Abstract:
:Rapid fluid administration is the cornerstone of successful trauma resuscitation of patients in a state of shock. Intravenous (IV) fluid delivery is a physical intrusion into a vein which results in a complex interaction between the rigid catheter and the compliant vein. We present an experimental model of IV infusion into a vein-like compliant tube that (a) demonstrated the interdependence between fluid administration and blood flow in a compliant tube and (b) allowed investigation of the contribution of the central venous system (between the infusion site and the heart) to the total resistance to infusion flow rate. The results show that in cases with very high resistance in the central venous system a significant increase of infusion flow rate cannot be achieved just by increasing the infusion pressure. Similarly, in cases of small veins when only small catheters can be used, infusate flow rate may be increased only by using two independent infusion ports. In cases with increased tissue pressure due to edema, gravity-driven infusion may not produce sufficient perfusion of the vascular compartments. It was also shown that the vein valves do not always close, and that peripheral blood flow may continue together with the infusate fluid (e.g., when there is a small downstream resistance and infusion with a small catheter).
journal_name
Med Eng Physjournal_title
Medical engineering & physicsauthors
Yaniv S,Halpern P,Aladgem D,Zaretsky U,Elad Ddoi
10.1016/s1350-4533(00)00046-1subject
Has Abstractpub_date
2000-07-01 00:00:00pages
395-404issue
6eissn
1350-4533issn
1873-4030pii
S1350-4533(00)00046-1journal_volume
22pub_type
杂志文章abstract::Lung cancer is the most common cause of cancer-related death, and early detection can reduce the mortality rate. Patients with lung nodules greater than 10 mm usually undergo a computed tomography (CT)-guided biopsy. However, aligning the needle with the target is difficult and the needle tends to deflect from a strai...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2017.04.009
更新日期:2017-07-01 00:00:00
abstract::The impeller blood pump with its simplicity has many advantages compared with the diaphragm pump, but the nonpulsatile property has limited its applications. To make the impeller pump pulsatile, many investigations have been made in vain because of resulting haemolysis. The author has succeeded in producing a pulsatil...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(95)00010-0
更新日期:1996-01-01 00:00:00
abstract::Intraoperative thermographic imaging in open-chest conditions can provide the surgeon with important qualitative information regarding coronary flow by utilizing heat transfer analysis following injection of cold saline into the aortic root. The heat transfer model is based on the assumption that the epicardial temper...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(98)00040-x
更新日期:1998-09-01 00:00:00
abstract::The objective of this work is to develop a robust method for human abdominal aortic aneurysm (AAA) centerline detection that can contribute to the accurate computation of features for the prediction of AAA rupture risk. A semiautomatic algorithm is proposed for detecting the lumen centerline in contrast-enhanced abdom...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2013.03.005
更新日期:2013-09-01 00:00:00
abstract::The temperature at which collagen denatures from a triple helix to a random coil structure is a useful measure of the degree of crosslinking. A new multi-sample denaturation temperature tester (DTT) has been constructed for rapid determination of the collagen denaturation temperature of natural tissues and collagenous...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(95)91882-h
更新日期:1995-03-01 00:00:00
abstract::Recent research has indicated that consumers of upper limb prostheses desire lighter-weight, anthropomorphic devices. The potential of dielectric elastomer (DE) actuators to better meet the design priorities of prosthesis users is explored. Current challenges are critically reviewed with respect to (1) durability, (2)...
journal_title:Medical engineering & physics
pub_type: 杂志文章,评审
doi:10.1016/j.medengphy.2007.05.011
更新日期:2008-05-01 00:00:00
abstract::Airway stents improve pulmonary function and quality of life in patients suffering from airway obstruction. The aim of this study was to compare main types of stents (silicone, balloon-dilated metal, self-expanding metal, and covered self-expanding metal) in terms of their mechanical properties and the radial forces t...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.02.008
更新日期:2015-04-01 00:00:00
abstract::Different probes are used in dermato-cosmetic research to measure the electrical properties of the skin. The principle governing the choice of the geometry and material of the measuring probe is not well defined in the literature and some device's measuring principles are not accessible for the scientific community. T...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2012.02.008
更新日期:2012-12-01 00:00:00
abstract::A ligamentous, nonlinear, sliding contact, three-dimensional finite element (FE) model of L2-L3 complex was developed to investigate the biomechanical effect of laminectomy with and without facetectomy. The L2-L3 FE model was validated against experimental study under various physiological loadings and found to match ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2003.11.006
更新日期:2004-04-01 00:00:00
abstract::Finite element (FE) models of the proximal femur are often used to study hip fracture. To interpret the results of these models, it is important to know whether the models accurately predict fracture location and/or type. This study evaluated the ability of automatically generated, CT scan-based linear FE models of th...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(01)00094-7
更新日期:2001-11-01 00:00:00
abstract::Some pulmonary diseases and injuries are believed to correlate with lung viscoelasticity changes. Hence, a better understanding of lung viscoelastic models could provide new perspectives on the progression of lung pathology and trauma. In the presented study, stress relaxation measurements were performed to quantify r...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.05.003
更新日期:2015-08-01 00:00:00
abstract::Pedicle screw loosening is still observed in clinical practice. Therefore, the understanding of the interaction between screw and bone is evermore subject of research. However, complex relationships between screw design and anchorage are rarely examined. For this reason, it is investigated whether screw fixation is pr...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2020.03.001
更新日期:2020-05-01 00:00:00
abstract::The majority of the eye models developed in the late 90s and early 00s considers only heat conduction inside the eye. This assumption is not entirely correct, since the anterior and posterior chambers are filled aqueous humor (AH) that is constantly in motion due to thermally-induced buoyancy. In this paper, a three-d...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.05.011
更新日期:2016-08-01 00:00:00
abstract::The BION (Bionic Neuron) is a single channel implantable neurostimulator of unique design that can be delivered by injection. The development of the BION injectable neurostimulators exemplifies a challenging, but well posed medical design problem addressed with a successful strategy for prioritizing and resolving the ...
