How measurement artifacts affect cerebral autoregulation outcomes: A technical note on transfer function analysis.

Abstract:

:Cerebral autoregulation (CA) is the mechanism that aims to maintain adequate cerebral perfusion during changes in blood pressure (BP). Transfer function analysis (TFA), the most reported method in literature to quantify CA, shows large between-study variability in outcomes. The aim of this study is to investigate the role of measurement artifacts in this variation. Specifically, the role of distortion in the BP and/or CBFV measurementon TFA outcomes was investigated. The influence of three types of artifacts on TFA outcomes was studied: loss of signal, motion artifacts, and baseline drifts. TFA metrics of signals without the simulated artifacts were compared with those of signals with artifacts. TFA outcomes scattered highly when more than 10% of BP signal or over 8% of the CBFV signal was lost, or when measurements contained one or more artifacts resulting from head movement. Furthermore, baseline drift affected interpretation of TFA outcomes when the power in the BP signal was 5 times the power in the LF band. In conclusion, loss of signal in BP and loss in CBFV, affects interpretation of TFA outcomes. Therefore, it is vital to validate signal quality to the defined standards before interpreting TFA outcomes.

journal_name

Med Eng Phys

authors

Meel-van den Abeelen AS,de Jong DL,Lagro J,Panerai RB,Claassen JA

doi

10.1016/j.medengphy.2016.02.001

subject

Has Abstract

pub_date

2016-05-01 00:00:00

pages

490-7

issue

5

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(16)00035-7

journal_volume

38

pub_type

杂志文章
  • Recurrence quantification analysis as a tool for nonlinear exploration of nonstationary cardiac signals.

    abstract::The complexity, nonlinearity and nonstationarity of the cardiovascular system typically defy comprehensive and deterministic mathematical modeling, except from a statistical perspective. Living systems are governed by numerous, continuously changing, interacting variables in the presence of noise. Cardiovascular signa...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00112-6

    authors: Zbilut JP,Thomasson N,Webber CL

    更新日期:2002-01-01 00:00:00

  • Including aortic valve morphology in computational fluid dynamics simulations: initial findings and application to aortic coarctation.

    abstract::Computational fluid dynamics (CFD) simulations quantifying thoracic aortic flow patterns have not included disturbances from the aortic valve (AoV). 80% of patients with aortic coarctation (CoA) have a bicuspid aortic valve (BAV) which may cause adverse flow patterns contributing to morbidity. Our objectives were to d...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.07.015

    authors: Wendell DC,Samyn MM,Cava JR,Ellwein LM,Krolikowski MM,Gandy KL,Pelech AN,Shadden SC,LaDisa JF Jr

    更新日期:2013-06-01 00:00:00

  • Comparison of isotropic and orthotropic material property assignments on femoral finite element models under two loading conditions.

    abstract::CT data has been widely used in the finite element modeling of bone. It can provide useful information on the geometrical topology and material properties of bone. Based on CT data, the assignment of bone material properties to finite element meshes is a fundamental step in the model generation. Most work done in this...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.06.003

    authors: Peng L,Bai J,Zeng X,Zhou Y

    更新日期:2006-04-01 00:00:00

  • Writing through a robot: a proof of concept for a brain-machine interface.

    abstract::This paper describes a non-invasive human brain-actuated robotic arm experiment, which allows remote writing. In the local environment, the participant decides on an arbitrary word to transmit. A mental speller interface is then used to select the letters. A robot arm placed in the remote environment writes the word o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.06.005

    authors: Pérez-Marcos D,Buitrago JA,Velásquez FD

    更新日期:2011-12-01 00:00:00

  • Sensitivity analysis of the position of the intervertebral centres of reaction in upright standing--a musculoskeletal model investigation of the lumbar spine.

    abstract::The loads between adjacent vertebrae can be generalised as a single spatial force acting at the intervertebral centre of reaction. The exact position in vivo is unknown. However, in rigid body musculoskeletal models that simulate upright standing, the position is generally assumed to be located at the discs' centres o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.12.003

    authors: Zander T,Dreischarf M,Schmidt H

    更新日期:2016-03-01 00:00:00

  • Dynamic properties of human incudostapedial joint-Experimental measurement and finite element modeling.

