An improved approach for measurement of stroke volume during treadmill exercise.

Abstract:

:In this study, a new ensemble averaging technique was developed to measure cardiac output during treadmill exercise. Each dz/dt peak is used as a starting point for ensemble averaging, instead of the conventionally used R point of ECG, in order to prevent the peak dz/dt waveform (C point) to be smoothed, which results in increased dz/dtmax. When using the R point as a reference, time interval from the R point to the peak dz/dt varies for each heart beat. Signal to noise ratios (SNR) of the five subjects with the new technique were 12.9, 16. 4, 10.6, 14.0, and 4.6% higher than those with the conventional one at rest and during four levels of exercise, respectively. Power density spectra of the averaged dz/dt waveforms by the peak dz/dt and R point referencing were also analyzed. Stroke volumes of the five subjects averaged by the peak dz/dt were 4.9, 6.8, 7.6, 7.4, and 9.8% higher than those by the R point at rest and during four levels of exercise, respectively.

journal_name

Med Eng Phys

authors

Song CG,Kim DW

doi

10.1016/s1350-4533(03)00024-9

subject

Has Abstract

pub_date

2003-07-01 00:00:00

pages

517-22

issue

6

eissn

1350-4533

issn

1873-4030

pii

S1350453303000249

journal_volume

25

pub_type

临床试验,杂志文章
  • Validity of using wearable inertial sensors for assessing the dynamics of standing balance.

    abstract::Observational balance tests (e.g., Berg Balance Scale) are used to evaluate fall-risk. However, they tend to be subjective, and their reliability and sensitivity can be limited. The use of in-lab equipment for objective balance evaluation has not been common in clinical practice, due to the requirement of an equipped ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.10.018

    authors: Noamani A,Nazarahari M,Lewicke J,Vette AH,Rouhani H

    更新日期:2020-03-01 00:00:00

  • Validation of a C2-C7 cervical spine finite element model using specimen-specific flexibility data.

    abstract::This study presents a specimen-specific C2-C7 cervical spine finite element model that was developed using multiblock meshing techniques. The model was validated using in-house experimental flexibility data obtained from the cadaveric specimen used for mesh development. The C2-C7 specimen was subjected to pure continu...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.03.001

    authors: Kallemeyn N,Gandhi A,Kode S,Shivanna K,Smucker J,Grosland N

    更新日期:2010-06-01 00:00:00

  • Modelling the heart with the atrioventricular plane as a piston unit.

    abstract::Medical imaging and clinical studies have proven that the heart pumps by means of minor outer volume changes and back-and-forth longitudinal movements in the atrioventricular (AV) region. The magnitude of AV-plane displacement has also shown to be a reliable index for diagnosis of heart failure. Despite this, AV-plane...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.11.002

    authors: Maksuti E,Bjällmark A,Broomé M

    更新日期:2015-01-01 00:00:00

  • A portable monitoring system for measuring weight-bearing during tibial fracture healing.

    abstract::An ambulatory monitoring system has been developed to measure the weight-bearing achieved by a patient on their fractured leg. The system is lightweight, portable, and can monitor weight-bearing continuously over an extended period of time. In addition to mean weight-bearing, the system can also determine temporal par...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00061-7

    authors: Aranzulla PJ,Muckle DS,Cunningham JL

    更新日期:1998-10-01 00:00:00

  • Comparing passive angle-torque curves recorded simultaneously with a load cell versus an isokinetic dynamometer during dorsiflexion stretch tolerance assessments.

    abstract::The purpose of the present study was to compare the passive angle-torque curves and the passive stiffness (PS, N m °(-)(1)) values recorded simultaneously from a load cell versus an isokinetic dynamometer during dorsiflexion stretch tolerance assessments in vivo. Nine healthy men (mean ± SD age = 21.4 ± 1.6 years) com...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.02.010

    authors: Buckner SL,Jenkins ND,Costa PB,Ryan ED,Herda TJ,Cramer JT

    更新日期:2015-05-01 00:00:00

  • Multispectral classification techniques for terahertz pulsed imaging: an example in histopathology.

