Prediction of ground reaction force and joint moments based on optical motion capture data during gait.

Abstract:

:The standard camera- and force plate-based set-up for motion analysis suffers from the disadvantage of being limited to laboratory settings. Since adaptive algorithms are able to learn the connection between known inputs and outputs and generalise this knowledge to unknown data, these algorithms can be used to leverage motion analysis outside the laboratory. In most biomechanical applications, feedforward neural networks are used, although these networks can only work on time normalised data, while recurrent neural networks can be used for real time applications. Therefore, this study compares the performance of these two kinds of neural networks on the prediction of ground reaction force and joint moments of the lower limbs during gait based on joint angles determined by optical motion capture as input data. The accuracy of both networks when generalising to new data was assessed using the normalised root-mean-squared error, the root-mean-squared error and the correlation coefficient as evaluation metrics. Both neural networks demonstrated a high performance and good capabilities to generalise to new data. The mean prediction accuracy over all parameters applying a feedforward network was higher (r = 0.963) than using a recurrent long short-term memory network (r = 0.935).

journal_name

Med Eng Phys

authors

Mundt M,Koeppe A,David S,Bamer F,Potthast W,Markert B

doi

10.1016/j.medengphy.2020.10.001

subject

Has Abstract

pub_date

2020-12-01 00:00:00

pages

29-34

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(20)30149-1

journal_volume

86

pub_type

杂志文章
  • A computational assessment of the hemodynamic effects of crossed and non-crossed bifurcated stent-graft devices for the treatment of abdominal aortic aneurysms.

    abstract::There are several issues attributed with abdominal aortic aneurysm endovascular repair. The positioning of bifurcated stent-grafts (SG) may affect SG hemodynamics. The hemodynamics and geometrical parameters of crossing or non-crossing graft limbs have not being totally accessed. Eight patient-specific SG devices and ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.09.011

    authors: Stefanov F,McGloughlin T,Morris L

    更新日期:2016-12-01 00:00:00

  • Prediction of fracture location in the proximal femur using finite element models.

    abstract::Finite element (FE) models of the proximal femur are often used to study hip fracture. To interpret the results of these models, it is important to know whether the models accurately predict fracture location and/or type. This study evaluated the ability of automatically generated, CT scan-based linear FE models of th...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00094-7

    authors: Keyak JH,Rossi SA,Jones KA,Les CM,Skinner HB

    更新日期:2001-11-01 00:00:00

  • Improving the detection of evoked responses to periodic stimulation by using bivariate local spectral F-test - Application to EEG during photic stimulation.

    abstract::The spectral local F-test has been applied for detecting evoked responses to rhythmic stimulation that are embedded in the ongoing electroencephalogram (EEG). Based on the sampling distribution of a flat spectrum at the neighbourhood of the stimulation frequency, spectral peaks in an EEG signal that are due to the sti...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.06.032

    authors: Felix LB,Rocha PF,Mendes EMAM,Miranda de Sá AMFL

    更新日期:2017-10-01 00:00:00

  • Finite-element design and optimization of a three-dimensional tetrahedral porous titanium scaffold for the reconstruction of mandibular defects.

    abstract::Reconstruction of segmental defects in the mandible remains a challenge for maxillofacial surgery. The use of porous scaffolds is a potential method for repairing these defects. Now, additive manufacturing techniques provide a solution for the fabrication of porous scaffolds with specific geometrical shapes and comple...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.06.015

    authors: Luo D,Rong Q,Chen Q

    更新日期:2017-09-01 00:00:00

  • The effects of flute shape and thread profile on the insertion torque and primary stability of dental implants.

    abstract::Easy insertion of the implant and stable bone purchase is essential for an ideal dental implantation. At the implant tip, the cutting flutes and conical profile are respectively designed to reduce insertion resistance and facilitate the initial insertion. However, the tapered tip might reduce the self-tapping and bone...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.09.021

    authors: Wu SW,Lee CC,Fu PY,Lin SC

    更新日期:2012-09-01 00:00:00

  • Probabilistic analysis of an uncemented total hip replacement.

