Electrochemistry of nanoscale DNA surface films on carbon.

Abstract:

:A DNA electrochemical biosensor is an integrated receptor-transducer device. The most important step in the development and manufacture of a sensitive DNA-biosensor for the detection of DNA-drug interactions is the immobilization procedure of the nucleic acid probe on the transducer surface. Magnetic A/C Mode atomic force microscopy (MAC Mode AFM) images in air were used to characterize two different procedures for immobilising nanoscale double-stranded DNA (dsDNA) surface films on carbon electrodes. Thin film dsDNA layers presented holes in the dsDNA film that left parts of the electrode surface uncovered while thicker films showed a uniform and complete coverage of the electrode. These two procedures for preparing dsDNA-biosensors were used to study the influence of reactive oxygen species (ROS) in the mechanism of DNA damage by quercetin, a flavonoid, and adriamycin, an anthracycline anticancer drug. The study of quercetin-DNA interactions in the presence of Cu(II) ions indicated that the formation of a quercetin-Cu(II) complex leads to the formation of ROS necessary to react with DNA, disrupting the helix and causing the formation of 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodGuo). Reduced adriamycin radicals are able to directly cause oxidative damage to DNA, generating 8-oxodGuo and ROS are not directly involved in this genomic mutagenic lesion.

journal_name

Med Eng Phys

authors

Oliveira-Brett AM,Paquim AM,Diculescu VC,Piedade JA

doi

10.1016/j.medengphy.2006.05.009

subject

Has Abstract

pub_date

2006-12-01 00:00:00

pages

963-70

issue

10

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(06)00097-X

journal_volume

28

pub_type

杂志文章
  • An investigation to determine if a single validated density-elasticity relationship can be used for subject specific finite element analyses of human long bones.

    abstract::Subject-specific FE-models of human long bones have to predict mechanical parameters with sufficient accuracy to be applicable in a clinical setting. One of the main aspects in subject-specific FE-models of bones regarding accuracy is the modeling of the material inhomogeneity. The goal of this study was therefore to ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.08.022

    authors: Eberle S,Göttlinger M,Augat P

    更新日期:2013-07-01 00:00:00

  • Design of tissue engineering scaffolds based on hyperbolic surfaces: structural numerical evaluation.

    abstract::Tissue engineering represents a new field aiming at developing biological substitutes to restore, maintain, or improve tissue functions. In this approach, scaffolds provide a temporary mechanical and vascular support for tissue regeneration while tissue in-growth is being formed. These scaffolds must be biocompatible,...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.05.006

    authors: Almeida HA,Bártolo PJ

    更新日期:2014-08-01 00:00:00

  • In vitro model of intravenous fluid administration: analysis of vein resistance to rapid fluid delivery.

    abstract::Rapid fluid administration is the cornerstone of successful trauma resuscitation of patients in a state of shock. Intravenous (IV) fluid delivery is a physical intrusion into a vein which results in a complex interaction between the rigid catheter and the compliant vein. We present an experimental model of IV infusion...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00046-1

    authors: Yaniv S,Halpern P,Aladgem D,Zaretsky U,Elad D

    更新日期:2000-07-01 00:00:00

  • On a "Columbus' Egg": Modeling the shape of asymptomatic, dysplastic and impinged hip joints.

    abstract::Understanding morphological features that characterize normal hip joint is critical and necessary for a more comprehensive definition of pathological presentations, such as femoroacetabular impingement and hip dysplasia. Based on anatomical observations that articular surfaces of synovial joints are better represented...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.07.001

    authors: Lopes DS,Pires SM,Mascarenhas VV,Silva MT,Jorge JA

    更新日期:2018-09-01 00:00:00

  • Model-based physiomarkers of cerebral hemodynamics in patients with mild cognitive impairment.

    abstract::In our previous studies, we have introduced model-based "functional biomarkers" or "physiomarkers" of cerebral hemodynamics that hold promise for improved diagnosis of early-stage Alzheimer's disease (AD). The advocated methodology utilizes subject-specific data-based dynamic nonlinear models of cerebral hemodynamics ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.02.025

    authors: Marmarelis VZ,Shin DC,Orme ME,Zhang R

    更新日期:2014-05-01 00:00:00

  • On the secondary stability of coated cementless hip replacement: parameters that affected interface strength.

