Enrichment of cardiac pacemaker-like cells: neuregulin-1 and cyclic AMP increase I(f)-current density and connexin 40 mRNA levels in fetal cardiomyocytes.

Abstract:

:Generation of a large number of cells belonging to the cardiac pacemaker system would constitute an important step towards their utilization as a biological cardiac pacemaker system. The aim of the present study was to identify factors, which might induce transformation of a heterogenous population of fetal cardiomyocytes into cells with a pacemaker-like phenotype. Neuregulin-1 (alpha- and beta-isoform) or the cAMP was added to fresh cell cultures of murine embryonic cardiomyocytes. Quantitative northern blot analysis and flowcytometry were performed to detect the expression of connexins 40, 43 and 45. Patch clamp recordings in the whole cell configuration were performed to determine current density of I (f), a characteristic ion current of pacemaker cells. Fetal cardiomyocytes without supplement of neuregulin or cAMP served as control group. Neuregulin and cAMP significantly increased mRNA levels of connexin 40 (Cx-40), a marker of the early differentiating conduction system in mice. On the protein level, flowcytometry revealed no significant differences between treated and untreated groups with regard to the expression of connexins 40, 43 and 45. Treatment with cAMP (11.2 +/- 2.24 pA/pF; P < 0.001) and neuregulin-1-beta (6.23 +/- 1.07 pA/pF; P < 0.001) significantly increased the pacemaker current density compared to control cardiomyocytes (1.76 +/- 0.49 pA/pF). Our results indicate that neuregulin-1 and cAMP possess the capacity to cause significant transformation of a mixed population of fetal cardiomyocytes into cardiac pacemaker-like cells as shown by electrophysiology and increase of Cx-40 mRNA. This method may allow the development of a biological cardiac pacemaker system when applied to adult or embryonic stem cells.

journal_name

Med Biol Eng Comput

authors

Ruhparwar A,Er F,Martin U,Radke K,Gruh I,Niehaus M,Karck M,Haverich A,Hoppe UC

doi

10.1007/s11517-007-0164-3

subject

Has Abstract

pub_date

2007-02-01 00:00:00

pages

221-7

issue

2

eissn

0140-0118

issn

1741-0444

journal_volume

45

pub_type

杂志文章
  • Transesophageal left ventricular electrogram-recording and temporary pacing to improve patient selection for cardiac resynchronization.

    abstract::Cardiac resynchronization therapy (CRT) with biventricular pacing (BV) is an established therapy for heart failure (HF) patients with inter- and intraventricular conduction delay. The aim of this pilot study was to test the feasibility of both transesophageal measurement of left ventricular (LV) electrical delay and t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0767-6

    authors: Heinke M,Ismer B,Kühnert H,Figulla HR

    更新日期:2011-08-01 00:00:00

  • 3D shape analysis to reduce false positives for lung nodule detection systems.

    abstract::Using images from the Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI), we developed a methodology for classifying lung nodules. The proposed methodology uses image processing and pattern recognition techniques. To classify volumes of interest into nodules and non-nodules, we used shape mea...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1582-x

    authors: Filho AOC,Silva AC,de Paiva AC,Nunes RA,Gattass M

    更新日期:2017-08-01 00:00:00

  • Effect of mains interference on time coherent averaging.

    abstract::The paper deals with the influence of mains interference on time coherent averaging using an internal trigger. The general distribution of the time jitter is derived and applied to a simplified signal. The authors prove that no amount of averaging can do away with this type of interference. Finally, the deformation th...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02457827

    authors: Strackee J,Peper A

    更新日期:1992-09-01 00:00:00

  • Uncertainty assessment of gamma-aminobutyric acid concentration of different brain regions in individual and group using residual bootstrap analysis.

    abstract::The aim of this work is to quantify individual and regional differences in the relative concentration of gamma-aminobutyric acid (GABA) in human brain with in vivo magnetic resonance spectroscopy. Spectral editing Mescher-Garwood point resolved spectroscopy (MEGA-PRESS) sequence and GABA analysis toolkit (Gannet) were...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1579-5

    authors: Chen M,Liao C,Chen S,Ding Q,Zhu D,Liu H,Yan X,Zhong J

    更新日期:2017-06-01 00:00:00

  • Clinical application of modified bag-of-features coupled with hybrid neural-based classifier in dengue fever classification using gene expression data.

