Compressive and tensile properties of articular cartilage in axial loading are modulated differently by osmotic environment.

Abstract:

:Aims of the present study were to test the hypotheses that (1) the compressive properties of articular cartilage are affected more by changes in the medium ionic concentration than the tensile properties, (2) collagen network controls the compression-tension nonlinearity of articular cartilage, and (3) proteoglycan (PG) and collagen contents are primary determinants of the compressive and tensile properties of cartilage, respectively. These hypotheses were experimentally tested by axial compressive and tensile tests (perpendicular to the cartilage surface) of bovine articular cartilage samples immersed in 0.005 M (n=6), 0.15M (n=12) and 1.0M (n=6) saline solutions. Compressive and tensile behaviour was analyzed by a nonlinear fibril-reinforced poroelastic model. Tissue PG and collagen contents were measured using Fourier transform infrared imaging spectroscopy (FT-IRIS). The compressive modulus of cartilage varied significantly (n=6, p<0.05) as the medium concentration changed. The tensile modulus changed significantly only as the medium concentration was reduced from 0.15 to 0.005 M (n=6, p<0.05). The fibril-reinforced poroelastic model with stiff, nonlinear collagen fibrils predicted the experimentally measured compression-tension nonlinearity of cartilage. Tissue PG and collagen contents accounted for the compressive and tensile properties of cartilage.

journal_name

Med Eng Phys

authors

Korhonen RK,Jurvelin JS

doi

10.1016/j.medengphy.2009.11.004

subject

Has Abstract

pub_date

2010-03-01 00:00:00

pages

155-60

issue

2

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(09)00236-7

journal_volume

32

pub_type

杂志文章
  • Measurement of tooth displacements and mouthpiece forces during brass instrument playing.

    abstract::In order to assess the actual load on front teeth and tooth supportive tissue during brass instrument playing, a measuring system was developed permitting simultaneous recordings of mouthpiece forces and incisor deflections. By the application of strain gauges, the mouthpiece itself was converted into an extra-oral fo...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)00006-9

    authors: Borchers L,Gebert M,Jung T

    更新日期:1995-12-01 00:00:00

  • Analysis of the effects of surface stiffness on the contact interaction between a finger and a cylindrical handle using a three-dimensional hybrid model.

    abstract::Contact interactions between the hand and handle, such as the contact surface softness and contact surface curvature, will affect both physical effort and musculoskeletal fatigue, thereby the comfort and safety of power tool operations. Previous models of hand gripping can be categorized into two groups: multi-body dy...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.03.007

    authors: Wu JZ,Dong RG,Warren CM,Welcome DE,McDowell TW

    更新日期:2014-07-01 00:00:00

  • Development and evaluation of an automated stainer for acid-fast bacilli.

    abstract::The current strategy for the control of tuberculosis (TB) relies on early diagnosis, and smear microscopy is an essential component of the laboratory diagnosis of TB in most countries with a high prevalence of the disease. However, even simple smear microscopy examination is far from satisfactory because staining resu...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00213-8

    authors: Kim SC,Kang SI,Kim DW,Kim SC,Cho SN,Hwang JH,Kim Y,Song SD,Kim YH

    更新日期:2003-05-01 00:00:00

  • Morphology based anisotropic finite element models of the proximal femur validated with experimental data.

    abstract::Finite element analysis (FEA) of bones scanned with Quantitative Computed Tomography (QCT) can improve early detection of osteoporosis. The accuracy of these models partially depends on the assigned material properties, but anisotropy of the trabecular bone cannot be fully captured due to insufficient resolution of QC...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.08.010

    authors: Enns-Bray WS,Ariza O,Gilchrist S,Widmer Soyka RP,Vogt PJ,Palsson H,Boyd SK,Guy P,Cripton PA,Ferguson SJ,Helgason B

    更新日期:2016-11-01 00:00:00

  • Mechanical performance of Anatomic-Functional-Geometry dental treatments: A computational study.

    abstract::In this paper the biomechanical response of a novel dental preparation technique, referred to as the Anatomic-Functional-Geometry treatment (AFG), is investigated through a 3D nonlinear finite-element modelling approach. A comparative investigation against a standard technique employed in dental clinical practice is c...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.10.016

    authors: Gaziano P,Lorenzi C,Bianchi D,Monaldo E,Dolci A,Vairo G

    更新日期:2020-12-01 00:00:00

  • Numerical analysis and experimental observation of guidewire motion in a blood vessel model.