    abstract::The incudostapedial joint (ISJ) is a synovial joint connecting the incus and stapes in the middle ear. Mechanical properties of the ISJ directly affect sound transmission from the tympanic membrane to the cochlea. However, how ISJ properties change with frequency has not been investigated. In this paper, we report the...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.02.006

    authors: Jiang S,Gan RZ

    更新日期:2018-04-01 00:00:00

  • Analysis of the effects of surface stiffness on the contact interaction between a finger and a cylindrical handle using a three-dimensional hybrid model.

    abstract::Contact interactions between the hand and handle, such as the contact surface softness and contact surface curvature, will affect both physical effort and musculoskeletal fatigue, thereby the comfort and safety of power tool operations. Previous models of hand gripping can be categorized into two groups: multi-body dy...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.03.007

    authors: Wu JZ,Dong RG,Warren CM,Welcome DE,McDowell TW

    更新日期:2014-07-01 00:00:00

  • Laser fabrication of electrical feedthroughs in polymer encapsulations for active implantable medical devices.

    abstract::Hermetic electrical feedthroughs are essential for safe and functional active implantable biomedical devices and for a wide range of other applications such as batteries, supercapacitors, OLEDs and solar cells. Ceramics and metals have previously been the materials of choice for encapsulations, while polymers have adv...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.01.010

    authors: Gough Z,Chaminade C,Barclay-Monteith P,Kallinen A,Lei W,Ganesan R,Grace J,McKenzie DR

    更新日期:2017-04-01 00:00:00

  • The formation and function of the sclerosis rim in the femoral head: A biomechanical point of view.

    abstract::Sclerosis rim surrounding the necrotic area is commonly found in necrotic femoral head, but the biomechanical function of sclerosis rim has received relatively little attention. Little is known about the formation and natural history of sclerosis rim. In the present work, we assume that the necrotic change may trigger...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.09.005

    authors: Chen Z,Xu Y,Qi Z,Zho J

    更新日期:2015-12-01 00:00:00

  • Particle image velocimetry study of the celiac trunk hemodynamic induced by continuous-flow left ventricular assist device.

    abstract::Whereas left ventricular assist device (LVAD) is the gold-standard therapy for patients with heart failure, gastrointestinal bleeding is one of the most common complications. LVAD implantation may remarkably impact aortic hemodynamics so that experimental and computational flow analyses can be used to study the diseas...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.06.029

    authors: Scardulla F,Bellavia D,D'Acquisto L,Raffa GM,Pasta S

    更新日期:2017-09-01 00:00:00

  • Toward verified and validated FE simulations of a femur with a cemented hip prosthesis.

    abstract:BACKGROUND:Verified and validated CT-based high-order finite element (FE) methods were developed that predict accurately the mechanical response of patient-specific intact femurs. Here we extend these capabilities to human femurs undergoing a total hip replacement using cemented prostheses. METHODS:A fresh-frozen huma...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.09.007

    authors: Yosibash Z,Katz A,Milgrom C

    更新日期:2013-07-01 00:00:00

  • Dynamic cerebral autoregulation assessment using an ARX model: comparative study using step response and phase shift analysis.

    abstract::Middle cerebral arterial blood velocity (MCAv) response to spontaneous and manipulated changes of arterial blood pressure (ABP) was studied in eight subjects using a linear autoregressive with exogenous input (ARX) model. ABP and MCAv were measured non-invasively by photoplethysmograph and transcranial Doppler ultraso...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/s1350-4533(03)00015-8

    authors: Liu Y,Birch AA,Allen R

    更新日期:2003-10-01 00:00:00

  • An MRI compatible loading device for the reconstruction of clinically relevant plantar pressure distributions and loading scenarios of the forefoot.

    abstract::The purpose of this study is to demonstrate a new MRI compatible loading device capable of reconstructing realistic loading scenarios of the human foot for research in the field of foot biomechanics. This device has two different configurations: one used to compress the forefoot and one to bend the metatarsophalangeal...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.06.006

    authors: Chatzistergos PE,Naemi R,Chockalingam N

    更新日期:2014-09-01 00:00:00

  • LES of non-Newtonian physiological blood flow in a model of arterial stenosis.