journal_title:Medical engineering & physics
pub_type: 杂志文章,评审
doi:10.1016/j.medengphy.2010.08.010
更新日期:2011-01-01 00:00:00
abstract::This study aimed at developing a method for automated electrocardiography (ECG) artifact detection and removal from trunk electromyography signals. Independent Component Analysis (ICA) method was applied to the simulated data set of ECG-corrupted surface electromyography (SEMG) signals. Independent Components (ICs) co...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2010.05.007
更新日期:2010-10-01 00:00:00
abstract::This paper presents a parametric mathematical model of the head-cup wear coupling in total hip arthroplasty (THA). The model evaluates the dependence of acetabular volumetric wear upon the characteristic parameters of patient and hip prosthesis. Archard's law is assumed to calculate the wear coupling behaviour. The we...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(98)00004-6
更新日期:1998-04-01 00:00:00
abstract::A few finite element models have addressed the dynamic juxtaarticular stress transmission but none focused the investigation on the combined influence of the individual moduli of the underlying bones, including the subchondral plate, the femoral head and the femoral neck of the proximal femur. A finite element model i...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2004.12.008
更新日期:2005-05-01 00:00:00
abstract::The deformation of soft tissue compromises the accuracy of image-guided surgery based on preoperative images, and restricts its applicability to surgery on or near bony structures. One way to overcome these limitations is to combine biomechanical models with sparse intraoperative data, in order to realistically warp t...
journal_title:Medical engineering & physics
pub_type: 杂志文章,评审
doi:10.1016/j.medengphy.2005.10.005
更新日期:2005-12-01 00:00:00
abstract::Truly representative architectural parameters of trabeculea can be extremely difficult to achieve based on scanning images because of variable porosity and distribution of trabeculae within the specific overall scanned volume of bone. Accordingly, in present study different selective volume of interests, measured from...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.01.014
更新日期:2011-07-01 00:00:00
abstract::Right ventricle ejection fraction (RVEF) is clinically used to evaluate right ventricular function. The thermodilution method can be modified to estimate the RVEF. However, this method requires a thermistor with a fast time response in order to yield correct estimates. Digital signal processing techniques that were de...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(02)00026-7
更新日期:2002-06-01 00:00:00
abstract::Small spaces make collision-free turns difficult for wheelchair users. Contrary to basic kinematic wheelchair modelling and not considered previously by engineers; when wheelchairs turn in small spaces, could lateral drift (sideways slipping) increase the risk of collisions with surrounding structures such as walls an...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2020.11.012
更新日期:2021-01-01 00:00:00
abstract::The present investigation was conducted to see the effect of subcutaneous fat on the transmission characteristics of an electrical stimulus applied to the skin and conducted to skeletal muscle. Two groups of subjects participated. In one, the subjects were three males and three females whose average age was 24.6+/-1.5...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2008.02.009
更新日期:2008-11-01 00:00:00
abstract::In case of large segmental defects in load-bearing bones, an external fixator is used to provide mechanical stability to the defect site. The overall stiffness of the bone-fixator system is determined not only by the fixator design but also by the way the fixator is mounted to the bone. This stiffness is an important ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2012.10.006
更新日期:2013-07-01 00:00:00
abstract::The prerequisite for the continuous in vivo monitoring of glucose concentration is the development of an implantable glucose sensor with long-term stability. A new enzyme electrode concept featuring fluid-state glucose oxidase modified carbon powder along with a cross-linked glucose oxidase enzyme layer has been devel...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(90)90008-v
更新日期:1994-09-01 00:00:00
abstract::Gastric contractions play an important role in the digestive process of the stomach. The established method for the measurement of gastric contractions is invasive and involves the insertion through the nose of a manometric probe into the stomach. A non-invasive method is introduced in this paper for the identificatio...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(95)95713-k
更新日期:1995-04-01 00:00:00
abstract::The second-order difference plot, as a modified Poincaré plot, is one of the important approaches for assessing the dynamics of heart rate variability. However, corresponding quantitative analysis methods are relatively limited. Based on the second-order difference plot, we propose a novel method, called the multi-sca...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.09.015
更新日期:2014-12-01 00:00:00
abstract::In this manuscript we describe the development and testing of a bipolar electrode for the simultaneous acquisition of ultrasound (US) images and surface electromyograms (EMGs) from the same muscle region. The developed electrode (bEMG-US) consists of two circular sensing regions (20 mm diameter) with fixed inter-elect...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2018.12.002
更新日期:2019-02-01 00:00:00
abstract::Our main goal was to test various impedance methods for measuring body composition in adolescents with anorexia nervosa (AN) during refeeding therapy. A specific objective was to compare the information provided by a foot-to-foot impedancemeter (FFI) with that supplied by a medical multifrequency impedancemeter and by...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2007.09.005
更新日期:2008-07-01 00:00:00
abstract::A portable, lightweight home ankle exerciser was designed and built by the Biomedical Engineering Department of University Hospital in London, Ontario, Canada. The ankle exerciser incorporates several unique features that overcomes the drawbacks of exercise equipment presently available. For optimal muscle strengtheni...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(95)00057-7
更新日期:1996-06-01 00:00:00
abstract::Dynamic models of the human trunk have been extensively used to investigate the biomechanics of lower back pain and postural instability in different populations. Despite their diverse applications, previous models rely on intrinsic upper body segment parameters (UBSP), e.g., each segment's mass-inertia characteristic...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2010.09.008
更新日期:2011-01-01 00:00:00