Abstract:
:The prerequisite for the continuous in vivo monitoring of glucose concentration is the development of an implantable glucose sensor with long-term stability. A new enzyme electrode concept featuring fluid-state glucose oxidase modified carbon powder along with a cross-linked glucose oxidase enzyme layer has been developed. The glucose sensor incorporating this enzyme electrode has been tested in vitro at 37 degrees C. It has a lifetime of three months after which it can be recharged with fresh enzyme. The next step in the characterization of this sensor is its in vitro behaviour in the presence of interfering substances commonly encountered in human blood. Here we report such a study of the sensor. The glucose diffusion membranes used were polycarbonate membranes. We used standard polycarbonate membranes (membranes treated with polyvinylpyrrolidone or PVP), PVP-free polycarbonate membranes, and standard polycarbonate membranes coated with positively and negatively charged hydrogel layers. The sensors showed a response to glucose concentrations < 300 mg dL-1, both in pure phosphate buffer and in the presence of interferences. The influence of ascorbic acid, bilirubin, creatinine, L-cystine, glycine, uric acid and urea on the amperometric signal of the sensor was investigated. The polycarbonate membrane coated with the negatively charged hydrogel layer provided good protection for the enzyme electrode, especially in the presence of ascorbic acid and uric acid.
journal_name
Med Eng Physjournal_title
Medical engineering & physicsauthors
Vaidya R,Wilkins Edoi
10.1016/1350-4533(90)90008-vsubject
Has Abstractpub_date
1994-09-01 00:00:00pages
416-21issue
5eissn
1350-4533issn
1873-4030journal_volume
16pub_type
杂志文章abstract::The definition of spinal instability is still controversial. For this reason, it is essential to better understand the difference in biomechanical behaviour between healthy and degenerated human spinal segments in vivo. A novel computer-assisted instrument was developed with the objective to characterize the biomechan...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2009.07.002
更新日期:2009-11-01 00:00:00
abstract::Extensive research is ongoing in the field of orthoses/exoskeleton design for efficient lower limbs assistance. However, despite wearable devices reported to improve lower limb mobility, their structural impacts on whole-body vertical dynamics have not been investigated. This study introduced a model identification ap...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2020.04.005
更新日期:2020-06-01 00:00:00
abstract::CT data has been widely used in the finite element modeling of bone. It can provide useful information on the geometrical topology and material properties of bone. Based on CT data, the assignment of bone material properties to finite element meshes is a fundamental step in the model generation. Most work done in this...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2005.06.003
更新日期:2006-04-01 00:00:00
abstract::Tissue engineering represents a new field aiming at developing biological substitutes to restore, maintain, or improve tissue functions. In this approach, scaffolds provide a temporary mechanical and vascular support for tissue regeneration while tissue in-growth is being formed. These scaffolds must be biocompatible,...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.05.006
更新日期:2014-08-01 00:00:00
abstract::The temperature at which collagen denatures from a triple helix to a random coil structure is a useful measure of the degree of crosslinking. A new multi-sample denaturation temperature tester (DTT) has been constructed for rapid determination of the collagen denaturation temperature of natural tissues and collagenous...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(95)91882-h
更新日期:1995-03-01 00:00:00
abstract::Recent research has indicated that consumers of upper limb prostheses desire lighter-weight, anthropomorphic devices. The potential of dielectric elastomer (DE) actuators to better meet the design priorities of prosthesis users is explored. Current challenges are critically reviewed with respect to (1) durability, (2)...