    abstract::This paper describes the application of probabilistic design methods to the analysis of the behaviour of an uncemented total hip replacement femoral component implanted in a proximal femur. Probabilistic methods allow variations in factors which control the behaviour of the implanted femur (the input parameters) to be...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.01.002

    authors: Dopico-González C,New AM,Browne M

    更新日期:2009-05-01 00:00:00

  • Using robotic mechanical perturbations for enhanced balance assessment.

    abstract::Balance impairment is critical for many patient groups such as those with neural and musculoskeletal disorders and also the elderly. Accurate and objective assessment of balance performance has led to the development of several indices based on the measurement of the center of pressure. In this study, a robotic device...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.07.006

    authors: Baselizadeh A,Behjat A,Torabi A,Behzadipour S

    更新日期:2020-09-01 00:00:00

  • Nintendo® Wii Fit based sleepiness tester detects impairment of postural steadiness due to 24 h of wakefulness.

    abstract::A field-usable sleepiness tester could reduce sleepiness related accidents. 15 subjects' postural steadiness was measured with a Nintendo(®) Wii Fit balance board every hour for 24 h. Body sway was quantified with complexity index, CI, and the correlation between CI and alertness predicted by a three-process model of ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.08.007

    authors: Tietäväinen A,Gates FK,Meriläinen A,Mandel JE,Hæggström E

    更新日期:2013-12-01 00:00:00

  • Computational fluid dynamic simulations of cavopulmonary connections with an extracardiac lateral conduit.

    abstract::Complex congenital heart defects due to the absence of a ventricular chamber can often be treated by the Fontan surgical procedure. The objective of this work was to quantify the haemodynamics in the Fontan operation (cavopulmonary connection) with extracardiac lateral conduit. Four different models based on the finit...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00042-9

    authors: Migliavacca F,de Leval MR,Dubini G,Pietrabissa R,Fumero R

    更新日期:1999-04-01 00:00:00

  • Validity of using wearable inertial sensors for assessing the dynamics of standing balance.

    abstract::Observational balance tests (e.g., Berg Balance Scale) are used to evaluate fall-risk. However, they tend to be subjective, and their reliability and sensitivity can be limited. The use of in-lab equipment for objective balance evaluation has not been common in clinical practice, due to the requirement of an equipped ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.10.018

    authors: Noamani A,Nazarahari M,Lewicke J,Vette AH,Rouhani H

    更新日期:2020-03-01 00:00:00

  • Numerical analysis and experimental observation of guidewire motion in a blood vessel model.

    abstract::We have developed a computer-based system to simulate a guidewire in blood vessels for surgical planning, intra-operative assistance, and to facilitate the design of new guidewires. In this study, we compared simulation results with experimental results for validation of the simulation system. First, we inserted a com...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.09.012

    authors: Takashima K,Tsuzuki S,Ooike A,Yoshinaka K,Yu K,Ohta M,Mori K

    更新日期:2014-12-01 00:00:00

  • Computer simulation of commercial conductive gels and their application to increase the safety of electrochemotherapy treatment.

    abstract::Electrochemotherapy (ECT) exploits the phenomenon of electroporation, which is the increase of cell permeability through the application of an electrical field. This technique is applied in medical centers in Europe and in veterinary clinics in Europe, Brazil, and Argentina. ECT treatment requires a minimum electric f...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.09.016

    authors: Pintarelli GB,Berkenbrock JA,Rassele A,Rangel MMM,Suzuki DOH

    更新日期:2019-12-01 00:00:00

  • Comparison of isotropic and orthotropic material property assignments on femoral finite element models under two loading conditions.

    abstract::CT data has been widely used in the finite element modeling of bone. It can provide useful information on the geometrical topology and material properties of bone. Based on CT data, the assignment of bone material properties to finite element meshes is a fundamental step in the model generation. Most work done in this...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.06.003

    authors: Peng L,Bai J,Zeng X,Zhou Y

    更新日期:2006-04-01 00:00:00

  • A microfluidic device for continuous manipulation of biological cells using dielectrophoresis.

    abstract::The present study demonstrates the design, simulation, fabrication and testing of a label-free continuous manipulation and separation micro-device of particles/biological cells suspended on medium based on conventional dielectrophoresis. The current dielectrophoretic device uses three planner electrodes to generate no...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.12.010

    authors: Das D,Biswas K,Das S

    更新日期:2014-06-01 00:00:00

  • Finite element stress analysis of a hybrid fracture fixation plate.