    abstract::Unlike primary stability of coated cementless implants, their secondary stability has been poorly studied. This paper considers some theoretical aspects of the secondary stability of a coated cementless hip implant in a human femur. The bone is separated from the implant by a thin layer of microscopic peaks and trough...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(03)00099-7

    authors: Orlik J,Zhurov A,Middleton J

    更新日期:2003-12-01 00:00:00

  • Simulation-based particle swarm optimization and mechanical validation of screw position and number for the fixation stability of a femoral locking compression plate.

    abstract::Locking compression plates (LCPs) have been used to fix femoral shaft fractures. Previous studies have attempted to identify the best LCP screw positions and numbers to achieve the fixation stability. However, the determined screw positions and numbers were mainly based on the surgeons' experiences. The aim of this st...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.09.005

    authors: Lee CH,Shih KS,Hsu CC,Cho T

    更新日期:2014-01-01 00:00:00

  • Finite element prediction of surface strain and fracture strength at the distal radius.

    abstract::To better understand the mechanisms underlying distal radius fracture we have developed finite element models to predict radius bone strain and fracture strength under loading conditions simulating a fall. This study compares experimental surface strains and fracture loads of the distal radius with specimen-specific f...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.07.016

    authors: Edwards WB,Troy KL

    更新日期:2012-04-01 00:00:00

  • Assessment of gait sensitivity norm as a predictor of risk of falling during walking in a neuromusculoskeletal model.

    abstract::Quantifying the risk of falling (falls risk) would be helpful in treating people with gait disorders. The gait sensitivity norm (GSN) is a stability measure that correlates well to risk of falling in passive dynamic walkers but has not been evaluated on humans or human-like walking models. We assessed the correlation ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.03.018

    authors: Thangal SN,Talaty M,Balasubramanian S

    更新日期:2013-10-01 00:00:00

  • Mechanical testing and modelling of the Universal 2 implant.

    abstract::Understanding the load mechanics of orthopaedic implants is important to be able to predict their behaviour in-vivo. Much research, both mechanical and clinical, has been carried out on hip and knee implants, but less has been written about the mechanics of wrist implants. In this paper, the load mechanics of the Univ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.02.008

    authors: Gislason MK,Foster E,Main D,Fusiek G,Niewczas P,Bransby-Zachary M,Nash DH

    更新日期:2016-06-01 00:00:00

  • Dynamic properties of human incudostapedial joint-Experimental measurement and finite element modeling.

    abstract::The incudostapedial joint (ISJ) is a synovial joint connecting the incus and stapes in the middle ear. Mechanical properties of the ISJ directly affect sound transmission from the tympanic membrane to the cochlea. However, how ISJ properties change with frequency has not been investigated. In this paper, we report the...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.02.006

    authors: Jiang S,Gan RZ

    更新日期:2018-04-01 00:00:00

  • Quantification of holographic fringe data: comparison of intact and implanted femurs.

    abstract::The strains developed on the surface of a femur with and without an implanted femoral hip replacement were investigated using holographic interferometry (HI). Interferometric fringe data from the four aspects of the loaded femur were quantified and the resulting curvature calculated. Curvature was related to the strai...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00003-4

    authors: Katz DM,Blatcher S,Shelton JC

    更新日期:1998-03-01 00:00:00

  • Development and validation of an improved mechanical thorax for simulating cardiopulmonary resuscitation with adjustable chest stiffness and simulated blood flow.

    abstract::Investigations of compressive frequency, duty cycle, or waveform during CPR are typically rooted in animal research or computer simulations. Our goal was to generate a mechanical model incorporating alternate stiffness settings and an integrated blood flow system, enabling defined, reproducible comparisons of CPR effi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.02.005

    authors: Eichhorn S,Spindler J,Polski M,Mendoza A,Schreiber U,Heller M,Deutsch MA,Braun C,Lange R,Krane M

    更新日期:2017-05-01 00:00:00

  • In vivo measurements of the elastic mechanical properties of human skin by indentation tests.

