Myocardial perfusion monitoring during coronary artery bypass using an electrocardiogram-triggered laser Doppler technique.

Abstract:

:Electrocardiogram (ECG)-triggered laser Doppler perfusion monitoring (LDPM) was used to assess myocardial perfusion, with minimum myocardial tissue motion influence, during coronary artery bypass grafting (CABG). Thirteen subjects were investigated at six phases: pre- and post-CABG; post aorta cross-clamping; pre and post left internal mammary artery (LIMA) graft declamping; and post aorta declamping. The perfusion signal was calculated in late systole and late diastole, with expected minimum tissue motion, and compared with arrested heart measurements. Patient conditions or artifacts caused by surgical activity made it impossible to perform and analyse data in all six phases for some patients. No significant (n = 5) difference between perfusion signals pre- and post-CABG was found. Diastolic perfusion signal levels were significantly (p < 0.02) lower compared with systolic levels. After aorta cross-clamping, the signal level was almost zero. A distinct perfusion signal increase after LIMA and aorta declamping, compared with pre-LIMA declamping, was found in ten cases out of 13. A significantly (p < 0.04) lower perfusion signal in the arrested heart compared with in the beating heart was registered. Influence from mechanical ventilation was observed in 14 measurements out of 17. In conclusion, ECG-triggered LDPM can be used to assess myocardial perfusion during CABG. Perfusion signals were lower in the arrested heart compared with in the beating heart and in late diastole compared with late systole. No significant difference between pre- and post-CABG was found.

journal_name

Med Biol Eng Comput

authors

Karlsson MG,Fors C,Wårdell K,Casimir-Ahn H

doi

10.1007/BF02351031

keywords:

subject

Has Abstract

pub_date

2005-09-01 00:00:00

pages

582-8

issue

5

eissn

0140-0118

issn

1741-0444

journal_volume

43

pub_type

杂志文章
  • Clinical application of modified bag-of-features coupled with hybrid neural-based classifier in dengue fever classification using gene expression data.

    abstract::Dengue fever detection and classification have a vital role due to the recent outbreaks of different kinds of dengue fever. Recently, the advancement in the microarray technology can be employed for such classification process. Several studies have established that the gene selection phase takes a significant role in ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1722-y

    authors: Chatterjee S,Dey N,Shi F,Ashour AS,Fong SJ,Sen S

    更新日期:2018-04-01 00:00:00

  • Estimation of the dynamics of event-related desynchronisation changes in electroencephalograms.

    abstract::A method for the estimation of medium rate transitions of non-stationary electroencephalograms (EEG) is proposed. The method is applicable to such EEG dynamics that are between (a) fast transitions for which segmentation procedures are used and (b) slow transitions for which adaptive filters work properly. The estimat...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513305

    authors: Hiltunen JK,Karjalainen PA,Partanen J,Kaipio JP

    更新日期:1999-05-01 00:00:00

  • Effect of the shape and configuration of smooth muscle cells on the diffusion of ATP through the arterial wall.

    abstract::In this study, the shape and the configuration of smooth muscle cells (SMCs) within the arterial wall are altered to investigate their influence on molecular transport across the media layer of the thoracic aorta wall. In a 2D geometry of the media layer containing SMCs, the finite-element method has been employed to ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0219-5

    authors: Dabagh M,Jalali P,Sarkomaa P

    更新日期:2007-11-01 00:00:00

  • Relationship between stimulus amplitude, stimulus frequency and neural damage during electrical stimulation of sciatic nerve of cat.

    abstract::The relation is investigated between stimulus frequency, stimulus pulse amplitude and the neural damage induced by continuous stimulation of the cat's sciatic nerve. The chronically implanted electrodes were pulsed continuously and the effects of the electrical stimulation were quantified as the amount of early axonal...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510526

    authors: McCreery DB,Agnew WF,Yuen TG,Bullara LA

    更新日期:1995-05-01 00:00:00

  • Quantitative analysis of images in erythropoietin doping control.

