On a "Columbus' Egg": Modeling the shape of asymptomatic, dysplastic and impinged hip joints.

Abstract:

:Understanding morphological features that characterize normal hip joint is critical and necessary for a more comprehensive definition of pathological presentations, such as femoroacetabular impingement and hip dysplasia. Based on anatomical observations that articular surfaces of synovial joints are better represented by ovoidal shapes than by spheres, the aim of this study is to computationally test this morphological classification for the femoral head and acetabular cavity of asymptomatic, dysplastic and impinged hips by comparing spherical, ellipsoidal and ovoidal shapes. An image-based surface fitting framework was used to assess the goodness-of-fit of spherical, ellipsoidal and tapered ellipsoidal (i.e., egg-like) shapes. The framework involved image segmentation with active contour methods, mesh smoothing and decimation, and surface fitting to point clouds performed with genetic algorithms. Image data of the hip region was obtained from computed tomography and magnetic resonance imaging scans. Shape analyses were performed upon image data from 20 asymptomatic, 20 dysplastic and 20 impinged (cam, pincer, and mixed) hips of patients with ages ranging between 18 and 45 years old (28 male and 32 women). Tapered ellipsoids presented the lowest fitting errors (i.e., more oval), followed by ellipsoids and spheres which had the worst goodness-of-fit. Ovoidal geometries are also more representative of cam, pincer, mixed impinged hips when compared to spherical or ellipsoidal shapes. The statistical analysis of the surface fitting errors reveal that ovoidal shapes better represent both articular surfaces of the hip joint, revealing a greater approximation to the overall features of asymptomatic, dysplastic and impinged cases.

journal_name

Med Eng Phys

authors

Lopes DS,Pires SM,Mascarenhas VV,Silva MT,Jorge JA

doi

10.1016/j.medengphy.2018.07.001

subject

Has Abstract

pub_date

2018-09-01 00:00:00

pages

50-55

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(18)30107-3

journal_volume

59

pub_type

杂志文章
  • Low-level laser therapy using the minimally invasive laser needle system on osteoporotic bone in ovariectomized mice.

    abstract::This study tested the effectiveness of low-level laser therapy (LLLT) in preventing and/or treating osteoporotic trabecular bone. Mice were ovariectomized (OVX) to induce osteoporotic bone loss. The tibiae of eight OVX mice were treated for 5 days each week for 2 weeks by LLLT (660 nm, 3 J) using a minimally invasive ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.10.002

    authors: Ko CY,Kang H,Seo DH,Jung B,Schreiber J,Kim HS

    更新日期:2013-07-01 00:00:00

  • Relationship between architectural parameters and sample volume of human cancellous bone in micro-CT scanning.

    abstract::Truly representative architectural parameters of trabeculea can be extremely difficult to achieve based on scanning images because of variable porosity and distribution of trabeculae within the specific overall scanned volume of bone. Accordingly, in present study different selective volume of interests, measured from...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.01.014

    authors: Yan YB,Qi W,Wang J,Liu LF,Teo EC,Tianxia Q,Ba JJ,Lei W

    更新日期:2011-07-01 00:00:00

  • Pilot study of a surgical robot system for zygomatic implant placement.

    abstract::Zygomatic implant technology has been regarded as an alternative treatment to massive grafting surgery in the severe atrophic maxillary. Nowadays, the assistant method with a real-time surgical navigation has been applied to reduce the risks of zygomatic implant placement. However, the accuracy of the complex operatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.07.020

    authors: Cao Z,Qin C,Fan S,Yu D,Wu Y,Qin J,Chen X

    更新日期:2020-01-01 00:00:00

  • The effects of flute shape and thread profile on the insertion torque and primary stability of dental implants.

    abstract::Easy insertion of the implant and stable bone purchase is essential for an ideal dental implantation. At the implant tip, the cutting flutes and conical profile are respectively designed to reduce insertion resistance and facilitate the initial insertion. However, the tapered tip might reduce the self-tapping and bone...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.09.021

    authors: Wu SW,Lee CC,Fu PY,Lin SC

    更新日期:2012-09-01 00:00:00

  • Combining ultrasonic and computed tomography scanning to characterize mechanical properties of cancellous bone in necrotic human femoral heads.

