Abstract:
:The regulation of cerebral blood flow (CBF) following changes in arterial blood pressure (ABP) and end-tidal pCO2 (EtCO2) are of clinical interest in assessing cerebrovascular reserve capacity. Linear finite-impulse-response modelling is applied to ABP, EtCO2 and CBF velocity (CBFV, from transcranial Doppler measurements), which allows the CBFV response to ideal step changes in EtCO2 to be estimated from clinical data showing more sluggish, and additional random variations. The confounding effects of ABP changes provoked by hypercapnia on the CBFV are also corrected for. Data from 56 patients suffering from stenosis of the carotid arteries (with normal or diminished cerebrovascular reactivity to EtCO2 changes--CVRCO2) were analysed. The results show the expected significant differences (p < 0.05) between EtCO2 steps up and down, the significant contribution from ABP variation, and also differences in the dynamic responses of patients with reduced CVRCO2 (p < 0.01 after 10 s). For the latter the CBFV response appears exhausted after about 15 s, whereas for normals CBFV continues to increase. While dispersion of individual step responses remains large, the method gives encouraging results for the non-invasive study of compromised haemodynamics in different patient groups.
journal_name
Med Biol Eng Computjournal_title
Medical & biological engineering & computingauthors
Simpson DM,Panerai RB,Evans DH,Garnham J,Naylor AR,Bell PRdoi
10.1007/BF02345749keywords:
subject
Has Abstractpub_date
2000-09-01 00:00:00pages
535-9issue
5eissn
0140-0118issn
1741-0444journal_volume
38pub_type
杂志文章abstract::This article presents a stimulation control method using a uniaxial gyroscope measuring angular velocity of the shank in the sagittal plane, to control functional electrical stimulation of the triceps surae to improve push-off of stroke subjects during gait. The algorithm is triggered during each swing phase of gait w...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0539-8
更新日期:2009-11-01 00:00:00
abstract::Conventional methods of electrobioimpedance imaging are not suited for adequate visualization of the skin electrical impedance landscape (SEL) because they do not provide high spatial resolution at large enough area of view. The skin electrodynamics introscopy (SEI) enabled dynamic spectral imaging of the SEL at 32 × ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-017-1668-0
更新日期:2018-02-01 00:00:00
abstract::A multichannel biopotential amplifier for simultaneous use with biomagnetic measurements in a magnetically shielded room is designed and evaluated. Particular care is taken to make the amplifier electromagnetically compatible with the biomagnetic instruments over the whole frequency spectrum, from DC to RF. The electr...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02534098
更新日期:1997-07-01 00:00:00
abstract::Tooth mobility examination is important in planning dental treatment, as it may give an indication of alveolar bone loss and the condition of the periodontal ligament. In clinical dental diagnosis a manual tooth mobility examination is useful. However, its determination of tooth mobility is subjective and depends on t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02442173
更新日期:1989-01-01 00:00:00
abstract::Computer-based simulations of human hip joints generally include investigating contacts happening among soft or hard tissues during hip movement. In many cases, hip movement is approximated as rotation about an estimated hip center. In this paper, we investigate the effect of different methods used for estimating hip ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-0873-0
更新日期:2012-06-01 00:00:00
abstract::This article compares the determination of body fat-free-mass (FFM) by impedance, using either hand-to-foot resistance (R₁₃) or foot-to-foot one (R₃₄) from comparison with dual X-ray absorptiometry (DXA) measurements in a normal population. The first goal was to see if the foot-to-foot resistance used in body fat anal...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-011-0827-y
更新日期:2011-11-01 00:00:00
abstract::A system is presented for the recording of physiological signals on an unmodified domestic videocassette recorder (VCR). A modification in the vertical synchronism pulses permits the recording of continuous analogue signals without significant loss of samples. The system allows up to 16 input channels, with a maximum ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02447101
更新日期:1991-03-01 00:00:00
abstract::A new system capable of generating static and dynamic random-element stereograms is designed and implemented. The stereogram is composed of a rectangle that can be varied in size, element density, orientation, and horizontal and vertical disparities, and can be swept at several velocities. The system is based on an in...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02524687
更新日期:1994-07-01 00:00:00
abstract::Dengue fever detection and classification have a vital role due to the recent outbreaks of different kinds of dengue fever. Recently, the advancement in the microarray technology can be employed for such classification process. Several studies have established that the gene selection phase takes a significant role in ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-017-1722-y
更新日期:2018-04-01 00:00:00
abstract::It is proposed that myo-electric signals can be used to augment conventional speech-recognition systems to improve their performance under acoustically noisy conditions (e.g. in an aircraft cockpit). A preliminary study is performed to ascertain the presence of speech information within myo-electric signals from facia...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345373
更新日期:2001-07-01 00:00:00
abstract::We present an analytical solution for the electrical potential and activating function (AF) established by cylindrical needle electrodes in anisotropic tissue. We compare this activating function to (1) AF computed assuming line-source electrodes and (2) AF computed using a finite element program. The results show tha...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0508-2
更新日期:2009-09-01 00:00:00
abstract::The study and applications of in vivo skin optics have been openly documented as early as the year 1954, or possibly earlier. To date, challenges in analyzing the complexities of this field remain, with wide scopes requiring more scrutiny. Recent advances in spectroscopic research and multivariate analytics allow a cl...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-019-02077-9
更新日期:2020-06-01 00:00:00
abstract::The objective of the present work was to develop automated methods for the compressed tracheal breathing sound analysis. Overnight tracheal breathing sound was recorded from ten apnoea patients. From each patient, three different types of tracheal sound deflection pattern, each of 10 min duration, were visually scored...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-008-0317-z
更新日期:2008-04-01 00:00:00
