Numerical simulation of the flow of aqueous humor in the Schlemm's canal.

Abstract:

:Schlemm's canal (SC) is a ring structure responsible for maintaining fluid homeostasis in the anterior chamber of the eye by draining aqueous humor (AH) from the trabecular meshwork (TM) into the collecting channel (CC). Obstruction of the AH flow in this conventional pathway leads to an elevation of intraocular pressure in glaucoma, which is internationally recognized as the most common cause of blindness. Although there are obvious morphological differences between patients and healthy individuals, the AH drainage capacity of SC with specific parameters is difficult to quantitatively evaluate due to the limitations of analyses or experimental technologies. In this paper, the AH flow dynamic features under various SC morphological parameters are studied by numerical simulations of 3D models. The axis length of the SC cross-section and the level of openness are chosen as the main morphological factors according to the clinical data. The flow features, including the velocity, streamline and wall shear stress, are analyzed. This study aimed not only to explore the feasibility of 3D numerical modeling in evaluating the SC drainage capacity, but also to reveal the relationship between SC morphological parameters and the dynamic features of AH drainage.

journal_name

Med Eng Phys

authors

Guo JM,Chen ZQ,Chen W,Yan XQ,Zhang H,Wang JM

doi

10.1016/j.medengphy.2020.12.005

subject

Has Abstract

pub_date

2021-02-01 00:00:00

pages

25-31

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(20)30185-5

journal_volume

88

pub_type

杂志文章
  • Development of a home ankle exerciser.

    abstract::A portable, lightweight home ankle exerciser was designed and built by the Biomedical Engineering Department of University Hospital in London, Ontario, Canada. The ankle exerciser incorporates several unique features that overcomes the drawbacks of exercise equipment presently available. For optimal muscle strengtheni...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)00057-7

    authors: Petrosenko RD,Vandervoort AA,Chesworth BM,Porter MM,Campbell GJ

    更新日期:1996-06-01 00:00:00

  • Including aortic valve morphology in computational fluid dynamics simulations: initial findings and application to aortic coarctation.

    abstract::Computational fluid dynamics (CFD) simulations quantifying thoracic aortic flow patterns have not included disturbances from the aortic valve (AoV). 80% of patients with aortic coarctation (CoA) have a bicuspid aortic valve (BAV) which may cause adverse flow patterns contributing to morbidity. Our objectives were to d...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.07.015

    authors: Wendell DC,Samyn MM,Cava JR,Ellwein LM,Krolikowski MM,Gandy KL,Pelech AN,Shadden SC,LaDisa JF Jr

    更新日期:2013-06-01 00:00:00

  • Electroactive polymeric sensors in hand prostheses: bending response of an ionic polymer metal composite.

    abstract::In stark contrast to the inspiring functionality of the natural hand, limitations of current upper limb prostheses stemming from marginal feedback control, challenges of mechanical design, and lack of sensory capacity, are well-established. This paper provides a critical review of current sensory systems and the poten...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.09.009

    authors: Biddiss E,Chau T

    更新日期:2006-07-01 00:00:00

  • fMRI brain mapping during motion capture and FES induced motor tasks: signal to noise ratio assessment.

    abstract::Functional Electrical Stimulation (FES) is a well known clinical rehabilitation procedure, however the neural mechanisms that underlie this treatment at Central Nervous System (CNS) level are still not completely understood. Functional magnetic resonance imaging (fMRI) is a suitable tool to investigate effects of reha...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.04.005

    authors: Gandolla M,Ferrante S,Casellato C,Ferrigno G,Molteni F,Martegani A,Frattini T,Pedrocchi A

    更新日期:2011-10-01 00:00:00

  • A predictive study of the mechanical behaviour of coronary stents by computer modelling.

    abstract::Intravascular stents are small tube-like structures expanded into stenotic arteries to restore blood flow perfusion to the downstream tissues. The stent expansion is an important factor to define the effectiveness of the surgical procedure: it depends on the stent geometry and includes large displacements and deformat...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.08.012

    authors: Migliavacca F,Petrini L,Montanari V,Quagliana I,Auricchio F,Dubini G

    更新日期:2005-01-01 00:00:00

  • Precision test apparatus for evaluating the heating pattern of radiofrequency ablation devices.

