anisotropy of the trabecular bone cannot be fully captured due to insufficient resolution of QC...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.08.010

    authors: Enns-Bray WS,Ariza O,Gilchrist S,Widmer Soyka RP,Vogt PJ,Palsson H,Boyd SK,Guy P,Cripton PA,Ferguson SJ,Helgason B

    更新日期:2016-11-01 00:00:00

  • Assessment of four statistical pattern recognition techniques to assist in obstructive sleep apnoea diagnosis from nocturnal oximetry.

    abstract::The aim of this study is to assess the utility of traditional statistical pattern recognition techniques to help in obstructive sleep apnoea (OSA) diagnosis. Classifiers based on quadratic (QDA) and linear (LDA) discriminant analysis, K-nearest neighbours (KNN) and logistic regression (LR) were evaluated. Spectral and...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.05.010

    authors: Marcos JV,Hornero R,Alvarez D,del Campo F,Zamarrón C

    更新日期:2009-10-01 00:00:00

  • How measurement artifacts affect cerebral autoregulation outcomes: A technical note on transfer function analysis.

    abstract::Cerebral autoregulation (CA) is the mechanism that aims to maintain adequate cerebral perfusion during changes in blood pressure (BP). Transfer function analysis (TFA), the most reported method in literature to quantify CA, shows large between-study variability in outcomes. The aim of this study is to investigate the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.02.001

    authors: Meel-van den Abeelen AS,de Jong DL,Lagro J,Panerai RB,Claassen JA

    更新日期:2016-05-01 00:00:00

  • Computational fluid dynamic simulations of cavopulmonary connections with an extracardiac lateral conduit.

    abstract::Complex congenital heart defects due to the absence of a ventricular chamber can often be treated by the Fontan surgical procedure. The objective of this work was to quantify the haemodynamics in the Fontan operation (cavopulmonary connection) with extracardiac lateral conduit. Four different models based on the finit...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00042-9

    authors: Migliavacca F,de Leval MR,Dubini G,Pietrabissa R,Fumero R

    更新日期:1999-04-01 00:00:00

  • Motion analysis in delirium: a discrete approach in determining physical activity for the purpose of delirium motoric subtyping.

    abstract::The purpose of this study was to determine the use and feasibility of accelerometry-based monitoring and to examine a discrete multi-resolution signal analysis technique to determine motoric subtypes in patients with DSM-IV delirium. Forty consecutive patients receiving palliative care (23 male, 17 female, mean age+/-...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2009.10.012

    authors: Godfrey A,Conway R,Leonard M,Meagher D,Olaighin GM

    更新日期:2010-03-01 00:00:00

  • In vitro model of intravenous fluid administration: analysis of vein resistance to rapid fluid delivery.

    abstract::Rapid fluid administration is the cornerstone of successful trauma resuscitation of patients in a state of shock. Intravenous (IV) fluid delivery is a physical intrusion into a vein which results in a complex interaction between the rigid catheter and the compliant vein. We present an experimental model of IV infusion...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00046-1

    authors: Yaniv S,Halpern P,Aladgem D,Zaretsky U,Elad D

    更新日期:2000-07-01 00:00:00

  • Validated computational framework for efficient systematic evaluation of osteoporotic fracture fixation in the proximal humerus.

    abstract::The high rate of fixation failure in osteoporotic proximal humerus fractures indicate the need for improved solutions. Computer simulations may help to overcome the limitations of the gold standard biomechanical testing in evaluating the performance of new implants and enhance the effectivity and outcome of the design...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.04.011

    authors: Varga P,Inzana JA,Gueorguiev B,Südkamp NP,Windolf M

    更新日期:2018-07-01 00:00:00

  • A decentralized adaptive fuzzy robust strategy for control of upright standing posture in paraplegia using functional electrical stimulation.

    abstract::In this paper, we present a novel decentralized robust methodology for control of quiet upright posture during arm-free paraplegic standing using functional electrical stimulation (FES). Each muscle-joint complex is considered as a subsystem and individual controllers are designed for each one. Each controller operate...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.06.013

    authors: Kobravi HR,Erfanian A

    更新日期:2012-01-01 00:00:00

  • Electrochemistry of nanoscale DNA surface films on carbon.

    abstract::A DNA electrochemical biosensor is an integrated receptor-transducer device. The most important step in the development and manufacture of a sensitive DNA-biosensor for the detection of DNA-drug interactions is the immobilization procedure of the nucleic acid probe on the transducer surface. Magnetic A/C Mode atomic f...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2006.05.009

    authors: Oliveira-Brett AM,Paquim AM,Diculescu VC,Piedade JA

    更新日期:2006-12-01 00:00:00

  • A novel ultrasonic aerosol generator.

    abstract::An ultrasonic aerosol generator constructed from a domestic humidifier is described which has been used to produce liquid aerosols for physiological investigations. The instrument was constructed from a Pifco domestic humidifier modified to include an energy guide to direct the oscillations of the transducer through t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)97320-o

    authors: Davies A,Hudson N,Pirie L

    更新日期:1995-07-01 00:00:00

  • Reliability, validity, and precision of an active stereophotogrammetry system for three-dimensional evaluation of the human torso.

    abstract::To determine the reliability, stability, validity and precision of a stereophotogrammetry (SP) system for use in quantifying the complex three-dimensional structure of the human torso, we performed assessments of the system using images of geometric solids and a human-form mannequin. Analysis of geometric solids revea...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.08.011

    authors: Paul SM,Chamberlin AP,Hatt C,Nayak AV,Danoff JV

    更新日期:2009-12-01 00:00:00

  • In-vitro validation of a non-invasive dual fluoroscopic imaging technique for measurement of the hip kinematics.

    abstract::Measurement of accurate in vivo hip joint kinematics in 6-DOF is difficult. Few studies have reported non-invasive measurements of the hip kinematics. The objective of this study was to validate a non-invasive dual fluoroscopic imaging system (DFIS) for measurement of hip kinematics. Bi-lateral hip joints of a cadaver...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.10.004

    authors: Lin H,Wang S,Tsai TY,Li G,Kwon YM

    更新日期:2013-03-01 00:00:00