Advanced computational workflow for the multi-scale modeling of the bone metabolic processes.

Abstract:

:Multi-scale modeling of the musculoskeletal system plays an essential role in the deep understanding of complex mechanisms underlying the biological phenomena and processes such as bone metabolic processes. Current multi-scale models suffer from the isolation of sub-models at each anatomical scale. The objective of this present work was to develop a new fully integrated computational workflow for simulating bone metabolic processes at multi-scale levels. Organ-level model employs multi-body dynamics to estimate body boundary and loading conditions from body kinematics. Tissue-level model uses finite element method to estimate the tissue deformation and mechanical loading under body loading conditions. Finally, cell-level model includes bone remodeling mechanism through an agent-based simulation under tissue loading. A case study on the bone remodeling process located on the human jaw was performed and presented. The developed multi-scale model of the human jaw was validated using the literature-based data at each anatomical level. Simulation outcomes fall within the literature-based ranges of values for estimated muscle force, tissue loading and cell dynamics during bone remodeling process. This study opens perspectives for accurately simulating bone metabolic processes using a fully integrated computational workflow leading to a better understanding of the musculoskeletal system function from multiple length scales as well as to provide new informative data for clinical decision support and industrial applications.

journal_name

Med Biol Eng Comput

authors

Dao TT

doi

10.1007/s11517-016-1572-z

subject

Has Abstract

pub_date

2017-06-01 00:00:00

pages

923-933

issue

6

eissn

0140-0118

issn

1741-0444

pii

10.1007/s11517-016-1572-z

journal_volume

55

pub_type

杂志文章,评审
  • Monopole patch antenna for in vivo exposure to nanosecond pulsed electric fields.

    abstract::To explore the promising therapeutic applications of short nanosecond electric pulses, in vitro and in vivo experiments are highly required. In this paper, an exposure system based on monopole patch antenna is reported to perform in vivo experiments on newborn mice with both monopolar and bipolar nanosecond signals. A...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1547-0

    authors: Merla C,Apollonio F,Paffi A,Marino C,Vernier PT,Liberti M

    更新日期:2017-07-01 00:00:00

  • Fast body part segmentation and tracking of neonatal video data using deep learning.

    abstract::Photoplethysmography imaging (PPGI) for non-contact monitoring of preterm infants in the neonatal intensive care unit (NICU) is a promising technology, as it could reduce medical adhesive-related skin injuries and associated complications. For practical implementations of PPGI, a region of interest has to be detected ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02251-4

    authors: Antink CH,Ferreira JCM,Paul M,Lyra S,Heimann K,Karthik S,Joseph J,Jayaraman K,Orlikowsky T,Sivaprakasam M,Leonhardt S

    更新日期:2020-12-01 00:00:00

  • Usability of Computerized Lung Auscultation-Sound Software (CLASS) for learning pulmonary auscultation.

    abstract::The mastering of pulmonary auscultation requires complex acoustic skills. Computer-assisted learning tools (CALTs) have potential to enhance the learning of these skills; however, few have been developed for this purpose and do not integrate all the required features. Thus, this study aimed to assess the usability of ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1697-8

    authors: Machado A,Oliveira A,Jácome C,Pereira M,Moreira J,Rodrigues J,Aparício J,Jesus LMT,Marques A

    更新日期:2018-04-01 00:00:00

  • Statistical processing for gastric slow-wave identification.

    abstract::Successful identification of gastric slow waves in canine gastric electrical activity (GEA) data was achieved using a statistical data-processing procedure based on the multiple linear regression (MLR) curve fitting technique. Both distal and proximal waveforms were identified, first by construction of separate orthon...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345076

    authors: Grant MS,Williams RD

    更新日期:2002-07-01 00:00:00

  • Pain model and fuzzy logic patient-controlled analgesia in shock-wave lithotripsy.

    abstract::Pain control in conscious patients was investigated using a push-button, demand-driven supply of drugs. A fuzzy logic patient-controlled analgesia (PCA) algorithm was compared with a conventional algorithm, for alfentanil administration in extracorporeal shock-wave lithotripsy. The conventional PCA algorithm used an i...

    journal_title:Medical & biological engineering & computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF02347706

    authors: Shieh JS,Chang LW,Wang MS,Sun WZ,Wang YP,Yang YP

    更新日期:2002-01-01 00:00:00

  • Laser reflectance imaging of human organs and comparison with perfusion images.