    abstract::We have developed a computer-based system to simulate a guidewire in blood vessels for surgical planning, intra-operative assistance, and to facilitate the design of new guidewires. In this study, we compared simulation results with experimental results for validation of the simulation system. First, we inserted a com...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.09.012

    authors: Takashima K,Tsuzuki S,Ooike A,Yoshinaka K,Yu K,Ohta M,Mori K

    更新日期:2014-12-01 00:00:00

  • An external portable device for adaptive deep brain stimulation (aDBS) clinical research in advanced Parkinson's Disease.

    abstract::Compared to conventional deep brain stimulation (DBS) for patients with Parkinson's Disease (PD), the newer approach of adaptive DBS (aDBS), regulating stimulation on the basis of the patient's clinical state, promises to achieve better clinical outcomes, avoid adverse-effects and save time for tuning parameters. A re...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.02.007

    authors: Arlotti M,Rossi L,Rosa M,Marceglia S,Priori A

    更新日期:2016-05-01 00:00:00

  • Linear and nonlinear analyses of multi-channel mechanomyographic recordings reveal heterogeneous activation of wrist extensors in presence of delayed onset muscle soreness.

    abstract::In this study, we applied multi-channel mechanomyographic (MMG) recordings in combination with linear and nonlinear analyses to investigate muscular and musculotendinous effects of high intensity eccentric exercise. Twelve accelerometers arranged in a 3 × 4 matrix over the dominant elbow muscles were used to detect MM...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.09.003

    authors: Madeleine P,Hansen EA,Samani A

    更新日期:2014-12-01 00:00:00

  • The formation and function of the sclerosis rim in the femoral head: A biomechanical point of view.

    abstract::Sclerosis rim surrounding the necrotic area is commonly found in necrotic femoral head, but the biomechanical function of sclerosis rim has received relatively little attention. Little is known about the formation and natural history of sclerosis rim. In the present work, we assume that the necrotic change may trigger...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.09.005

    authors: Chen Z,Xu Y,Qi Z,Zho J

    更新日期:2015-12-01 00:00:00

  • Electrocardiogram beat detection enhancement using independent component analysis.

    abstract::Beat detection is a basic and fundamental step in electrocardiogram (ECG) processing. In many ECG applications strong artifacts from biological or technical sources could appear and cause distortion of ECG signals. Beat detection algorithm desired property is to avoid these distortions and detect beats in any situatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.07.017

    authors: Kuzilek J,Lhotska L

    更新日期:2013-06-01 00:00:00

  • Shape-memory-alloy-based smart knee spacer for total knee arthroplasty: 3D CAD modelling and a computational study.

    abstract::This study introduced a shape memory alloy (SMA)-based smart knee spacer for total knee arthroplasty (TKA). Subsequently, a 3D CAD model of a smart tibial component of TKA was designed in Solidworks software, and verified using a finite element analysis in ANSYS Workbench. The two major properties of the SMA (NiTi), t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.03.001

    authors: Gautam A,Callejas MA,Acharyya A,Acharyya SG

    更新日期:2018-05-01 00:00:00

  • A new method of assessing the mechanical properties of patient support systems (PSS) using a phantom. A preliminary communication.

    abstract::Pressure ulcers are a major problem worldwide believed to affect over 5% of all hospital in-patients, and countless others in the community at large. Many types of Patient Support Systems (PSS) are sold as pressure ulcer prevention equipment, but no consensus exists as to their mechanical efficacy. The use of human vo...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00053-3

    authors: Bain DS,Scales JT,Nicholson GP

    更新日期:1999-06-01 00:00:00

  • Measurement of thermal conductivity of bovine cortical bone.

    abstract::The thermal conductivity of cortical bone was characterized experimentally. Specimens were taken from the mid-diaphysis of bovine femora, and the rate of heat transfer was measured in three orthogonal directions. The conductivity was found to be 0.58+/-0.018 W/mK in the longitudinal direction, 0.53+/-0.030 W/mK in the...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00003-0

    authors: Davidson SR,James DF

    更新日期:2000-12-01 00:00:00

  • Is respiratory sinus arrhythmia present in atrial fibrillation? A study using two quantitative methods.