    abstract::Large Eddy Simulation (LES) is performed to study the physiological pulsatile transition-to-turbulent non-Newtonian blood flow through a 3D model of arterial stenosis by using five different blood viscosity models: (i) Power-law, (ii) Carreau, (iii) Quemada, (iv) Cross and (v) modified-Casson. The computational domain...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.11.013

    authors: Molla MM,Paul MC

    更新日期:2012-10-01 00:00:00

  • Computation of the elastic properties of a resin impregnated wire mesh by the means of a homogenisation procedure.

    abstract::The present paper presents a homogenisation technique applied to the problem of calculating equivalent material properties of a resin impregnated wire mesh. Although this type of material can be expected to possess, in general, a four-fold axis of rotational symmetry, it was found that a transversally isotropic model ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00065-5

    authors: Hübsch PF,Middleton J,Knox J

    更新日期:2000-09-01 00:00:00

  • Quantitative characterisation of impaction events during femoral broaching in total hip arthroplasty.

    abstract::Total hip arthroplasty (THA) broaching involves impacting a broach handle with a mallet, facilitating force transmission to progress broaches into the femoral medullary canal. Limited surgical access during direct anterior THAs increases off-axis forces, potentially contributing to tissue damage. The aim was to charac...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.12.004

    authors: Preutenborbeck M,Reuter J,Ferrari E

    更新日期:2020-02-01 00:00:00

  • Segmentation of magnetic resonance images using a combination of neural networks and active contour models.

    abstract::Segmentation of medical images is very important for clinical research and diagnosis, leading to a requirement for robust automatic methods. This paper reports on the combined use of a neural network (a multilayer perceptron, MLP) and active contour model ('snake') to segment structures in magnetic resonance (MR) imag...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/s1350-4533(03)00137-1

    authors: Middleton I,Damper RI

    更新日期:2004-01-01 00:00:00

  • Probabilistic analysis of an uncemented total hip replacement.

    abstract::This paper describes the application of probabilistic design methods to the analysis of the behaviour of an uncemented total hip replacement femoral component implanted in a proximal femur. Probabilistic methods allow variations in factors which control the behaviour of the implanted femur (the input parameters) to be...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.01.002

    authors: Dopico-González C,New AM,Browne M

    更新日期:2009-05-01 00:00:00

  • Influence of antegrade pulmonary blood flow on the hemodynamic performance of bidirectional cavopulmonary anastomosis: a numerical study.

    abstract::The role and effect of preserved antegrade pulmonary blood flow (APBF) at the time of bidirectional cavopulmonary anastomosis (BCPA) in the management of single-ventricle physiology is controversial. We investigated the influence of APBF on the fluid dynamics of BCPA connection using computational fluid dynamics (CFD)...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.07.004

    authors: Sun Q,Wan D,Liu J,Liu Y,Zhu M,Hong H,Sun Y,Wang Q

    更新日期:2009-03-01 00:00:00

  • A numerical investigation into the influence of the properties of cobalt chrome cellular structures on the load transfer to the periprosthetic femur following total hip arthroplasty.

    abstract::Stress shielding of the periprosthetic femur following total hip arthroplasty is a problem that can promote the premature loosening of femoral stems. In order to reduce the need for revision surgery it is thought that more flexible implant designs need to be considered. In this work, the mechanical properties of laser...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.02.008

    authors: Hazlehurst KB,Wang CJ,Stanford M

    更新日期:2014-04-01 00:00:00

  • A computational assessment of the hemodynamic effects of crossed and non-crossed bifurcated stent-graft devices for the treatment of abdominal aortic aneurysms.

    abstract::There are several issues attributed with abdominal aortic aneurysm endovascular repair. The positioning of bifurcated stent-grafts (SG) may affect SG hemodynamics. The hemodynamics and geometrical parameters of crossing or non-crossing graft limbs have not being totally accessed. Eight patient-specific SG devices and ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.09.011

    authors: Stefanov F,McGloughlin T,Morris L

    更新日期:2016-12-01 00:00:00

  • A mathematical model of the impact response of the seated subject.

    abstract::A model of the lumbar spine, pelvis and buttocks is developed, based on linear horizontal and vertical systems along with a rotational subsystem. The model can mimic qualitatively different experimental observations of transmission of vibrations from the seat to L3 in the sitting posture. It is concluded that while th...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)00062-3

    authors: Broman H,Pope M,Hansson T

    更新日期:1996-07-01 00:00:00

  • Flexible impulse transfer using a Newton's Cradle-inspired catheter: A feasibility study.