    abstract::Image-based finite element modelling has been commonly used to determine the biomechanical behaviours of human femora, particularly for the diagnosis of femoral head necrosis. One of the fundamental aspects of biomechanical modelling is the relationship between bone density, which is obtained from images, and elastic ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.02.002

    authors: Yue Y,Yang H,Li Y,Zhong H,Tang Q,Wang J,Wang R,He H,Chen W,Chen D

    更新日期:2019-04-01 00:00:00

  • Surface-based modeling of muscles: Functional simulation of the shoulder.

    abstract::Musculoskeletal simulations are an essential tool for studying functional implications of pathologies and of potential surgical outcomes, e.g., for the complex shoulder anatomy. Most shoulder models rely on line-segment approximation of muscles with potential limitations. Comprehensive shoulder models based on continu...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.04.010

    authors: Péan F,Goksel O

    更新日期:2020-08-01 00:00:00

  • Study on gastric interdigestive pressure activity based on phase space reconstruction and FastICA algorithm.

    abstract::To investigate the features of the gastric interdigestive pressure activity under normal physiological conditions, we have developed the wireless radiotelemetry capsule based on a telemetry technique. Twelve healthy volunteers participated in this study. Pressure activity data which are an important index of gastric m...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.04.017

    authors: Huang B,Yan G,Zan P,Li Q

    更新日期:2009-04-01 00:00:00

  • Validation of a C2-C7 cervical spine finite element model using specimen-specific flexibility data.

    abstract::This study presents a specimen-specific C2-C7 cervical spine finite element model that was developed using multiblock meshing techniques. The model was validated using in-house experimental flexibility data obtained from the cadaveric specimen used for mesh development. The C2-C7 specimen was subjected to pure continu...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.03.001

    authors: Kallemeyn N,Gandhi A,Kode S,Shivanna K,Smucker J,Grosland N

    更新日期:2010-06-01 00:00:00

  • Dynamic behavior of tripolar hip endoprostheses under physiological conditions and their effect on stability.

    abstract::Tripolar systems have been implanted to reduce the risk of recurrent dislocation. However, there is little known about the dynamic behavior of tripolar hip endoprostheses under daily life conditions and achieved joint stability. Hence, the objective of this biomechanical study was to examine the in vivo dynamics and d...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.09.007

    authors: Fabry C,Kaehler M,Herrmann S,Woernle C,Bader R

    更新日期:2014-01-01 00:00:00

  • Number and localization of the implants for the fixed prosthetic reconstructions: on the strain in the anterior maxillary region.

    abstract::Resorption following tooth loss and poor bone quality affect the success of implants in the anterior maxilla. Inappropriate planning can cause implant loss and aesthetics problems that are difficult to resolve. There is a limited literature on the optimum number and location of implants in anterior maxilla for fabrica...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.02.004

    authors: Bölükbaşı N,Yeniyol S

    更新日期:2015-04-01 00:00:00

  • Objective diagnosis of ADHD using IMUs.

    abstract::This work proposes the use of miniature wireless inertial sensors as an objective tool for the diagnosis of ADHD. The sensors, consisting of both accelerometers and gyroscopes to measure linear and rotational movement, respectively, are used to characterize the motion of subjects in the setting of a psychiatric consul...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.02.023

    authors: O'Mahony N,Florentino-Liano B,Carballo JJ,Baca-García E,Rodríguez AA

    更新日期:2014-07-01 00:00:00

  • Automatic detection of EEG artefacts arising from head movements using EEG and gyroscope signals.

    abstract::Contamination of EEG signals by artefacts arising from head movements has been a serious obstacle in the deployment of automatic neurological event detection systems in ambulatory EEG. In this paper, we present work on categorizing these head-movement artefacts as one distinct class and on using support vector machine...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.08.017

    authors: O'Regan S,Faul S,Marnane W

    更新日期:2013-07-01 00:00:00

  • Fuzzy clustering of gait patterns of patients after ankle arthrodesis based on kinematic parameters.

    abstract::Kinematic parameters for 10 normal subjects and 10 patients with ankle arthrodesis are grouped using the fuzzy cluster paradigm. The features chosen for clustering are Euler angles of the sagittal plane in the hindfoot, the forefoot and combined hindfoot and forefoot joints. Gait patterns are identified using informat...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00020-0

    authors: Su F,Wu W,Cheng Y,Chou Y

    更新日期:2001-03-01 00:00:00

  • fMRI brain mapping during motion capture and FES induced motor tasks: signal to noise ratio assessment.

