Use of charged membranes to control interference by body chemicals in a glucose biosensor.

Abstract:

:The prerequisite for the continuous in vivo monitoring of glucose concentration is the development of an implantable glucose sensor with long-term stability. A new enzyme electrode concept featuring fluid-state glucose oxidase modified carbon powder along with a cross-linked glucose oxidase enzyme layer has been developed. The glucose sensor incorporating this enzyme electrode has been tested in vitro at 37 degrees C. It has a lifetime of three months after which it can be recharged with fresh enzyme. The next step in the characterization of this sensor is its in vitro behaviour in the presence of interfering substances commonly encountered in human blood. Here we report such a study of the sensor. The glucose diffusion membranes used were polycarbonate membranes. We used standard polycarbonate membranes (membranes treated with polyvinylpyrrolidone or PVP), PVP-free polycarbonate membranes, and standard polycarbonate membranes coated with positively and negatively charged hydrogel layers. The sensors showed a response to glucose concentrations < 300 mg dL-1, both in pure phosphate buffer and in the presence of interferences. The influence of ascorbic acid, bilirubin, creatinine, L-cystine, glycine, uric acid and urea on the amperometric signal of the sensor was investigated. The polycarbonate membrane coated with the negatively charged hydrogel layer provided good protection for the enzyme electrode, especially in the presence of ascorbic acid and uric acid.

journal_name

Med Eng Phys

authors

Vaidya R,Wilkins E

doi

10.1016/1350-4533(90)90008-v

subject

Has Abstract

pub_date

1994-09-01 00:00:00

pages

416-21

issue

5

eissn

1350-4533

issn

1873-4030

journal_volume

16

pub_type

杂志文章
  • Surgical instrumentation for the in vivo determination of human lumbar spinal segment stiffness and viscoelasticity.

    abstract::The definition of spinal instability is still controversial. For this reason, it is essential to better understand the difference in biomechanical behaviour between healthy and degenerated human spinal segments in vivo. A novel computer-assisted instrument was developed with the objective to characterize the biomechan...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.07.002

    authors: Ambrosetti-Giudici S,Pfenniger A,Krenn MH,Piotrowski WP,Ferguson SJ,Burger J

    更新日期:2009-11-01 00:00:00

  • A model identification approach to quantify impact of whole-body vertical vibrations on limb compliant dynamics and walking stability.

    abstract::Extensive research is ongoing in the field of orthoses/exoskeleton design for efficient lower limbs assistance. However, despite wearable devices reported to improve lower limb mobility, their structural impacts on whole-body vertical dynamics have not been investigated. This study introduced a model identification ap...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.04.005

    authors: Mahmood I,Martinez-Hernandez U,Dehghani-Sanij AA

    更新日期:2020-06-01 00:00:00

  • Comparison of isotropic and orthotropic material property assignments on femoral finite element models under two loading conditions.

    abstract::CT data has been widely used in the finite element modeling of bone. It can provide useful information on the geometrical topology and material properties of bone. Based on CT data, the assignment of bone material properties to finite element meshes is a fundamental step in the model generation. Most work done in this...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.06.003

    authors: Peng L,Bai J,Zeng X,Zhou Y

    更新日期:2006-04-01 00:00:00

  • Design of tissue engineering scaffolds based on hyperbolic surfaces: structural numerical evaluation.

    abstract::Tissue engineering represents a new field aiming at developing biological substitutes to restore, maintain, or improve tissue functions. In this approach, scaffolds provide a temporary mechanical and vascular support for tissue regeneration while tissue in-growth is being formed. These scaffolds must be biocompatible,...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.05.006

    authors: Almeida HA,Bártolo PJ

    更新日期:2014-08-01 00:00:00

  • A multi-sample denaturation temperature tester for collagenous biomaterials.

    abstract::The temperature at which collagen denatures from a triple helix to a random coil structure is a useful measure of the degree of crosslinking. A new multi-sample denaturation temperature tester (DTT) has been constructed for rapid determination of the collagen denaturation temperature of natural tissues and collagenous...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)91882-h

    authors: Lee JM,Pereira CA,Abdulla D,Naimark WA,Crawford I

    更新日期:1995-03-01 00:00:00

  • Dielectric elastomers as actuators for upper limb prosthetics: challenges and opportunities.