    abstract::Radiofrequency has established itself as a useful technique for managing cardiac arrhythmias and treating soft tissue tumors. However, despite its pervasive use, many of the biophysical principals needed to fully understand and optimize the radiofrequency ablation technique have not been explored. We have designed a t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00044-9

    authors: Chang I,Beard B

    更新日期:2002-11-01 00:00:00

  • Finite element analysis of side branch access during bifurcation stenting.

    abstract::Stent implantation has become a widely accepted endovascular intervention for the treatment of stenosed arteries. This minimally invasive technique has shown excellent results in unbranched arteries. However, stenting bifurcation lesions remains a challenge in coronary intervention as it is associated with a lower suc...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.11.013

    authors: Mortier P,De Beule M,Van Loo D,Verhegghe B,Verdonck P

    更新日期:2009-05-01 00:00:00

  • Variation of the impact duration during the in vitro insertion of acetabular cup implants.

    abstract::The acetabular cup (AC) is an implant impacted into a bone cavity and used for hip prosthesis surgery. Initial stability of the AC is an important factor for long term surgical success. The aim of this study is to determine the variations of the impact duration during AC implant insertion. Twenty-two bone samples take...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.04.005

    authors: Mathieu V,Michel A,Flouzat Lachaniette CH,Poignard A,Hernigou P,Allain J,Haïat G

    更新日期:2013-11-01 00:00:00

  • The Windkessel model revisited: a qualitative analysis of the circulatory system.

    abstract::In this paper, we derive a comprehensive computational model to estimate the arterial pressure and the cardiac output of humans, by refining and adapting the well-established equations of the Windkessel theory. The model inputs are based on patient specific factors such as age, sex, smoking and fitness habits as well ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.11.010

    authors: Tsanas A,Goulermas JY,Vartela V,Tsiapras D,Theodorakis G,Fisher AC,Sfirakis P

    更新日期:2009-06-01 00:00:00

  • Mechanical performance of Anatomic-Functional-Geometry dental treatments: A computational study.

    abstract::In this paper the biomechanical response of a novel dental preparation technique, referred to as the Anatomic-Functional-Geometry treatment (AFG), is investigated through a 3D nonlinear finite-element modelling approach. A comparative investigation against a standard technique employed in dental clinical practice is c...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.10.016

    authors: Gaziano P,Lorenzi C,Bianchi D,Monaldo E,Dolci A,Vairo G

    更新日期:2020-12-01 00:00:00

  • Influence of antegrade pulmonary blood flow on the hemodynamic performance of bidirectional cavopulmonary anastomosis: a numerical study.

    abstract::The role and effect of preserved antegrade pulmonary blood flow (APBF) at the time of bidirectional cavopulmonary anastomosis (BCPA) in the management of single-ventricle physiology is controversial. We investigated the influence of APBF on the fluid dynamics of BCPA connection using computational fluid dynamics (CFD)...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.07.004

    authors: Sun Q,Wan D,Liu J,Liu Y,Zhu M,Hong H,Sun Y,Wang Q

    更新日期:2009-03-01 00:00:00

  • Prediction of fracture location in the proximal femur using finite element models.

    abstract::Finite element (FE) models of the proximal femur are often used to study hip fracture. To interpret the results of these models, it is important to know whether the models accurately predict fracture location and/or type. This study evaluated the ability of automatically generated, CT scan-based linear FE models of th...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00094-7

    authors: Keyak JH,Rossi SA,Jones KA,Les CM,Skinner HB

    更新日期:2001-11-01 00:00:00

  • Morphology based anisotropic finite element models of the proximal femur validated with experimental data.

    abstract::Finite element analysis (FEA) of bones scanned with Quantitative Computed Tomography (QCT) can improve early detection of osteoporosis. The accuracy of these models partially depends on the assigned material properties, but anisotropy of the trabecular bone cannot be fully captured due to insufficient resolution of QC...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.08.010

    authors: Enns-Bray WS,Ariza O,Gilchrist S,Widmer Soyka RP,Vogt PJ,Palsson H,Boyd SK,Guy P,Cripton PA,Ferguson SJ,Helgason B

    更新日期:2016-11-01 00:00:00

  • Measurement of ejection fraction with standard thermodilution catheters.