    abstract::Functional Electrical Stimulation (FES) is a well known clinical rehabilitation procedure, however the neural mechanisms that underlie this treatment at Central Nervous System (CNS) level are still not completely understood. Functional magnetic resonance imaging (fMRI) is a suitable tool to investigate effects of reha...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.04.005

    authors: Gandolla M,Ferrante S,Casellato C,Ferrigno G,Molteni F,Martegani A,Frattini T,Pedrocchi A

    更新日期:2011-10-01 00:00:00

  • A numerical hemodynamic tool for predictive vascular surgery.

    abstract::We suggest a new approach to peripheral vascular bypass surgery planning based on solving the one-dimensional (1D) governing equations of blood flow in patient-specific models. The aim of the present paper is twofold. First, we present the coupled 1D-0D model based on a discontinuous Galerkin method in a comprehensive...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.04.015

    authors: Marchandise E,Willemet M,Lacroix V

    更新日期:2009-01-01 00:00:00

  • TETRA mobile radios interfere with electroencephalography recording equipment.

    abstract::We observed an anomaly in the human electroencephalogram (EEG) associated with exposure to terrestrial trunked radio (TETRA) Radiofrequency Fields (RF). Here, we characterize the time and frequency components of the anomaly and demonstrate that it is an artefact caused by TETRA RF interfering with the EEG recording eq...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.04.009

    authors: Fouquet NC,Hawken MB,Elliott P,Burgess AP

    更新日期:2013-11-01 00:00:00

  • Liquid ventilation: a mathematical model of gas diffusion in the premature lung.

    abstract::The liquid ventilation (LV) technique was previously demonstrated to be a valuable alternative to ordinary gas ventilation, particularly for newborn patients with severely distressed lungs. This work describes a mathematical model of gas transfer phenomena occurring within the lungs of a preterm newborn baby ventilate...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00041-0

    authors: Costantino ML,Fiore GB

    更新日期:1997-03-01 00:00:00

  • Current development in non-invasive glucose monitoring.

    abstract::Painless control of blood glycemic levels could improve life quality of diabetes patients, enabling a better regulation of hyper- and hypoglycaemia episodes and thereby avoiding physiological complications. Although research groups have been trying for decades to separate non-invasive glucose information from interfer...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2007.06.003

    authors: Ferrante do Amaral CE,Wolf B

    更新日期:2008-06-01 00:00:00

  • Measurement of tooth displacements and mouthpiece forces during brass instrument playing.

    abstract::In order to assess the actual load on front teeth and tooth supportive tissue during brass instrument playing, a measuring system was developed permitting simultaneous recordings of mouthpiece forces and incisor deflections. By the application of strain gauges, the mouthpiece itself was converted into an extra-oral fo...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)00006-9

    authors: Borchers L,Gebert M,Jung T

    更新日期:1995-12-01 00:00:00

  • Non-invasive identification of gastric contractions from surface electrogastrogram using back-propagation neural networks.

    abstract::Gastric contractions play an important role in the digestive process of the stomach. The established method for the measurement of gastric contractions is invasive and involves the insertion through the nose of a manometric probe into the stomach. A non-invasive method is introduced in this paper for the identificatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)95713-k

    authors: Chen JD,Lin Z,Wu Q,McCallum RW

    更新日期:1995-04-01 00:00:00

  • Influence of dual-task on sit-to-stand-to-sit postural control in Parkinson's disease.

    abstract::Postural control deficits are the most disabling aspects of Parkinson's disease (PD), resulting in decreased mobility and functional independence. The aim of this study was to assess the postural control stability, revealed by variables based on the centre of pressure (CoP), in individuals with PD while performing a s...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.08.011

    authors: Fernandes Â,Sousa AS,Couras J,Rocha N,Tavares JM

    更新日期:2015-11-01 00:00:00

  • Motor unit firing rates and synchronisation affect the fractal dimension of simulated surface electromyogram during isometric/isotonic contraction of vastus lateralis muscle.

