Apnea bradycardia detection based on new coupled hidden semi Markov model.

Abstract:

:In this paper, a method for apnea bradycardia detection in preterm infants is presented based on coupled hidden semi Markov model (CHSMM). CHSMM is a generalization of hidden Markov models (HMM) used for modeling mutual interactions among different observations of a stochastic process through using finite number of hidden states with corresponding resting time. We introduce a new set of equations for CHSMM to be integrated in a detection algorithm. The detection algorithm was evaluated on a simulated data to detect a specific dynamic and on a clinical dataset of electrocardiogram signals collected from preterm infants for early detection of apnea bradycardia episodes. For simulated data, the proposed algorithm was able to detect the desired dynamic with sensitivity of 96.67% and specificity of 98.98%. Furthermore, the method detected the apnea bradycardia episodes with 94.87% sensitivity and 96.52% specificity with mean time delay of 0.73 s. The results show that the algorithm based on CHSMM is a robust tool for monitoring of preterm infants in detecting apnea bradycardia episodes. Graphical Abstract Apnea Bradycardia detection using Coupled hidden semi Markov Model from electrocardiography. In this model, a sequence of hidden states is assigned to each observation based on the effects of previous states of all observations.

journal_name

Med Biol Eng Comput

authors

Montazeri Ghahjaverestan N,Shamsollahi MB,Ge D,Beuchée A,Hernández AI

doi

10.1007/s11517-020-02277-8

subject

Has Abstract

pub_date

2021-01-01 00:00:00

pages

1-11

issue

1

eissn

0140-0118

issn

1741-0444

pii

10.1007/s11517-020-02277-8

journal_volume

59

pub_type

杂志文章
  • Finite element modeling of the growth plate in a detailed spine model.

    abstract::Very few computer models of the spine integrate vertebral growth plates to investigate their mechanical behavior and potential impacts on bone growth. An approach was developed to generate a finite element (FE) model of the lumbar spine and their connective tissues including the growth plate, which allowed a personali...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0220-z

    authors: Sylvestre PL,Villemure I,Aubin CE

    更新日期:2007-10-01 00:00:00

  • Theoretical study of the effect of local flow disturbances on the concentration of low-density lipoproteins at the luminal surface of end-to-end anastomosed vessels.

    abstract::To elucidate the mechanisms of localisation of intimal hyperplasia in anastomosed arteries, the effects of flow disturbances on the transport of low-density lipoproteins (LDLs) from the flowing blood to the wall of end-to-end anastomosed arteries, with and without a moderate stenosis, were studied theoretically by mea...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345458

    authors: Wada S,Koujiya M,Karino T

    更新日期:2002-09-01 00:00:00

  • Factors affecting electrode-gel-skin interface impedance in electrical impedance tomography.

    abstract::The magnitude, mismatch and temporal variations of the electrode-gel-skin interface impedance can cause problems in electrical impedance tomography (EIT) measurement. It is shown that at the high frequencies generally encountered in EIT the capacitive properties of the electrode interface, and especially those of the ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/BF02523842

    authors: McAdams ET,Jossinet J,Lackermeier A,Risacher F

    更新日期:1996-11-01 00:00:00

  • Computer-controlled positive displacement pump for physiological flow simulation.

    abstract::A computer-controlled pump for use both in the study of vascular haemodynamics and in the calibration of clinical devices which measure blood flow is designed. The novel design of this pump incorporates two rack-mounted pistons, driven into opposing cylinders by a micro-stepping motor. This approach allows the product...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446086

    authors: Holdsworth DW,Rickey DW,Drangova M,Miller DJ,Fenster A

    更新日期:1991-11-01 00:00:00

  • Effect of signal length on the performance of independent component analysis when extracting the lambda wave.

    abstract::The aim of the study was to investigate the effect of signal length on the performance of a signal source separation method, independent component analysis (ICA), when extracting the visual evoked potential (EP) lambda wave from saccade-related electro-encephalogram (EEG) waveforms. A method was devised that enabled t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348134

    authors: Vigon L,Saatchi R,Mayhew JE,Taroyan NA,Frisby JP

    更新日期:2002-03-01 00:00:00

  • Finite element analysis of brain contusion: an indirect impact study.

    abstract::The mechanism of brain contusion has been investigated using a series of three-dimensional (3D) finite element analyses. A head injury model was used to simulate forward and backward rotation around the upper cervical vertebra. Intracranial pressure and shear stress responses were calculated and compared. The results ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02347044

    authors: Huang HM,Lee MC,Lee SY,Chiu WT,Pan LC,Chen CT

    更新日期:2000-05-01 00:00:00

  • Inertial measurement units furnish accurate trunk trajectory reconstruction of the sit-to-stand manoeuvre in healthy subjects.

