An MRI compatible loading device for the reconstruction of clinically relevant plantar pressure distributions and loading scenarios of the forefoot.

Abstract:

:The purpose of this study is to demonstrate a new MRI compatible loading device capable of reconstructing realistic loading scenarios of the human foot for research in the field of foot biomechanics. This device has two different configurations: one used to compress the forefoot and one to bend the metatarsophalangeal joints. Required plantar pressure distribution under the metatarsal heads can be achieved by modifying the distribution of the dorsally applied forces. To validate the device, subject-specific plantar pressures were measured and then reconstructed using the device. For quiet stance the peak pressure reconstruction error was 3% while for mid-stance phase of gait it was 8%. The device was also used to measure the passive bending stiffness of the metatarsophalangeal joints of one subject with low intra-subject variability. A series of preliminary MRI scans confirmed that the loading device can be used to produce static weight-bearing images of the foot (voxel size: 0.23 mm × 0.23 mm × 1.00 mm). The results indicate that the device presented here can accurately reconstruct subject specific plantar pressure distributions and measure the foot's metatarsophalangeal passive stiffness. Possible future applications include the validation of finite element models, the investigation of the relationship between plantar pressure and internal stresses/strains and the study of the foot's inter-segmental passive stiffness.

journal_name

Med Eng Phys

authors

Chatzistergos PE,Naemi R,Chockalingam N

doi

10.1016/j.medengphy.2014.06.006

subject

Has Abstract

pub_date

2014-09-01 00:00:00

pages

1205-11

issue

9

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(14)00146-5

journal_volume

36

pub_type

杂志文章
  • Modelization of a self-opening peripheral neural interface: a feasibility study.

    abstract::In this paper a self-opening intrafascicular neural interface (SELINE) has been modeled using both a theoretical approach and a Finite Element (FE) analysis. This innovative self opening interface has several potential advantages such as: higher selectivity due to its three-dimensional structure and efficient anchorag...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.06.001

    authors: Cutrone A,Sergi PN,Bossi S,Micera S

    更新日期:2011-12-01 00:00:00

  • Precise and fast calculation of the motor unit potentials detected by a point and rectangular plate electrode.

    abstract::To reduce the time of computation of a motor unit potential (MUP), the shape of intracellular action potential (IAP) and (or) MU anatomy are generally simplified. A method of MUP presentation is suggested. It provides accuracy of the MUPs calculated for any distance and size of rectangular electrodes together with con...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00014-9

    authors: Dimitrov GV,Dimitrova NA

    更新日期:1998-07-01 00:00:00

  • Investigation to predict patellar tendon reflex using motion analysis technique.

    abstract::The investigation of patellar tendon reflex involves development of a reflex hammer holder, kinematic data collection and analysis of patellar reflex responses using motion analysis techniques. The main aim of this research is to explore alternative means of assessing reflexes as a part of routine clinical diagnosis. ...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2010.11.002

    authors: Tham LK,Osman NA,Lim KS,Pingguan-Murphy B,Abas WA,Zain NM

    更新日期:2011-05-01 00:00:00

  • Writing through a robot: a proof of concept for a brain-machine interface.

    abstract::This paper describes a non-invasive human brain-actuated robotic arm experiment, which allows remote writing. In the local environment, the participant decides on an arbitrary word to transmit. A mental speller interface is then used to select the letters. A robot arm placed in the remote environment writes the word o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.06.005

    authors: Pérez-Marcos D,Buitrago JA,Velásquez FD

    更新日期:2011-12-01 00:00:00

  • Functional evaluation of natural sensory feedback incorporated in a hand grasp neuroprosthesis.

    abstract::We investigated whether automatic control of a hand grasp neuroprosthesis by means of signals from natural sensors in the skin of the index finger can mimic the natural control of grasp force in an important task of daily living, namely eating. We designed a simulated eating task with the same ratio of rest and activi...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2004.03.002

    authors: Inmann A,Haugland M

    更新日期:2004-07-01 00:00:00

  • Wheelchair integrated occupant restraints: feasibility in frontal impact.