    abstract::Dengue fever detection and classification have a vital role due to the recent outbreaks of different kinds of dengue fever. Recently, the advancement in the microarray technology can be employed for such classification process. Several studies have established that the gene selection phase takes a significant role in ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1722-y

    authors: Chatterjee S,Dey N,Shi F,Ashour AS,Fong SJ,Sen S

    更新日期:2018-04-01 00:00:00

  • Chaotic behavior of the coronary circulation.

    abstract::The regulation of the coronary circulation is a complex paradigm in which many inputs that influence vasomotor tone have to be integrated to provide the coronary vasomotor adjustments to cardiac metabolism and to perfusion pressure. We hypothesized that the integration of many disparate signals that influence membrane...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0329-8

    authors: Trzeciakowski J,Chilian WM

    更新日期:2008-05-01 00:00:00

  • Physiological quality assessment of stored whole blood by means of electrical measurements.

    abstract::The physiological parameters of blood such as extracellular Na(+), K(+), Cl(-), pH, 2,3-DPG and ATP and the complex electrical impedance were measured using whole blood samples from 31 male donors (21 donors form the training set and ten donors were used for testing), on the 0th, 10th and 21st day of blood bank storag...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0206-x

    authors: Ulgen Y,Sezdi M

    更新日期:2007-07-01 00:00:00

  • French legal framework relating to human tissues and cells.

    abstract::Thousands of patients receive human tissue grafts every year. Developments in cell and tissue engineering have also increased considerably the number of available products of human origin. France has very strict regulations, in part stimulated by problems of public health and ethics that have emerged in recent years a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344783

    authors: Pascal P,Damour O,Colpart JJ,Braye F

    更新日期:2000-03-01 00:00:00

  • Measurement of retinal vascular tortuosity and its application to retinal pathologies.

    abstract::The tortuosity of retinal blood vessels is an important diagnostic indicator for a number of retinal pathologies. We applied robust quantitative tortuosity metrics, which are well suited to automated detection and measurement, to retinal fluorescein images of normal and diseased vessels exhibiting background diabetic ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0559-4

    authors: Dougherty G,Johnson MJ,Wiers MD

    更新日期:2010-01-01 00:00:00

  • Rheological modelling of leukocytes.

    abstract::A three-layer Newtonian model is investigated using a combined Eulerian-Lagrangian computational method to describe the dynamic behaviour of leukocytes. The model, composed of a cell membrane (outer layer), cytoplasm (middle layer) and nucleus (inner layer), can better describe the recovery characteristics because lar...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510753

    authors: Tran-Son-Tay R,Kan HC,Udaykumar HS,Damay E,Shyy W

    更新日期:1998-03-01 00:00:00

  • Regulation of neurofilament interactions in vitro by natural and synthetic polypeptides sharing Lys-Ser-Pro sequences with the heavy neurofilament subunit NF-H: neurofilament crossbridging by antiparallel sidearm overlapping.

    abstract::Neurofilaments are organised into parallel bundles in axons through crossbridges formed by lateral projections of neurofilament subunits. Pure neurofilaments form gels in vitro, consisting of interconnected parallel arrays of filaments regulated by the phosphorylation level of neurofilament subunits. Neurofilament-ass...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02522486

    authors: Gou JP,Gotow T,Janmey PA,Leterrier JF

    更新日期:1998-05-01 00:00:00

  • Comparison of heart rate variability spectra using generic relationships of their input signals.

    abstract::Spectral analysis of heart rate variability (HRV) is an accepted method for assessment of cardiac autonomic function and its relationship to numerous disorders and diseases. Various non-parametric methods for HRV estimation have been developed. The spectrum of counts, the instantaneous heart rate spectrum and the inte...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02524426

    authors: Mitov IP,Daskalov IK

    更新日期:1998-09-01 00:00:00

  • Quantitative assessment of lower limbs gross motor function in children with cerebral palsy based on surface EMG and inertial sensors.

    abstract::Taking advantage of motion sensing technology, a quantitative assessment method for lower limbs motor function of cerebral palsy (CP) based on the gross motor function measurement (GMFM)-24 scale was explored in this study. According to the motion analysis on GMFM-24 scale, we translated the assessment problem of GMFM...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02076-w

    authors: Chen X,Wu Q,Tang L,Cao S,Zhang X,Chen X

    更新日期:2020-01-01 00:00:00

  • Propagation of pacemaker activity.

