Abstract:
:Aortic stiffness measurement is well recognized as an independent predictor of cardiovascular mortality and morbidity. Recently, a simple method has been proposed for the evaluation of the local aortic stiffness (AoStiff) using a non-invasive bioelectrical impedance (BI) technique. This approach relies on a novel interpretation of the arterial stiffness where AoStiff is computed from the measurement of two new BI variables: (1) the local aortic flow resistance (AoRes) exerted by the drag forces onto the flow; (2) the local aortic wall distensibility (AoDist). Herein, we propose to detail and compare these three indices with the reference pulse wave velocity (PWV) measurement and the direct assessment of the aortic drag forces (DF) and distensibility (DS) obtained by the magnetic resonance imaging technique. Our results show a significant correlation between AoStiff and PWV (r = 0.79; P < 0.0001; 120 patients at rest; mean age 44 ± 16 years), and also between AoRes and DF (r = 0.95; P = 0.0011) and between AoDist and DS (r = 0.93; P = 0.0022) on eight patients at rest (mean age 52 ± 19 years). These first results suggest that local aortic stiffness can be explored reliably by the BI technique.
journal_name
Med Biol Eng Computjournal_title
Medical & biological engineering & computingauthors
Collette M,Lalande A,Willoteaux S,Leftheriotis G,Humeau Adoi
10.1007/s11517-011-0741-3subject
Has Abstractpub_date
2011-04-01 00:00:00pages
431-9issue
4eissn
0140-0118issn
1741-0444journal_volume
49pub_type
杂志文章abstract::The passive and active properties of the cochlear outer hair cell are studied. The outer hair cell is currently considered the major candidate for the active component of mammalian hearing. Understanding of its properties may explain the amplification and sharp frequency selectivity of the ear. To analyse the cell beh...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02513294
更新日期:1999-03-01 00:00:00
abstract::The physiological parameters of blood such as extracellular Na(+), K(+), Cl(-), pH, 2,3-DPG and ATP and the complex electrical impedance were measured using whole blood samples from 31 male donors (21 donors form the training set and ten donors were used for testing), on the 0th, 10th and 21st day of blood bank storag...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-007-0206-x
更新日期:2007-07-01 00:00:00
abstract::The changes in the power spectra of single-fibre extracellular action potentials (SFEAPs) generated in an infinite anisotropic frequency-dependent volume conductor, which occurred as a result of alterations in the propagation velocity v and duration T(in) of the intracellular action potential (IAP) were analytically d...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02446167
更新日期:1992-07-01 00:00:00
abstract::In the field of sports biomechanics and rehabilitation engineering, the possibility of computing, in real time, the angular displacements and derivatives of human joints, from a video of motion sequences, represents an appealing goal. In particular, applications of biofeedback protocols in rehabilitation can benefit f...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344878
更新日期:2003-03-01 00:00:00
abstract::To elucidate the mechanisms of localisation of intimal hyperplasia in anastomosed arteries, the effects of flow disturbances on the transport of low-density lipoproteins (LDLs) from the flowing blood to the wall of end-to-end anastomosed arteries, with and without a moderate stenosis, were studied theoretically by mea...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345458
更新日期:2002-09-01 00:00:00
abstract::Axial and transverse components of liquid velocity are measured by laser Doppler anemometer in a perspex tube that has been deformed at one point to resemble the shape of the throat of a partially collapsed flexible tube, conveying fluid while being compressed externally. The Reynolds number is 5900. The flow down-str...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345363
更新日期:2001-07-01 00:00:00
abstract::A multichannel biopotential amplifier for simultaneous use with biomagnetic measurements in a magnetically shielded room is designed and evaluated. Particular care is taken to make the amplifier electromagnetically compatible with the biomagnetic instruments over the whole frequency spectrum, from DC to RF. The electr...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02534098
更新日期:1997-07-01 00:00:00
abstract::Tissue hardness is related to tissue composition, and this is often changed by disease. It is therefore of interest to measure the hardness in an objective and non-invasive way. A tactile sensor based on a vibrating piezoelectric ceramic element in a feedback loop is described. When the sensor touches an object it pro...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02513357
更新日期:1999-09-01 00:00:00
abstract::This article presents a novel approach of edged and edgeless object-shape recognition and 3D reconstruction from gradient-based analysis of tactile images. We recognize an object's shape by visualizing a surface topology in our mind while grasping the object in our palm and also taking help from our past experience of...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-014-1142-1
更新日期:2014-04-01 00:00:00
abstract::The CellDrum technology (The term 'CellDrum technology' includes a couple of slightly different technological setups for measuring lateral mechanical tension in various types of cell monolayers or 3D-tissue constructs) was designed to quantify the contraction rate and mechanical tension of self-exciting cardiac myocyt...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0552-y
更新日期:2010-01-01 00:00:00
abstract::Heart sounds can be considered as mechanical fingerprints of myocardial function. The third heart sound normally occurs in children but disappears with maturation. The sound can also appear in patients with heart failure. The sound is characterised by its low-amplitude and low-frequency content, which makes it difficu...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345957
更新日期:2005-03-01 00:00:00
abstract::A new method of stimulation of the lower extremities was devised that automatically adjusts the stimulation conditions at any angle of the knee joint. An M-wave is considered to indicate the stimulation conditions, because it is the waveform that results from direct stimulation to the axon of the alpha motor neuron. T...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02351018
更新日期:2004-01-01 00:00:00
abstract::The performance of the stimulation coil in a magnetic nerve stimulator can be improved by attaching a ferromagnetic structure to the coil. This reduces heat generation at the coil and increases magnetic field strength for a given unit of current. Some technical aspects of the design of a stimulation coil with a ferrom...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345312
更新日期:2003-09-01 00:00:00