    abstract::Recent research has indicated that consumers of upper limb prostheses desire lighter-weight, anthropomorphic devices. The potential of dielectric elastomer (DE) actuators to better meet the design priorities of prosthesis users is explored. Current challenges are critically reviewed with respect to (1) durability, (2)...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2007.05.011

    authors: Biddiss E,Chau T

    更新日期:2008-05-01 00:00:00

  • Assessing the sound of cough towards vocality.

    abstract::The presented research positively evaluates the vocality of the cough sound by estimating the global cough fundamental frequency or pitch. The fundamental frequency was determined by autocorrelation analysis on both the original time-signal and the linear predicted time-signal. The experimental cough database was regi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00055-3

    authors: Van Hirtum A,Berckmans D

    更新日期:2002-09-01 00:00:00

  • Precision test apparatus for evaluating the heating pattern of radiofrequency ablation devices.

    abstract::Radiofrequency has established itself as a useful technique for managing cardiac arrhythmias and treating soft tissue tumors. However, despite its pervasive use, many of the biophysical principals needed to fully understand and optimize the radiofrequency ablation technique have not been explored. We have designed a t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00044-9

    authors: Chang I,Beard B

    更新日期:2002-11-01 00:00:00

  • Wear of polyethylene cups in total hip arthroplasty: a parametric mathematical model.

    abstract::This paper presents a parametric mathematical model of the head-cup wear coupling in total hip arthroplasty (THA). The model evaluates the dependence of acetabular volumetric wear upon the characteristic parameters of patient and hip prosthesis. Archard's law is assumed to calculate the wear coupling behaviour. The we...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00004-6

    authors: Pietrabissa R,Raimondi M,Di Martino E

    更新日期:1998-04-01 00:00:00

  • Robot assisted treadmill training: mechanisms and training strategies.

    abstract::The rehabilitation engineering community is working towards the development of robotic devices that can assist during gait training of patients suffering from neurologic injuries such as stroke and spinal cord injuries (SCI). The field of robot assisted treadmill training has rapidly evolved during the last decade. Th...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2010.12.010

    authors: Hussain S,Xie SQ,Liu G

    更新日期:2011-06-01 00:00:00

  • Optimised analytical models of the dielectric properties of biological tissue.

    abstract::The interaction of electromagnetic fields with the human body is quantified by the dielectric properties of biological tissues. These properties are incorporated into complex numerical simulations using parametric models such as Debye and Cole-Cole, for the computational investigation of electromagnetic wave propagati...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.01.017

    authors: Salahuddin S,Porter E,Krewer F,O' Halloran M

    更新日期:2017-05-01 00:00:00

  • A decentralized adaptive fuzzy robust strategy for control of upright standing posture in paraplegia using functional electrical stimulation.

    abstract::In this paper, we present a novel decentralized robust methodology for control of quiet upright posture during arm-free paraplegic standing using functional electrical stimulation (FES). Each muscle-joint complex is considered as a subsystem and individual controllers are designed for each one. Each controller operate...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.06.013

    authors: Kobravi HR,Erfanian A

    更新日期:2012-01-01 00:00:00

  • An MRI compatible loading device for the reconstruction of clinically relevant plantar pressure distributions and loading scenarios of the forefoot.

    abstract::The purpose of this study is to demonstrate a new MRI compatible loading device capable of reconstructing realistic loading scenarios of the human foot for research in the field of foot biomechanics. This device has two different configurations: one used to compress the forefoot and one to bend the metatarsophalangeal...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.06.006

    authors: Chatzistergos PE,Naemi R,Chockalingam N

    更新日期:2014-09-01 00:00:00

  • Wheelchair integrated occupant restraints: feasibility in frontal impact.

    abstract::Individuals often use their wheelchair as a motor vehicle seat when traveling in motor vehicles. The current use of fixed vehicle-mounted wheelchair occupant restraint systems (FWORSs) often results in poor belt fit and discomfort. Additionally, satisfaction, usability and usage rate of FWORSs during transit use are o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00082-0

    authors: VanRoosmalen L,Bertocci GE,Ha D,Karg P

    更新日期:2001-12-01 00:00:00

  • Porcine carotid arterial material property alterations with induced atheroma: an in vivo study.