    abstract::Two quantitative techniques have been evaluated to examine whether respiratory sinus arrhythmia can be detected in atrial fibrillation. Cyclical changes in heart rate during deep breathing indicating respiratory sinus arrhythmia were seen in 11/15 control patients, but only 1/44 patients with atrial fibrillation. Powe...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/1350-4533(94)90061-2

    authors: Chandler ST,Trewby PN

    更新日期:1994-07-01 00:00:00

  • Effects of cartilage rings on airflow and particle deposition in the trachea and main bronchi.

    abstract::In most computational fluid dynamic (CFD) analysis of the human lung, it has been assumed that the trachea and branches of the lung have smooth walls. In order to determine if this is a valid assumption, the effects of cartilage rings on airflow and particle deposition in the lungs was determined through conducting si...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.06.010

    authors: Russo J,Robinson R,Oldham MJ

    更新日期:2008-06-01 00:00:00

  • An automated ECG-artifact removal method for trunk muscle surface EMG recordings.

    abstract::This study aimed at developing a method for automated electrocardiography (ECG) artifact detection and removal from trunk electromyography signals. Independent Component Analysis (ICA) method was applied to the simulated data set of ECG-corrupted surface electromyography (SEMG) signals. Independent Components (ICs) co...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.05.007

    authors: Mak JN,Hu Y,Luk KD

    更新日期:2010-10-01 00:00:00

  • Evaluation of the magnitude of hip joint deformation in subjects with avascular necrosis of the hip joint during walking with and without Scottish Rite orthosis.

    abstract::The femoral head in subjects with leg calve perthes disease (LCPD) is generally considerably deformed. It is debatable whether this deformation is due to an increase in applied loads, a decrease in bone mineral density or a change in containment of articular surfaces. The aim of this study was to determine the influen...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.10.015

    authors: Karimi MT,Mohammadi A,Ebrahimi MH,McGarry A

    更新日期:2017-02-01 00:00:00

  • A novel ultrasonic aerosol generator.

    abstract::An ultrasonic aerosol generator constructed from a domestic humidifier is described which has been used to produce liquid aerosols for physiological investigations. The instrument was constructed from a Pifco domestic humidifier modified to include an energy guide to direct the oscillations of the transducer through t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)97320-o

    authors: Davies A,Hudson N,Pirie L

    更新日期:1995-07-01 00:00:00

  • Cytoskeleton and plasma-membrane damage resulting from exposure to sustained deformations: A review of the mechanobiology of chronic wounds.

    abstract::The purpose of this review paper is to summarize the current knowledge on cell-scale mechanically-inflicted deformation-damage, which is at the frontier of cell mechanobiology and biomechanics science, specifically in the context of chronic wounds. The dynamics of the mechanostructure of cells and particularly, the da...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2016.05.014

    authors: Gefen A,Weihs D

    更新日期:2016-09-01 00:00:00

  • Suspension microarrays for the identification of the response patterns in hyperinflammatory diseases.

    abstract::Miniaturized and parallelized sandwich immunoassays allow the simultaneous analysis of a variety of parameters in a single experiment. Bead-based protein array systems or suspension microarrays are well-established multiplex sandwich immunoassay formats. To study inflammatory diseases, protein arrays can be used to an...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.01.003

    authors: Hsu HY,Wittemann S,Schneider EM,Weiss M,Joos TO

    更新日期:2008-10-01 00:00:00

  • A numerical investigation into the influence of the properties of cobalt chrome cellular structures on the load transfer to the periprosthetic femur following total hip arthroplasty.

    abstract::Stress shielding of the periprosthetic femur following total hip arthroplasty is a problem that can promote the premature loosening of femoral stems. In order to reduce the need for revision surgery it is thought that more flexible implant designs need to be considered. In this work, the mechanical properties of laser...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.02.008

    authors: Hazlehurst KB,Wang CJ,Stanford M

    更新日期:2014-04-01 00:00:00

  • Porcine carotid arterial material property alterations with induced atheroma: an in vivo study.

    abstract:OBJECTIVE:A novel methodology has been developed to evaluate regional alterations in arterial wall material properties with induced atheroma in an animal model. METHODS:Atheromatous lesions (fatty, fibro-fatty, and fibrous) were induced in the carotid arteries of a Yucatan miniswine model by endothelial cell denudatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.09.014

    authors: Nagaraj A,Kim H,Hamilton AJ,Mun JH,Smulevitz B,Kane BJ,Yan LL,Roth SI,McPherson DD,Chandran KB

