Determination of backrest inclination based on biodynamic response study for prevention of low back pain.

Abstract:

:Whole-body vibration experiments with subjects under vertical vibration were performed to examine and evaluate effects of backrest inclination on vibration transmitted through seats to the human body by using biodynamic response parameters represented by apparent mass (APMS) and vibration power absorption (VPA). The biodynamic response parameters of twelve male subjects, exposed to vertical random vibration at 0.8 m/s(2) r.m.s., were characterized under three different backrest support conditions, with the upper body supported against backrest inclined at angles of 0 degrees (vertical), 10 degrees, and 30 degrees with respect to the vertical axis. An increased backrest inclination angle resulted in reduction of the total power absorption calculated particularly the frequency range of 1-20 Hz. Normalized APMS magnitudes showed a principal resonance at about 5 Hz for each subject for a backrest supported vertically. A second resonant peak appeared at about 7.5 Hz in addition to the primary resonant peak for a backrest inclined at an angle of 10 degrees and then became much steeper for a backrest inclined at angle of 30 degrees. For a backrest inclined at an angle of 30 degrees, the resonant peak at 5 Hz was less apparent than in other backrest inclination postures. All subjects showed the second resonant peak at about 7.5 Hz in the double-normalized VPA for a backrest inclined at an angle of 30 degrees. According to the evaluation of vibration absorption behavior performed in this study, backrest inclination angle is preferable between 10 degrees and 30 degrees from the viewpoint of prevention of low back pain disorder.

journal_name

Med Eng Phys

authors

Shibata N,Maeda S

doi

10.1016/j.medengphy.2010.02.007

subject

Has Abstract

pub_date

2010-07-01 00:00:00

pages

577-83

issue

6

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(10)00028-7

journal_volume

32

pub_type

临床试验,杂志文章
  • The effect of compressive deformations on the rate of build-up of oxygen in isolated skeletal muscle cells.

    abstract::In this study we integrated between confocal-based cell-specific finite element (FE) modeling and Virtual Cell (VC) transport simulations in order to determine trends of relationship between externally applied compressive deformations and build-up rates of oxygen in myoblast cells, and to further test how mild culture...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.04.008

    authors: Leopold E,Sopher R,Gefen A

    更新日期:2011-11-01 00:00:00

  • Comparison of the bending performance of solid and cannulated spinal pedicle screws using finite element analyses and biomechanical tests.

    abstract::Spinal pedicle screw fixations have been used extensively to treat fracture, tumor, infection, or degeneration of the spine. Cannulated spinal pedicle screws with bone cement augmentation might be a useful method to ameliorate screw loosening. However, cannulated spinal pedicle screws might also increase the risk of s...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.06.008

    authors: Shih KS,Hsu CC,Hou SM,Yu SC,Liaw CK

    更新日期:2015-09-01 00:00:00

  • A computational model-based study on the exchangeability of hepatic venous pressure gradients measured in multiple hepatic veins.

    abstract::Hepatic venous pressure gradient (HVPG) is a hemodynamic index widely used for evaluating the severity of portal hypertension. Theoretically, HVPG can be measured in any of the three major (i.e., right, middle and left) hepatic veins (HVs); however, it remains unclear whether HVPGs measured in different HVs are exchan...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.07.022

    authors: Wang T,Liang F,Li L,Zhang W,Wang G,Wang J,Zhang C,Qi X

    更新日期:2020-10-01 00:00:00

  • New equations to calculate 3D joint centres in the lower extremities.

    abstract::Biomechanical movement analysis in 3D requires estimation of joint centres in the lower extremities and this estimation is based on extrapolation from markers placed on anatomical landmarks. The purpose of the present study was to quantify the accuracy of three established set of equations and provide new improved equ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.07.001

    authors: Sandau M,Heimbürger RV,Villa C,Jensen KE,Moeslund TB,Aanæs H,Alkjær T,Simonsen EB

    更新日期:2015-10-01 00:00:00

  • TETRA mobile radios interfere with electroencephalography recording equipment.

