Abstract:
:To evaluate the possibility of respiratory-volume measurement using photoplethysmography (PPG), PPG signals from 16 normal volunteers are collected, and the respiratory-induced intensity variations (RIIV) are digitally extracted. The RIIV signals are studied while respiratory volume is varied. Furthermore, respiratory rate, body posture and type of respiration are varied. A Fleisch pneumotachograph is used as the inspired volume reference. The RIIV and pneumotachograph signals are compared, and a statistical analysis is performed (linear regression and t-tests). The key idea is that the amplitude of the RIIV signal is related to the respiratory volume. The conclusion from the measurements is that there exists a relationship between the amplitude of the RIIV signal and the respiratory volume (R = 0.842, s = 0.428, p < 0.005). Absolute measurements of the respiratory volume are not possible from the RIIV signal with the present set-up. The RIIV signal also seems to be affected by respiratory rate and type. More knowledge about respiratory parameters and improved sensor and filter design are required to make absolute measurements of volumes possible.
journal_name
Med Biol Eng Computjournal_title
Medical & biological engineering & computingauthors
Johansson A,Oberg PAdoi
10.1007/BF02513264keywords:
subject
Has Abstractpub_date
1999-01-01 00:00:00pages
42-7issue
1eissn
0140-0118issn
1741-0444journal_volume
37pub_type
杂志文章abstract::A compression algorithm for electrocardiogram signals is presented, based on an auto-associative neural network. Issues of weight and activation coding are considered, and compression performances of various network sizes are compared. A unique feature is the performance improvement achieved using DC level removal. A ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02523019
更新日期:1995-11-01 00:00:00
abstract::A thin-walled capsule, modelled as an incompressible liquid droplet contained in a thin flexible membrane, was allowed to adhere onto a rigid substrate. The contact mechanics were formulated, based on linear elasticity, to portray quantitatively the relationships between osmotic inflation, contact area and angle, memb...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345154
更新日期:2001-09-01 00:00:00
abstract::Impedance cardiography is a low-cost noninvasive technique, based on monitoring of the thoracic impedance, for estimation of stroke volume (SV). Impedance cardiogram (ICG) is the negative of the first derivative of the impedance signal. A technique for beat-to-beat SV estimation using impedance cardiography and artifi...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-017-1752-5
更新日期:2018-06-01 00:00:00
abstract::Self-generated mobility is a major contributor to the physical, emotional, cognitive, and social development of infants and toddlers. When young children have disorders that hinder self locomotion, their development is at risk for delay. Independent mobility via traditional power mobility devices may prevent this dela...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-011-0820-5
更新日期:2011-10-01 00:00:00
abstract::Determination of the adequacy of dialysis is a routine but crucial procedure in patient evaluation. The total dialysis dose, expressed as Kt/V, has been widely recognised to be a major determinant of morbidity and mortality in haemodialysed patients. Many different factors influence the correct determination of Kt/V, ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02348080
更新日期:2003-07-01 00:00:00
abstract::The aim of this study was to develop a radiation-free method to measure gastric emptying. Such a method would be useful e.g. for patients who need repeated measurements and in pregnancy. Ferrimagnetic particles (gamma-Fe2O3), ingested within a solid test meal (pancakes), were magnetised by an applied magnetic field. A...
journal_title:Medical & biological engineering & computing
pub_type: 临床试验,杂志文章
doi:10.1007/BF02522849
更新日期:1998-01-01 00:00:00
abstract::Trabecular bone has a complicated porous microstructure and consists of interconnected plates and rods known as trabeculae. The microarchitecture of the trabeculae contributes to load distribution capacity and, particularly, the optimal bone strength. Many previous studies have shown that morphological parameters are ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-0951-3
更新日期:2012-10-01 00:00:00
abstract::There is a lack of information regarding the forces required for suturing human wounds. The knowledge of suturing forces serves as complementary information for setting up the limiting geometry when using tissue adhesives and it might also be used in robot-assisted surgery. The main purpose of this paper was to evalua...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-011-0857-5
更新日期:2012-02-01 00:00:00
abstract::Leukaemia is a type of blood cancer which mainly occurs when bone marrow produces excess white blood cells in our body. This disease not only affects adult but also is a common cancer type among children. Treatment of leukaemia depends on its type and how far the disease has spread in the body. Leukaemia is classified...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-020-02282-x
更新日期:2020-12-01 00:00:00
abstract::Spinal pattern generators (SPGs), which are neural networks without a central input from the brain may be responsible for controlling locomotion. In this study, we used neural oscillators to examine the rhythmic patterns generated at the ankle during walking. Seven healthy male subjects were requested to walk at their...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-0944-2
更新日期:2012-09-01 00:00:00
abstract::The lactate threshold is used by athletes to optimise the intensity during exercise. It is of interest to measure the threshold on the very day and during the present sport activity. Steady state ergometer tests have been performed on 40 individuals to compare the threshold found by an electro acoustic sensor system t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-008-0373-4
更新日期:2008-09-01 00:00:00
abstract::In electrocardiographic imaging (ECGI), one solves the inverse problem of electrocardiography (ECG) to reconstruct equivalent cardiac sources based on the body surface potential measurements and a mathematical model of the torso. Due to attenuation and spatial smoothing within the torso, this inverse problem is ill-po...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02018-6
更新日期:2019-10-01 00:00:00
abstract::Breast cancer is the most common cancer among women globally, and the number of young women diagnosed with this disease is gradually increasing over the years. Mammography is the current gold-standard technique although it is known to be less sensitive in detecting tumors in woman with dense breast tissue. Detecting a...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1403-7
更新日期:2016-09-01 00:00:00