    abstract::Spontaneous activity of specific regions (e.g., the Sinoatrial node, SAN) is essential for the normal activation sequence of the heart and also serve as a primary means of modulating cardiac rate by sympathetic tone and circulating catecholamines. The mechanisms of how a small SAN region can electrically drive a much ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-006-0102-9

    authors: Joyner RW,Wilders R,Wagner MB

    更新日期:2007-02-01 00:00:00

  • Analysis and decision based on specialist self-assessment for prognosis factors of acute leukemia integrating data-driven Bayesian network and fuzzy cognitive map.

    abstract::The purpose of the present study is to analyze the prognostic factors of acute leukemia and to construct a decision model based on a causal relationship between the factors of this disease to assist medical specialists. In medical decisions, to reach effective, quick, and reliable results, there is a need for a simple...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02267-w

    authors: Jahangoshai Rezaee M,Sadatpour M,Ghanbari-Ghoushchi N,Fathi E,Alizadeh A

    更新日期:2020-11-01 00:00:00

  • Determining appropriate models for joint control using surface electrical stimulation of soleus in spinal cord injury.

    abstract::The mechanical impedance of the ankle joint during electrical stimulation of the soleus is studied by applying constant-velocity 10 degrees angular perturbations to the ankle and measuring the resultant torque. Both neurologically intact subjects and spinal cord injured subjects are tested. Lumped, piecewise linear mo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02512522

    authors: Flaherty B,Robinson C,Agarwal G

    更新日期:1994-05-01 00:00:00

  • Optimal chest compression in cardiopulmonary resuscitation depends upon thoracic and back support stiffness.

    abstract::A biomechanical analysis of the constant peak displacement and constant peak force methods of cardiopulmonary resuscitation (CPR) has revealed that optimal CC performance strongly depends on back support stiffness, CC rate, and the thoracic stiffness of the patient being resuscitated. Clinically the results presented ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0963-z

    authors: Dellimore KH,Scheffer C

    更新日期:2012-12-01 00:00:00

  • Inducing therapeutic hypothermia via selective brain cooling: a finite element modeling analysis.

    abstract::Therapeutic hypothermia is a treatment method to reduce brain injuries after stroke, especially for cerebral ischemia. This study investigates in the temperature distribution of the head within selective brain cooling (SBC). Anatomically accurate geometries based on CT images of head and neck regions are used to devel...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01962-7

    authors: Yin L,Jiang H,Zhao W,Li H

    更新日期:2019-06-01 00:00:00

  • Pulsatile blood flow in total cavopulmonary connection: a comparison between Y-shaped and T-shaped geometry.

    abstract::Single-ventricle anomaly is a hereditary heart disease that is characterized by anatomical malformations. The main consequence of this malformation is desaturated blood flow, which without proper treatment increases the risk of death. The classical treatment is based on a three-stage palliative procedure which should ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1499-4

    authors: Rajabzadeh-Oghaz H,Firoozabadi B,Saidi MS,Monjezi M,Navabi Shirazi MA,Malakan Rad E

    更新日期:2017-02-01 00:00:00

  • Detection of compressed tracheal sound patterns with large amplitude variation during sleep.

    abstract::The objective of the present work was to develop automated methods for the compressed tracheal breathing sound analysis. Overnight tracheal breathing sound was recorded from ten apnoea patients. From each patient, three different types of tracheal sound deflection pattern, each of 10 min duration, were visually scored...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0317-z

    authors: Kulkas A,Rauhala E,Huupponen E,Virkkala J,Tenhunen M,Saastamoinen A,Himanen SL

    更新日期:2008-04-01 00:00:00

  • Classification of pure conduct disorder from healthy controls based on indices of brain networks during resting state.

    abstract::Conduct disorder (CD) is an important mental health problem in childhood and adolescence. There is presently a trend of revealing neural mechanisms using measures of brain networks. This study goes further by presenting a classification scheme to distinguish subjects with CD from typically developing healthy subjects ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02215-8

    authors: Zhang J,Liu Y,Luo R,Du Z,Lu F,Yuan Z,Zhou J,Li S

    更新日期:2020-09-01 00:00:00

  • Improvement of wireless power transmission efficiency of implantable subcutaneous devices by closed magnetic circuit mechanism.