    abstract::We observed an anomaly in the human electroencephalogram (EEG) associated with exposure to terrestrial trunked radio (TETRA) Radiofrequency Fields (RF). Here, we characterize the time and frequency components of the anomaly and demonstrate that it is an artefact caused by TETRA RF interfering with the EEG recording eq...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.04.009

    authors: Fouquet NC,Hawken MB,Elliott P,Burgess AP

    更新日期:2013-11-01 00:00:00

  • On a "Columbus' Egg": Modeling the shape of asymptomatic, dysplastic and impinged hip joints.

    abstract::Understanding morphological features that characterize normal hip joint is critical and necessary for a more comprehensive definition of pathological presentations, such as femoroacetabular impingement and hip dysplasia. Based on anatomical observations that articular surfaces of synovial joints are better represented...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.07.001

    authors: Lopes DS,Pires SM,Mascarenhas VV,Silva MT,Jorge JA

    更新日期:2018-09-01 00:00:00

  • A mathematical model of the impact response of the seated subject.

    abstract::A model of the lumbar spine, pelvis and buttocks is developed, based on linear horizontal and vertical systems along with a rotational subsystem. The model can mimic qualitatively different experimental observations of transmission of vibrations from the seat to L3 in the sitting posture. It is concluded that while th...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)00062-3

    authors: Broman H,Pope M,Hansson T

    更新日期:1996-07-01 00:00:00

  • Comparing passive angle-torque curves recorded simultaneously with a load cell versus an isokinetic dynamometer during dorsiflexion stretch tolerance assessments.

    abstract::The purpose of the present study was to compare the passive angle-torque curves and the passive stiffness (PS, N m °(-)(1)) values recorded simultaneously from a load cell versus an isokinetic dynamometer during dorsiflexion stretch tolerance assessments in vivo. Nine healthy men (mean ± SD age = 21.4 ± 1.6 years) com...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.02.010

    authors: Buckner SL,Jenkins ND,Costa PB,Ryan ED,Herda TJ,Cramer JT

    更新日期:2015-05-01 00:00:00

  • Comparison of virtual and real electric powered wheelchair driving using a position sensing joystick and an isometric joystick.

    abstract::There are limited interface options for electric powered wheelchairs, which results in the inability of some individuals to drive independently. In addition, the development of new interface technologies will necessitate the development of alternative training methods. This study compares a conventional position sensi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00111-x

    authors: Cooper RA,Spaeth DM,Jones DK,Boninger ML,Fitzgerald SG,Guo S

    更新日期:2002-12-01 00:00:00

  • New product development processes within the UK medical device industry.

    abstract::This paper reports on the findings of an extensive survey investigating practising design engineers' perceptions of new product development within the UK medical device industry. The design activity recorded was predominantly the small-scale development of low volume products. Explicit formal procedures were rarely us...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00021-5

    authors: Glen JM,Lord M

    更新日期:1996-12-01 00:00:00

  • Automated analysis of MR image of hip: geometrical evaluation of the Legg-Calve-Perthes disease.

    abstract::This study proposes semi-automatic determination of geometrical features in hip magnetic resonance (MR) images in order to evaluate the Legg-Calvé-Perthes disease (LCPD). Nine anatomical points on a hip image are selected by a clinician; then eight geometrical indexes of the hip joint are calculated: acetabulum head i...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.10.003

    authors: Pouletaut P,Claude I,Winzenrieth R,Ho Ba Tho MC,Sebag G

    更新日期:2005-06-01 00:00:00

  • Computed tomography (CT)-compatible remote center of motion needle steering robot: Fusing CT images and electromagnetic sensor data.

    abstract::Lung cancer is the most common cause of cancer-related death, and early detection can reduce the mortality rate. Patients with lung nodules greater than 10 mm usually undergo a computed tomography (CT)-guided biopsy. However, aligning the needle with the target is difficult and the needle tends to deflect from a strai...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.04.009

    authors: Shahriari N,Heerink W,van Katwijk T,Hekman E,Oudkerk M,Misra S

    更新日期:2017-07-01 00:00:00

  • Current development in non-invasive glucose monitoring.

    abstract::Painless control of blood glycemic levels could improve life quality of diabetes patients, enabling a better regulation of hyper- and hypoglycaemia episodes and thereby avoiding physiological complications. Although research groups have been trying for decades to separate non-invasive glucose information from interfer...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2007.06.003

    authors: Ferrante do Amaral CE,Wolf B

    更新日期:2008-06-01 00:00:00

  • Effects of consecutive slips in nerve signals recorded by implanted cuff electrode.