    abstract::Based on the principle of backscattering of laser radiation from tissues, a non-invasive PC-AT based reflectance imaging technique is developed. The laser beam from a semiconductor laser operating at 670 nm is guided to the tissue site by an optical fibre. The backscattered radiation is collected by another fibre plac...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02530046

    authors: Shanthi S,Singh M

    更新日期:1997-05-01 00:00:00

  • Biopotential amplifier for simultaneous operation with biomagnetic instruments.

    abstract::A multichannel biopotential amplifier for simultaneous use with biomagnetic measurements in a magnetically shielded room is designed and evaluated. Particular care is taken to make the amplifier electromagnetically compatible with the biomagnetic instruments over the whole frequency spectrum, from DC to RF. The electr...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02534098

    authors: Virtanen J,Parkkonen L,Ilmoniemi RJ,Pekkonen E,Näätänen R

    更新日期:1997-07-01 00:00:00

  • Multi-parametric study of temperature and thermal damage of tumor exposed to high-frequency nanosecond-pulsed electric fields based on finite element simulation.

    abstract::High-frequency nanosecond-pulsed electric fields were recently introduced for tumor or abnormal tissue ablation to solve some problems of conventional electroporation. However, it is necessary to study the thermal effects of high-field-intensity nanosecond pulses inside tissues. The multi-parametric analysis performed...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1589-3

    authors: Mi Y,Rui S,Li C,Yao C,Xu J,Bian C,Tang X

    更新日期:2017-07-01 00:00:00

  • Some technical aspects of magnetic stimulation coil design with the ferromagnetic effect.

    abstract::The performance of the stimulation coil in a magnetic nerve stimulator can be improved by attaching a ferromagnetic structure to the coil. This reduces heat generation at the coil and increases magnetic field strength for a given unit of current. Some technical aspects of the design of a stimulation coil with a ferrom...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345312

    authors: Han BH,Lee SY,Kim JH,Yi JH

    更新日期:2003-09-01 00:00:00

  • Effects of sino-aortic denervation on spectral characteristics of blood pressure and pulse interval variability: a wide-band approach.

    abstract::Sino-aortic denervation (SAD) is employed in cats to evaluate the baroreflex influence on blood pressure (BP) and pulse interval (PI) spectral components from 0.00008 to 0.9 Hz as assessed by FFT wide-band spectra and their 1/f modelling; and the linear coupling between BP and PI and between systolic and diastolic BP ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02520018

    authors: Di Rienzo M,Castiglioni P,Parati G,Mancia G,Pedotti A

    更新日期:1996-03-01 00:00:00

  • Measurement of the local aortic stiffness by a non-invasive bioelectrical impedance technique.

    abstract::Aortic stiffness measurement is well recognized as an independent predictor of cardiovascular mortality and morbidity. Recently, a simple method has been proposed for the evaluation of the local aortic stiffness (AoStiff) using a non-invasive bioelectrical impedance (BI) technique. This approach relies on a novel inte...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0741-3

    authors: Collette M,Lalande A,Willoteaux S,Leftheriotis G,Humeau A

    更新日期:2011-04-01 00:00:00

  • Viscoelastic response of human hair cortex.

    abstract::The present study describes a new methodological approach which allows the separate analysis and quantitative determination of the viscous and elastic components of human hair using a computerised experimental system. In a first series of experiments subsequent to the estimation of the cross-sectional surface area of ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446198

    authors: Nikiforidis G,Balas C,Tsambaos D

    更新日期:1992-01-01 00:00:00

  • Matching between theoretical and experimental data for ELF ion transport effects.

    abstract::In recent years, several studies have been focused on the problem of nonthermal interaction between extremely low-frequency (ELF) electromagnetic fields and cell environment at membrane level. In the paper, to analyse the dynamic effects of weak static and harmonic fields on charged particles, some new considerations ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446654

    authors: D'Inzeo G,Galli A,Palombo A

    更新日期:1993-07-01 00:00:00

  • Analysis of biomechanical changes after removal of instrumentation in lumbar arthrodesis by finite element analysis.