    更新日期:2005-03-01 00:00:00

  • Computational analysis on the mechanical interaction between a thrombus and red blood cells: possible causes of membrane damage of red blood cells at microvessels.

    abstract::Previous studies investigating thrombus formation have not focused on the physical interaction between red blood cells (RBCs) and thrombus, although they have been speculated that some pathological conditions such as microangiopathic hemolytic anemia (MAHA) stem from interactions between RBCs and thrombi. In this stud...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.01.003

    authors: Kamada H,Imai Y,Nakamura M,Ishikawa T,Yamaguchi T

    更新日期:2012-12-01 00:00:00

  • Numerical simulation of the flow of aqueous humor in the Schlemm's canal.

    abstract::Schlemm's canal (SC) is a ring structure responsible for maintaining fluid homeostasis in the anterior chamber of the eye by draining aqueous humor (AH) from the trabecular meshwork (TM) into the collecting channel (CC). Obstruction of the AH flow in this conventional pathway leads to an elevation of intraocular press...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.12.005

    authors: Guo JM,Chen ZQ,Chen W,Yan XQ,Zhang H,Wang JM

    更新日期:2021-02-01 00:00:00

  • A biased competition based neurodynamical model of visual neglect.

    abstract::On the computational basis of a neurodynamical cortical model, we investigate a specific top-down visual cognitive impairment in brain-damaged patients known as visual spatial neglect. The computational cortical model accounts the neurodynamics underlying selective visual attention, is based on the "biased competition...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2004.06.011

    authors: Deco G,Zihl J

    更新日期:2004-11-01 00:00:00

  • Mechanical behaviour of DNA molecules--elasticity and migration.

    abstract::A novel multi-scale simulation method developed to describe mesoscale phenomena occurring in biofluidic devices is presented. The approach combines the macro-scale modelling of the carrier fluid and the micro-scale description of the transported macromolecules or compounds. Application of the approach is demonstrated ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.08.003

    authors: Benke M,Shapiro E,Drikakis D

    更新日期:2011-09-01 00:00:00

  • Reconstruction of proximal humeral fractures with a reduced number of screws and a reinforced bone substitute.

    abstract::Multi-fragmented fractures of the proximal humerus are difficult to treat, especially in the case of osteoporotic bone. Intra-operative risks include cartilage damage when inserting multiple screws. A common post-operative complication is distal-varus collapse of the head. The aim of this study was to investigate if a...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.06.002

    authors: Cristofolini L,Morellato K,Cavallo M,Guerra E

    更新日期:2020-08-01 00:00:00

  • Physiological simulation of blood flow in the aorta: comparison of hemodynamic indices as predicted by 3-D FSI, 3-D rigid wall and 1-D models.

    abstract::Interest in patient-specific blood-flow circulation modeling has increased substantially in recent years. The availability of clinical data for geometric and elastic properties together with efficient numerical methods has now made model rendering feasible. This work uses 3-D fluid-structure interaction (FSI) to provi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.08.009

    authors: Reymond P,Crosetto P,Deparis S,Quarteroni A,Stergiopulos N

    更新日期:2013-06-01 00:00:00

  • Characterization of crackles from patients with fibrosis, heart failure and pneumonia.

    abstract::The spectral analysis of crackles sounds has been carried out based on the assumption that they are stationary signals, and the majority of the work on the crackles was accomplished before the publication of the Computerized Respiratory Sound Analysis (CORSA) guidelines. This works characterizes crackles acquired from...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.06.009

    authors: Ponte DF,Moraes R,Hizume DC,Alencar AM

    更新日期:2013-04-01 00:00:00

  • Wear of polyethylene cups in total hip arthroplasty: a parametric mathematical model.

    abstract::This paper presents a parametric mathematical model of the head-cup wear coupling in total hip arthroplasty (THA). The model evaluates the dependence of acetabular volumetric wear upon the characteristic parameters of patient and hip prosthesis. Archard's law is assumed to calculate the wear coupling behaviour. The we...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00004-6

    authors: Pietrabissa R,Raimondi M,Di Martino E

    更新日期:1998-04-01 00:00:00