Validation of a finite element model of a unilateral external fixator in a rabbit tibia defect model.

Abstract:

:In case of large segmental defects in load-bearing bones, an external fixator is used to provide mechanical stability to the defect site. The overall stiffness of the bone-fixator system is determined not only by the fixator design but also by the way the fixator is mounted to the bone. This stiffness is an important factor as it will influence the biomechanical environment to which tissue engineering scaffolds and regenerating tissues are exposed. A finite element (FE) model can be used to predict the system stiffness. The goal of this study is to develop and validate a 3D anatomical FE model of a bone-fixator system which includes a previously developed unilateral external fixator for a large segmental defect model in the rabbit tibia. It was hypothesized that the contact interfaces between bone and fixator screws play a major role for the prediction of the stiffness. In vitro mechanical testing was performed in order to measure the axial stiffness of cortical bone from mid-shaft rabbit tibiae and of the tibia-fixator system, as well as the bending stiffness of individual fixator screws, inserted in bone. μCT-based case-specific FE models of cortical bone and SCREW-BONE specimens were created to simulate the corresponding mechanical test set-ups. The Young's modulus of rabbit cortical bone as well as appropriate screw-bone contact settings were derived from those FE models. We then used the derived settings in an FE model of the tibia-fixator system. The difference between the FE predicted and measured axial stiffness of the tibia-fixator system was reduced from 117.93% to 7.85% by applying appropriate screw-bone contact settings. In conclusion, this study shows the importance of screw-bone contact settings for an accurate fixator stiffness prediction. The validated FE model can further be used as a tool for virtual mechanical testing in the design phase of new tissue engineering scaffolds and/or novel patient-specific external fixation devices.

journal_name

Med Eng Phys

authors

Karunratanakul K,Kerckhofs G,Lammens J,Vanlauwe J,Schrooten J,Van Oosterwyck H

doi

10.1016/j.medengphy.2012.10.006

subject

Has Abstract

pub_date

2013-07-01 00:00:00

pages

1037-43

issue

7

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(12)00283-4

journal_volume

35

pub_type

杂志文章
  • An automated ECG-artifact removal method for trunk muscle surface EMG recordings.

    abstract::This study aimed at developing a method for automated electrocardiography (ECG) artifact detection and removal from trunk electromyography signals. Independent Component Analysis (ICA) method was applied to the simulated data set of ECG-corrupted surface electromyography (SEMG) signals. Independent Components (ICs) co...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.05.007

    authors: Mak JN,Hu Y,Luk KD

    更新日期:2010-10-01 00:00:00

  • Effects of consecutive slips in nerve signals recorded by implanted cuff electrode.

    abstract::Using an anaesthetized cat's central footpad pressed against an object as the model of a paralyzed human hand, a nerve signal recording system was developed to measure the effect of a group of consecutive slips between the footpad and the object. Electroneurographic (ENG) activity was recorded using a cuff electrode i...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.05.007

    authors: Tong KY,Rong W,Li L,Cao J

    更新日期:2008-05-01 00:00:00

  • Implementation of a PC-based integrated control system for children.

    abstract::Children with severe physical disabilities often require a range of technological devices to aid them with the fundamental tasks carried out in everyday life. These tasks areas may include mobility, communication, environment control and computer access for education. The most efficient, and often the most cost-effect...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(94)90043-4

    authors: Hawley MS,Cudd PA,Cherry AD

    更新日期:1994-05-01 00:00:00

  • A predictive study of the mechanical behaviour of coronary stents by computer modelling.

    abstract::Intravascular stents are small tube-like structures expanded into stenotic arteries to restore blood flow perfusion to the downstream tissues. The stent expansion is an important factor to define the effectiveness of the surgical procedure: it depends on the stent geometry and includes large displacements and deformat...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.08.012

    authors: Migliavacca F,Petrini L,Montanari V,Quagliana I,Auricchio F,Dubini G

    更新日期:2005-01-01 00:00:00

  • Computed tomography (CT)-compatible remote center of motion needle steering robot: Fusing CT images and electromagnetic sensor data.