    abstract::The purpose of this study is to investigate the change in biomechanical milieu following removal of pedicle screws in instrumented single level lumbar arthrodesis. Using a validated finite element (FE) model of the intact lumbar spine (L2-5), two scenarios of L3-4 lumbar fusion were simulated: posterolateral fusion (P...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0621-2

    authors: Kim HJ,Chun HJ,Moon SH,Kang KT,Kim HS,Park JO,Moon ES,Sohn JS,Lee HM

    更新日期:2010-07-01 00:00:00

  • A machine learning approach for magnetic resonance image-based mouse brain modeling and fast computation in controlled cortical impact.

    abstract::Computational modeling of the brain is crucial for the study of traumatic brain injury. An anatomically accurate model with refined details could provide the most accurate computational results. However, computational models with fine mesh details could take prolonged computation time that impedes the clinical transla...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02262-1

    authors: Lai C,Chen Y,Wang T,Liu J,Wang Q,Du Y,Feng Y

    更新日期:2020-11-01 00:00:00

  • Noninvasive measurement of blood glucose concentrations by analysing Fourier transform infra-red absorbance spectra through oral mucosa.

    abstract::Whether Fourier transform infra-red spectroscopy with an attenuated total reflection prism could be applied for noninvasive glucose measurement through oral mucosa was evaluated. As a result, the same absorbance peak at 1033 cm-1 as in glucose aqueous solution was found in the absorbance spectra through mucous membran...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446645

    authors: Kajiwara K,Uemura T,Kishikawa H,Nishida K,Hashiguchi Y,Uehara M,Sakakida M,Ichinose K,Shichiri M

    更新日期:1993-07-01 00:00:00

  • Analysis of amplitude and frequency variations of essential and Parkinsonian tremors.

    abstract::Variations in the amplitude and period of essential and Parkinsonian tremors were studied. It was found that the variations in frequency (or period) were mostly similar to the white noise, with the standard deviation typically less than 10% of the mean, whereas the variations in amplitude were much larger, with standa...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344710

    authors: Gao JB

    更新日期:2004-05-01 00:00:00

  • Automatic selection and feature extraction of motor-evoked potentials by transcranial magnetic stimulation in stroke patients.

    abstract::Transcranial magnetic stimulation (TMS) allows the assessment of stroke patients' cortical excitability and corticospinal tract integrity, which provide information regarding motor function recovery. However, the extraction of features from motor-evoked potentials (MEP) elicited by TMS, such as amplitude and latency, ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-021-02315-z

    authors: Tecuapetla-Trejo JE,Cantillo-Negrete J,Carrillo-Mora P,Valdés-Cristerna R,Ortega-Robles E,Arias-Carrion O,Carino-Escobar RI

    更新日期:2021-01-26 00:00:00

  • Effect of mains interference on time coherent averaging.

    abstract::The paper deals with the influence of mains interference on time coherent averaging using an internal trigger. The general distribution of the time jitter is derived and applied to a simplified signal. The authors prove that no amount of averaging can do away with this type of interference. Finally, the deformation th...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02457827

    authors: Strackee J,Peper A

    更新日期:1992-09-01 00:00:00

  • Reliability of the mechanomyogram detected with an accelerometer during voluntary contractions.

    abstract::The accelerometer is used for mechanomyogram (MMG) recordings of muscle contractions. Although the mechanical characteristics of other MMG transducers have been determined with reference to the accelerometer, mechanical aspects of the accelerometer itself, including the weight of the transducer, have not been verified...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344888

    authors: Watakabe M,Mita K,Akataki K,Ito K

    更新日期:2003-03-01 00:00:00

  • Increase in intrathoracic volume in pectus excavatum patients after the Nuss procedure.

    abstract::In this study, we present finite element analysis models to calculate the increase in intrathoracic volume of pectus excavatum patients after the Nuss procedure. One virtue of our approach is that the measurement of the intrathoracic volume has no time difference and is not affected by postoperative pain, which cannot...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0570-9

    authors: Chang PY,Hsu ZY,Lai JY,Wang CJ,Ching YT

    更新日期:2010-02-01 00:00:00

  • Dynamics of magnetic particles in cylindrical Halbach array: implications for magnetic cell separation and drug targeting.

    abstract::Magnetic nanoparticles for therapy and diagnosis are at the leading edge of the rapidly developing field of bionanotechnology. In this study, we have theoretically studied motion of magnetic nano- as well as micro-particles in the field of cylindrical Halbach array of permanent magnets. Magnetic flux density was model...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0636-8

    authors: Babinec P,Krafcík A,Babincová M,Rosenecker J

    更新日期:2010-08-01 00:00:00

  • Time-varying digital filtering of ECG baseline wander.

