Statistical processing for gastric slow-wave identification.

Abstract:

:Successful identification of gastric slow waves in canine gastric electrical activity (GEA) data was achieved using a statistical data-processing procedure based on the multiple linear regression (MLR) curve fitting technique. Both distal and proximal waveforms were identified, first by construction of separate orthonormal bases from pre-selected sets of representative distal and proximal gastric slow waves (GSWs). Respective basis matrices were used to fit proximal and distal data to an MLR data model. Residual waveforms were computed from the original and 'fitted' waveforms and used in identifying GSWs in the data. Canine GEA data were split into 1,800-point blocks, and each 245-point data segment in a block was processed to identify the GSWs. Gastric slow waves were located in the data using a residual mean-squared error (MSE) threshold and, for distal GEA data, the minimum value of the main distal waveform peak. All threshold values were determined empirically and were set to detect GSWs while limiting false matches. Identification rates of 95% and 99% for proximal and distal GSWs, respectively, represent a significant improvement over those obtained in a previous study in which the same data were analysed using linear signal-processing methods. The use of the method presented in this paper for real-time identification of GSWs in conjunction with an implantable gastric pacer unit appears promising. Because the technique is inherently customisable, results obtained in this study should also be applicable to human subjects.

journal_name

Med Biol Eng Comput

authors

Grant MS,Williams RD

doi

10.1007/BF02345076

keywords:

subject

Has Abstract

pub_date

2002-07-01 00:00:00

pages

432-8

issue

4

eissn

0140-0118

issn

1741-0444

journal_volume

40

pub_type

杂志文章
  • CSF dynamic analysis of a predictive pulsatility-based infusion test for normal pressure hydrocephalus.

    abstract::Disturbed cerebrospinal fluid (CSF) dynamics are part of the pathophysiology of normal pressure hydrocephalus (NPH) and can be modified and treated with shunt surgery. This study investigated the contribution of established CSF dynamic parameters to AMP(mean), a prognostic variable defined as mean amplitude of cardiac...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1110-1

    authors: Qvarlander S,Malm J,Eklund A

    更新日期:2014-01-01 00:00:00

  • Optimal chest compression in cardiopulmonary resuscitation depends upon thoracic and back support stiffness.

    abstract::A biomechanical analysis of the constant peak displacement and constant peak force methods of cardiopulmonary resuscitation (CPR) has revealed that optimal CC performance strongly depends on back support stiffness, CC rate, and the thoracic stiffness of the patient being resuscitated. Clinically the results presented ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0963-z

    authors: Dellimore KH,Scheffer C

    更新日期:2012-12-01 00:00:00

  • Noise reduction in magnetocardiography by singular value decomposition and independent component analysis.

    abstract::In the routine recording of magnetocardiograms (MCGs), it is necessary to underline the problem of noise cancellation. Source separation has often been suggested to solve this problem. In this paper, blind source separation (BSS), by means of singular value decomposition (SVD) and independent component analysis (ICA),...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0055-z

    authors: DiPietroPaolo D,Müller HP,Nolte G,Erné SN

    更新日期:2006-06-01 00:00:00

  • Improvement of spike train decoder under spike detection and classification errors using support vector machine.

    abstract::The successful decoding of kinematic variables from spike trains of motor cortical neurons is essential for cortical neural prosthesis. Spike trains from each single unit must be extracted from extracellular neural signals and, thus, spike detection and sorting procedure is indispensable but the detection and sorting ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-005-0009-x

    authors: Kim KH,Kim SS,Kim SJ

    更新日期:2006-03-01 00:00:00

  • Visualisation method of spatial interictal discharges in temporal epilepsy patients using magneto-encephalogram.

    abstract::The aim of the study was to develop a method for investigating how interictal epileptic discharges in temporal epilepsy patients are activated spatially. The activity was measured using magneto-encephalography (MEG). The MEG data were used to produce a current-arrow map that reflected the topographic distribution of t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344215

    authors: Kandori A,Oe H,Miyashita K,Date H,Yamada N,Naritomi H,Chiba Y,Murakami M,Miyashita T,Tsukada K

    更新日期:2002-05-01 00:00:00

  • Effect of signal length on the performance of independent component analysis when extracting the lambda wave.

