Abstract:
:The problem of excess cerebrospinal fluid in the brain (hydrocephalus) is generally managed using a passive pressure or flow regulated mechanical shunt. Despite the success of such devices, they have been plagued with a number of problems. It is desirable to have a shunt valve that responds dynamically to the changing needs of the patient, opening and closing according to a dynamic physiological pattern, rather than simply to the hydrostatic pressure across the valve. Such a valve would by necessity be mechatronic, electronically controlled by software. In this article, different methods for controlling such a mechatronic valve are explored, and the effect of current hydrocephalus management techniques on the intracranial hydrodynamics of acute hydrocephalus patient compared with those based on a mechatronic valve was investigated using numerical simulation. Furthermore, the performance of these techniques was evaluated based on a proposed multi-dimensional figure of merit. In addition, an empirical valve schedule was proposed based on different criterions. An intelligent shunting system is seen as the future in hydrocephalus management and treatment, and towards this end, suitably programmed mechatronic valves would attempt to mimic normal physiology and potentially overcome many of the problems associated with current mechanical valves.
journal_name
Med Biol Eng Computjournal_title
Medical & biological engineering & computingauthors
Momani L,Al-Nuaimy W,Al-Jumaily M,Mallucci Cdoi
10.1007/s11517-010-0716-9subject
Has Abstractpub_date
2011-01-01 00:00:00pages
121-32issue
1eissn
0140-0118issn
1741-0444journal_volume
49pub_type
杂志文章abstract::Four ventricular fibrillation (VF) detection techniques were assessed using recordings of VF to evaluate sensitivity and VF-like recordings to evaluate specificity. The recordings were obtained from Coronary Care Unit patients. The techniques were: threshold crossing intervals (TCI); peaks in the autocorrelation funct...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02446668
更新日期:1993-03-01 00:00:00
abstract::Electrocardiogram (ECG)-triggered laser Doppler perfusion monitoring (LDPM) was used to assess myocardial perfusion, with minimum myocardial tissue motion influence, during coronary artery bypass grafting (CABG). Thirteen subjects were investigated at six phases: pre- and post-CABG; post aorta cross-clamping; pre and ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02351031
更新日期:2005-09-01 00:00:00
abstract::Remote patient monitoring should reduce mortality rates, improve care, and reduce costs. We present an overview of the available technologies for the remote monitoring of chronic obstructive pulmonary disease (COPD) patients, together with the most important medical information regarding COPD in a language that is ada...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-018-1798-z
更新日期:2018-04-01 00:00:00
abstract::Osteoporosis is one of the most common diseases that leads to bone fractures. Dual-energy X-ray absorptiometry is currently employed to measure the bone mineral density and to diagnose osteoporosis. Alternatively, the dielectric properties of bones are found to be influenced by bone mineral density; hence, dielectric ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-018-1887-z
更新日期:2019-01-01 00:00:00
abstract::We estimated the dynamic cell metabolic activity and the distribution of the pH value and oxygen concentration in tissue samples cultured in vitro by using real-time sensor records and a numerical simulation of the underlying reaction-diffusion processes. As an experimental tissue model, we used chicken spleen slices....