    abstract::Individuals often use their wheelchair as a motor vehicle seat when traveling in motor vehicles. The current use of fixed vehicle-mounted wheelchair occupant restraint systems (FWORSs) often results in poor belt fit and discomfort. Additionally, satisfaction, usability and usage rate of FWORSs during transit use are o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00082-0

    authors: VanRoosmalen L,Bertocci GE,Ha D,Karg P

    更新日期:2001-12-01 00:00:00

  • Computational analysis on the mechanical interaction between a thrombus and red blood cells: possible causes of membrane damage of red blood cells at microvessels.

    abstract::Previous studies investigating thrombus formation have not focused on the physical interaction between red blood cells (RBCs) and thrombus, although they have been speculated that some pathological conditions such as microangiopathic hemolytic anemia (MAHA) stem from interactions between RBCs and thrombi. In this stud...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.01.003

    authors: Kamada H,Imai Y,Nakamura M,Ishikawa T,Yamaguchi T

    更新日期:2012-12-01 00:00:00

  • Gabor frames for classification of paroxysmal and persistent atrial fibrillation episodes.

    abstract::In this study, we propose a new classification method for early differentiation of paroxysmal and persistent atrial fibrillation episodes, i.e. those which spontaneously or with external intervention will return to sinus rhythm within 7 days of onset from the ones where the arrhythmia is sustained for more than 7 days...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.10.013

    authors: Ortigosa N,Galbis A,Fernández C,Cano Ó

    更新日期:2017-01-01 00:00:00

  • Development of tissue adhesion method using integrated low-level energies.

    abstract::We have developed a method that allows biological tissues to be adhered together with minimal invasion by delivering integrated low-level energies from heat, pressure, and vibration. Tensile tests on adhered slices of porcine aorta were performed to determine the relationships between adhesive strength and conditions ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.12.005

    authors: Katoh A,Masuzawa T,Ozeki K,Kishida A,Kimura T,Higami T

    更新日期:2010-05-01 00:00:00

  • Finite element stress analysis of a hybrid fracture fixation plate.

    abstract::Metal plates are commonly used in the operative treatment of bone fractures. Rigid metal plates stabilize the fracture site, maintain good contact between bone fragments and allow early weight bearing and patient mobility. However, treatment with rigid metal plates can cause localized bone atrophy due to stress-shield...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)00041-0

    authors: Ferguson SJ,Wyss UP,Pichora DR

    更新日期:1996-04-01 00:00:00

  • A decentralized adaptive fuzzy robust strategy for control of upright standing posture in paraplegia using functional electrical stimulation.

    abstract::In this paper, we present a novel decentralized robust methodology for control of quiet upright posture during arm-free paraplegic standing using functional electrical stimulation (FES). Each muscle-joint complex is considered as a subsystem and individual controllers are designed for each one. Each controller operate...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.06.013

    authors: Kobravi HR,Erfanian A

    更新日期:2012-01-01 00:00:00

  • Liquid ventilation: a mathematical model of gas diffusion in the premature lung.

    abstract::The liquid ventilation (LV) technique was previously demonstrated to be a valuable alternative to ordinary gas ventilation, particularly for newborn patients with severely distressed lungs. This work describes a mathematical model of gas transfer phenomena occurring within the lungs of a preterm newborn baby ventilate...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00041-0

    authors: Costantino ML,Fiore GB

    更新日期:1997-03-01 00:00:00

  • Wear of polyethylene cups in total hip arthroplasty: a parametric mathematical model.

    abstract::This paper presents a parametric mathematical model of the head-cup wear coupling in total hip arthroplasty (THA). The model evaluates the dependence of acetabular volumetric wear upon the characteristic parameters of patient and hip prosthesis. Archard's law is assumed to calculate the wear coupling behaviour. The we...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00004-6

    authors: Pietrabissa R,Raimondi M,Di Martino E

    更新日期:1998-04-01 00:00:00

  • Porcine carotid arterial material property alterations with induced atheroma: an in vivo study.