journal_title:Medical engineering & physics
pub_type: 杂志文章,评审
doi:10.1016/j.medengphy.2007.05.011
更新日期:2008-05-01 00:00:00
abstract::The presented research positively evaluates the vocality of the cough sound by estimating the global cough fundamental frequency or pitch. The fundamental frequency was determined by autocorrelation analysis on both the original time-signal and the linear predicted time-signal. The experimental cough database was regi...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(02)00055-3
更新日期:2002-09-01 00:00:00
abstract::Radiofrequency has established itself as a useful technique for managing cardiac arrhythmias and treating soft tissue tumors. However, despite its pervasive use, many of the biophysical principals needed to fully understand and optimize the radiofrequency ablation technique have not been explored. We have designed a t...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(02)00044-9
更新日期:2002-11-01 00:00:00
abstract::This paper presents a parametric mathematical model of the head-cup wear coupling in total hip arthroplasty (THA). The model evaluates the dependence of acetabular volumetric wear upon the characteristic parameters of patient and hip prosthesis. Archard's law is assumed to calculate the wear coupling behaviour. The we...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(98)00004-6
更新日期:1998-04-01 00:00:00
abstract::The rehabilitation engineering community is working towards the development of robotic devices that can assist during gait training of patients suffering from neurologic injuries such as stroke and spinal cord injuries (SCI). The field of robot assisted treadmill training has rapidly evolved during the last decade. Th...
journal_title:Medical engineering & physics
pub_type: 杂志文章,评审
doi:10.1016/j.medengphy.2010.12.010
更新日期:2011-06-01 00:00:00
abstract::The interaction of electromagnetic fields with the human body is quantified by the dielectric properties of biological tissues. These properties are incorporated into complex numerical simulations using parametric models such as Debye and Cole-Cole, for the computational investigation of electromagnetic wave propagati...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2017.01.017
更新日期:2017-05-01 00:00:00
abstract::In this paper, we present a novel decentralized robust methodology for control of quiet upright posture during arm-free paraplegic standing using functional electrical stimulation (FES). Each muscle-joint complex is considered as a subsystem and individual controllers are designed for each one. Each controller operate...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.06.013
更新日期:2012-01-01 00:00:00
abstract::The purpose of this study is to demonstrate a new MRI compatible loading device capable of reconstructing realistic loading scenarios of the human foot for research in the field of foot biomechanics. This device has two different configurations: one used to compress the forefoot and one to bend the metatarsophalangeal...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.06.006
更新日期:2014-09-01 00:00:00
abstract::Individuals often use their wheelchair as a motor vehicle seat when traveling in motor vehicles. The current use of fixed vehicle-mounted wheelchair occupant restraint systems (FWORSs) often results in poor belt fit and discomfort. Additionally, satisfaction, usability and usage rate of FWORSs during transit use are o...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(01)00082-0
更新日期:2001-12-01 00:00:00
abstract:OBJECTIVE:A novel methodology has been developed to evaluate regional alterations in arterial wall material properties with induced atheroma in an animal model. METHODS:Atheromatous lesions (fatty, fibro-fatty, and fibrous) were induced in the carotid arteries of a Yucatan miniswine model by endothelial cell denudatio...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2004.09.014
更新日期:2005-03-01 00:00:00
abstract::Foot pressure ulcers are a common complication of diabetes because of patient's lack of sensitivity due to neuropathy. Deep pressure ulcers appear internally when pressures applied on the foot create high internal strains nearby bony structures. Monitoring tissue strains in persons with diabetes is therefore important...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.04.017
更新日期:2016-09-01 00:00:00
abstract:BACKGROUND AND AIMS OF THE STUDY:Mechanical heart valves (MHV) are widely used to replace dysfunctional and failed heart valves. The bileaflet MHV design is very popular due to its superior hemodynamics. Since their introduction in 1977, the hemodynamics of bileaflet prostheses has been extensively studied. In this stu...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2005.03.013
更新日期:2006-03-01 00:00:00
abstract::There are limited interface options for electric powered wheelchairs, which results in the inability of some individuals to drive independently. In addition, the development of new interface technologies will necessitate the development of alternative training methods. This study compares a conventional position sensi...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(02)00111-x