    abstract::The aim of the study was to investigate the effect of signal length on the performance of a signal source separation method, independent component analysis (ICA), when extracting the visual evoked potential (EP) lambda wave from saccade-related electro-encephalogram (EEG) waveforms. A method was devised that enabled t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348134

    authors: Vigon L,Saatchi R,Mayhew JE,Taroyan NA,Frisby JP

    更新日期:2002-03-01 00:00:00

  • Analysis of the O-wave in acute right ventricular apex impedance measurements with a standard pacing lead in animals.

    abstract::Modern pacemakers (implantable devices used for maintaining an appropriate heart rate in patients) can use an intracardiac ventricular impedance signal for physiological cardiac stimulation control. Intracardiac ventricular impedance from nine animal subjects is analysed and presented (seven sheep: 49.0 +/- 6.5 kg, si...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345448

    authors: Järverud K,Ollmar S,Brodin LA

    更新日期:2002-09-01 00:00:00

  • Dynamic simulation of the natural and replaced human ankle joint.

    abstract::Disappointing results for total ankle replacement have been explained by poor knowledge of the mechanics of the intact and replaced joints. Dynamic simulation tools have the capacity to simulate dynamic conditions that occur in human joints. The Working Model 2D tool was used to simulate the mechanics of the intact an...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348124

    authors: Leardini A,Moschella D

    更新日期:2002-03-01 00:00:00

  • Extraction of Cole parameters from the electrical bioimpedance spectrum using stochastic optimization algorithms.

    abstract::Fitting the measured bioimpedance spectroscopy (BIS) data to the Cole model and then extracting the Cole parameters is a common practice in BIS applications. The extracted Cole parameters then can be analysed as descriptors of tissue electrical properties. To have a better evaluation of physiological or pathological p...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1355-y

    authors: Gholami-Boroujeny S,Bolic M

    更新日期:2016-04-01 00:00:00

  • Spatial and temporal variations in the magnetic fields produced by human gastrointestinal activity.

    abstract::Magnetoenterography (MENG) is a new, non-invasive technique that measures gastrointestinal magnetic signals near the body surface. This study was undertaken to evaluate the temporal and spatial characteristics of the magnetic signals generated by gastric and duodenal slow wave activity. The gastrointestinal magnetic f...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513347

    authors: Turnbull GK,Ritcey SP,Stroink G,Brandts B,van Leeuwen P

    更新日期:1999-09-01 00:00:00

  • Analysis of the first heart sound using the matching pursuit method.

    abstract::It is acknowledged that the first heart sound S1 consists of two major, high-frequency components M1 and T1, corresponding, respectively, to the vibrations of the mitral and tricuspid valves and their surrounding tissues following valve closure in early systole. In this study, the matching pursuit (MP) method was used...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345436

    authors: Wang W,Guo Z,Yang J,Zhang Y,Durand LG,Loew M

    更新日期:2001-11-01 00:00:00

  • Hip implant performance prediction by acoustic emission techniques: a review.

    abstract::Nowadays, acoustic emission (AE) has its applications in various areas, including mechanical, civil, underwater acoustics, and biomedical engineering. It is a non-destructive evaluation (NDE) and a non-intrusive method to detect active damage mechanisms such as crack growth, delamination, and processes such as frictio...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-020-02202-z

    authors: Remya AR,Vishwash B,Lee C,Pai PS,Espinoza Oras AA,Ozevin D,Mathew MT

    更新日期:2020-08-01 00:00:00

  • Subject-specific finite element analysis of a lumbar cage produced by electron beam melting.

    abstract::The aim of this study was the analysis of the mechanical behaviour of a partially porous lumbar custom-made cage by means of a subject-specific finite element analysis (FEA). The cage, made of Ti6Al4V ELI alloy, was produced via electron beam melting (EBM) process and surgically implanted in a female subject, 50 years...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02078-8

    authors: Epasto G,Distefano F,Mineo R,Guglielmino E

    更新日期:2019-12-01 00:00:00

  • Estimation of respiratory volumes from the photoplethysmographic signal. Part I: Experimental results.