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1367-7
更新日期:2016-05-01 00:00:00
abstract::An algorithm for determining the frequency and propagation time of the gastric slow wave has been designed for integration into a demand gastric pacing system. The algorithm analyses the serosal activity in both the time and frequency domains, and the results are compared to produce a conclusion only when the values a...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344688
更新日期:2000-01-01 00:00:00
abstract::A new method of stimulation of the lower extremities was devised that automatically adjusts the stimulation conditions at any angle of the knee joint. An M-wave is considered to indicate the stimulation conditions, because it is the waveform that results from direct stimulation to the axon of the alpha motor neuron. T...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02351018
更新日期:2004-01-01 00:00:00
abstract::The aim of this study was to investigate conventionally and early loaded titanium and titanium-zirconium alloy implants by three-dimensional finite element stress analysis. Three-dimensional model of a dental implant was created and a thread area was established as a region of interest in trabecular bone to study a lo...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1256-0
更新日期:2015-05-01 00:00:00
abstract::Spectral analysis of heart rate variability (HRV) is a widely accepted approach for assessment of cardiac autonomic function and its relationship to numerous disorders and diseases. As a rule, the non-parametric methods for HRV spectral analysis are tested using the integral pulse frequency modulation (IPFM) model. Ho...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345290
更新日期:2001-05-01 00:00:00
abstract::In this study, we present finite element analysis models to calculate the increase in intrathoracic volume of pectus excavatum patients after the Nuss procedure. One virtue of our approach is that the measurement of the intrathoracic volume has no time difference and is not affected by postoperative pain, which cannot...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0570-9
更新日期:2010-02-01 00:00:00
abstract::Pain control in conscious patients was investigated using a push-button, demand-driven supply of drugs. A fuzzy logic patient-controlled analgesia (PCA) algorithm was compared with a conventional algorithm, for alfentanil administration in extracorporeal shock-wave lithotripsy. The conventional PCA algorithm used an i...
journal_title:Medical & biological engineering & computing
pub_type: 临床试验,杂志文章
doi:10.1007/BF02347706
更新日期:2002-01-01 00:00:00
abstract::The flow mechanisms that play a role on aerosol deposition were identified and presented in a companion paper (Timothy et al. in Med Biol Eng Comput. doi: 10.1007/s11517-015-1407-3 , 2015). In the current paper, the effects of invasive conventional mechanical ventilation waveforms and endotracheal tube (ETT) on the ae...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1408-2
更新日期:2016-07-01 00:00:00
abstract::The aim of the study was to investigate the effect of signal length on the performance of a signal source separation method, independent component analysis (ICA), when extracting the visual evoked potential (EP) lambda wave from saccade-related electro-encephalogram (EEG) waveforms. A method was devised that enabled t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02348134
更新日期:2002-03-01 00:00:00
abstract::In cranioplasty, neurosurgeons use bone grafts to repair skull defects. To ensure the protection of intracranial tissues and recover the original head shape for aesthetic purposes, a custom-made pre-fabricated prosthesis must match the cranial incision as closely as possible. In our previous study (Liao et al. in Med ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-0972-y
更新日期:2013-02-01 00:00:00
abstract::The Chinese herb radix Salviae miltiorrhizae (RSM) is used in traditional Chinese medicine as a treatment for cardiovascular and cerebrovascular diseases. Several components of the plant extract from salvia mitorrhiza bunge have been determined previously, one of which is protocatechuic acid (PAC). It has been found, ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345308
更新日期:2002-11-01 00:00:00
abstract::A method for extrapolating the extracellular water (ECW) resistance from wrist-ankle resistance at 50 kHz (R (50)) is proposed in this paper, in order to enable 50 kHz impedancemeters to use the BIS-Hanai equation for determination of ECW. Values of R (50) and the ECW resistance extrapolated at zero frequency R (e) we...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-008-0394-z
更新日期:2009-01-01 00:00:00
abstract::In total hip arthroplasty, determining the impingement free range of motion requirement is a complex task. This is because in the native hip, motion is restricted by both impingement as well as soft tissue restraint. The aim of this study is to determine a range of motion benchmark which can identify motions which are...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-1016-3
更新日期:2013-04-01 00:00:00