    abstract::Right ventricle ejection fraction (RVEF) is clinically used to evaluate right ventricular function. The thermodilution method can be modified to estimate the RVEF. However, this method requires a thermistor with a fast time response in order to yield correct estimates. Digital signal processing techniques that were de...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00026-7

    authors: dos Santos I,Ferreira da Rocha A,Assis de O Nascimento F,Souza Neto J,Valvano JW

    更新日期:2002-06-01 00:00:00

  • New product development processes within the UK medical device industry.

    abstract::This paper reports on the findings of an extensive survey investigating practising design engineers' perceptions of new product development within the UK medical device industry. The design activity recorded was predominantly the small-scale development of low volume products. Explicit formal procedures were rarely us...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00021-5

    authors: Glen JM,Lord M

    更新日期:1996-12-01 00:00:00

  • Magnetic resonance-based thermometry during laser ablation on ex-vivo swine pancreas and liver.

    abstract::Laser Ablation (LA) is a minimally-invasive procedure for tumor treatment. LA outcomes depend on the heat distribution inside tissues and require accurate temperature measurement during the procedure. Magnetic resonance imaging (MRI) allows a non-invasive and three-dimensional thermometry of the organ undergoing LA. I...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.04.001

    authors: Allegretti G,Saccomandi P,Giurazza F,Caponero MA,Frauenfelder G,Di Matteo FM,Beomonte Zobel B,Silvestri S,Schena E

    更新日期:2015-07-01 00:00:00

  • Simulation-based particle swarm optimization and mechanical validation of screw position and number for the fixation stability of a femoral locking compression plate.

    abstract::Locking compression plates (LCPs) have been used to fix femoral shaft fractures. Previous studies have attempted to identify the best LCP screw positions and numbers to achieve the fixation stability. However, the determined screw positions and numbers were mainly based on the surgeons' experiences. The aim of this st...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.09.005

    authors: Lee CH,Shih KS,Hsu CC,Cho T

    更新日期:2014-01-01 00:00:00

  • A novel integrated mechanomyogram-vocalization access solution.

    abstract::We introduce a novel dual-switch control paradigm based on the simultaneous measurement of frontalis muscle mechanomyography (MMG) and vocalizations (humming) using a single contact microphone attached to the forehead. Vibrations of the face and skull during vocalization are manifested as periodic high-frequency compo...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.06.003

    authors: Alves N,Falk TH,Chau T

    更新日期:2010-10-01 00:00:00

  • Two artificial neural systems for generation of gait swing by means of neuromuscular electrical stimulation.

    abstract::A three-layer artificial neural network was used for adaptive control of gait swing generated by neuromuscular electrical stimulation (NMES) in a spinal cord injured subject. Network inputs consisted of knee and ankle goniometer signals for System 1, and knee and hip angular data for System 2. Controller output was pr...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00030-6

    authors: Sepulveda F,Granat MH,Cliquet A Jr

    更新日期:1997-01-01 00:00:00

  • Comparison of algorithms to quantify muscle fatigue in upper limb muscles based on sEMG signals.

    abstract::This work compared the performance of six different fatigue detection algorithms quantifying muscle fatigue based on electromyographic signals. Surface electromyography (sEMG) was obtained by an experiment from upper arm contractions at three different load levels from twelve volunteers. Fatigue detection algorithms m...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.09.009

    authors: Kahl L,Hofmann UG

    更新日期:2016-11-01 00:00:00

  • A biomechanical model to determine lumbosacral loads during single stance phase in normal gait.

    abstract::A dynamic biomechanical model to determine loads (joint forces) attained at the lumbosacral joint-centre during the stance phase of normal level walking was developed. The biomechanical model was based on rigid free body-segments; namely, the foot, shank, thigh, pelvis and head, arms and trunk (HAT) segments. In this ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)90374-k

    authors: Khoo BC,Goh JC,Bose K

    更新日期:1995-01-01 00:00:00

  • Probabilistic analysis of an uncemented total hip replacement.