    abstract:OBJECTIVE:A novel methodology has been developed to evaluate regional alterations in arterial wall material properties with induced atheroma in an animal model. METHODS:Atheromatous lesions (fatty, fibro-fatty, and fibrous) were induced in the carotid arteries of a Yucatan miniswine model by endothelial cell denudatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.09.014

    authors: Nagaraj A,Kim H,Hamilton AJ,Mun JH,Smulevitz B,Kane BJ,Yan LL,Roth SI,McPherson DD,Chandran KB

    更新日期:2005-03-01 00:00:00

  • The influence of mechanical properties of subchondral plate, femoral head and neck on dynamic stress distribution of the articular cartilage.

    abstract::A few finite element models have addressed the dynamic juxtaarticular stress transmission but none focused the investigation on the combined influence of the individual moduli of the underlying bones, including the subchondral plate, the femoral head and the femoral neck of the proximal femur. A finite element model i...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.12.008

    authors: Wei HW,Sun SS,Jao SH,Yeh CR,Cheng CK

    更新日期:2005-05-01 00:00:00

  • Prediction of ground reaction force and joint moments based on optical motion capture data during gait.

    abstract::The standard camera- and force plate-based set-up for motion analysis suffers from the disadvantage of being limited to laboratory settings. Since adaptive algorithms are able to learn the connection between known inputs and outputs and generalise this knowledge to unknown data, these algorithms can be used to leverag...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.10.001

    authors: Mundt M,Koeppe A,David S,Bamer F,Potthast W,Markert B

    更新日期:2020-12-01 00:00:00

  • Influence of antegrade pulmonary blood flow on the hemodynamic performance of bidirectional cavopulmonary anastomosis: a numerical study.

    abstract::The role and effect of preserved antegrade pulmonary blood flow (APBF) at the time of bidirectional cavopulmonary anastomosis (BCPA) in the management of single-ventricle physiology is controversial. We investigated the influence of APBF on the fluid dynamics of BCPA connection using computational fluid dynamics (CFD)...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.07.004

    authors: Sun Q,Wan D,Liu J,Liu Y,Zhu M,Hong H,Sun Y,Wang Q

    更新日期:2009-03-01 00:00:00

  • Three-dimensional localisation based on projectional and tomographic image correlation: an application for digital tomosynthesis.

    abstract::Accurate three-dimensional tumor localisation in Radiotherapy, is critical to the treatment outcome, particularly when high dose gradients are present. A number of techniques have been proposed for the localisation of anatomical structures or markers. The present study proposes an approach to a concurrent maximisation...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00015-6

    authors: Messaris G,Kolitsi Z,Badea C,Pallikarakis N

    更新日期:1999-03-01 00:00:00

  • Arbitrary waveform constant current stimulator for long-term wearable applications.

    abstract::Subsensory electrical noise stimulation has been shown to improve sensory perception in humans. However, the majority of this work has been limited to the laboratory due to unavailability of portable body-worn stimulators. In this paper, we present a robust and reliable stimulator, engineered for wearable applications...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.04.001

    authors: Breen PP,Serrador JM,Gargiulo GD

    更新日期:2019-06-01 00:00:00

  • Is respiratory sinus arrhythmia present in atrial fibrillation? A study using two quantitative methods.

    abstract::Two quantitative techniques have been evaluated to examine whether respiratory sinus arrhythmia can be detected in atrial fibrillation. Cyclical changes in heart rate during deep breathing indicating respiratory sinus arrhythmia were seen in 11/15 control patients, but only 1/44 patients with atrial fibrillation. Powe...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/1350-4533(94)90061-2

    authors: Chandler ST,Trewby PN

    更新日期:1994-07-01 00:00:00

  • A novel integrated mechanomyogram-vocalization access solution.

    abstract::We introduce a novel dual-switch control paradigm based on the simultaneous measurement of frontalis muscle mechanomyography (MMG) and vocalizations (humming) using a single contact microphone attached to the forehead. Vibrations of the face and skull during vocalization are manifested as periodic high-frequency compo...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.06.003

    authors: Alves N,Falk TH,Chau T

    更新日期:2010-10-01 00:00:00

  • Robust infrarenal aortic aneurysm lumen centerline detection for rupture status classification.