    abstract::During fatiguing contractions, many adjustments in motor units behaviour occur: decrease in muscle fibre conduction velocity; increase in motor units synchronisation; modulation of motor units firing rate; increase in variability of motor units inter-spike interval. We simulated the influence of all these adjustments ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.09.022

    authors: Mesin L,Dardanello D,Rainoldi A,Boccia G

    更新日期:2016-12-01 00:00:00

  • Identification of lower arm motions using the EMG signals of shoulder muscles.

    abstract::This investigation explored pattern recognition of EMG signals produced by shoulder area muscles to identify the performance of a select number of lower arm motions. The signals were modelled as fourth-order autoregressive processes with the parameters of the models used to classify the different motions. The recorded...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(94)90024-8

    authors: Latwesen A,Patterson PE

    更新日期:1994-03-01 00:00:00

  • LES of non-Newtonian physiological blood flow in a model of arterial stenosis.

    abstract::Large Eddy Simulation (LES) is performed to study the physiological pulsatile transition-to-turbulent non-Newtonian blood flow through a 3D model of arterial stenosis by using five different blood viscosity models: (i) Power-law, (ii) Carreau, (iii) Quemada, (iv) Cross and (v) modified-Casson. The computational domain...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.11.013

    authors: Molla MM,Paul MC

    更新日期:2012-10-01 00:00:00

  • Can a 15m-overground wheelchair sprint be used to assess wheelchair-specific anaerobic work capacity?

    abstract:OBJECTIVE:To evaluate whether outcomes based on stopwatch time and power output (PO) over a 15m-overground wheelchair sprint test can be used to assess wheelchair-specific anaerobic work capacity, by studying their relationship with outcomes on a Wingate-based 30s-wheelchair ergometer sprint (WAnT). METHODS:Able-bodie...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.01.003

    authors: van der Scheer JW,de Groot S,Vegter RJ,Veeger DH,van der Woude LH

    更新日期:2014-04-01 00:00:00

  • Particle image velocimetry study of the celiac trunk hemodynamic induced by continuous-flow left ventricular assist device.

    abstract::Whereas left ventricular assist device (LVAD) is the gold-standard therapy for patients with heart failure, gastrointestinal bleeding is one of the most common complications. LVAD implantation may remarkably impact aortic hemodynamics so that experimental and computational flow analyses can be used to study the diseas...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.06.029

    authors: Scardulla F,Bellavia D,D'Acquisto L,Raffa GM,Pasta S

    更新日期:2017-09-01 00:00:00

  • A method for the extraction of an object from a noisy background.

    abstract::The removal of the background from a noisy image to leave the object of interest, with well defined edges, is a difficult task. Images obtained using radioisotopes have low signal-to-noise ratios due to scattered photons, as well as emitted radiation from the background. Moreover, noise is, also, a consequence of the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)00043-7

    authors: Livieratos GN,Chappell PH

    更新日期:1996-03-01 00:00:00

  • Effects of mechanical loading on the profile of human femoral diaphyseal geometry.

    abstract::In vivo bone behaviour predictions with respect to altered loading conditions, implants, and endoprostheses are highly desirable to avoid untoward effects such as implant loosening and breakage. This knowledge does not relate only to the result but also to the mechanisms of bone adaptation and bone growth. Since bone ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(94)90014-0

    authors: Mittlmeier T,Mattheck C,Dietrich F

    更新日期:1994-01-01 00:00:00

  • A 16-channel SQUID-device for biomagnetic investigations of small objects.

    abstract::Biomagnetic investigations in basic physiological research using animals require measurement devices different from commercial biomagnetometers used in human investigations. Two major problems have to be tackled in the design of such biomagnetometers. First, the spatial sampling needs to be much higher. Second, the di...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00088-0

    authors: Nowak H,Giessler F,Huonker R,Haueisen J,Röther J,Eiselt M

    更新日期:1999-10-01 00:00:00

  • Three-dimensional localisation based on projectional and tomographic image correlation: an application for digital tomosynthesis.

    abstract::Accurate three-dimensional tumor localisation in Radiotherapy, is critical to the treatment outcome, particularly when high dose gradients are present. A number of techniques have been proposed for the localisation of anatomical structures or markers. The present study proposes an approach to a concurrent maximisation...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00015-6

    authors: Messaris G,Kolitsi Z,Badea C,Pallikarakis N

    更新日期:1999-03-01 00:00:00