    abstract::Lung cancer is the most common cause of cancer-related death, and early detection can reduce the mortality rate. Patients with lung nodules greater than 10 mm usually undergo a computed tomography (CT)-guided biopsy. However, aligning the needle with the target is difficult and the needle tends to deflect from a strai...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.04.009

    authors: Shahriari N,Heerink W,van Katwijk T,Hekman E,Oudkerk M,Misra S

    更新日期:2017-07-01 00:00:00

  • Enabling variable-stiffness hand rehabilitation orthoses with dielectric elastomer transducers.

    abstract::Patients affected by motor disorders of the hand and having residual voluntary movements of fingers or wrist can benefit from self-rehabilitation exercises performed with so-called dynamic hand splints. These systems consist of orthoses equipped with elastic cords or springs, which either provide a sustained stretch o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.10.015

    authors: Carpi F,Frediani G,Gerboni C,Gemignani J,De Rossi D

    更新日期:2014-02-01 00:00:00

  • Automated robot-assisted assessment for wrist active ranges of motion.

    abstract::The measurement of wrist active range of motion (ROM) is essential for determining the progress of hand functional recovery, which can provide insight into quantitative improvements and enable effective monitoring during hand rehabilitation. Compared with manual methods, which depend on the experience of the therapist...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.07.003

    authors: Zhang M,McDaid A,Zhang S,Zhang Y,Xie SQ

    更新日期:2019-09-01 00:00:00

  • Evaluation of the magnitude of hip joint deformation in subjects with avascular necrosis of the hip joint during walking with and without Scottish Rite orthosis.

    abstract::The femoral head in subjects with leg calve perthes disease (LCPD) is generally considerably deformed. It is debatable whether this deformation is due to an increase in applied loads, a decrease in bone mineral density or a change in containment of articular surfaces. The aim of this study was to determine the influen...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.10.015

    authors: Karimi MT,Mohammadi A,Ebrahimi MH,McGarry A

    更新日期:2017-02-01 00:00:00

  • Investigation to predict patellar tendon reflex using motion analysis technique.

    abstract::The investigation of patellar tendon reflex involves development of a reflex hammer holder, kinematic data collection and analysis of patellar reflex responses using motion analysis techniques. The main aim of this research is to explore alternative means of assessing reflexes as a part of routine clinical diagnosis. ...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2010.11.002

    authors: Tham LK,Osman NA,Lim KS,Pingguan-Murphy B,Abas WA,Zain NM

    更新日期:2011-05-01 00:00:00

  • A practical technique for measuring human biofluid conductivity using high gain-frequency characteristics.

    abstract::Currently, the study of ion composition and performance in human biofluids plays an important role in biomedical engineering research and technology. This field may become universal for human diagnostics; it allows early detection of different diseases in humans by measuring changes in ion behaviour in human biofluids...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.04.007

    authors: Al-Nabulsi JI,Aloquili O,Ausheva V,Yuldashev ZM

    更新日期:2011-11-01 00:00:00

  • Effects of a multi-sensory environment on brain-injured patients: assessment of spectral patterns.

    abstract::Snoezelen(®) multi-sensory (SMS) environment has been commonly applied as a therapeutic strategy to alleviate the symptoms associated to a wide variety of pathologies. Despite most studies have reported a wide range of positive revealed short-term changes associated to SMS intervention, little has been done to systema...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.06.001

    authors: Poza J,Gómez C,Gutiérrez MT,Mendoza N,Hornero R

    更新日期:2013-03-01 00:00:00

  • Attention attraction in an ophthalmic diagnostic device using sound-modulated fixation targets.

    abstract::This study relates to eye fixation systems with combined optical and audio systems. Many devices for eye diagnostics and some devices for eye therapeutics require the patient to fixate on a small target for a certain period of time, during which the eyes do not move and data from substructures of one or both eyes are ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.05.004

    authors: Gramatikov BI,Rangarajan S,Irsch K,Guyton DL

    更新日期:2016-08-01 00:00:00

  • Motion quality evaluation of upper limb target-reaching movements.

    abstract::Fitts' Law was extended in the polar coordinate system, and a set of indices for human motion evaluation is proposed. In this paper, the index of difficulty and the index of performance are introduced as the general indices for the quality measure of plane target-to-target movement. As an example, the target-reaching ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00121-7

    authors: Yang N,Zhang M,Huang C,Jin D

    更新日期:2002-03-01 00:00:00

  • Genetic fuzzy modelling and control of bispectral index (BIS) for general intravenous anaesthesia.