    abstract::A simple inertial measurement unit (IMU) incorporating rate gyroscopes and accelerometers has been tested to investigate the trunk kinematics during the sit-to-stand. It was affixed at trunk L5 level and used for sit-to-stand position and orientation reconstruction. The method was validated with standard optoelectroni...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0224-8

    authors: Giansanti D,Maccioni G,Benvenuti F,Macellari V

    更新日期:2007-10-01 00:00:00

  • Gastric emptying of solids measured by means of magnetised iron oxide powder.

    abstract::The aim of this study was to develop a radiation-free method to measure gastric emptying. Such a method would be useful e.g. for patients who need repeated measurements and in pregnancy. Ferrimagnetic particles (gamma-Fe2O3), ingested within a solid test meal (pancakes), were magnetised by an applied magnetic field. A...

    journal_title:Medical & biological engineering & computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF02522849

    authors: Forsman M

    更新日期:1998-01-01 00:00:00

  • Viscoelastic response of human hair cortex.

    abstract::The present study describes a new methodological approach which allows the separate analysis and quantitative determination of the viscous and elastic components of human hair using a computerised experimental system. In a first series of experiments subsequent to the estimation of the cross-sectional surface area of ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446198

    authors: Nikiforidis G,Balas C,Tsambaos D

    更新日期:1992-01-01 00:00:00

  • Analysis of four methods of measuring three-dimensional pelvic tilt in the lateral decubitus position.

    abstract::Proper alignment of acetabular implantation is necessary for good patient outcomes and preventing complications or additional surgeries in total hip arthroplasty (THA). Rotation of the pelvis in lateral decubitus (LD) is typically not accounted for as surgeons use the surgery table as a reference plane to align implan...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02235-4

    authors: Stadnyk M,Liu T,Arezodar FF,Westover L,Carvajal Alba JA,Masson E,Beaupre L,Jaremko JL,El-Rich M

    更新日期:2020-10-01 00:00:00

  • Empirical mode decomposition: a method to reduce low frequency interferences from surface electroenterogram.

    abstract::The surface electroenterogram (EEnG) is a non-invasive method of studying myoelectrical bowel activity. However, surface EEnG recordings are contaminated by cardiac activity, respiratory and motion artifacts, and other sources of interference. The aim of this work is to remove the respiration artifact and the very low...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0189-7

    authors: Ye Y,Garcia-Casado J,Martinez-de-Juan JL,Ponce JL

    更新日期:2007-06-01 00:00:00

  • Prediction of O-glycosylation sites based on multi-scale composition of amino acids and feature selection.

    abstract::Protein glycosylation is one of the most important and complex post-translational modification that provides greater proteomic diversity than any other post-translational modification. Fast and reliable computational methods to identify glycosylation sites are in great demand. Two key issues, feature encoding and feat...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1268-9

    authors: Chen Y,Zhou W,Wang H,Yuan Z

    更新日期:2015-06-01 00:00:00

  • A unified canonical correlation analysis-based framework for removing gradient artifact in concurrent EEG/fMRI recording and motion artifact in walking recording from EEG signal.

    abstract::Artifacts cause distortion and fuzziness in electroencephalographic (EEG) signal and hamper EEG analysis, so it is necessary to remove them prior to the analysis. Particularly, artifact removal becomes a critical issue in experimental protocols with significant inherent recording noise, such as mobile EEG recordings a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1620-3

    authors: Li J,Chen Y,Taya F,Lim J,Wong K,Sun Y,Bezerianos A

    更新日期:2017-09-01 00:00:00

  • A multi-electrode array and inversion technique for retrieving six conductivities from heart potential measurements.

    abstract::A method for accurately finding cardiac bidomain conductivity parameters is a crucial part of efforts to study and understand the electrical functioning of the heart. The bidomain model considers current flowing along (longitudinal) and across (transverse) sheets of cardiac fibres, as well as between these sheets (nor...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1101-2

    authors: Johnston BM,Johnston PR

    更新日期:2013-12-01 00:00:00

  • Pulse transit time based respiratory rate estimation with singular spectrum analysis.

