Abstract:
:Gait disturbances are common in the rat model of Parkinson's disease (PD) by administrating 6-hydroxydopamine. However, few studies have simultaneously assessed spatiotemporal gait indices and the kinematic information of PD rats during overground locomotion. This study utilized a simple, accurate, and reproducible method for quantifying the spatiotemporal and kinematic changes of gait patterns in hemiparkinsonian rats. A transparent walkway with a tilted mirror was set to capture underview footprints and lateral joint ankle images using a high-speed and high-resolution digital camera. The footprint images were semi-automatically processed with a threshold setting to identify the boundaries of soles and the critical points of each hindlimb for deriving the spatiotemporal and kinematic indices of gait. Following PD lesion, asymmetrical gait patterns including a significant decrease in the step/stride length and increases in the base of support and ankle joint angle were found. The increased footprint length, toe spread, and intermediary toe spread were found, indicating a compensatory gait pattern for impaired locomotor function. The temporal indices showed a significant decrease in the walking speed with increased durations of the stance/swing phase and double support time, which was more evident in the affected hindlimb. Furthermore, the ankle kinematic data showed that the joint angle decreased at the toe contact stage. We conclude that the proposed gait analysis method can be used to precisely detect locomotor function changes in PD rats, which is useful for objective assessments of investigating novel treatments for PD animal model.
journal_name
Med Biol Eng Computjournal_title
Medical & biological engineering & computingauthors
Lee HY,Hsieh TH,Liang JI,Yeh ML,Chen JJdoi
10.1007/s11517-012-0933-5subject
Has Abstractpub_date
2012-09-01 00:00:00pages
937-46issue
9eissn
0140-0118issn
1741-0444journal_volume
50pub_type
杂志文章abstract::Fetal heart rate (FHR) monitoring is used routinely in labor, but conventional methods have a limited capacity to detect fetal hypoxia/acidosis. An exploratory study was performed on the simultaneous assessment of maternal heart rate (MHR) and FHR variability, to evaluate their evolution during labor and their capacit...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1359-7
更新日期:2016-04-01 00:00:00
abstract::The objective of this study was to evaluate the effect of following combined treatment with parathyroid hormone (1-34) (PTH) and beta-tricalcium phosphate (β-TCP) on local bone formation in a rat 3-mm critical-size defect at distal femur. Twelve weeks after bilateral ovariectomy (OVX) and sham operation (sham), all an...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1402-8
更新日期:2016-09-01 00:00:00
abstract::A method for the identification of the breast boundary in mammograms is presented. The method can be used in the preprocessing stage of a system for computer-aided diagnosis (CAD) of breast cancer and also in the reduction of image file size in picture archiving and communication system applications. The method starte...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344632
更新日期:2004-03-01 00:00:00
abstract::Steady-state visual evoked potentials (SSVEPs) are widely employed in brain-computer interface (BCI) applications, especially to control machines. However, the use of SSVEPs leads to eye fatigue and causes lower accuracy over the long term, particularly when multi-commands are required. Therefore, this paper proposes ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-016-1560-3
更新日期:2017-06-01 00:00:00
abstract::The boundary-element method (BEM) is widely used for electrocardiogram (ECG) simulation. Its major disadvantage is its perceived inability to deal with the anisotropic electric conductivity of the myocardial interstitium, which led researchers to represent only intracellular anisotropy or neglect anisotropy altogether...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0472-x
更新日期:2009-07-01 00:00:00
abstract::The CellDrum technology (The term 'CellDrum technology' includes a couple of slightly different technological setups for measuring lateral mechanical tension in various types of cell monolayers or 3D-tissue constructs) was designed to quantify the contraction rate and mechanical tension of self-exciting cardiac myocyt...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0552-y
更新日期:2010-01-01 00:00:00
abstract::Electroencephalography (EEG) has been widely utilized to measure the depth of anaesthesia (DOA) during operation. However, the EEG signals are usually contaminated by artifacts which have a consequence on the measured DOA accuracy. In this study, an effective and useful filtering algorithm based on multivariate empiri...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-016-1598-2