    abstract::The objective of this work is to develop a robust method for human abdominal aortic aneurysm (AAA) centerline detection that can contribute to the accurate computation of features for the prediction of AAA rupture risk. A semiautomatic algorithm is proposed for detecting the lumen centerline in contrast-enhanced abdom...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.03.005

    authors: Zhang H,Kheyfets VO,Finol EA

    更新日期:2013-09-01 00:00:00

  • Resonant frequency analysis of dental implants.

    abstract::Dental implant stability influences the decision on the determination of the duration between implant insertion and loading. This work investigates the resonant frequency analysis by means of a numerical model. The investigation is done numerically through the determination of the eigenfrequencies and performing stead...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.02.008

    authors: Rittel D,Dorogoy A,Haïat G,Shemtov-Yona K

    更新日期:2019-04-01 00:00:00

  • Computation of the elastic properties of a resin impregnated wire mesh by the means of a homogenisation procedure.

    abstract::The present paper presents a homogenisation technique applied to the problem of calculating equivalent material properties of a resin impregnated wire mesh. Although this type of material can be expected to possess, in general, a four-fold axis of rotational symmetry, it was found that a transversally isotropic model ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00065-5

    authors: Hübsch PF,Middleton J,Knox J

    更新日期:2000-09-01 00:00:00

  • Computer simulation of commercial conductive gels and their application to increase the safety of electrochemotherapy treatment.

    abstract::Electrochemotherapy (ECT) exploits the phenomenon of electroporation, which is the increase of cell permeability through the application of an electrical field. This technique is applied in medical centers in Europe and in veterinary clinics in Europe, Brazil, and Argentina. ECT treatment requires a minimum electric f...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.09.016

    authors: Pintarelli GB,Berkenbrock JA,Rassele A,Rangel MMM,Suzuki DOH

    更新日期:2019-12-01 00:00:00

  • Thermographic imaging in the beating heart: a method for coronary flow estimation based on a heat transfer model.

    abstract::Intraoperative thermographic imaging in open-chest conditions can provide the surgeon with important qualitative information regarding coronary flow by utilizing heat transfer analysis following injection of cold saline into the aortic root. The heat transfer model is based on the assumption that the epicardial temper...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00040-x

    authors: Gordon N,Rispler S,Sideman S,Shofty R,Beyar R

    更新日期:1998-09-01 00:00:00

  • A method for the extraction of an object from a noisy background.

    abstract::The removal of the background from a noisy image to leave the object of interest, with well defined edges, is a difficult task. Images obtained using radioisotopes have low signal-to-noise ratios due to scattered photons, as well as emitted radiation from the background. Moreover, noise is, also, a consequence of the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)00043-7

    authors: Livieratos GN,Chappell PH

    更新日期:1996-03-01 00:00:00

  • A numerical hemodynamic tool for predictive vascular surgery.

    abstract::We suggest a new approach to peripheral vascular bypass surgery planning based on solving the one-dimensional (1D) governing equations of blood flow in patient-specific models. The aim of the present paper is twofold. First, we present the coupled 1D-0D model based on a discontinuous Galerkin method in a comprehensive...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.04.015

    authors: Marchandise E,Willemet M,Lacroix V

    更新日期:2009-01-01 00:00:00

  • Sensitivity analysis of the position of the intervertebral centres of reaction in upright standing--a musculoskeletal model investigation of the lumbar spine.

    abstract::The loads between adjacent vertebrae can be generalised as a single spatial force acting at the intervertebral centre of reaction. The exact position in vivo is unknown. However, in rigid body musculoskeletal models that simulate upright standing, the position is generally assumed to be located at the discs' centres o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.12.003

    authors: Zander T,Dreischarf M,Schmidt H

    更新日期:2016-03-01 00:00:00

  • Dynamic behavior of tripolar hip endoprostheses under physiological conditions and their effect on stability.

    abstract::Tripolar systems have been implanted to reduce the risk of recurrent dislocation. However, there is little known about the dynamic behavior of tripolar hip endoprostheses under daily life conditions and achieved joint stability. Hence, the objective of this biomechanical study was to examine the in vivo dynamics and d...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.09.007

    authors: Fabry C,Kaehler M,Herrmann S,Woernle C,Bader R

    更新日期:2014-01-01 00:00:00