    abstract::Knowledge about the human skin mechanical properties is essential in several domains, particularly for dermatology, cosmetic or to detect some cutaneous pathology. This study proposes a new method to determine the human skin mechanical properties in vivo using the indentation test. Usually, the skin mechanical paramet...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.06.011

    authors: Pailler-Mattei C,Bec S,Zahouani H

    更新日期:2008-06-01 00:00:00

  • A portable monitoring system for measuring weight-bearing during tibial fracture healing.

    abstract::An ambulatory monitoring system has been developed to measure the weight-bearing achieved by a patient on their fractured leg. The system is lightweight, portable, and can monitor weight-bearing continuously over an extended period of time. In addition to mean weight-bearing, the system can also determine temporal par...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00061-7

    authors: Aranzulla PJ,Muckle DS,Cunningham JL

    更新日期:1998-10-01 00:00:00

  • Multi-adaptive filtering technique for surface somatosensory evoked potentials processing.

    abstract::Somatosensory evoked potential (SEP) testing has been widely applied to diagnosis of various neurological disorders. However, SEP recorded using surface electrodes is buried in noises, which makes the signal-to-noise ratio (SNR) very poor. Conventional averaging method usually requires up to thousands of raw SEP input...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.09.007

    authors: Lam BS,Hu Y,Lu WW,Luk KD,Chang CQ,Qiu W,Chan FH

    更新日期:2005-04-01 00:00:00

  • A practical technique for measuring human biofluid conductivity using high gain-frequency characteristics.

    abstract::Currently, the study of ion composition and performance in human biofluids plays an important role in biomedical engineering research and technology. This field may become universal for human diagnostics; it allows early detection of different diseases in humans by measuring changes in ion behaviour in human biofluids...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.04.007

    authors: Al-Nabulsi JI,Aloquili O,Ausheva V,Yuldashev ZM

    更新日期:2011-11-01 00:00:00

  • A multi-sample denaturation temperature tester for collagenous biomaterials.

    abstract::The temperature at which collagen denatures from a triple helix to a random coil structure is a useful measure of the degree of crosslinking. A new multi-sample denaturation temperature tester (DTT) has been constructed for rapid determination of the collagen denaturation temperature of natural tissues and collagenous...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)91882-h

    authors: Lee JM,Pereira CA,Abdulla D,Naimark WA,Crawford I

    更新日期:1995-03-01 00:00:00

  • Assessment of the initial viscoelastic properties of a critical segmental long bone defect reconstructed with impaction bone grafting and intramedullary nailing.

    abstract:INTRODUCTION:This study compared the initial viscoelastic properties of a segmental tibial defect stabilized with intramedullary nailing and impaction bone grafting to that of a transverse fracture stabilized with intramedullary nailing. MATERIALS AND METHODS:Seven sheep tibiae were tested in compression (1000N), bend...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.09.003

    authors: Costi JJ,Stanley RM,Ding B,Solomon LB

    更新日期:2014-01-01 00:00:00

  • Sensitivity analysis of the position of the intervertebral centres of reaction in upright standing--a musculoskeletal model investigation of the lumbar spine.

    abstract::The loads between adjacent vertebrae can be generalised as a single spatial force acting at the intervertebral centre of reaction. The exact position in vivo is unknown. However, in rigid body musculoskeletal models that simulate upright standing, the position is generally assumed to be located at the discs' centres o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.12.003

    authors: Zander T,Dreischarf M,Schmidt H

    更新日期:2016-03-01 00:00:00

  • Can a 15m-overground wheelchair sprint be used to assess wheelchair-specific anaerobic work capacity?

    abstract:OBJECTIVE:To evaluate whether outcomes based on stopwatch time and power output (PO) over a 15m-overground wheelchair sprint test can be used to assess wheelchair-specific anaerobic work capacity, by studying their relationship with outcomes on a Wingate-based 30s-wheelchair ergometer sprint (WAnT). METHODS:Able-bodie...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.01.003

    authors: van der Scheer JW,de Groot S,Vegter RJ,Veeger DH,van der Woude LH

    更新日期:2014-04-01 00:00:00

  • Pulse transit time in paediatric respiratory sleep studies.