更新日期:2002-12-01 00:00:00
abstract::Right ventricle ejection fraction (RVEF) is clinically used to evaluate right ventricular function. The thermodilution method can be modified to estimate the RVEF. However, this method requires a thermistor with a fast time response in order to yield correct estimates. Digital signal processing techniques that were de...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(02)00026-7
更新日期:2002-06-01 00:00:00
abstract::Computational fluid dynamics (CFD) simulations quantifying thoracic aortic flow patterns have not included disturbances from the aortic valve (AoV). 80% of patients with aortic coarctation (CoA) have a bicuspid aortic valve (BAV) which may cause adverse flow patterns contributing to morbidity. Our objectives were to d...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2012.07.015
更新日期:2013-06-01 00:00:00
abstract::Children with severe physical disabilities often require a range of technological devices to aid them with the fundamental tasks carried out in everyday life. These tasks areas may include mobility, communication, environment control and computer access for education. The most efficient, and often the most cost-effect...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(94)90043-4
更新日期:1994-05-01 00:00:00
abstract::The formation of pressure ulcers can be exacerbated by a breakdown in the integrity of the patient's skin caused by poor maintenance of the skin microclimate. Patient support systems (PSSs-specialised beds, mattresses, chairs, cushions and pads) play an important role in the dissipation of heat and moisture away from ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(00)00003-5
更新日期:1999-12-01 00:00:00
abstract::The liquid ventilation (LV) technique was previously demonstrated to be a valuable alternative to ordinary gas ventilation, particularly for newborn patients with severely distressed lungs. This work describes a mathematical model of gas transfer phenomena occurring within the lungs of a preterm newborn baby ventilate...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(96)00041-0
更新日期:1997-03-01 00:00:00
abstract::Painless control of blood glycemic levels could improve life quality of diabetes patients, enabling a better regulation of hyper- and hypoglycaemia episodes and thereby avoiding physiological complications. Although research groups have been trying for decades to separate non-invasive glucose information from interfer...
journal_title:Medical engineering & physics
pub_type: 杂志文章,评审
doi:10.1016/j.medengphy.2007.06.003
更新日期:2008-06-01 00:00:00
abstract::This paper describes a novel three-wire thermal flow sensor for medical applications. The present innovation for low-frequency measurements involves the use of a pulsed-wire anemometer with a comparatively large wire diameter (12.5 microm and larger) together with a novel signal processing approach. A small wire is he...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2004.06.002
更新日期:2004-10-01 00:00:00
abstract::In this study, we applied multi-channel mechanomyographic (MMG) recordings in combination with linear and nonlinear analyses to investigate muscular and musculotendinous effects of high intensity eccentric exercise. Twelve accelerometers arranged in a 3 × 4 matrix over the dominant elbow muscles were used to detect MM...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.09.003
更新日期:2014-12-01 00:00:00
abstract::Compared to conventional deep brain stimulation (DBS) for patients with Parkinson's Disease (PD), the newer approach of adaptive DBS (aDBS), regulating stimulation on the basis of the patient's clinical state, promises to achieve better clinical outcomes, avoid adverse-effects and save time for tuning parameters. A re...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.02.007
更新日期:2016-05-01 00:00:00
abstract::Electrochemotherapy (ECT) exploits the phenomenon of electroporation, which is the increase of cell permeability through the application of an electrical field. This technique is applied in medical centers in Europe and in veterinary clinics in Europe, Brazil, and Argentina. ECT treatment requires a minimum electric f...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.09.016
更新日期:2019-12-01 00:00:00
abstract::Clinical studies show that non-invasive respiratory support by continuous positive airway pressure (CPAP) affects gas conditioning in the upper airways, especially in the presence of mouth leaks. Using a new bench model of neonatal CPAP, we investigated the influence of mouth opening on oropharyngeal temperature and h...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.12.005
更新日期:2017-02-01 00:00:00
abstract::Whereas left ventricular assist device (LVAD) is the gold-standard therapy for patients with heart failure, gastrointestinal bleeding is one of the most common complications. LVAD implantation may remarkably impact aortic hemodynamics so that experimental and computational flow analyses can be used to study the diseas...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2017.06.029
更新日期:2017-09-01 00:00:00