更新日期:2017-08-01 00:00:00
abstract::Apoptosis proteins are related to many diseases. Obtaining the subcellular localization information of apoptosis proteins is helpful to understand the mechanism of diseases and to develop new drugs. At present, the researchers mainly focus on the primary protein sequences, so there is still room for improvement in the...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02045-3
更新日期:2019-12-01 00:00:00
abstract::Most tissues are subject to some form of physiological mechanical loading which results in deformation of the cells triggering intracellular mechanotransduction pathways. This response to loading is generally essential for the health of the tissue, although more pronounced deformation may result in cell and tissue dam...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-008-0381-4
更新日期:2008-10-01 00:00:00
abstract::This review is a commentary on recent, altered perspectives about biomedical engineering and its role in medicine. It is argued that, rather than being a peripheral specialty, medical engineering and engineering principles in general have a direct application to biochemical medicine and cell biology. A brief descripti...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/BF02446170
更新日期:1992-07-01 00:00:00
abstract::The Pennes bioheat equation and finite element method (FEM) are used to solve for the temperature distributions in the spinal cord and cerebrospinal fluid (CSF) during 30 min of cooling for spinal cord injury (SCI) patients. The average CSF and spinal cord temperatures are reduced by 3.48 and 2.72 degrees C, respectiv...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0543-z
更新日期:2010-02-01 00:00:00
abstract::The paper describes a method of quantifying Duchenne muscular dystrophy which is examiner independent and uses surface electromyographic signals (EMG). A standardised protocol is proposed. Spectral parameters are first computed from digitised EMG, then a polynomial model is deduced from the evolution of each parameter...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02446966
更新日期:1992-05-01 00:00:00
abstract::Stroke survivors are more prone to developing cognitive impairment and dementia. Dementia detection is a challenge for supporting personalized healthcare. This study analyzes the electroencephalogram (EEG) background activity of 5 vascular dementia (VaD) patients, 15 stroke-related patients with mild cognitive impairm...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-017-1734-7
更新日期:2018-01-01 00:00:00
abstract::A nonlinear prediction method for investigating the dynamic interdependence between short length time series is presented. The method is a generalization to bivariate prediction of the univariate approach based on nearest neighbor local linear approximation. Given the input and output series x and y, the relationship ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-006-0043-3
更新日期:2006-05-01 00:00:00
abstract::The performance of the stimulation coil in a magnetic nerve stimulator can be improved by attaching a ferromagnetic structure to the coil. This reduces heat generation at the coil and increases magnetic field strength for a given unit of current. Some technical aspects of the design of a stimulation coil with a ferrom...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345312
更新日期:2003-09-01 00:00:00
abstract::Portable biomedical instrumentation has become an important part of diagnostic and treatment instrumentation, including telemedicine applications. Low-voltage and low-power design tendencies prevail. Modern battery cell voltages in the range of 3-3.6 V require appropriate circuit solutions. A two-electrode biopotentia...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344642
更新日期:2004-03-01 00:00:00
abstract::Osteoporosis is one of the most common diseases that leads to bone fractures. Dual-energy X-ray absorptiometry is currently employed to measure the bone mineral density and to diagnose osteoporosis. Alternatively, the dielectric properties of bones are found to be influenced by bone mineral density; hence, dielectric ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-018-1887-z
更新日期:2019-01-01 00:00:00
abstract::Trabecular bone has a complicated porous microstructure and consists of interconnected plates and rods known as trabeculae. The microarchitecture of the trabeculae contributes to load distribution capacity and, particularly, the optimal bone strength. Many previous studies have shown that morphological parameters are ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-0951-3
更新日期:2012-10-01 00:00:00