    abstract::Terahertz pulsed imaging is a spectroscopic imaging modality using pulses of electromagnetic radiation (100 GHz-10 THz), and there has been recent interest in studying biomedical specimens. It is usual to display parametric images derived from the measured pulses. In this work, classification was achieved by applying ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.02.011

    authors: Berry E,Handley JW,Fitzgerald AJ,Merchant WJ,Boyle RD,Zinov'ev NN,Miles RE,Chamberlain JM,Smith MA

    更新日期:2004-06-01 00:00:00

  • Extended Central Tendency Measure and difference plot for heart rate variability analysis.

    abstract::Heart rate variability (HRV) is a non-invasive alternative to analyze the role of the autonomic nervous system (ANS) on heart functioning. Many tools have been developed to analyze collected cardiac data. Among them, the Central Tendency Measure (CTM) is a quantitative method for variability analysis of RR intervals. ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.09.024

    authors: Belfort RAU,Treccossi SPC,Silva JLF,Pillat VG,Freitas CBN,Dos Santos L

    更新日期:2019-12-01 00:00:00

  • Development and evaluation of a semi-automatic technique for determining the bilateral symmetry plane of the facial skeleton.

    abstract::During reconstructive surgery of the face, one side may be used as a template for the other, exploiting assumed bilateral facial symmetry. The best method to calculate this plane, however, is debated. A new semi-automatic technique for calculating the symmetry plane of the facial skeleton is presented here that uses s...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.06.006

    authors: Willing RT,Roumeliotis G,Jenkyn TR,Yazdani A

    更新日期:2013-12-01 00:00:00

  • Application of soft tissue modelling to image-guided surgery.

    abstract::The deformation of soft tissue compromises the accuracy of image-guided surgery based on preoperative images, and restricts its applicability to surgery on or near bony structures. One way to overcome these limitations is to combine biomechanical models with sparse intraoperative data, in order to realistically warp t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2005.10.005

    authors: Carter TJ,Sermesant M,Cash DM,Barratt DC,Tanner C,Hawkes DJ

    更新日期:2005-12-01 00:00:00

  • Analysis of the effects of surface stiffness on the contact interaction between a finger and a cylindrical handle using a three-dimensional hybrid model.

    abstract::Contact interactions between the hand and handle, such as the contact surface softness and contact surface curvature, will affect both physical effort and musculoskeletal fatigue, thereby the comfort and safety of power tool operations. Previous models of hand gripping can be categorized into two groups: multi-body dy...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.03.007

    authors: Wu JZ,Dong RG,Warren CM,Welcome DE,McDowell TW

    更新日期:2014-07-01 00:00:00

  • An MRI compatible loading device for the reconstruction of clinically relevant plantar pressure distributions and loading scenarios of the forefoot.

    abstract::The purpose of this study is to demonstrate a new MRI compatible loading device capable of reconstructing realistic loading scenarios of the human foot for research in the field of foot biomechanics. This device has two different configurations: one used to compress the forefoot and one to bend the metatarsophalangeal...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.06.006

    authors: Chatzistergos PE,Naemi R,Chockalingam N

    更新日期:2014-09-01 00:00:00

  • Surgical instrumentation for the in vivo determination of human lumbar spinal segment stiffness and viscoelasticity.

    abstract::The definition of spinal instability is still controversial. For this reason, it is essential to better understand the difference in biomechanical behaviour between healthy and degenerated human spinal segments in vivo. A novel computer-assisted instrument was developed with the objective to characterize the biomechan...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.07.002

    authors: Ambrosetti-Giudici S,Pfenniger A,Krenn MH,Piotrowski WP,Ferguson SJ,Burger J

    更新日期:2009-11-01 00:00:00

  • Comparison of virtual and real electric powered wheelchair driving using a position sensing joystick and an isometric joystick.

    abstract::There are limited interface options for electric powered wheelchairs, which results in the inability of some individuals to drive independently. In addition, the development of new interface technologies will necessitate the development of alternative training methods. This study compares a conventional position sensi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00111-x

    authors: Cooper RA,Spaeth DM,Jones DK,Boninger ML,Fitzgerald SG,Guo S

    更新日期:2002-12-01 00:00:00

  • Smartphone application for emergency signal detection.

