Extraction of Cole parameters from the electrical bioimpedance spectrum using stochastic optimization algorithms.

Abstract:

:Fitting the measured bioimpedance spectroscopy (BIS) data to the Cole model and then extracting the Cole parameters is a common practice in BIS applications. The extracted Cole parameters then can be analysed as descriptors of tissue electrical properties. To have a better evaluation of physiological or pathological properties of biological tissue, accurate extraction of Cole parameters is of great importance. This paper proposes an improved Cole parameter extraction based on bacterial foraging optimization (BFO) algorithm. We employed simulated datasets to test the performance of the BFO fitting method regarding parameter extraction accuracy and noise sensitivity, and we compared the results with those of a least squares (LS) fitting method. The BFO method showed better robustness to the noise and higher accuracy in terms of extracted parameters. In addition, we applied our method to experimental data where bioimpedance measurements were obtained from forearm in three different positions of the arm. The goal of the experiment was to explore how robust Cole parameters are in classifying position of the arm for different people, and measured at different times. The extracted Cole parameters obtained by LS and BFO methods were applied to different classifiers. Two other evolutionary algorithms, GA and PSO were also used for comparison purpose. We showed that when the classifiers are fed with the extracted feature sets by BFO fitting method, higher accuracy is obtained both when applying on training data and test data.

journal_name

Med Biol Eng Comput

authors

Gholami-Boroujeny S,Bolic M

doi

10.1007/s11517-015-1355-y

subject

Has Abstract

pub_date

2016-04-01 00:00:00

pages

643-51

issue

4

eissn

0140-0118

issn

1741-0444

pii

10.1007/s11517-015-1355-y

journal_volume

54

pub_type

杂志文章
  • Development of a non-invasive treatment system for urinary incontinence using a functional continuous magnetic stimulator (FCMS).

    abstract::A system composed of a functional continuous magnetic stimulator (FCMS) and a saddle-type coil has been developed for non-invasive treatment of urinary incontinence, especially stress incontinence and urge incontinence. The FCMS conditions were as follows: 2 kW maximum electrical power consumption, 800 V maximum capac...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02518872

    authors: Ishikawa N,Suda S,Sasaki T,Yamanishi T,Hosaka H,Yasuda K,Ito H

    更新日期:1998-11-01 00:00:00

  • Corrected formula for estimating peripheral blood flow by impedance plethysmography.

    abstract::In this paper, the limitations of the conventional formula for the computation of peripheral blood flow from impedance plethysmograms are highlighted, and a correction to the formula is suggested. A conductivity cell experiment is described to show the dependence of the value of the blood flow index (BFI), obtained fr...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02524237

    authors: Jindal GD,Nerurkar SN,Pednekar SA,Babu JP,Bhuta AC,Deshpande AK

    更新日期:1994-11-01 00:00:00

  • Modelling and multi-parametric control for delivery of anaesthetic agents.

    abstract::This article presents model predictive controllers (MPCs) and multi-parametric model-based controllers for delivery of anaesthetic agents. The MPC can take into account constraints on drug delivery rates and state of the patient but requires solving an optimization problem at regular time intervals. The multi-parametr...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0604-3

    authors: Dua P,Dua V,Pistikopoulos EN

    更新日期:2010-06-01 00:00:00

  • Classifying changes in LN-18 glial cell morphology: a supervised machine learning approach to analyzing cell microscopy data via FIJI and WEKA.

    abstract::In cell-based research, the process of visually monitoring cells generates large image datasets that need to be evaluated for quantifiable information in order to track the effectiveness of treatments in vitro. With the traditional, end-point assay-based approach being error-prone, and existing computational approache...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02177-x

    authors: Mbiki S,McClendon J,Alexander-Bryant A,Gilmore J

    更新日期:2020-07-01 00:00:00

  • Using three-dimensional multigrid-based snake and multiresolution image registration for reconstruction of cranial defect.

    abstract::In cranioplasty, neurosurgeons use bone grafts to repair skull defects. To ensure the protection of intracranial tissues and recover the original head shape for aesthetic purposes, a custom-made pre-fabricated prosthesis must match the cranial incision as closely as possible. In our previous study (Liao et al. in Med ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0972-y

    authors: Liao YL,Lu CF,Wu CT,Lee JD,Lee ST,Sun YN,Wu YT

    更新日期:2013-02-01 00:00:00

  • A new combination: scale-space filtering of projected brain activities.