    abstract::Time-varying filtering techniques are applied to the problem of baseline correction by letting the cut-off frequency of a linear filter be controlled by the low-frequency properties of the ECG signal. The time-varying filter is implemented as a bank of linear low-pass filters, in which each filter has a slightly diffe...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441986

    authors: Sörnmo L

    更新日期:1993-09-01 00:00:00

  • Pulsatile blood flow in total cavopulmonary connection: a comparison between Y-shaped and T-shaped geometry.

    abstract::Single-ventricle anomaly is a hereditary heart disease that is characterized by anatomical malformations. The main consequence of this malformation is desaturated blood flow, which without proper treatment increases the risk of death. The classical treatment is based on a three-stage palliative procedure which should ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1499-4

    authors: Rajabzadeh-Oghaz H,Firoozabadi B,Saidi MS,Monjezi M,Navabi Shirazi MA,Malakan Rad E

    更新日期:2017-02-01 00:00:00

  • Combination of "generalized Trotter operator splitting" and "quadratic adaptive algorithm" method for tradeoff among speedup, stability, and accuracy in the Markov chain model of sodium ion channels in the ventricular cell model.

    abstract::The fast hybrid operator splitting (HOS) and stable uniformization (UNI) methods have been proposed to save computation cost and enhance stability for Markov chain model in cardiac cell simulations. Moreover, Chen-Chen-Luo's quadratic adaptive algorithm (CCL) combined with HOS or UNI was used to improve the tradeoff b...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02220-x

    authors: Chen XJ,Luo CH,Chen MH

    更新日期:2020-09-01 00:00:00

  • Effective identification and localization of immature precursors in bone marrow biopsy.

    abstract::Abnormal localization of immature precursors (ALIP) aggregating and clustering in bone marrow biopsy appears earlier than that of bone marrow smears in detection of the relapse of acute myelocytic leukemia (AML). But traditional manual ALIP recognition has many shortcomings such as prone to false alarms, neglect of di...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1223-1

    authors: Cao G,Li L,Chen W,Yu Y,Shi J,Zhang G,Liu X

    更新日期:2015-03-01 00:00:00

  • A computerized volumetric segmentation method applicable to multi-centre MRI data to support computer-aided breast tissue analysis, density assessment and lesion localization.

    abstract::Density assessment and lesion localization in breast MRI require accurate segmentation of breast tissues. A fast, computerized algorithm for volumetric breast segmentation, suitable for multi-centre data, has been developed, employing 3D bias-corrected fuzzy c-means clustering and morphological operations. The full br...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1484-y

    authors: Ertas G,Doran SJ,Leach MO

    更新日期:2017-01-01 00:00:00

  • Modeling the pharyngeal anatomical effects on breathing resistance and aerodynamically generated sound.

    abstract::The objective of this study was to systematically assess the effects of pharyngeal anatomical details on breathing resistance and acoustic characteristics by means of computational modeling. A physiologically realistic nose-throat airway was reconstructed from medical images. Individual airway anatomy such as the uvul...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1160-z

    authors: Xi J,Si X,Kim J,Su G,Dong H

    更新日期:2014-07-01 00:00:00

  • Industrial wideband noise reduction for hearing aids using a headset with adaptive-feedback active noise cancellation.

    abstract::High-intensity noises are a health hazard for industrial workers, and hearing protection is necessary to prevent hearing loss. Passive methods, such as ear muffs, are ineffective against low-frequency noise. Moreover, many hearing-impaired workers must wear hearing aids to enable communication at their workplace, and ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02430951

    authors: Lin JH,Li PC,Tang ST,Liu PT,Young ST

    更新日期:2005-11-01 00:00:00

  • Behaviour of two typical stents towards a new stent evolution.

    abstract::This study explores the analysis of a new stent geometry from two typical stents used to treat the coronary artery disease. Two different finite element methods are applied with different boundary conditions to investigate the stenosis region. Computational fluid dynamics (CFD) models including fluid-structure interac...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1574-x

    authors: Simão M,Ferreira JM,Mora-Rodriguez J,Fragata J,Ramos HM

    更新日期:2017-06-01 00:00:00