    abstract::To evaluate the possibility of respiratory-volume measurement using photoplethysmography (PPG), PPG signals from 16 normal volunteers are collected, and the respiratory-induced intensity variations (RIIV) are digitally extracted. The RIIV signals are studied while respiratory volume is varied. Furthermore, respiratory...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513264

    authors: Johansson A,Oberg PA

    更新日期:1999-01-01 00:00:00

  • Dynamic cerebral autoregulation: different signal processing methods without influence on results and reproducibility.

    abstract::Cerebral autoregulation controls cerebral blood flow under changing cerebral perfusion pressure. Standards for measurement and analysis of dynamic cerebral autoregulation (dCA) are lacking. In this study, dCA reproducibility, quantified by intraclass correlation coefficient, is evaluated for different methodological a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0706-y

    authors: Gommer ED,Shijaku E,Mess WH,Reulen JP

    更新日期:2010-12-01 00:00:00

  • Reexamination of risk criteria in dengue patients using the self-organizing map.

    abstract::Even though the World Health Organization criteria's for classifying the dengue infection have been used for long time, recent studies declare that several difficulties have been faced by the clinicians to apply these criteria. Accordingly, many studies have proposed modified criteria to identify the risk in dengue pa...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0561-x

    authors: Faisal T,Taib MN,Ibrahim F

    更新日期:2010-03-01 00:00:00

  • Inhibition of TNF-alpha induced cell death in human umbilical vein endothelial cells and Jurkat cells by protocatechuic acid.

    abstract::The Chinese herb radix Salviae miltiorrhizae (RSM) is used in traditional Chinese medicine as a treatment for cardiovascular and cerebrovascular diseases. Several components of the plant extract from salvia mitorrhiza bunge have been determined previously, one of which is protocatechuic acid (PAC). It has been found, ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345308

    authors: Zhou-Stache J,Buettner R,Artmann G,Mittermayer C,Bosserhoff AK

    更新日期:2002-11-01 00:00:00

  • Modelling and multi-parametric control for delivery of anaesthetic agents.

    abstract::This article presents model predictive controllers (MPCs) and multi-parametric model-based controllers for delivery of anaesthetic agents. The MPC can take into account constraints on drug delivery rates and state of the patient but requires solving an optimization problem at regular time intervals. The multi-parametr...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0604-3

    authors: Dua P,Dua V,Pistikopoulos EN

    更新日期:2010-06-01 00:00:00

  • Investigating body motion patterns in patients with Parkinson's disease using matching pursuit algorithm.

    abstract::Several recent studies have quantified abnormalities in Parkinsonian gait. However, few studies have attempted to quantify the regularity of body motion during walking in patients with Parkinson's disease. The aim of the paper was to characterise body motion patterns in healthy, elderly subjects and patients with Park...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02351008

    authors: Sekine M,Akay M,Tamura T,Higashi Y,Fujimoto T

    更新日期:2004-01-01 00:00:00

  • Non-contact diagnostic system for sleep apnea-hypopnea syndrome based on amplitude and phase analysis of thoracic and abdominal Doppler radars.

    abstract::Full-night polysomnography (PSG) has been recognized as the gold standard test for sleep apnea-hypopnea syndrome (SAHS). However, PSG examinees are physically restrained for the full night by many contact sensors and obtrusive connecting cables, inducing mental stress. We developed a non-contact SAHS diagnostic system...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1370-z

    authors: Kagawa M,Tojima H,Matsui T

    更新日期:2016-05-01 00:00:00

  • Analysis of four methods of measuring three-dimensional pelvic tilt in the lateral decubitus position.

    abstract::Proper alignment of acetabular implantation is necessary for good patient outcomes and preventing complications or additional surgeries in total hip arthroplasty (THA). Rotation of the pelvis in lateral decubitus (LD) is typically not accounted for as surgeons use the surgery table as a reference plane to align implan...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02235-4

    authors: Stadnyk M,Liu T,Arezodar FF,Westover L,Carvajal Alba JA,Masson E,Beaupre L,Jaremko JL,El-Rich M

    更新日期:2020-10-01 00:00:00

  • A unified treatment of the reference estimation problem in depth EEG recordings.