    abstract::In the present study, well known scale-space filtering (SSF) algorithm is used in combination with a linear mapping approach (LMA) to obtain clear auditory evoked potential (EP) waveform. The proposed combination involves two sequential steps: At first, the EEG noise level is reduced from -5 to 0 dB owing to the LMA b...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0450-3

    authors: Aydin S

    更新日期:2009-04-01 00:00:00

  • Estimation of habituation and signal-to-noise ratio of cortical evoked potentials to oesophageal electrical and mechanical stimulation.

    abstract::Electrical and mechanical stimulation of the oesophagus has been recently proposed to examine the physiological effects of autonomic stimulation in humans. Cortical evoked potentials (EPs) to oesophageal stimulation provide an assessment of afferent fibres and central processing. However, habituation takes place durin...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02534088

    authors: Kamath MV,Tougas G,Hollerbach S,Premji R,Fitzpatrick D,Shine G,Upton AR

    更新日期:1997-07-01 00:00:00

  • Pressures generated by rib cage and abdominal compressions during cardiopulmonary resuscitation.

    abstract::When the rib cage and abdomen are compressed during cardiopulmonary resuscitation (CPR), the effect on intrathoracic pressure, and therefore on haemodynamics, cannot be quantitatively predicted without a physiologically based mathematical model of chest wall dynamics. Using such a model, we compared model simulations ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441676

    authors: Ben-Haim SA,Shofti R,Dinnar U,Saidel GM

    更新日期:1990-01-01 00:00:00

  • Transient phase locking patterns among respiration, heart rate and blood pressure during cardiorespiratory synchronisation in humans.

    abstract::The interactions between respiration, heart rate and blood pressure variability (HRV, BPV), are considered to be of paramount importance for the study of the functional organisation of the autonomic nervous system (ANS). The aim of the reported study is to detect and classify the intermittent phase locking (PL) phenom...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345011

    authors: Censi F,Calcagnini G,Lino S,Seydnejad SR,Kitney RI,Cerutti S

    更新日期:2000-07-01 00:00:00

  • Feature extraction for on-line EEG classification using principal components and linear discriminants.

    abstract::The study focuses on the problems of dimensionality reduction by means of principal component analysis (PCA) in the context of single-trial EEG data classification (i.e. discriminating between imagined left- and right-hand movement). The principal components with the highest variance, however, do not necessarily carry...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02522476

    authors: Lugger K,Flotzinger D,Schlögl A,Pregenzer M,Pfurtscheller G

    更新日期:1998-05-01 00:00:00

  • Velocity distribution model for normal blood flow in the human ascending aorta.

    abstract::During the study of velocities in the human ascending aorta it became necessary to establish a method for two-dimensional velocity profiles from discrete velocity data obtained from different heartbeats and with different techniques. A descriptive geometrical model was therefore developed and expanded to 16 elements e...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02442319

    authors: Segadal L

    更新日期:1991-09-01 00:00:00

  • Filtered maximum likelihood expectation maximization based global reconstruction for bioluminescence tomography.

    abstract::The reconstruction of bioluminescence tomography (BLT) is severely ill-posed due to the insufficient measurements and diffuses nature of the light propagation. Predefined permissible source region (PSR) combined with regularization terms is one common strategy to reduce such ill-posedness. However, the region of PSR i...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1842-z

    authors: Yang D,Wang L,Chen D,Yan C,He X,Liang J,Chen X

    更新日期:2018-11-01 00:00:00

  • Efficient and robust estimation of blood oxygenation levels in single cerebral veins.

    abstract::Blood oxygenation level is an important measure that can be used alongside functional magnetic resonance imaging data in order to obtain closer correlates of neuronal activation. A robust estimate of this measure has thus far not been demonstrated. This is mainly due to the lack of knowledge of the underlying paramete...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0886-8

    authors: Dagher J,Du YP

    更新日期:2012-05-01 00:00:00

  • Quantitative assessment of lower limbs gross motor function in children with cerebral palsy based on surface EMG and inertial sensors.