    abstract:OBJECTIVE:A novel methodology has been developed to evaluate regional alterations in arterial wall material properties with induced atheroma in an animal model. METHODS:Atheromatous lesions (fatty, fibro-fatty, and fibrous) were induced in the carotid arteries of a Yucatan miniswine model by endothelial cell denudatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.09.014

    authors: Nagaraj A,Kim H,Hamilton AJ,Mun JH,Smulevitz B,Kane BJ,Yan LL,Roth SI,McPherson DD,Chandran KB

    更新日期:2005-03-01 00:00:00

  • Clinical workflow for personalized foot pressure ulcer prevention.

    abstract::Foot pressure ulcers are a common complication of diabetes because of patient's lack of sensitivity due to neuropathy. Deep pressure ulcers appear internally when pressures applied on the foot create high internal strains nearby bony structures. Monitoring tissue strains in persons with diabetes is therefore important...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.04.017

    authors: Bucki M,Luboz V,Perrier A,Champion E,Diot B,Vuillerme N,Payan Y

    更新日期:2016-09-01 00:00:00

  • Time-dependent analysis of leaflets in mechanical aortic bileaflet heart valves in closing phase using the finite strip method.

    abstract:BACKGROUND AND AIMS OF THE STUDY:Mechanical heart valves (MHV) are widely used to replace dysfunctional and failed heart valves. The bileaflet MHV design is very popular due to its superior hemodynamics. Since their introduction in 1977, the hemodynamics of bileaflet prostheses has been extensively studied. In this stu...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.03.013

    authors: Mohammadi H,Ahmadian MT,Wan WK

    更新日期:2006-03-01 00:00:00

  • Comparison of virtual and real electric powered wheelchair driving using a position sensing joystick and an isometric joystick.

    abstract::There are limited interface options for electric powered wheelchairs, which results in the inability of some individuals to drive independently. In addition, the development of new interface technologies will necessitate the development of alternative training methods. This study compares a conventional position sensi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00111-x

    authors: Cooper RA,Spaeth DM,Jones DK,Boninger ML,Fitzgerald SG,Guo S

    更新日期:2002-12-01 00:00:00

  • Measurement of ejection fraction with standard thermodilution catheters.

    abstract::Right ventricle ejection fraction (RVEF) is clinically used to evaluate right ventricular function. The thermodilution method can be modified to estimate the RVEF. However, this method requires a thermistor with a fast time response in order to yield correct estimates. Digital signal processing techniques that were de...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00026-7

    authors: dos Santos I,Ferreira da Rocha A,Assis de O Nascimento F,Souza Neto J,Valvano JW

    更新日期:2002-06-01 00:00:00

  • Including aortic valve morphology in computational fluid dynamics simulations: initial findings and application to aortic coarctation.

    abstract::Computational fluid dynamics (CFD) simulations quantifying thoracic aortic flow patterns have not included disturbances from the aortic valve (AoV). 80% of patients with aortic coarctation (CoA) have a bicuspid aortic valve (BAV) which may cause adverse flow patterns contributing to morbidity. Our objectives were to d...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.07.015

    authors: Wendell DC,Samyn MM,Cava JR,Ellwein LM,Krolikowski MM,Gandy KL,Pelech AN,Shadden SC,LaDisa JF Jr

    更新日期:2013-06-01 00:00:00

  • Implementation of a PC-based integrated control system for children.

    abstract::Children with severe physical disabilities often require a range of technological devices to aid them with the fundamental tasks carried out in everyday life. These tasks areas may include mobility, communication, environment control and computer access for education. The most efficient, and often the most cost-effect...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(94)90043-4

    authors: Hawley MS,Cudd PA,Cherry AD

    更新日期:1994-05-01 00:00:00

  • A method for determining the heat transfer and water vapour permeability of patient support systems.

    abstract::The formation of pressure ulcers can be exacerbated by a breakdown in the integrity of the patient's skin caused by poor maintenance of the skin microclimate. Patient support systems (PSSs-specialised beds, mattresses, chairs, cushions and pads) play an important role in the dissipation of heat and moisture away from ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00003-5

    authors: Nicholson GP,Scales JT,Clark RP,de Calcina-Goff ML

    更新日期:1999-12-01 00:00:00

  • Liquid ventilation: a mathematical model of gas diffusion in the premature lung.