abstract::The propagation of waves in the arteries is generally described using Fourier analysis in terms of periodic wavetrains formed by the superposition of a mean value and sinusoidal waves at the fundamental frequency (defined by the heart rate) and its harmonics. There is, however, an alternative way to describe waves in ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-008-0403-2
更新日期:2009-02-01 00:00:00
abstract::High-frequency nanosecond-pulsed electric fields were recently introduced for tumor or abnormal tissue ablation to solve some problems of conventional electroporation. However, it is necessary to study the thermal effects of high-field-intensity nanosecond pulses inside tissues. The multi-parametric analysis performed...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-016-1589-3
更新日期:2017-07-01 00:00:00
abstract::The study and applications of in vivo skin optics have been openly documented as early as the year 1954, or possibly earlier. To date, challenges in analyzing the complexities of this field remain, with wide scopes requiring more scrutiny. Recent advances in spectroscopic research and multivariate analytics allow a cl...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-019-02077-9
更新日期:2020-06-01 00:00:00
abstract::A method for the identification of the breast boundary in mammograms is presented. The method can be used in the preprocessing stage of a system for computer-aided diagnosis (CAD) of breast cancer and also in the reduction of image file size in picture archiving and communication system applications. The method starte...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344632
更新日期:2004-03-01 00:00:00
abstract::Global field synchronization (GFS) quantifies the synchronization level of brain oscillations. The GFS method has been introduced to measure functional synchronization of EEG data in the frequency domain. GFS also detects phase interactions between EEG signals acquired from all of the electrodes. If a considerable amo...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-017-1689-8
更新日期:2018-02-01 00:00:00
abstract::In this study, we introduce a novel simulation technique to incorporate delineation errors into radiotherapy treatment margins and combine them with organ motion and set-up errors to investigate the cumulative dosimetric effects in different tumour sites. The effects of applying patient realignment correction protocol...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-010-0616-z
更新日期:2010-07-01 00:00:00
abstract::A mathematical model has been developed to facilitate indirect measurements of difficult to measure variables of the human energy metabolism on a daily basis. The model performs recursive system identification of the parameters of the metabolic model of the human energy metabolism using the law of conservation of ener...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-016-1552-3
更新日期:2017-05-01 00:00:00
abstract::A system composed of a functional continuous magnetic stimulator (FCMS) and a saddle-type coil has been developed for non-invasive treatment of urinary incontinence, especially stress incontinence and urge incontinence. The FCMS conditions were as follows: 2 kW maximum electrical power consumption, 800 V maximum capac...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02518872
更新日期:1998-11-01 00:00:00
abstract::The relation is investigated between stimulus frequency, stimulus pulse amplitude and the neural damage induced by continuous stimulation of the cat's sciatic nerve. The chronically implanted electrodes were pulsed continuously and the effects of the electrical stimulation were quantified as the amount of early axonal...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02510526
更新日期:1995-05-01 00:00:00
abstract::The physiological parameters of blood such as extracellular Na(+), K(+), Cl(-), pH, 2,3-DPG and ATP and the complex electrical impedance were measured using whole blood samples from 31 male donors (21 donors form the training set and ten donors were used for testing), on the 0th, 10th and 21st day of blood bank storag...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-007-0206-x
更新日期:2007-07-01 00:00:00
abstract::Deep brain stimulation (DBS) surgery is extensively used in the treatment of movement disorders. Nevertheless, methods to evaluate the clinical response during intraoperative stimulation tests to identify the optimal position for the implantation of the chronic DBS lead remain subjective. In this paper, we describe a ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-016-1559-9
更新日期:2017-05-01 00:00:00
abstract::An eye pointer was developed as a new line-of-sight displacement analyser. It analyses an observer's eye movements and superimposes their line of vision on a TV image which is the same as their view. A newly developed miniature colour field camera and very compact eye-movement sensors are attached to a translucent rei...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02446149
更新日期:1990-07-01 00:00:00
abstract::A novel laser Doppler flowmetry scheme is reported that adjusts the processing bandwidth adaptively to optimise the estimation of flow. To obtain an adequate processing bandwidth, the Doppler spectra is first fitted to the Lorentzian function, and the bandwidth at half the maximum of the Lorentzian function is used as...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344700
更新日期:2004-05-01 00:00:00