    abstract::The software system GASepo has been developed as a tool to visualise and analyse doping (searching for performance-enhancing drugs in sports) with recombinant erythropoietin (rEpo). Digital images derived from the separation of Epo isoforms in gels by iso-electric focusing followed by double blotting and chemiluminesc...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345819

    authors: Bajla I,Holländer I,Gmeiner G,Reichel Ch

    更新日期:2005-05-01 00:00:00

  • RETRACTED ARTICLE: Deep convolutional neural network-based speech enhancement to improve speech intelligibility and quality for hearing-impaired listeners.

    abstract:: ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,撤回出版物

    doi:10.1007/s11517-018-1933-x

    authors: Khaleelur Rahiman PF,Jayanthi VS,Jayanthi AN

    更新日期:2019-03-01 00:00:00

  • Pattern recognition approach to the detection of single-trial event-related functional magnetic resonance images.

    abstract::Functional magnetic resonance imaging (FMRI) is an imaging technique for determining which regions of the brain are activated in response to a stimulus or event. Early FMRI experiment paradigms were based upon those used in positron emission tomography (PET), i.e. employing a block design consisting of extended period...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02347541

    authors: Burke D,Murphy K,Garavan H,Reilly R

    更新日期:2004-09-01 00:00:00

  • 3D shape analysis to reduce false positives for lung nodule detection systems.

    abstract::Using images from the Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI), we developed a methodology for classifying lung nodules. The proposed methodology uses image processing and pattern recognition techniques. To classify volumes of interest into nodules and non-nodules, we used shape mea...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1582-x

    authors: Filho AOC,Silva AC,de Paiva AC,Nunes RA,Gattass M

    更新日期:2017-08-01 00:00:00

  • Combined compression and elongation experiments and non-linear modelling of liver tissue for surgical simulation.

    abstract::Uniaxial stress-strain data were obtained from in vitro experiments on 20 porcine livers for compressions, elongations and cycles of compression and then elongation. There were about 70 cylindrical samples, with diameter 7mm and varying height (4-11 mm). The combined compression and elongation test provide a unified f...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345212

    authors: Chui C,Kobayashi E,Chen X,Hisada T,Sakuma I

    更新日期:2004-11-01 00:00:00

  • Structuring of service centres for economic and equipment efficiency.

    abstract::Increasing costs in healthcare have stimulated discussions on whether installation of competent in-house service groups for equipment management could eventually aid in reducing expenditure. In the Federal Republic of Germany, a four-year programme was initiated in 1979 with the purpose of investigating the feasibilit...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02442172

    authors: Irnich W

    更新日期:1989-01-01 00:00:00

  • A simulation technique for computation of the dosimetric effects of setup, organ motion and delineation uncertainties in radiotherapy.

    abstract::In this study, we introduce a novel simulation technique to incorporate delineation errors into radiotherapy treatment margins and combine them with organ motion and set-up errors to investigate the cumulative dosimetric effects in different tumour sites. The effects of applying patient realignment correction protocol...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0616-z

    authors: Mzenda B,Hosseini-Ashrafi M,Palmer A,Liu H,Brown DJ

    更新日期:2010-07-01 00:00:00

  • Image-based state-of-the-art techniques for the identification and classification of brain diseases: a review.

    abstract::Detection and classification methods have a vital and important role in identifying brain diseases. Timely detection and classification of brain diseases enable an accurate identification and effective management of brain impairment. Brain disorders are commonly most spreadable diseases and the diagnosing process is t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-020-02256-z

    authors: Haq EU,Huang J,Kang L,Haq HU,Zhan T

    更新日期:2020-11-01 00:00:00

  • Monopole patch antenna for in vivo exposure to nanosecond pulsed electric fields.

    abstract::To explore the promising therapeutic applications of short nanosecond electric pulses, in vitro and in vivo experiments are highly required. In this paper, an exposure system based on monopole patch antenna is reported to perform in vivo experiments on newborn mice with both monopolar and bipolar nanosecond signals. A...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1547-0

    authors: Merla C,Apollonio F,Paffi A,Marino C,Vernier PT,Liberti M

    更新日期:2017-07-01 00:00:00

  • Refixation stability in shoulder hemiarthroplasty in case of four-part proximal humeral fracture.