    abstract::Induction coils were fabricated based on flexible printed circuit board for inductive transcutaneous power transmission. The coil had closed magnetic circuit (CMC) structure consisting of inner and outer magnetic core. The power transmission efficiency of the fabricated device was measured in the air and in vivo condi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0939-z

    authors: Jo SE,Joung S,Suh JK,Kim YJ

    更新日期:2012-09-01 00:00:00

  • Modelling and numerical simulation of the in vivo mechanical response of the ascending aortic aneurysm in Marfan syndrome.

    abstract::Marfan syndrome (MFS) is a genetic disorder that affects connective tissue, impairing cardiovascular structures and function, such as heart valves and aorta. Thus, patients with Marfan disease have a higher risk of developing circulatory problems associated with mitral and aortic valves prolapse, manifested as dilated...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1524-7

    authors: García-Herrera CM,Celentano DJ,Herrera EA

    更新日期:2017-03-01 00:00:00

  • Measurement of the local aortic stiffness by a non-invasive bioelectrical impedance technique.

    abstract::Aortic stiffness measurement is well recognized as an independent predictor of cardiovascular mortality and morbidity. Recently, a simple method has been proposed for the evaluation of the local aortic stiffness (AoStiff) using a non-invasive bioelectrical impedance (BI) technique. This approach relies on a novel inte...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0741-3

    authors: Collette M,Lalande A,Willoteaux S,Leftheriotis G,Humeau A

    更新日期:2011-04-01 00:00:00

  • Estimation of habituation and signal-to-noise ratio of cortical evoked potentials to oesophageal electrical and mechanical stimulation.

    abstract::Electrical and mechanical stimulation of the oesophagus has been recently proposed to examine the physiological effects of autonomic stimulation in humans. Cortical evoked potentials (EPs) to oesophageal stimulation provide an assessment of afferent fibres and central processing. However, habituation takes place durin...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02534088

    authors: Kamath MV,Tougas G,Hollerbach S,Premji R,Fitzpatrick D,Shine G,Upton AR

    更新日期:1997-07-01 00:00:00

  • Frequency range extension of spectral analysis of pulse rate variability based on Hilbert-Huang transform.

    abstract::Heart rate variability (HRV) is a well-accepted indicator for neural regulatory mechanisms in cardiovascular circulation. Its spectrum analysis provides the powerful means of observing the modulation between sympathetic and parasympathetic nervous system. The timescale of HRV is limited by discrete beat-to-beat time i...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1135-5

    authors: Chang CC,Hsiao TC,Hsu HY

    更新日期:2014-04-01 00:00:00

  • Estimation of mean arterial pressure from the oscillometric cuff pressure: comparison of different techniques.

    abstract::Mean arterial pressure (MAP) is determined in most automated oscillometric blood pressure devices, but its derivation has been little studied. In this research, different techniques were studied and compared with the auscultatory technique. Auscultatory systolic and diastolic blood pressure (SBP and DBP) were obtained...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0694-y

    authors: Zheng D,Amoore JN,Mieke S,Murray A

    更新日期:2011-01-01 00:00:00

  • Apnea bradycardia detection based on new coupled hidden semi Markov model.

    abstract::In this paper, a method for apnea bradycardia detection in preterm infants is presented based on coupled hidden semi Markov model (CHSMM). CHSMM is a generalization of hidden Markov models (HMM) used for modeling mutual interactions among different observations of a stochastic process through using finite number of hi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02277-8

    authors: Montazeri Ghahjaverestan N,Shamsollahi MB,Ge D,Beuchée A,Hernández AI

    更新日期:2021-01-01 00:00:00

  • MicroPACS: a PC-based small PACS implementation.

    abstract::To make picture archiving and communication systems (PACS) a practical reality for small-scale structures, it appears necessary to build a network that integrates and optimises production management, analysis and storage of images, and to include the ability to communicate with other similar remote structures. To solv...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02458046

    authors: Duchêne J,Lerallut JF,Gong N,Kanz R

    更新日期:1993-05-01 00:00:00

  • Continuous cardiac output monitoring system.

    abstract::A continuous cardiac output monitoring system has been developed in the laboratory to allow the real-time measurement of the cardiac output. This form of continuous cardiac output measurement allows the doctor to view the beat-to-beat cardiac output and can be employed to measure artery constrictions as well. The sens...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345272

    authors: Tjin SC,Ho YC,Lam YZ,Hao J,Ng BK

    更新日期:2001-01-01 00:00:00