    abstract::The starting point of this paper is the analysis of the reference problem in intra-cerebral electroencephalographic (iEEG) recordings. It is well accepted that both surface and depth EEG signals are always recorded with respect to some unknown time-varying signal called reference. This article discusses different meth...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0946-0

    authors: Madhu N,Ranta R,Maillard L,Koessler L

    更新日期:2012-10-01 00:00:00

  • A comparison of two Hilbert spectral analyses of heart rate variability.

    abstract::The present paper compares the performance of two Hilbert spectral analyses when applied to a synthetic RR series from a nonstationary integral pulse frequency modulation model and to real RR series from a dataset of normal sinus arrhythmia. The Hilbert-Huang transformation based on empirical mode decomposition is com...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0500-x

    authors: Ihlen EA

    更新日期:2009-10-01 00:00:00

  • Prediction of O-glycosylation sites based on multi-scale composition of amino acids and feature selection.

    abstract::Protein glycosylation is one of the most important and complex post-translational modification that provides greater proteomic diversity than any other post-translational modification. Fast and reliable computational methods to identify glycosylation sites are in great demand. Two key issues, feature encoding and feat...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1268-9

    authors: Chen Y,Zhou W,Wang H,Yuan Z

    更新日期:2015-06-01 00:00:00

  • New method using multi-regression analysis on evoked electromyography during movement to adjust stimulation conditions.

    abstract::A new method of stimulation of the lower extremities was devised that automatically adjusts the stimulation conditions at any angle of the knee joint. An M-wave is considered to indicate the stimulation conditions, because it is the waveform that results from direct stimulation to the axon of the alpha motor neuron. T...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02351018

    authors: Tanabe S,Muraoka Y,Tomita Y

    更新日期:2004-01-01 00:00:00

  • Theoretical study of the effect of local flow disturbances on the concentration of low-density lipoproteins at the luminal surface of end-to-end anastomosed vessels.

    abstract::To elucidate the mechanisms of localisation of intimal hyperplasia in anastomosed arteries, the effects of flow disturbances on the transport of low-density lipoproteins (LDLs) from the flowing blood to the wall of end-to-end anastomosed arteries, with and without a moderate stenosis, were studied theoretically by mea...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345458

    authors: Wada S,Koujiya M,Karino T

    更新日期:2002-09-01 00:00:00

  • Internal work estimation in three-dimensional gait analysis.

    abstract::Many studies concerning the internal work of human motion have used two-dimensional kinematic models to estimate kinetic energy of the segments. The generalised co-ordinate concept has been applied here to a simultaneous and bilateral gait analysis. A three-dimensional kinematic model based on quaternions has been dev...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02523852

    authors: Aissaoui R,Allard P,Junqua A,Frossard L,Duhaime M

    更新日期:1996-11-01 00:00:00

  • Spectral moments of mechanomyographic signals recorded with accelerometer and microphone during sustained fatiguing contractions.

    abstract::The aim of this study was to analyse the trends of the first three power spectral moments of the mechanomyogram (MMG) signal recorded by a microphone (MMG(MIC)) and an accelerometer (MMG(ACC)) during sustained contractions. MMG signals were recorded from the biceps brachii muscle in 14 healthy male subjects during a 3...

    journal_title:Medical & biological engineering & computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/s11517-006-0036-2

    authors: Madeleine P,Ge HY,Jaskólska A,Farina D,Jaskólski A,Arendt-Nielsen L

    更新日期:2006-04-01 00:00:00

  • Improved photomultiplier tube for positron emission tomography.

    abstract::The paper describes an investigation in which it is shown that small positive voltage pulses applied to an external conductor placed against the photocathode of a photomultiplier tube can be used to switch the photocathode completely off for the duration of the pulses. This suggests that a photomultiplier tube with a ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441486

    authors: Woldeselassie T

    更新日期:1989-05-01 00:00:00

  • 3D micro-computed tomography of trabecular and cortical bone architecture with application to a rat model of immobilisation osteoporosis.

    abstract::Bone mass and microarchitecture are the main determinants of bone strength. Three-dimensional micro-computed tomography has the potential to examine complete bones of small laboratory animals with very high resolution in a non-invasive way. In the presented work, the proximal part of the tibiae of hindlimb unloaded an...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02347054

    authors: Laib A,Barou O,Vico L,Lafage-Proust MH,Alexandre C,Rügsegger P

    更新日期:2000-05-01 00:00:00