    abstract::Primary stability of refixated fractures in case of shoulder hemiarthroplasty is a prerequisite to restore physiological glenohumeral joint function. Clinical observations often show a secondary dislocation and subsequent resorption of the bony anchor points like the greater and lesser tuberosity at the rotator cuff t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0483-7

    authors: Baumgartner D,Lorenzetti SR,Mathys R,Gasser B,Stüssi E

    更新日期:2009-05-01 00:00:00

  • Frequency range extension of spectral analysis of pulse rate variability based on Hilbert-Huang transform.

    abstract::Heart rate variability (HRV) is a well-accepted indicator for neural regulatory mechanisms in cardiovascular circulation. Its spectrum analysis provides the powerful means of observing the modulation between sympathetic and parasympathetic nervous system. The timescale of HRV is limited by discrete beat-to-beat time i...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1135-5

    authors: Chang CC,Hsiao TC,Hsu HY

    更新日期:2014-04-01 00:00:00

  • Enrichment of cardiac pacemaker-like cells: neuregulin-1 and cyclic AMP increase I(f)-current density and connexin 40 mRNA levels in fetal cardiomyocytes.

    abstract::Generation of a large number of cells belonging to the cardiac pacemaker system would constitute an important step towards their utilization as a biological cardiac pacemaker system. The aim of the present study was to identify factors, which might induce transformation of a heterogenous population of fetal cardiomyoc...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0164-3

    authors: Ruhparwar A,Er F,Martin U,Radke K,Gruh I,Niehaus M,Karck M,Haverich A,Hoppe UC

    更新日期:2007-02-01 00:00:00

  • Role of the calcaneal inclination in the energy storage capacity of the human foot--a biomechanical model.

    abstract::The energy storage capacity of the human foot as a passive structure depends on both its geometry and elastic properties. The present study examines theoretically the relationship between the energy stored in the longitudinal arch and the inclination of the calcaneus, when a vertical load is applied. A simple two-dime...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441770

    authors: Simkin A,Leichter I

    更新日期:1990-03-01 00:00:00

  • Haemodynamic model of a unilateral iliac stenosis with an aortoiliac bypass.

    abstract::A hydrodynamic model for the part of the human arterial network below the renal arteries has been constructed using specially fabricated distensible tubes and a pulsatile pump to simulate an aortoiliac bypass. The experiments and the computer model indicated that no 'steal' occurred due to the insertion of the bypass ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441802

    authors: Helal MA,Watts KC,Marble AE

    更新日期:1993-11-01 00:00:00

  • Model for the assessment of heart period and arterial pressure variability interactions and of respiration influences.

    abstract::A model which assesses the closed-loop interaction between heart period (HP) and arterial pressure (AP) variabilities and the influence of respiration on both is applied to evaluate the sources of low frequency (LF approximately 0.1 Hz) and high frequency (HF, respiratory rate approximately 0.25 Hz) in conscious dogs ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02518911

    authors: Baselli G,Cerutti S,Badilini F,Biancardi L,Porta A,Pagani M,Lombardi F,Rimoldi O,Furlan R,Malliani A

    更新日期:1994-03-01 00:00:00

  • Numerical assessment of bone remodeling around conventionally and early loaded titanium and titanium-zirconium alloy dental implants.

    abstract::The aim of this study was to investigate conventionally and early loaded titanium and titanium-zirconium alloy implants by three-dimensional finite element stress analysis. Three-dimensional model of a dental implant was created and a thread area was established as a region of interest in trabecular bone to study a lo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1256-0

    authors: Akça K,Eser A,Çavuşoğlu Y,Sağırkaya E,Çehreli MC

    更新日期:2015-05-01 00:00:00

  • Arterial reservoir-excess pressure and ventricular work.

    abstract::This study is based on the hypothesis that the pressure within the arterial network can be usefully decomposed as the sum of a reservoir pressure and an excess pressure. The reservoir pressure waveform is defined to be the same in each vessel but delayed by the wave travel time from the root of the aorta. Using calcul...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0872-1

    authors: Parker KH,Alastruey J,Stan GB

    更新日期:2012-04-01 00:00:00

  • An atlas-based multimodal registration method for 2D images with discrepancy structures.