    abstract::Pulse transit time (PTT) has emerged over the recent decades as a simple and non-invasive measure to quantify inspiratory effort changes in adults with sleep disordered breathing (SDB). Hence, this shows promise to be an effective screening tool for the paediatrics. However, little is known about its utility and suita...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2006.01.006

    authors: Foo JY

    更新日期:2007-01-01 00:00:00

  • Clinical relevance of augmented statistical shape model of the scapula in the glenoid region.

    abstract:OBJECTIVE:To illustrate (a) whether a statistical shape model (SSM) augmented with anatomical landmark set(s) performs better fitting and provides improved clinical relevance over non-augmented SSM and (b) which anatomical landmark set provides the best augmentation strategy for predicting the glenoid region of the sca...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.11.007

    authors: Salhi A,Burdin V,Brochard S,Mutsvangwa TE,Borotikar B

    更新日期:2020-02-01 00:00:00

  • Including aortic valve morphology in computational fluid dynamics simulations: initial findings and application to aortic coarctation.

    abstract::Computational fluid dynamics (CFD) simulations quantifying thoracic aortic flow patterns have not included disturbances from the aortic valve (AoV). 80% of patients with aortic coarctation (CoA) have a bicuspid aortic valve (BAV) which may cause adverse flow patterns contributing to morbidity. Our objectives were to d...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.07.015

    authors: Wendell DC,Samyn MM,Cava JR,Ellwein LM,Krolikowski MM,Gandy KL,Pelech AN,Shadden SC,LaDisa JF Jr

    更新日期:2013-06-01 00:00:00

  • Identification of patients prone to hypotension during hemodialysis based on the analysis of cardiovascular signals.

    abstract::Intradialytic hypotension (IDH) is a major complication during hemodialysis treatment, and therefore it is highly desirable to identify, at an early stage during treatment, whether the patient is prone to IDH. Heart rate variability (HRV), blood pressure variability (BPV) and baroreflex sensitivity (BRS) were analyzed...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.10.003

    authors: Hernando D,Sörnmo L,Sandberg F,Laguna P,Llamedo M,Bailón R

    更新日期:2015-12-01 00:00:00

  • BION microstimulators: a case study in the engineering of an electronic implantable medical device.

    abstract::The BION (Bionic Neuron) is a single channel implantable neurostimulator of unique design that can be delivered by injection. The development of the BION injectable neurostimulators exemplifies a challenging, but well posed medical design problem addressed with a successful strategy for prioritizing and resolving the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2010.08.010

    authors: Kane MJ,Breen PP,Quondamatteo F,ÓLaighin G

    更新日期:2011-01-01 00:00:00

  • Mechanical behaviour of DNA molecules--elasticity and migration.

    abstract::A novel multi-scale simulation method developed to describe mesoscale phenomena occurring in biofluidic devices is presented. The approach combines the macro-scale modelling of the carrier fluid and the micro-scale description of the transported macromolecules or compounds. Application of the approach is demonstrated ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.08.003

    authors: Benke M,Shapiro E,Drikakis D

    更新日期:2011-09-01 00:00:00

  • Bi-directional flow sensor with a wide dynamic range for medical applications.

    abstract::This paper describes a novel three-wire thermal flow sensor for medical applications. The present innovation for low-frequency measurements involves the use of a pulsed-wire anemometer with a comparatively large wire diameter (12.5 microm and larger) together with a novel signal processing approach. A small wire is he...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.06.002

    authors: Al-Salaymeh A,Jovanović J,Durst F

    更新日期:2004-10-01 00:00:00

  • Femur finite element model instantiation from partial anatomies using statistical shape and appearance models.

    abstract::Accurate models of bone shapes are essential for orthopaedic reconstructions. The commonly used methods of using the contralateral side requires an intact bone and anatomical symmetry. Recent studies have shown that statistical shape and appearance models (SSAMs) as an alternative can predict accurate geometric models...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.03.007

    authors: Nolte D,Bull AMJ

    更新日期:2019-05-01 00:00:00

  • Pulsatile impeller heart: a viable alternative to a problematic diaphragm heart.

    abstract::The impeller blood pump with its simplicity has many advantages compared with the diaphragm pump, but the nonpulsatile property has limited its applications. To make the impeller pump pulsatile, many investigations have been made in vain because of resulting haemolysis. The author has succeeded in producing a pulsatil...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)00010-0

    authors: Qian KX

    更新日期:1996-01-01 00:00:00