    abstract::Using an anaesthetized cat's central footpad pressed against an object as the model of a paralyzed human hand, a nerve signal recording system was developed to measure the effect of a group of consecutive slips between the footpad and the object. Electroneurographic (ENG) activity was recorded using a cuff electrode i...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.05.007

    authors: Tong KY,Rong W,Li L,Cao J

    更新日期:2008-05-01 00:00:00

  • An external portable device for adaptive deep brain stimulation (aDBS) clinical research in advanced Parkinson's Disease.

    abstract::Compared to conventional deep brain stimulation (DBS) for patients with Parkinson's Disease (PD), the newer approach of adaptive DBS (aDBS), regulating stimulation on the basis of the patient's clinical state, promises to achieve better clinical outcomes, avoid adverse-effects and save time for tuning parameters. A re...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.02.007

    authors: Arlotti M,Rossi L,Rosa M,Marceglia S,Priori A

    更新日期:2016-05-01 00:00:00

  • Multispectral characterization of tissues encountered during laparoscopic colorectal surgery.

    abstract:AIMS:This study investigated the feasibility of automated differentiation between essential tissue types encountered during laparoscopic colorectal surgery using spectral analysis. METHODS:Wide band (440-1830 nm) spectra were collected using an optical fiber probe and spectrometer from freshly explanted, ex vivo, huma...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.01.004

    authors: Schols RM,Dunias P,Wieringa FP,Stassen LP

    更新日期:2013-07-01 00:00:00

  • Electroactive polymeric sensors in hand prostheses: bending response of an ionic polymer metal composite.

    abstract::In stark contrast to the inspiring functionality of the natural hand, limitations of current upper limb prostheses stemming from marginal feedback control, challenges of mechanical design, and lack of sensory capacity, are well-established. This paper provides a critical review of current sensory systems and the poten...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.09.009

    authors: Biddiss E,Chau T

    更新日期:2006-07-01 00:00:00

  • Robust infrarenal aortic aneurysm lumen centerline detection for rupture status classification.

    abstract::The objective of this work is to develop a robust method for human abdominal aortic aneurysm (AAA) centerline detection that can contribute to the accurate computation of features for the prediction of AAA rupture risk. A semiautomatic algorithm is proposed for detecting the lumen centerline in contrast-enhanced abdom...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.03.005

    authors: Zhang H,Kheyfets VO,Finol EA

    更新日期:2013-09-01 00:00:00

  • Design of tissue engineering scaffolds based on hyperbolic surfaces: structural numerical evaluation.

    abstract::Tissue engineering represents a new field aiming at developing biological substitutes to restore, maintain, or improve tissue functions. In this approach, scaffolds provide a temporary mechanical and vascular support for tissue regeneration while tissue in-growth is being formed. These scaffolds must be biocompatible,...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.05.006

    authors: Almeida HA,Bártolo PJ

    更新日期:2014-08-01 00:00:00

  • Effects of mechanical loading on the profile of human femoral diaphyseal geometry.

    abstract::In vivo bone behaviour predictions with respect to altered loading conditions, implants, and endoprostheses are highly desirable to avoid untoward effects such as implant loosening and breakage. This knowledge does not relate only to the result but also to the mechanisms of bone adaptation and bone growth. Since bone ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(94)90014-0

    authors: Mittlmeier T,Mattheck C,Dietrich F

    更新日期:1994-01-01 00:00:00

  • A multi-sample denaturation temperature tester for collagenous biomaterials.

    abstract::The temperature at which collagen denatures from a triple helix to a random coil structure is a useful measure of the degree of crosslinking. A new multi-sample denaturation temperature tester (DTT) has been constructed for rapid determination of the collagen denaturation temperature of natural tissues and collagenous...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)91882-h

    authors: Lee JM,Pereira CA,Abdulla D,Naimark WA,Crawford I

    更新日期:1995-03-01 00:00:00

  • Objective diagnosis of ADHD using IMUs.