    abstract::Based on an adaptive genetic fuzzy clustering algorithm, a derived fuzzy knowledge model is proposed for quantitatively estimating the systolic arterial pressure (SAP), heart rate (HR), and bispectral index (BIS) using 12 patients and it validates them according to pharmacological reasoning. Also, a genetic proportion...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.medengphy.2005.04.023

    authors: Shieh JS,Kao MH,Liu CC

    更新日期:2006-03-01 00:00:00

  • Assessment of the initial viscoelastic properties of a critical segmental long bone defect reconstructed with impaction bone grafting and intramedullary nailing.

    abstract:INTRODUCTION:This study compared the initial viscoelastic properties of a segmental tibial defect stabilized with intramedullary nailing and impaction bone grafting to that of a transverse fracture stabilized with intramedullary nailing. MATERIALS AND METHODS:Seven sheep tibiae were tested in compression (1000N), bend...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.09.003

    authors: Costi JJ,Stanley RM,Ding B,Solomon LB

    更新日期:2014-01-01 00:00:00

  • An e-caring chair for physiological signal measurement and recording.

    abstract::There is an increasing awareness among the populace of the need for regular health check-up to detect diseases in their early stages and thereby administer treatments in a timely fashion. However, commercially available physiological signal monitoring devices, which may offer clues on the onset of diseases, are time-c...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.04.011

    authors: Chang HT,Chung CG,Chen MW

    更新日期:2013-02-01 00:00:00

  • Two artificial neural systems for generation of gait swing by means of neuromuscular electrical stimulation.

    abstract::A three-layer artificial neural network was used for adaptive control of gait swing generated by neuromuscular electrical stimulation (NMES) in a spinal cord injured subject. Network inputs consisted of knee and ankle goniometer signals for System 1, and knee and hip angular data for System 2. Controller output was pr...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00030-6

    authors: Sepulveda F,Granat MH,Cliquet A Jr

    更新日期:1997-01-01 00:00:00

  • Technical quality evaluation of EEG recording based on electroencephalographers' knowledge.

    abstract::The aim of this study is to develop a technical quality evaluation system of electroencephalogram (EEG) recording in order to acquire technically satisfactory EEG records, which may contribute to the accuracy improvement of EEG interpretation. In our developed system, the evaluation of EEG recording comprises the dete...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.09.001

    authors: Nakamura M,Chen Q,Sugi T,Ikeda A,Shibasaki H

    更新日期:2005-01-01 00:00:00

  • Numerical analysis and experimental observation of guidewire motion in a blood vessel model.

    abstract::We have developed a computer-based system to simulate a guidewire in blood vessels for surgical planning, intra-operative assistance, and to facilitate the design of new guidewires. In this study, we compared simulation results with experimental results for validation of the simulation system. First, we inserted a com...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.09.012

    authors: Takashima K,Tsuzuki S,Ooike A,Yoshinaka K,Yu K,Ohta M,Mori K

    更新日期:2014-12-01 00:00:00

  • Is respiratory sinus arrhythmia present in atrial fibrillation? A study using two quantitative methods.

    abstract::Two quantitative techniques have been evaluated to examine whether respiratory sinus arrhythmia can be detected in atrial fibrillation. Cyclical changes in heart rate during deep breathing indicating respiratory sinus arrhythmia were seen in 11/15 control patients, but only 1/44 patients with atrial fibrillation. Powe...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/1350-4533(94)90061-2

    authors: Chandler ST,Trewby PN

    更新日期:1994-07-01 00:00:00

  • Sensorized pacifier to evaluate non-nutritive sucking in newborns.

    abstract::We developed a device for an objective measurement of non-nutritive sucking (NNS). NNS is newborns' spontaneous action that is a predictor of their neural system development and can be adopted as an intervention to train oral feeding skills in preterms. Two miniaturized digital pressure sensors were embedded into a co...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.12.013

    authors: Grassi A,Cecchi F,Sgherri G,Guzzetta A,Gagliardi L,Laschi C

    更新日期:2016-04-01 00:00:00

  • Multispectral classification techniques for terahertz pulsed imaging: an example in histopathology.