abstract::In the case of female breast cancer, a breast-conserving excision is often desirable. This surgery is based on preoperatively gathered MRI, mammography, and sonography images. These images are recorded in multiple patient positions, e. g., 2D mammography images in standing position with a compressed breast and 3D MRI ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-01977-0
更新日期:2019-07-01 00:00:00
abstract::The regulation of cerebral blood flow (CBF) following changes in arterial blood pressure (ABP) and end-tidal pCO2 (EtCO2) are of clinical interest in assessing cerebrovascular reserve capacity. Linear finite-impulse-response modelling is applied to ABP, EtCO2 and CBF velocity (CBFV, from transcranial Doppler measureme...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345749
更新日期:2000-09-01 00:00:00
abstract::Computer-based simulations of human hip joints generally include investigating contacts happening among soft or hard tissues during hip movement. In many cases, hip movement is approximated as rotation about an estimated hip center. In this paper, we investigate the effect of different methods used for estimating hip ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-0873-0
更新日期:2012-06-01 00:00:00
abstract::In this study, the shape and the configuration of smooth muscle cells (SMCs) within the arterial wall are altered to investigate their influence on molecular transport across the media layer of the thoracic aorta wall. In a 2D geometry of the media layer containing SMCs, the finite-element method has been employed to ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-007-0219-5
更新日期:2007-11-01 00:00:00
abstract::Even though the World Health Organization criteria's for classifying the dengue infection have been used for long time, recent studies declare that several difficulties have been faced by the clinicians to apply these criteria. Accordingly, many studies have proposed modified criteria to identify the risk in dengue pa...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0561-x
更新日期:2010-03-01 00:00:00
abstract::Biomechanical models used to estimate joint loads often predict that antagonistic muscles are inactive or underestimate their contributions [3, 5]. This can result in systematic underestimation of muscle force predictions and joint contact forces. To test the feasibility of employing an empirical co-activation ratio t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-013-1081-2
更新日期:2014-03-01 00:00:00
abstract::This study is based on the hypothesis that the pressure within the arterial network can be usefully decomposed as the sum of a reservoir pressure and an excess pressure. The reservoir pressure waveform is defined to be the same in each vessel but delayed by the wave travel time from the root of the aorta. Using calcul...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-0872-1
更新日期:2012-04-01 00:00:00
abstract::The purpose of the study was to explore the application of artificial neural network model in the auxiliary diagnosis of lung cancer and compare the effects of back-propagation (BP) neural network with Fisher discrimination model for lung cancer screening by the combined detections of four biomarkers of p16, RASSF1A a...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-016-1585-7
更新日期:2017-08-01 00:00:00
abstract::Calcific aortic valve disease (CAVD) is characterized by calcification accumulation and thickening of the aortic valve cusps, leading to stenosis. The importance of fluid flow shear stress in the initiation and regulation of CAVD progression is well known and has been studied recently using fluid-structure interaction...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-016-1458-0
更新日期:2016-11-01 00:00:00
abstract::An eye pointer was developed as a new line-of-sight displacement analyser. It analyses an observer's eye movements and superimposes their line of vision on a TV image which is the same as their view. A newly developed miniature colour field camera and very compact eye-movement sensors are attached to a translucent rei...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02446149
更新日期:1990-07-01 00:00:00
abstract::The aim of the study is to establish the validity of the use of the electrical impedance technique for estimating local oedema in extremities through comparison with computed-tomography (CT) analysis. Eight healthy women (group 1) and nine women with unilateral leg oedema following chronic lymphatic obstruction (group...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02522859
更新日期:1998-01-01 00:00:00
abstract::There is a lack of information regarding the forces required for suturing human wounds. The knowledge of suturing forces serves as complementary information for setting up the limiting geometry when using tissue adhesives and it might also be used in robot-assisted surgery. The main purpose of this paper was to evalua...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-011-0857-5
更新日期:2012-02-01 00:00:00