    abstract::An atlas-based multimodal registration method for 2-dimension images with discrepancy structures was proposed in this paper. Atlas was utilized for complementing the discrepancy structure information in multimodal medical images. The scheme includes three steps: floating image to atlas registration, atlas to reference...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1808-1

    authors: Lv W,Chen H,Peng Y,Li Y,Li J

    更新日期:2018-11-01 00:00:00

  • Interaction between steady flow and individualised compliant segments: application to upper airways.

    abstract::To describe upper airway obstruction in patients with sleep apnea syndrome, the steady state solutions of a simple model of local pharyngeal obstruction were studied. Importantly, the present model embodies a series of two individualised elements, each having its own compliance, which enables the consideration, from a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510972

    authors: Fodil R,Ribreau C,Louis B,Lofaso F,Isabey D

    更新日期:1997-11-01 00:00:00

  • Modeling the effect of tilting, passive leg exercise, and functional electrical stimulation on the human cardiovascular system.

    abstract::Long periods of bed rest negatively affect the human body organs, notably the cardiovascular system. To avert these negative effects and promote functional recovery in patients dealing with prolonged bed rest, the goal is to mobilize them as early as possible while controlling and stabilizing their cardiovascular syst...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1628-8

    authors: Sarabadani Tafreshi A,Okle J,Klamroth-Marganska V,Riener R

    更新日期:2017-09-01 00:00:00

  • Improvement of wireless power transmission efficiency of implantable subcutaneous devices by closed magnetic circuit mechanism.

    abstract::Induction coils were fabricated based on flexible printed circuit board for inductive transcutaneous power transmission. The coil had closed magnetic circuit (CMC) structure consisting of inner and outer magnetic core. The power transmission efficiency of the fabricated device was measured in the air and in vivo condi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0939-z

    authors: Jo SE,Joung S,Suh JK,Kim YJ

    更新日期:2012-09-01 00:00:00

  • Detection of the third heart sound using a tailored wavelet approach: method verification.

    abstract::Heart sounds can be considered as mechanical fingerprints of myocardial function. The third heart sound normally occurs in children but disappears with maturation. The sound can also appear in patients with heart failure. The sound is characterised by its low-amplitude and low-frequency content, which makes it difficu...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345957

    authors: Hult P,Fjällbrant T,Hildén K,Dahlström U,Wranne B,Ask P

    更新日期:2005-03-01 00:00:00

  • Visualisation method of spatial interictal discharges in temporal epilepsy patients using magneto-encephalogram.

    abstract::The aim of the study was to develop a method for investigating how interictal epileptic discharges in temporal epilepsy patients are activated spatially. The activity was measured using magneto-encephalography (MEG). The MEG data were used to produce a current-arrow map that reflected the topographic distribution of t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344215

    authors: Kandori A,Oe H,Miyashita K,Date H,Yamada N,Naritomi H,Chiba Y,Murakami M,Miyashita T,Tsukada K

    更新日期:2002-05-01 00:00:00

  • A unified treatment of the reference estimation problem in depth EEG recordings.

    abstract::The starting point of this paper is the analysis of the reference problem in intra-cerebral electroencephalographic (iEEG) recordings. It is well accepted that both surface and depth EEG signals are always recorded with respect to some unknown time-varying signal called reference. This article discusses different meth...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0946-0

    authors: Madhu N,Ranta R,Maillard L,Koessler L

    更新日期:2012-10-01 00:00:00

  • Modelling and multi-parametric control for delivery of anaesthetic agents.

    abstract::This article presents model predictive controllers (MPCs) and multi-parametric model-based controllers for delivery of anaesthetic agents. The MPC can take into account constraints on drug delivery rates and state of the patient but requires solving an optimization problem at regular time intervals. The multi-parametr...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0604-3

    authors: Dua P,Dua V,Pistikopoulos EN

    更新日期:2010-06-01 00:00:00

  • Dynamic thermographic imaging method for quantifying dermal perfusion: potential and limitations.

    abstract::A new method of quantifying dermal perfusion on a regional basis using a dynamic thermographic technique is investigated. The technique is based on the relationship between dermal perfusion and the rate of skin surface reheating following the application of a transient cold challenge predicted by a theoretical model. ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441468

    authors: Wilson SB,Spence VA

    更新日期:1989-09-01 00:00:00