    abstract::Taking advantage of motion sensing technology, a quantitative assessment method for lower limbs motor function of cerebral palsy (CP) based on the gross motor function measurement (GMFM)-24 scale was explored in this study. According to the motion analysis on GMFM-24 scale, we translated the assessment problem of GMFM...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02076-w

    authors: Chen X,Wu Q,Tang L,Cao S,Zhang X,Chen X

    更新日期:2020-01-01 00:00:00

  • Arterial reservoir-excess pressure and ventricular work.

    abstract::This study is based on the hypothesis that the pressure within the arterial network can be usefully decomposed as the sum of a reservoir pressure and an excess pressure. The reservoir pressure waveform is defined to be the same in each vessel but delayed by the wave travel time from the root of the aorta. Using calcul...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0872-1

    authors: Parker KH,Alastruey J,Stan GB

    更新日期:2012-04-01 00:00:00

  • Fast GPU-based computation of spatial multigrid multiframe LMEM for PET.

    abstract::Significant efforts were invested during the last decade to accelerate PET list-mode reconstructions, notably with GPU devices. However, the computation time per event is still relatively long, and the list-mode efficiency on the GPU is well below the histogram-mode efficiency. Since list-mode data are not arranged in...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1284-9

    authors: Nassiri MA,Carrier JF,Després P

    更新日期:2015-09-01 00:00:00

  • A computer-assisted human peripheral blood leukocyte image classification method based on Siamese network.

    abstract::A computer-assisted human peripheral blood leukocyte image classification method based on Siamese network is proposed. Firstly, a Siamese network with two identical convolutional neural network (CNN) sub-networks and a logistic regression for leukocyte five classification is designed, which can learn not only distingu...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02180-2

    authors: Wang Y,Cao Y

    更新日期:2020-07-01 00:00:00

  • Development of a comprehensive musculoskeletal model of the shoulder and elbow.

    abstract::The Delft Shoulder and Elbow Model (DSEM), a musculoskeletal model of the shoulder and elbow has been extensively developed since its introduction in 1994. Extensions cover both model structures and anatomical data focusing on the addition of an elbow part and muscle architecture parameters. The model was also extende...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0839-7

    authors: Nikooyan AA,Veeger HE,Chadwick EK,Praagman M,Helm FC

    更新日期:2011-12-01 00:00:00

  • Detection of the third heart sound using a tailored wavelet approach: method verification.

    abstract::Heart sounds can be considered as mechanical fingerprints of myocardial function. The third heart sound normally occurs in children but disappears with maturation. The sound can also appear in patients with heart failure. The sound is characterised by its low-amplitude and low-frequency content, which makes it difficu...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345957

    authors: Hult P,Fjällbrant T,Hildén K,Dahlström U,Wranne B,Ask P

    更新日期:2005-03-01 00:00:00

  • A novel recursive Fourier transform for nonuniform sampled signals: application to heart rate variability spectrum estimation.

    abstract::We present a novel method to iteratively calculate discrete Fourier transforms for discrete time signals with sample time intervals that may be widely nonuniform. The proposed recursive Fourier transform (RFT) does not require interpolation of the samples to uniform time intervals, and each iterative transform update ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0461-0

    authors: Holland A,Aboy M

    更新日期:2009-07-01 00:00:00

  • Computational prediction of the effect of D172N KCNJ2 mutation on ventricular pumping during sinus rhythm and reentry.

    abstract::The understanding of cardiac arrhythmia under genetic mutations has grown in interest among researchers. Previous studies focused on the effect of the D172N mutation on electrophysiological behavior. In this study, we analyzed not only the electrophysiological activity but also the mechanical responses during normal s...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02124-w

    authors: Heikhmakhtiar AK,Lee CH,Song KS,Lim KM

    更新日期:2020-05-01 00:00:00

  • Registration and geometric modelling of the spine during scoliosis surgery: a comparison study of different pre-operative reconstruction techniques and intra-operative tracking systems.