    abstract::Currently, a number of studies focus on the study and design of new healthcare technologies to improve elderly health and quality of life. Taking advantage of the popularity, portability, and inherent technology of smartphones, we present an emergency application for smartphones, designated as knock-to-panic (KTP). Th...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.05.002

    authors: Figueiredo IN,Leal C,Pinto L,Bolito J,Lemos A

    更新日期:2016-09-01 00:00:00

  • Identification of lower arm motions using the EMG signals of shoulder muscles.

    abstract::This investigation explored pattern recognition of EMG signals produced by shoulder area muscles to identify the performance of a select number of lower arm motions. The signals were modelled as fourth-order autoregressive processes with the parameters of the models used to classify the different motions. The recorded...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(94)90024-8

    authors: Latwesen A,Patterson PE

    更新日期:1994-03-01 00:00:00

  • Development of tissue adhesion method using integrated low-level energies.

    abstract::We have developed a method that allows biological tissues to be adhered together with minimal invasion by delivering integrated low-level energies from heat, pressure, and vibration. Tensile tests on adhered slices of porcine aorta were performed to determine the relationships between adhesive strength and conditions ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.12.005

    authors: Katoh A,Masuzawa T,Ozeki K,Kishida A,Kimura T,Higami T

    更新日期:2010-05-01 00:00:00

  • Biomechanical design using in-vitro finite element modeling of distal femur fracture plates made from semi-rigid materials versus traditional metals for post-operative toe-touch weight-bearing.

    abstract::This proof-of-concept study designs distal femur fracture plates from semi-rigid materials vs. traditional metals for toe-touch weight-bearing recommended to patients immediately after surgery. The two-fold goal was to (a) reduce stress shielding (SS) by increasing cortical bone stress thereby reducing the risk of bon...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.11.015

    authors: Gee A,Bougherara H,Schemitsch EH,Zdero R

    更新日期:2021-01-01 00:00:00

  • Time-dependent analysis of leaflets in mechanical aortic bileaflet heart valves in closing phase using the finite strip method.

    abstract:BACKGROUND AND AIMS OF THE STUDY:Mechanical heart valves (MHV) are widely used to replace dysfunctional and failed heart valves. The bileaflet MHV design is very popular due to its superior hemodynamics. Since their introduction in 1977, the hemodynamics of bileaflet prostheses has been extensively studied. In this stu...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.03.013

    authors: Mohammadi H,Ahmadian MT,Wan WK

    更新日期:2006-03-01 00:00:00

  • Effects of atrial contraction, atrioventricular interaction and heart valve dynamics on human cardiovascular system response.

    abstract::Various simulation models of different complexity have been proposed to model the dynamic response of the human cardiovascular system. In a related paper we proposed an improved numerical model to study the dynamic response of the cardiovascular system, and the pressures, volumes and flow-rates in the four chambers of...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.11.005

    authors: Korakianitis T,Shi Y

    更新日期:2006-10-01 00:00:00

  • How measurement artifacts affect cerebral autoregulation outcomes: A technical note on transfer function analysis.

    abstract::Cerebral autoregulation (CA) is the mechanism that aims to maintain adequate cerebral perfusion during changes in blood pressure (BP). Transfer function analysis (TFA), the most reported method in literature to quantify CA, shows large between-study variability in outcomes. The aim of this study is to investigate the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.02.001

    authors: Meel-van den Abeelen AS,de Jong DL,Lagro J,Panerai RB,Claassen JA

    更新日期:2016-05-01 00:00:00

  • Suitability of commercial barometric pressure sensors to distinguish sitting and standing activities for wearable monitoring.

    abstract::Despite its medical relevance, accurate recognition of sedentary (sitting and lying) and dynamic activities (e.g. standing and walking) remains challenging using a single wearable device. Currently, trunk-worn wearable systems can differentiate sitting from standing with moderate success, as activity classifiers often...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.01.001

    authors: Massé F,Bourke AK,Chardonnens J,Paraschiv-Ionescu A,Aminian K

    更新日期:2014-06-01 00:00:00

  • Biomechanical analysis of combining head-down tilt traction with vibration for different grades of degeneration of the lumbar spine.