    abstract::Metal plates are commonly used in the operative treatment of bone fractures. Rigid metal plates stabilize the fracture site, maintain good contact between bone fragments and allow early weight bearing and patient mobility. However, treatment with rigid metal plates can cause localized bone atrophy due to stress-shield...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)00041-0

    authors: Ferguson SJ,Wyss UP,Pichora DR

    更新日期:1996-04-01 00:00:00

  • Grasping soft tissue by means of vacuum technique.

    abstract:INTRODUCTION:A notable characteristic of bariatric surgery is the frequent manipulation of the bowel. The bowel is large, delicate, flexible, and has a natural lubricant on the tissue surface. Therefore the bowel is difficult to grasp and manipulate. Vacuum technique is commonly used in industry for all types of graspi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.11.014

    authors: Vonck D,Jakimowicz JJ,Lopuhaä HP,Goossens RH

    更新日期:2012-10-01 00:00:00

  • Development and validation of an improved mechanical thorax for simulating cardiopulmonary resuscitation with adjustable chest stiffness and simulated blood flow.

    abstract::Investigations of compressive frequency, duty cycle, or waveform during CPR are typically rooted in animal research or computer simulations. Our goal was to generate a mechanical model incorporating alternate stiffness settings and an integrated blood flow system, enabling defined, reproducible comparisons of CPR effi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.02.005

    authors: Eichhorn S,Spindler J,Polski M,Mendoza A,Schreiber U,Heller M,Deutsch MA,Braun C,Lange R,Krane M

    更新日期:2017-05-01 00:00:00

  • Exploiting parameter sparsity in model-based reconstruction to accelerate proton density and T(2) mapping.

    abstract::T2 mapping is a powerful noninvasive technique providing quantitative biological information of the inherent tissue properties. However, its clinical usage is limited due to the relative long scanning time. This paper proposed a novel model-based method to address this problem. Typically, we directly estimated the rel...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.06.002

    authors: Peng X,Liu X,Zheng H,Liang D

    更新日期:2014-11-01 00:00:00

  • An external portable device for adaptive deep brain stimulation (aDBS) clinical research in advanced Parkinson's Disease.

    abstract::Compared to conventional deep brain stimulation (DBS) for patients with Parkinson's Disease (PD), the newer approach of adaptive DBS (aDBS), regulating stimulation on the basis of the patient's clinical state, promises to achieve better clinical outcomes, avoid adverse-effects and save time for tuning parameters. A re...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.02.007

    authors: Arlotti M,Rossi L,Rosa M,Marceglia S,Priori A

    更新日期:2016-05-01 00:00:00

  • Effects of consecutive slips in nerve signals recorded by implanted cuff electrode.

    abstract::Using an anaesthetized cat's central footpad pressed against an object as the model of a paralyzed human hand, a nerve signal recording system was developed to measure the effect of a group of consecutive slips between the footpad and the object. Electroneurographic (ENG) activity was recorded using a cuff electrode i...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.05.007

    authors: Tong KY,Rong W,Li L,Cao J

    更新日期:2008-05-01 00:00:00

  • Intramedullary femoral nails: one or two lag screws? A preliminary study.

    abstract::Failures of proximal femoral nails that treat unstable femoral fractures have been reported. In this communication, a finite element model to include a proximal femoral nail within a fractured femur was used to carry out preliminary investigations into configurations of single or double lag screws. The effects of the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00081-3

    authors: Wang CJ,Brown CJ,Yettram AL,Procter P

    更新日期:2000-11-01 00:00:00

  • In vitro assessment of mitral valve function in cyclically pressurized porcine hearts.

    abstract::Recent approaches to the in vitro experimental study of cardiac fluid mechanics involve the use of whole biological structures to investigate in the lab novel therapeutic approaches for the treatment of heart pathologies. To enhance reliability and repeatability, the influence of the actuation strategy of the experime...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.01.007

    authors: Vismara R,Leopaldi AM,Piola M,Asselta C,Lemma M,Antona C,Redaelli A,van de Vosse F,Rutten M,Fiore GB