    abstract::The liquid ventilation (LV) technique was previously demonstrated to be a valuable alternative to ordinary gas ventilation, particularly for newborn patients with severely distressed lungs. This work describes a mathematical model of gas transfer phenomena occurring within the lungs of a preterm newborn baby ventilate...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00041-0

    authors: Costantino ML,Fiore GB

    更新日期:1997-03-01 00:00:00

  • Current development in non-invasive glucose monitoring.

    abstract::Painless control of blood glycemic levels could improve life quality of diabetes patients, enabling a better regulation of hyper- and hypoglycaemia episodes and thereby avoiding physiological complications. Although research groups have been trying for decades to separate non-invasive glucose information from interfer...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2007.06.003

    authors: Ferrante do Amaral CE,Wolf B

    更新日期:2008-06-01 00:00:00

  • Bi-directional flow sensor with a wide dynamic range for medical applications.

    abstract::This paper describes a novel three-wire thermal flow sensor for medical applications. The present innovation for low-frequency measurements involves the use of a pulsed-wire anemometer with a comparatively large wire diameter (12.5 microm and larger) together with a novel signal processing approach. A small wire is he...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.06.002

    authors: Al-Salaymeh A,Jovanović J,Durst F

    更新日期:2004-10-01 00:00:00

  • Linear and nonlinear analyses of multi-channel mechanomyographic recordings reveal heterogeneous activation of wrist extensors in presence of delayed onset muscle soreness.

    abstract::In this study, we applied multi-channel mechanomyographic (MMG) recordings in combination with linear and nonlinear analyses to investigate muscular and musculotendinous effects of high intensity eccentric exercise. Twelve accelerometers arranged in a 3 × 4 matrix over the dominant elbow muscles were used to detect MM...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.09.003

    authors: Madeleine P,Hansen EA,Samani A

    更新日期:2014-12-01 00:00:00

  • An external portable device for adaptive deep brain stimulation (aDBS) clinical research in advanced Parkinson's Disease.

    abstract::Compared to conventional deep brain stimulation (DBS) for patients with Parkinson's Disease (PD), the newer approach of adaptive DBS (aDBS), regulating stimulation on the basis of the patient's clinical state, promises to achieve better clinical outcomes, avoid adverse-effects and save time for tuning parameters. A re...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.02.007

    authors: Arlotti M,Rossi L,Rosa M,Marceglia S,Priori A

    更新日期:2016-05-01 00:00:00

  • Computer simulation of commercial conductive gels and their application to increase the safety of electrochemotherapy treatment.

    abstract::Electrochemotherapy (ECT) exploits the phenomenon of electroporation, which is the increase of cell permeability through the application of an electrical field. This technique is applied in medical centers in Europe and in veterinary clinics in Europe, Brazil, and Argentina. ECT treatment requires a minimum electric f...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.09.016

    authors: Pintarelli GB,Berkenbrock JA,Rassele A,Rangel MMM,Suzuki DOH

    更新日期:2019-12-01 00:00:00

  • Influence of mouth opening on oropharyngeal humidification and temperature in a bench model of neonatal continuous positive airway pressure.

    abstract::Clinical studies show that non-invasive respiratory support by continuous positive airway pressure (CPAP) affects gas conditioning in the upper airways, especially in the presence of mouth leaks. Using a new bench model of neonatal CPAP, we investigated the influence of mouth opening on oropharyngeal temperature and h...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.12.005

    authors: Fischer HS,Ullrich TL,Bührer C,Czernik C,Schmalisch G

    更新日期:2017-02-01 00:00:00

  • Particle image velocimetry study of the celiac trunk hemodynamic induced by continuous-flow left ventricular assist device.

    abstract::Whereas left ventricular assist device (LVAD) is the gold-standard therapy for patients with heart failure, gastrointestinal bleeding is one of the most common complications. LVAD implantation may remarkably impact aortic hemodynamics so that experimental and computational flow analyses can be used to study the diseas...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.06.029

    authors: Scardulla F,Bellavia D,D'Acquisto L,Raffa GM,Pasta S

    更新日期:2017-09-01 00:00:00