abstract::Long periods of bed rest negatively affect the human body organs, notably the cardiovascular system. To avert these negative effects and promote functional recovery in patients dealing with prolonged bed rest, the goal is to mobilize them as early as possible while controlling and stabilizing their cardiovascular syst...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-017-1628-8
更新日期:2017-09-01 00:00:00
abstract::Magnetoenterography (MENG) is a new, non-invasive technique that measures gastrointestinal magnetic signals near the body surface. This study was undertaken to evaluate the temporal and spatial characteristics of the magnetic signals generated by gastric and duodenal slow wave activity. The gastrointestinal magnetic f...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02513347
更新日期:1999-09-01 00:00:00
abstract::The Delft Shoulder and Elbow Model (DSEM), a musculoskeletal model of the shoulder and elbow has been extensively developed since its introduction in 1994. Extensions cover both model structures and anatomical data focusing on the addition of an elbow part and muscle architecture parameters. The model was also extende...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-011-0839-7
更新日期:2011-12-01 00:00:00
abstract::A new transducer has been developed, based on an inductive principle, for recording fetal movements and sounds. The compliance of this transducer, the INductive PHOno-sensor (INPHO), can be matched to that of the maternal abdomen to provide an optimal transfer of displacement between maternal abdomen and transducer. I...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02441655
更新日期:1991-07-01 00:00:00
abstract::Vascular access for renal dialysis is a lifeline for about 120 000 individuals in the United States. Stethoscope auscultation of vascular sounds has some utility in the assessment of access patency, yet can be highly skill-dependent. The objective of the study was to identify acoustic parameters that are related to ch...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345123
更新日期:2005-01-01 00:00:00
abstract::Currently, simulations of the induced currents in the brain produced by transcranial magnetic stimulation (TMS) are used to elucidate the regions reached by stimuli. However, models commonly found in the literature are too general and neglect imperfections in the windings. Aiming to predict the stimulation sites in pa...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-020-02156-2
更新日期:2020-07-01 00:00:00
abstract::A comparison of auditory and visual perception of scatterplots showed similar correlation estimation performance in both modalities. The present study replicated this experiment using electrotactile (electrocutaneous) presentation of scatterplots on the fingertips and abdomen, as well as visual presentation. The corre...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345967
更新日期:2005-03-01 00:00:00
abstract::A simple objective screening method for diagnosis of the atrial septal defect (ASD) is needed. Acoustic signals were collected from 61 children with ASD and 60 with a physiological murmur. The second heart sound (S2) and the spectrum of systolic murmur were analysed. A statistical model was designed using stepwise log...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-006-0094-5
更新日期:2006-09-01 00:00:00
abstract::The magnitude, mismatch and temporal variations of the electrode-gel-skin interface impedance can cause problems in electrical impedance tomography (EIT) measurement. It is shown that at the high frequencies generally encountered in EIT the capacitive properties of the electrode interface, and especially those of the ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/BF02523842
更新日期:1996-11-01 00:00:00
abstract::The relation is investigated between stimulus frequency, stimulus pulse amplitude and the neural damage induced by continuous stimulation of the cat's sciatic nerve. The chronically implanted electrodes were pulsed continuously and the effects of the electrical stimulation were quantified as the amount of early axonal...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02510526
更新日期:1995-05-01 00:00:00
abstract::Remote patient monitoring should reduce mortality rates, improve care, and reduce costs. We present an overview of the available technologies for the remote monitoring of chronic obstructive pulmonary disease (COPD) patients, together with the most important medical information regarding COPD in a language that is ada...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-018-1798-z
更新日期:2018-04-01 00:00:00
abstract::A previously proposed finite element model that considers geometric and material nonlinearities and the free boundary problems that occur at the catheter tip and in the annular zone around the lateral surface of the catheter was revised and was used to fit a power-law formula to predict backflow length during infusion...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-014-1187-1
更新日期:2014-10-01 00:00:00
abstract::The use of piezo-resistive uni-axial accelerometer signals in gait analysis is complicated by the fact that the measured signal is composed of different types of acceleration. The aim of the study is to obtain insight into the signal from a tangential accelerometer attached to the thigh during walking. Six subjects wa...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344868
更新日期:2000-11-01 00:00:00
abstract::Atrial fibrillation (AF) is the most common cardiac arrhythmia with episodes that may terminate spontaneously in the first stages of the disease. On the other hand, when the arrhythmia is not self-terminating, normal sinus rhythm (NSR) restoration use to be required to reduce the risk of stroke and improve cardiac out...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-008-0348-5
更新日期:2008-07-01 00:00:00
abstract::Multi-scale modeling of the musculoskeletal system plays an essential role in the deep understanding of complex mechanisms underlying the biological phenomena and processes such as bone metabolic processes. Current multi-scale models suffer from the isolation of sub-models at each anatomical scale. The objective of th...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-016-1572-z
更新日期:2017-06-01 00:00:00
abstract::Implantable cardioverter defibrillators (ICDs) can store intracardiac electrograms (EGMs) in sinus rhythm (SR), at the onset of spontaneous ventricular tachyarrhythmias (VT) or during their course. This allows the investigation of unknown features of the heart electrical activity associated with different cardiac rhyt...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-005-0014-0
更新日期:2006-03-01 00:00:00
abstract::Stroke survivors are more prone to developing cognitive impairment and dementia. Dementia detection is a challenge for supporting personalized healthcare. This study analyzes the electroencephalogram (EEG) background activity of 5 vascular dementia (VaD) patients, 15 stroke-related patients with mild cognitive impairm...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-017-1734-7
更新日期:2018-01-01 00:00:00