    更新日期:2016-04-01 00:00:00

  • Comparison of calibration methods for accelerometers used in human motion analysis.

    abstract::In the fields of medicine and biomechanics, MEMS accelerometers are increasingly used to perform activity recognition by directly measuring acceleration; to calculate speed and position by numerical integration of the signal; or to estimate the orientation of body parts in combination with gyroscopes. For some of thes...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2016.08.004

    authors: Nez A,Fradet L,Laguillaumie P,Monnet T,Lacouture P

    更新日期:2016-11-01 00:00:00

  • Determination of backrest inclination based on biodynamic response study for prevention of low back pain.

    abstract::Whole-body vibration experiments with subjects under vertical vibration were performed to examine and evaluate effects of backrest inclination on vibration transmitted through seats to the human body by using biodynamic response parameters represented by apparent mass (APMS) and vibration power absorption (VPA). The b...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2010.02.007

    authors: Shibata N,Maeda S

    更新日期:2010-07-01 00:00:00

  • Comparison of algorithms to quantify muscle fatigue in upper limb muscles based on sEMG signals.

    abstract::This work compared the performance of six different fatigue detection algorithms quantifying muscle fatigue based on electromyographic signals. Surface electromyography (sEMG) was obtained by an experiment from upper arm contractions at three different load levels from twelve volunteers. Fatigue detection algorithms m...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.09.009

    authors: Kahl L,Hofmann UG

    更新日期:2016-11-01 00:00:00

  • Biomechanical analysis of combining head-down tilt traction with vibration for different grades of degeneration of the lumbar spine.

    abstract::In recent years, a combination of traction and vibration therapy is usually used to alleviate low back pain (LBP) in clinical settings. Combining head-down tilt (HDT) traction with vibration was demonstrated to be efficacious for LBP patients in our previous study. However, the biomechanics of the lumbar spine during ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.10.004

    authors: Wang S,Wang L,Wang Y,Du C,Zhang M,Fan Y

    更新日期:2017-01-01 00:00:00

  • Biomechanical analysis using FEA and experiments of a standard plate method versus three cable methods for fixing acetabular fractures with simultaneous THA.

    abstract::Acetabular fractures potentially account for up to half of all pelvic fractures, while pelvic fractures potentially account for over one-tenth of all human bone fractures. This is the first biomechanical study to assess acetabular fracture fixation using plates versus cables in the presence of a total hip arthroplasty...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.06.004

    authors: Aziz MSR,Dessouki O,Samiezadeh S,Bougherara H,Schemitsch EH,Zdero R

    更新日期:2017-08-01 00:00:00

  • Accelerometer based calf muscle pump activity monitoring.

    abstract::Long distance travel is associated with increased risk of deep vein thrombosis (DVT). There is an increased risk of travel related DVT in passengers with a predisposition to thrombosis. Assisting blood circulation in the lower limb will reduce the risk of DVT. Leg exercises are recommended as a DVT preventative measur...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.02.002

    authors: O'Donovan KJ,O'Keeffe DT,Grace PA,Lyons GM

    更新日期:2005-10-01 00:00:00

  • A biomechanical model to determine lumbosacral loads during single stance phase in normal gait.

    abstract::A dynamic biomechanical model to determine loads (joint forces) attained at the lumbosacral joint-centre during the stance phase of normal level walking was developed. The biomechanical model was based on rigid free body-segments; namely, the foot, shank, thigh, pelvis and head, arms and trunk (HAT) segments. In this ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)90374-k

    authors: Khoo BC,Goh JC,Bose K

    更新日期:1995-01-01 00:00:00

  • Effect of longitudinal anatomical mismatch of stenting on the mechanical environment in human carotid artery with atherosclerotic plaques.

    abstract::Longitudinal anatomic mismatch (LAM) of stenting (i.e., a stenotic artery segment is not fully covered by a deployed stent) worsens the mechanical environment in the treated artery, which most likely is the cause for the associated high risks of restenosis, myocardial infarction and stent thrombosis. To probe the poss...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.06.010

    authors: Fan Z,Liu X,Sun A,Zhang N,Fan Z,Fan Y,Deng X

    更新日期:2017-10-01 00:00:00