abstract::An algorithm for determining the frequency and propagation time of the gastric slow wave has been designed for integration into a demand gastric pacing system. The algorithm analyses the serosal activity in both the time and frequency domains, and the results are compared to produce a conclusion only when the values a...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344688
更新日期:2000-01-01 00:00:00
abstract::A new algorithm to resolve superimposed motor unit action potentials (MUAPs) is described, which uses a reduced search space and is based on the peel off approach. Knowledge specific to the problem domain, such as temporal relationships between and within motor unit action potential trains and MUAP energy information,...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02637020
更新日期:1996-01-01 00:00:00
abstract::Biomechanical models used to estimate joint loads often predict that antagonistic muscles are inactive or underestimate their contributions [3, 5]. This can result in systematic underestimation of muscle force predictions and joint contact forces. To test the feasibility of employing an empirical co-activation ratio t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-013-1081-2
更新日期:2014-03-01 00:00:00
abstract::This study explores the analysis of a new stent geometry from two typical stents used to treat the coronary artery disease. Two different finite element methods are applied with different boundary conditions to investigate the stenosis region. Computational fluid dynamics (CFD) models including fluid-structure interac...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-016-1574-x
更新日期:2017-06-01 00:00:00
abstract::Segmentation and classification of low-quality and noisy ultrasound images is challenging task. In this paper, a new approach is proposed for robust segmentation and classification of carotid artery ultrasound images and consequently, detecting cerebrovascular disease. The proposed technique consists of two phases, in...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-016-1481-1
更新日期:2016-12-01 00:00:00
abstract::In a computer-aided diagnosis (CAD) system, especially for chest radiograph or chest X-ray (CXR) screening, CXR image view information is required. Automatically separating CXR image view, frontal and lateral can ease subsequent CXR screening process, since the techniques may not equally work for both views. We presen...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-018-1786-3
更新日期:2018-08-01 00:00:00
abstract::Quantitative sensory testing (QST) can provide useful information about the underlying mechanisms involved in chronic pain. However, currently available devices typically employed suffer from operator-dependent effects, or are too cumbersome for routine clinical care. This paper presents the design and initial validat...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-013-1033-x
更新日期:2013-06-01 00:00:00
abstract::The magnitude, mismatch and temporal variations of the electrode-gel-skin interface impedance can cause problems in electrical impedance tomography (EIT) measurement. It is shown that at the high frequencies generally encountered in EIT the capacitive properties of the electrode interface, and especially those of the ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/BF02523842
更新日期:1996-11-01 00:00:00
abstract::A new ambulatory technique for qualitative and quantitative movement analysis of the humerus is presented. 3D gyroscopes attached on the humerus were used to recognize the movement of the arm and to classify it as flexion, abduction and internal/external rotations. The method was first validated in a laboratory settin...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0464-x
更新日期:2009-05-01 00:00:00
abstract::The problem of excess cerebrospinal fluid in the brain (hydrocephalus) is generally managed using a passive pressure or flow regulated mechanical shunt. Despite the success of such devices, they have been plagued with a number of problems. It is desirable to have a shunt valve that responds dynamically to the changing...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-010-0716-9
更新日期:2011-01-01 00:00:00
abstract::In this paper, a method for apnea bradycardia detection in preterm infants is presented based on coupled hidden semi Markov model (CHSMM). CHSMM is a generalization of hidden Markov models (HMM) used for modeling mutual interactions among different observations of a stochastic process through using finite number of hi...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-020-02277-8
更新日期:2021-01-01 00:00:00
abstract::In electrocardiographic imaging (ECGI), one solves the inverse problem of electrocardiography (ECG) to reconstruct equivalent cardiac sources based on the body surface potential measurements and a mathematical model of the torso. Due to attenuation and spatial smoothing within the torso, this inverse problem is ill-po...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02018-6
更新日期:2019-10-01 00:00:00
abstract::Left ventricular assist devices (LVAD) emerges as an effective clinical device providing life-saving support to heart patients. The design of blood pump of an LVAD involves incredible accuracy and thorough understanding of hemodynamics to mimic the functionality of a healthy ventricle. This work studies hemodynamics a...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02097-5
更新日期:2020-02-01 00:00:00
abstract::Respiratory sinus arrhythmia (RSA) is the variation of heart rate (or RR interval) in phase with respiration and has been extensively studied. However, the effect of respiration on atrioventricular conduction delay (and hence PR interval length) has not yet received much attention. This work reports on measurements of...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345298
更新日期:2002-11-01 00:00:00
abstract::Musculoskeletal models have been developed to estimate internal loading on the human skeleton, which cannot directly be measured in vivo, from external measurements like kinematics and external forces. Such models of the shoulder and upper extremity have been used for a variety of purposes, ranging from understanding ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-013-1099-5
更新日期:2013-09-01 00:00:00
abstract::Tooth mobility examination is important in planning dental treatment, as it may give an indication of alveolar bone loss and the condition of the periodontal ligament. In clinical dental diagnosis a manual tooth mobility examination is useful. However, its determination of tooth mobility is subjective and depends on t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02442173
更新日期:1989-01-01 00:00:00
abstract::Functional magnetic resonance imaging (FMRI) is an imaging technique for determining which regions of the brain are activated in response to a stimulus or event. Early FMRI experiment paradigms were based upon those used in positron emission tomography (PET), i.e. employing a block design consisting of extended period...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02347541
更新日期:2004-09-01 00:00:00