    abstract::Terahertz pulsed imaging is a spectroscopic imaging modality using pulses of electromagnetic radiation (100 GHz-10 THz), and there has been recent interest in studying biomedical specimens. It is usual to display parametric images derived from the measured pulses. In this work, classification was achieved by applying ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.02.011

    authors: Berry E,Handley JW,Fitzgerald AJ,Merchant WJ,Boyle RD,Zinov'ev NN,Miles RE,Chamberlain JM,Smith MA

    更新日期:2004-06-01 00:00:00

  • Development and validation of a robotic system for ankle joint testing.

    abstract::Ankle sprains are the most common sports injury. Gaining a better understanding of ankle mechanics will help improve current treatments, enabling a better quality of life for patients following surgery. In this paper, the development of a robotic system for ankle joint testing is presented. It is composed of an indust...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.10.002

    authors: El Daou H,Calder JD,Stephen JM

    更新日期:2018-12-01 00:00:00

  • Accelerometer based calf muscle pump activity monitoring.

    abstract::Long distance travel is associated with increased risk of deep vein thrombosis (DVT). There is an increased risk of travel related DVT in passengers with a predisposition to thrombosis. Assisting blood circulation in the lower limb will reduce the risk of DVT. Leg exercises are recommended as a DVT preventative measur...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.02.002

    authors: O'Donovan KJ,O'Keeffe DT,Grace PA,Lyons GM

    更新日期:2005-10-01 00:00:00

  • Separation of electrocardiographic from electromyographic signals using dynamic filtration.

    abstract::Trunk muscle electromyographic (EMG) signals are often contaminated by the electrical activity of the heart. During low or moderate muscle force, these electrocardiographic (ECG) signals disturb the estimation of muscle activity. Butterworth high-pass filters with cut-off frequency of up to 60 Hz are often used to sup...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.04.007

    authors: Christov I,Raikova R,Angelova S

    更新日期:2018-07-01 00:00:00

  • Effects of laminectomy and facetectomy on the stability of the lumbar motion segment.

    abstract::A ligamentous, nonlinear, sliding contact, three-dimensional finite element (FE) model of L2-L3 complex was developed to investigate the biomechanical effect of laminectomy with and without facetectomy. The L2-L3 FE model was validated against experimental study under various physiological loadings and found to match ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2003.11.006

    authors: Lee KK,Teo EC

    更新日期:2004-04-01 00:00:00

  • Electroactive polymeric sensors in hand prostheses: bending response of an ionic polymer metal composite.

    abstract::In stark contrast to the inspiring functionality of the natural hand, limitations of current upper limb prostheses stemming from marginal feedback control, challenges of mechanical design, and lack of sensory capacity, are well-established. This paper provides a critical review of current sensory systems and the poten...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.09.009

    authors: Biddiss E,Chau T

    更新日期:2006-07-01 00:00:00

  • Development and validation of an improved mechanical thorax for simulating cardiopulmonary resuscitation with adjustable chest stiffness and simulated blood flow.

    abstract::Investigations of compressive frequency, duty cycle, or waveform during CPR are typically rooted in animal research or computer simulations. Our goal was to generate a mechanical model incorporating alternate stiffness settings and an integrated blood flow system, enabling defined, reproducible comparisons of CPR effi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.02.005

    authors: Eichhorn S,Spindler J,Polski M,Mendoza A,Schreiber U,Heller M,Deutsch MA,Braun C,Lange R,Krane M

    更新日期:2017-05-01 00:00:00

  • In vivo estimation of normal left ventricular stiffness and contractility based on routine cine MR acquisition.

    abstract::Post-myocardial infarction remodeling process is known to alter the mechanical properties of the heart. Biomechanical parameters, such as tissue stiffness and contractility, would be useful for clinicians to better assess the severity of the diseased heart. However, these parameters are difficult to obtain in the curr...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.09.003

    authors: Rumindo GK,Ohayon J,Croisille P,Clarysse P

    更新日期:2020-11-01 00:00:00

  • Analysis of the effects of surface stiffness on the contact interaction between a finger and a cylindrical handle using a three-dimensional hybrid model.

    abstract::Contact interactions between the hand and handle, such as the contact surface softness and contact surface curvature, will affect both physical effort and musculoskeletal fatigue, thereby the comfort and safety of power tool operations. Previous models of hand gripping can be categorized into two groups: multi-body dy...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.03.007

    authors: Wu JZ,Dong RG,Warren CM,Welcome DE,McDowell TW

    更新日期:2014-07-01 00:00:00