abstract::In daily life, a person's gait-an important marker for his/her health status-is usually assessed using inertial sensors fixed to lower limbs or trunk. Such sensor locations are not well suited for continuous and long duration measurements. A better location would be the wrist but with the drawback of the presence of p...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-017-1621-2
更新日期:2017-10-01 00:00:00
abstract::Smoothing and differentiation of noisy signals are common problems whenever it is difficult or impossible to obtain derivatives by direct measurement. In biomechanics body displacements are frequently assessed and these measurements are affected by noise. To avoid high-frequency noise magnification, data filtering bef...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02441963
更新日期:1990-09-01 00:00:00
abstract::Results of self-consistent analyses of cells show the possibility of temperature increases at membranes in response to a single nanosecond, high-voltage pulse, at least over small sections of the membrane. Molecular Dynamics simulations indicate that such a temperature increase could facilitate poration, which is one ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-011-0745-z
更新日期:2011-06-01 00:00:00
abstract::We introduce a novel method for an automatic classification of subjects to those with or without neuromuscular disorders. This method is based on multiscale entropy of recorded surface electromyograms (sEMGs) and support vector classification. The method was evaluated on a single-channel experimental sEMGs recorded fr...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-010-0629-7
更新日期:2010-08-01 00:00:00
abstract::Apoptosis proteins are related to many diseases. Obtaining the subcellular localization information of apoptosis proteins is helpful to understand the mechanism of diseases and to develop new drugs. At present, the researchers mainly focus on the primary protein sequences, so there is still room for improvement in the...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02045-3
更新日期:2019-12-01 00:00:00
abstract::The role of alveolar macrophages in the process of the human lung clearance is summarised. Three patterns of alveolar macrophage (AM) displacement on the surface of alveolus are distinguished depending on the loading of the surface with insoluble deposits, i.e. directional, directional with small stochastic noise and ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02522517
更新日期:1995-07-01 00:00:00
abstract::Obstructive sleep apnea syndrome (OSAS) is a major public health problem. The golden reference for diagnosing OSAS is the sleep-laboratory based polysomnography (PSG). However, screening of population for OSAS may be practical and cost efficient only through ambulatory home recordings. In this work we aimed to design,...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-008-0418-8
更新日期:2009-01-01 00:00:00
abstract::The magnitude, mismatch and temporal variations of the electrode-gel-skin interface impedance can cause problems in electrical impedance tomography (EIT) measurement. It is shown that at the high frequencies generally encountered in EIT the capacitive properties of the electrode interface, and especially those of the ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/BF02523842
更新日期:1996-11-01 00:00:00
abstract::A system, to collect, analyse and display biological data, is developed using IBM PC AT compatibles (PCs) or CED1401/1609 devices networked to a VAX environment. It can be operated in three separate modes: using the CED/IEEE/VAX network; using the PC/Ethernet/VAX network; as a standalone PC. The original system compri...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02446881
更新日期:1993-01-01 00:00:00
abstract::This article presents a novel approach of edged and edgeless object-shape recognition and 3D reconstruction from gradient-based analysis of tactile images. We recognize an object's shape by visualizing a surface topology in our mind while grasping the object in our palm and also taking help from our past experience of...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-014-1142-1
更新日期:2014-04-01 00:00:00
abstract::The flow mechanisms that play a role on aerosol deposition were identified and presented in a companion paper (Timothy et al. in Med Biol Eng Comput. doi: 10.1007/s11517-015-1407-3 , 2015). In the current paper, the effects of invasive conventional mechanical ventilation waveforms and endotracheal tube (ETT) on the ae...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1408-2
更新日期:2016-07-01 00:00:00
abstract::Tissue surface temperature distribution on the treatment site can serve as an indicator for the effectiveness of a photothermal therapy. In this study, both infrared thermography and theoretical simulation were used to determine the surface temperature distribution during laser irradiation of both gel phantom and anim...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-007-0251-5
更新日期:2008-02-01 00:00:00
abstract::A three-layer Newtonian model is investigated using a combined Eulerian-Lagrangian computational method to describe the dynamic behaviour of leukocytes. The model, composed of a cell membrane (outer layer), cytoplasm (middle layer) and nucleus (inner layer), can better describe the recovery characteristics because lar...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02510753
更新日期:1998-03-01 00:00:00
abstract::The aim of the study was to assess the wavelength dependence of the UV absorbance during monitoring of different compounds in the dialysate. UV absorbance was determined by using a double-beam spectrophotometer on dialysate samples taken at pre-determined times during dialysis, over a wavelength range of 180-380 nm. C...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02348430
更新日期:2003-05-01 00:00:00
abstract::Modern pacemakers (implantable devices used for maintaining an appropriate heart rate in patients) can use an intracardiac ventricular impedance signal for physiological cardiac stimulation control. Intracardiac ventricular impedance from nine animal subjects is analysed and presented (seven sheep: 49.0 +/- 6.5 kg, si...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345448
更新日期:2002-09-01 00:00:00
abstract::The complexity of the monitored data available in modern intensive care units suggests that they may be best processed, for presentation to medical staff, by expert system techniques. However, standard expert system shells are ill-fitted to either the basic sequential monitoring tasks of data acquisition and storage, ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02525536
更新日期:1997-09-01 00:00:00
abstract::Pain control in conscious patients was investigated using a push-button, demand-driven supply of drugs. A fuzzy logic patient-controlled analgesia (PCA) algorithm was compared with a conventional algorithm, for alfentanil administration in extracorporeal shock-wave lithotripsy. The conventional PCA algorithm used an i...
journal_title:Medical & biological engineering & computing
pub_type: 临床试验,杂志文章
doi:10.1007/BF02347706
更新日期:2002-01-01 00:00:00