    abstract::This work proposes the use of miniature wireless inertial sensors as an objective tool for the diagnosis of ADHD. The sensors, consisting of both accelerometers and gyroscopes to measure linear and rotational movement, respectively, are used to characterize the motion of subjects in the setting of a psychiatric consul...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.02.023

    authors: O'Mahony N,Florentino-Liano B,Carballo JJ,Baca-García E,Rodríguez AA

    更新日期:2014-07-01 00:00:00

  • Monolithic superelastic rods with variable flexural stiffness for spinal fusion: modeling of the processing-properties relationship.

    abstract::The concept of a monolithic Ti-Ni spinal rod with variable flexural stiffness is proposed to reduce the risks associated with spinal fusion. The variable stiffness is conferred to the rod using the Joule-heating local annealing technique. The annealing temperature and the mechanical properties' distributions resulted ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.07.012

    authors: Facchinello Y,Brailovski V,Petit Y,Mac-Thiong JM

    更新日期:2014-11-01 00:00:00

  • Writing through a robot: a proof of concept for a brain-machine interface.

    abstract::This paper describes a non-invasive human brain-actuated robotic arm experiment, which allows remote writing. In the local environment, the participant decides on an arbitrary word to transmit. A mental speller interface is then used to select the letters. A robot arm placed in the remote environment writes the word o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.06.005

    authors: Pérez-Marcos D,Buitrago JA,Velásquez FD

    更新日期:2011-12-01 00:00:00

  • Finite element stress analysis of a hybrid fracture fixation plate.

    abstract::Metal plates are commonly used in the operative treatment of bone fractures. Rigid metal plates stabilize the fracture site, maintain good contact between bone fragments and allow early weight bearing and patient mobility. However, treatment with rigid metal plates can cause localized bone atrophy due to stress-shield...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)00041-0

    authors: Ferguson SJ,Wyss UP,Pichora DR

    更新日期:1996-04-01 00:00:00

  • On the secondary stability of coated cementless hip replacement: parameters that affected interface strength.

    abstract::Unlike primary stability of coated cementless implants, their secondary stability has been poorly studied. This paper considers some theoretical aspects of the secondary stability of a coated cementless hip implant in a human femur. The bone is separated from the implant by a thin layer of microscopic peaks and trough...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(03)00099-7

    authors: Orlik J,Zhurov A,Middleton J

    更新日期:2003-12-01 00:00:00

  • A predictive study of the mechanical behaviour of coronary stents by computer modelling.

    abstract::Intravascular stents are small tube-like structures expanded into stenotic arteries to restore blood flow perfusion to the downstream tissues. The stent expansion is an important factor to define the effectiveness of the surgical procedure: it depends on the stent geometry and includes large displacements and deformat...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.08.012

    authors: Migliavacca F,Petrini L,Montanari V,Quagliana I,Auricchio F,Dubini G

    更新日期:2005-01-01 00:00:00

  • Bi-directional flow sensor with a wide dynamic range for medical applications.

    abstract::This paper describes a novel three-wire thermal flow sensor for medical applications. The present innovation for low-frequency measurements involves the use of a pulsed-wire anemometer with a comparatively large wire diameter (12.5 microm and larger) together with a novel signal processing approach. A small wire is he...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.06.002

    authors: Al-Salaymeh A,Jovanović J,Durst F

    更新日期:2004-10-01 00:00:00

  • Biomechanical analysis using FEA and experiments of a standard plate method versus three cable methods for fixing acetabular fractures with simultaneous THA.

    abstract::Acetabular fractures potentially account for up to half of all pelvic fractures, while pelvic fractures potentially account for over one-tenth of all human bone fractures. This is the first biomechanical study to assess acetabular fracture fixation using plates versus cables in the presence of a total hip arthroplasty...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.06.004

    authors: Aziz MSR,Dessouki O,Samiezadeh S,Bougherara H,Schemitsch EH,Zdero R

    更新日期:2017-08-01 00:00:00

  • Clinical workflow for personalized foot pressure ulcer prevention.

    abstract::Foot pressure ulcers are a common complication of diabetes because of patient's lack of sensitivity due to neuropathy. Deep pressure ulcers appear internally when pressures applied on the foot create high internal strains nearby bony structures. Monitoring tissue strains in persons with diabetes is therefore important...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.04.017

    authors: Bucki M,Luboz V,Perrier A,Champion E,Diot B,Vuillerme N,Payan Y

    更新日期:2016-09-01 00:00:00