    abstract::During scoliosis instrumentation surgery, it is difficult for surgeons fully to track vertebral motion in 3D, because only the posterior elements of the spine are exposed. Different intra-operative modelling approaches are evaluated using a registration technique that matches intra-operative measurements with a 3D pre...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513328

    authors: Mac-Thiong JM,Aubin CE,Dansereau J,de Guise JA,Brodeur P,Labelle H

    更新日期:1999-07-01 00:00:00

  • Progressive changes of elastic moduli of arterial wall and atherosclerotic plaque components during plaque development in human coronary arteries.

    abstract::Stiffness of the arterial wall and atherosclerotic plaque components is a determinant of the stress field within plaques, which has been suggested to be an indicator of plaque vulnerability. The diversity and inhomogeneous structure of atherosclerotic lesions complicate the characterization of plaque components. In th...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1910-4

    authors: Rezvani-Sharif A,Tafazzoli-Shadpour M,Avolio A

    更新日期:2019-03-01 00:00:00

  • Performance analysis of melanoma classifier using electrical modeling technique.

    abstract::An efficient and novel modeling approach is proposed in this paper for identifying proteins or genes involved in melanoma skin cancer. Two types of classifiers are modeled, based on the chemical structure and hydropathy property of amino acids. These classifiers are further implemented using NI LabVIEW-based hardware ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02241-6

    authors: Roy T,Bhattacharjee P

    更新日期:2020-10-01 00:00:00

  • Development of automatized new indices for radiological assessment of chest-wall deformity and its quantitative evaluation.

    abstract::Pre-operative diagnosis of chest-wall deformity is important for successful surgical correction and post-operative evaluation of funnel chest patients. However, conventional indices that define the severity of deformity have several limitations; manually calculated and cannot supply information about asymmetry. We dev...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0367-2

    authors: Kim HC,Park HJ,Ham SY,Nam KW,Choi SY,Oh JS,Choi H,Jeong GS,Park SW,Kim MG,Sun K

    更新日期:2008-08-01 00:00:00

  • Estimation of mean arterial pressure from the oscillometric cuff pressure: comparison of different techniques.

    abstract::Mean arterial pressure (MAP) is determined in most automated oscillometric blood pressure devices, but its derivation has been little studied. In this research, different techniques were studied and compared with the auscultatory technique. Auscultatory systolic and diastolic blood pressure (SBP and DBP) were obtained...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0694-y

    authors: Zheng D,Amoore JN,Mieke S,Murray A

    更新日期:2011-01-01 00:00:00

  • A mechatronic valve in the management of hydrocephalus: methods and performance.

    abstract::The problem of excess cerebrospinal fluid in the brain (hydrocephalus) is generally managed using a passive pressure or flow regulated mechanical shunt. Despite the success of such devices, they have been plagued with a number of problems. It is desirable to have a shunt valve that responds dynamically to the changing...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0716-9

    authors: Momani L,Al-Nuaimy W,Al-Jumaily M,Mallucci C

    更新日期:2011-01-01 00:00:00

  • Effect of mains interference on time coherent averaging.

    abstract::The paper deals with the influence of mains interference on time coherent averaging using an internal trigger. The general distribution of the time jitter is derived and applied to a simplified signal. The authors prove that no amount of averaging can do away with this type of interference. Finally, the deformation th...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02457827

    authors: Strackee J,Peper A

    更新日期:1992-09-01 00:00:00

  • Improved photomultiplier tube for positron emission tomography.

    abstract::The paper describes an investigation in which it is shown that small positive voltage pulses applied to an external conductor placed against the photocathode of a photomultiplier tube can be used to switch the photocathode completely off for the duration of the pulses. This suggests that a photomultiplier tube with a ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441486

    authors: Woldeselassie T

    更新日期:1989-05-01 00:00:00

  • Decreased global field synchronization of multichannel frontal EEG measurements in obsessive-compulsive disorders.

    abstract::Global field synchronization (GFS) quantifies the synchronization level of brain oscillations. The GFS method has been introduced to measure functional synchronization of EEG data in the frequency domain. GFS also detects phase interactions between EEG signals acquired from all of the electrodes. If a considerable amo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1689-8

    authors: Özçoban MA,Tan O,Aydin S,Akan A

    更新日期:2018-02-01 00:00:00