    abstract::In recent years, a combination of traction and vibration therapy is usually used to alleviate low back pain (LBP) in clinical settings. Combining head-down tilt (HDT) traction with vibration was demonstrated to be efficacious for LBP patients in our previous study. However, the biomechanics of the lumbar spine during ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.10.004

    authors: Wang S,Wang L,Wang Y,Du C,Zhang M,Fan Y

    更新日期:2017-01-01 00:00:00

  • Recurrence quantification analysis as a tool for nonlinear exploration of nonstationary cardiac signals.

    abstract::The complexity, nonlinearity and nonstationarity of the cardiovascular system typically defy comprehensive and deterministic mathematical modeling, except from a statistical perspective. Living systems are governed by numerous, continuously changing, interacting variables in the presence of noise. Cardiovascular signa...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00112-6

    authors: Zbilut JP,Thomasson N,Webber CL

    更新日期:2002-01-01 00:00:00

  • Pulsatile impeller heart: a viable alternative to a problematic diaphragm heart.

    abstract::The impeller blood pump with its simplicity has many advantages compared with the diaphragm pump, but the nonpulsatile property has limited its applications. To make the impeller pump pulsatile, many investigations have been made in vain because of resulting haemolysis. The author has succeeded in producing a pulsatil...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)00010-0

    authors: Qian KX

    更新日期:1996-01-01 00:00:00

  • Parametric study on the interface pullout strength of the vertebral body replacement cage using FEM-based Taguchi methods.

    abstract::Improper design of vertebral body cages may seriously affect the interface strength and cause the lose of fixation for a vertebral body replacement. This research used a FEM-based Taguchi method to investigate the effects of various factors to find the robust design of the body cage. Three-dimensional finite element m...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.07.001

    authors: Hsu WH,Chao CK,Hsu HC,Lin J,Hsu CC

    更新日期:2009-04-01 00:00:00

  • A model identification approach to quantify impact of whole-body vertical vibrations on limb compliant dynamics and walking stability.

    abstract::Extensive research is ongoing in the field of orthoses/exoskeleton design for efficient lower limbs assistance. However, despite wearable devices reported to improve lower limb mobility, their structural impacts on whole-body vertical dynamics have not been investigated. This study introduced a model identification ap...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.04.005

    authors: Mahmood I,Martinez-Hernandez U,Dehghani-Sanij AA

    更新日期:2020-06-01 00:00:00

  • In vivo soft tissue damage assessment for applications in surgery.

    abstract::In robotic and conventional minimally invasive surgery the risk of complications caused by collateral tissue damage remains high. This paper studies the concept of imposing damage thresholds on surgical instruments to avoid tissue overload. More specifically, the correlation between mechanical loading and damage in ca...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.04.002

    authors: Famaey N,Verbeken E,Vinckier S,Willaert B,Herijgers P,Vander Sloten J

    更新日期:2010-06-01 00:00:00

  • Number and localization of the implants for the fixed prosthetic reconstructions: on the strain in the anterior maxillary region.

    abstract::Resorption following tooth loss and poor bone quality affect the success of implants in the anterior maxilla. Inappropriate planning can cause implant loss and aesthetics problems that are difficult to resolve. There is a limited literature on the optimum number and location of implants in anterior maxilla for fabrica...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.02.004

    authors: Bölükbaşı N,Yeniyol S

    更新日期:2015-04-01 00:00:00

  • Non-invasive identification of gastric contractions from surface electrogastrogram using back-propagation neural networks.

    abstract::Gastric contractions play an important role in the digestive process of the stomach. The established method for the measurement of gastric contractions is invasive and involves the insertion through the nose of a manometric probe into the stomach. A non-invasive method is introduced in this paper for the identificatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)95713-k

    authors: Chen JD,Lin Z,Wu Q,McCallum RW

    更新日期:1995-04-01 00:00:00

  • Electrochemistry of nanoscale DNA surface films on carbon.

    abstract::A DNA electrochemical biosensor is an integrated receptor-transducer device. The most important step in the development and manufacture of a sensitive DNA-biosensor for the detection of DNA-drug interactions is the immobilization procedure of the nucleic acid probe on the transducer surface. Magnetic A/C Mode atomic f...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2006.05.009

    authors: Oliveira-Brett AM,Paquim AM,Diculescu VC,Piedade JA

    更新日期:2006-12-01 00:00:00