    abstract::A major challenge during minimally invasive surgery is transfer of high forces through small, flexible instruments, such as needles and catheters, because of their low buckling resistance. In this study, we determined the feasibility of using a Newton's Cradle-inspired catheter (patented) to transfer high-force impuls...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.12.025

    authors: Sakes A,Grandia L,Lether R,Steenstra L,Valentijn MC,Breedveld P,Spronck JW

    更新日期:2019-05-01 00:00:00

  • On the secondary stability of coated cementless hip replacement: parameters that affected interface strength.

    abstract::Unlike primary stability of coated cementless implants, their secondary stability has been poorly studied. This paper considers some theoretical aspects of the secondary stability of a coated cementless hip implant in a human femur. The bone is separated from the implant by a thin layer of microscopic peaks and trough...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(03)00099-7

    authors: Orlik J,Zhurov A,Middleton J

    更新日期:2003-12-01 00:00:00

  • Evaluation of the role of ligaments, facets and disc nucleus in lower cervical spine under compression and sagittal moments using finite element method.

    abstract::Cervical spinal instability due to ligamentous injury, degenerated disc and facetectomy is a subject of great controversy. There is no analytical investigation reported on the biomechanical response of cervical spine in these respects. Parametric study on the roles of ligaments, facets, and disc nucleus of human lower...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00036-4

    authors: Teo EC,Ng HW

    更新日期:2001-04-01 00:00:00

  • Effects of mechanical loading on the profile of human femoral diaphyseal geometry.

    abstract::In vivo bone behaviour predictions with respect to altered loading conditions, implants, and endoprostheses are highly desirable to avoid untoward effects such as implant loosening and breakage. This knowledge does not relate only to the result but also to the mechanisms of bone adaptation and bone growth. Since bone ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(94)90014-0

    authors: Mittlmeier T,Mattheck C,Dietrich F

    更新日期:1994-01-01 00:00:00

  • Clinical workflow for personalized foot pressure ulcer prevention.

    abstract::Foot pressure ulcers are a common complication of diabetes because of patient's lack of sensitivity due to neuropathy. Deep pressure ulcers appear internally when pressures applied on the foot create high internal strains nearby bony structures. Monitoring tissue strains in persons with diabetes is therefore important...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.04.017

    authors: Bucki M,Luboz V,Perrier A,Champion E,Diot B,Vuillerme N,Payan Y

    更新日期:2016-09-01 00:00:00

  • A noncontact resonance frequency detection technique for the assessment of the interfacial bone defect around a dental implant.

    abstract::This study employed a noncontact resonance frequency (RF) detection technique that was developed by our group to evaluate the interfacial bone in in vitro implant-bone models. Based on our method, the implant-bone structure was excited by the acoustic energy of a loudspeaker, and its vibration response was acquired wi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.05.006

    authors: Pan MC,Zhuang HB,Chen CS,Wu JW,Lee SY

    更新日期:2013-12-01 00:00:00

  • In-vitro validation of a non-invasive dual fluoroscopic imaging technique for measurement of the hip kinematics.

    abstract::Measurement of accurate in vivo hip joint kinematics in 6-DOF is difficult. Few studies have reported non-invasive measurements of the hip kinematics. The objective of this study was to validate a non-invasive dual fluoroscopic imaging system (DFIS) for measurement of hip kinematics. Bi-lateral hip joints of a cadaver...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.10.004

    authors: Lin H,Wang S,Tsai TY,Li G,Kwon YM

    更新日期:2013-03-01 00:00:00

  • In vivo soft tissue damage assessment for applications in surgery.

    abstract::In robotic and conventional minimally invasive surgery the risk of complications caused by collateral tissue damage remains high. This paper studies the concept of imposing damage thresholds on surgical instruments to avoid tissue overload. More specifically, the correlation between mechanical loading and damage in ca...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.04.002

    authors: Famaey N,Verbeken E,Vinckier S,Willaert B,Herijgers P,Vander Sloten J

    更新日期:2010-06-01 00:00:00