    abstract::This paper describes the application of probabilistic design methods to the analysis of the behaviour of an uncemented total hip replacement femoral component implanted in a proximal femur. Probabilistic methods allow variations in factors which control the behaviour of the implanted femur (the input parameters) to be...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.01.002

    authors: Dopico-González C,New AM,Browne M

    更新日期:2009-05-01 00:00:00

  • Experimental determination of the emissivity of bone.

    abstract::Cutting and drilling operations in bone are involved in many orthopedic and otolaryngological surgeries. The temperature elevation of these procedures is potentially harmful to bone and soft tissue cells. The research on this topic aims therefore at minimizing temperature elevation and finding optimal process paramete...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.06.019

    authors: Feldmann A,Zysset P

    更新日期:2016-10-01 00:00:00

  • Number and localization of the implants for the fixed prosthetic reconstructions: on the strain in the anterior maxillary region.

    abstract::Resorption following tooth loss and poor bone quality affect the success of implants in the anterior maxilla. Inappropriate planning can cause implant loss and aesthetics problems that are difficult to resolve. There is a limited literature on the optimum number and location of implants in anterior maxilla for fabrica...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.02.004

    authors: Bölükbaşı N,Yeniyol S

    更新日期:2015-04-01 00:00:00

  • Can subject-specific single-fibre electrically evoked auditory brainstem response data be predicted from a model?

    abstract::This article investigates whether prediction of subject-specific physiological data is viable through an individualised computational model of a cochlear implant. Subject-specific predictions could be particularly useful to assess and quantify the peripheral factors that cause inter-subject variations in perception. T...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.09.001

    authors: Malherbe TK,Hanekom T,Hanekom JJ

    更新日期:2013-07-01 00:00:00

  • A complete, non-lumped, and verifiable set of upper body segment parameters for three-dimensional dynamic modeling.

    abstract::Dynamic models of the human trunk have been extensively used to investigate the biomechanics of lower back pain and postural instability in different populations. Despite their diverse applications, previous models rely on intrinsic upper body segment parameters (UBSP), e.g., each segment's mass-inertia characteristic...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.09.008

    authors: Vette AH,Yoshida T,Thrasher TA,Masani K,Popovic MR

    更新日期:2011-01-01 00:00:00

  • Evaluation of four blood pump geometries: fluorescent particle flow visualisation technique.

    abstract::Artificial blood pumps play an increasingly important role in the treatment of end-stage cardiac failure. The fluid dynamics of blood flow through such devices crucially affects their clinical effectiveness. Specifically, if the flow of blood stagnates or slowly re-circulates thrombus formation can occur and the avoid...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00023-0

    authors: Rose ML,Mackay TG,Wheatley DJ

    更新日期:2000-04-01 00:00:00

  • Evaluation of the magnitude of hip joint deformation in subjects with avascular necrosis of the hip joint during walking with and without Scottish Rite orthosis.

    abstract::The femoral head in subjects with leg calve perthes disease (LCPD) is generally considerably deformed. It is debatable whether this deformation is due to an increase in applied loads, a decrease in bone mineral density or a change in containment of articular surfaces. The aim of this study was to determine the influen...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.10.015

    authors: Karimi MT,Mohammadi A,Ebrahimi MH,McGarry A

    更新日期:2017-02-01 00:00:00

  • Assessment of the initial viscoelastic properties of a critical segmental long bone defect reconstructed with impaction bone grafting and intramedullary nailing.

    abstract:INTRODUCTION:This study compared the initial viscoelastic properties of a segmental tibial defect stabilized with intramedullary nailing and impaction bone grafting to that of a transverse fracture stabilized with intramedullary nailing. MATERIALS AND METHODS:Seven sheep tibiae were tested in compression (1000N), bend...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.09.003

    authors: Costi JJ,Stanley RM,Ding B,Solomon LB

    更新日期:2014-01-01 00:00:00

  • Development and evaluation of a semi-automatic technique for determining the bilateral symmetry plane of the facial skeleton.

    abstract::During reconstructive surgery of the face, one side may be used as a template for the other, exploiting assumed bilateral facial symmetry. The best method to calculate this plane, however, is debated. A new semi-automatic technique for calculating the symmetry plane of the facial skeleton is presented here that uses s...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.06.006

    authors: Willing RT,Roumeliotis G,Jenkyn TR,Yazdani A

    更新日期:2013-12-01 00:00:00