    abstract::Respiratory rate (RR) is an important vital sign which can be difficult to measure accurately and unobtrusively in routine clinical practice. Pulse transit time (PTT), on the other hand, is unobtrusive to collect from electrocardiogram (ECG) and photoplethysmogram (PPG) signals. Using PTT is a novel method to estimate...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02088-6

    authors: Ding X,Yan BP,Karlen W,Zhang YT,Tsang HK

    更新日期:2020-02-01 00:00:00

  • Experimental and numerical investigation on soft tissue dynamic response due to turbulence-induced arterial vibration.

    abstract::Peripheral arterial occlusive disease is a serious cardiovascular disorder. The arterial occlusion leads to turbulent flow and arterial sound generation on the inner vessel wall. Stenosis-induced vibro-acoustic waves propagate through the surrounding soft tissues and reach the skin surface. In this study, the feasibil...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01995-y

    authors: Salman HE,Yazicioglu Y

    更新日期:2019-08-01 00:00:00

  • Classification of breast masses in mammograms using genetic programming and feature selection.

    abstract::Mammography is a widely used screening tool and is the gold standard for the early detection of breast cancer. The classification of breast masses into the benign and malignant categories is an important problem in the area of computer-aided diagnosis of breast cancer. A small dataset of 57 breast mass images, each wi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0077-6

    authors: Nandi RJ,Nandi AK,Rangayyan RM,Scutt D

    更新日期:2006-08-01 00:00:00

  • Propagation of pacemaker activity.

    abstract::Spontaneous activity of specific regions (e.g., the Sinoatrial node, SAN) is essential for the normal activation sequence of the heart and also serve as a primary means of modulating cardiac rate by sympathetic tone and circulating catecholamines. The mechanisms of how a small SAN region can electrically drive a much ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-006-0102-9

    authors: Joyner RW,Wilders R,Wagner MB

    更新日期:2007-02-01 00:00:00

  • Analysis of the O-wave in acute right ventricular apex impedance measurements with a standard pacing lead in animals.

    abstract::Modern pacemakers (implantable devices used for maintaining an appropriate heart rate in patients) can use an intracardiac ventricular impedance signal for physiological cardiac stimulation control. Intracardiac ventricular impedance from nine animal subjects is analysed and presented (seven sheep: 49.0 +/- 6.5 kg, si...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345448

    authors: Järverud K,Ollmar S,Brodin LA

    更新日期:2002-09-01 00:00:00

  • Development of automatized new indices for radiological assessment of chest-wall deformity and its quantitative evaluation.

    abstract::Pre-operative diagnosis of chest-wall deformity is important for successful surgical correction and post-operative evaluation of funnel chest patients. However, conventional indices that define the severity of deformity have several limitations; manually calculated and cannot supply information about asymmetry. We dev...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0367-2

    authors: Kim HC,Park HJ,Ham SY,Nam KW,Choi SY,Oh JS,Choi H,Jeong GS,Park SW,Kim MG,Sun K

    更新日期:2008-08-01 00:00:00

  • Multi-parametric cardiorespiratory analysis in late-preterm, early-term, and full-term infants at birth.

    abstract::Infants born at 35-37 weeks' gestational age (GA) are at higher risk for a range of pathological conditions and poorer neurodevelopmental outcomes. However, mechanisms responsible are not fully understood. The purpose of this paper is to use traditional and novel techniques to assess newborn autonomic development as a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1866-4

    authors: Lucchini M,Burtchen N,Fifer WP,Signorini MG

    更新日期:2019-01-01 00:00:00

  • Dielectric relaxation of a protein-water system in atherosclerotic artery wall.

    abstract::Measurements of the dielectric properties of healthy and atherosclerotic human artery tissues were made in the frequency range of 100 Hz-100 kHz and temperatures from 22 to 260 degrees C. The temperature dependencies of the dielectric parameters for healthy tissues reveal distinctively the temperature ranges correspon...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0181-2

    authors: Brzeziński J,Oszkinis G,Marzec E

    更新日期:2007-06-01 00:00:00

  • Duchenne muscular dystrophy quantification: a multivariate analysis of surface EMG.

    abstract::The paper describes a method of quantifying Duchenne muscular dystrophy which is examiner independent and uses surface electromyographic signals (EMG). A standardised protocol is proposed. Spectral parameters are first computed from digitised EMG, then a polynomial model is deduced from the evolution of each parameter...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446966

    authors: Priez A,Duchene J,Goubel F

    更新日期:1992-05-01 00:00:00

  • Time-varying digital filtering of ECG baseline wander.

    abstract::Time-varying filtering techniques are applied to the problem of baseline correction by letting the cut-off frequency of a linear filter be controlled by the low-frequency properties of the ECG signal. The time-varying filter is implemented as a bank of linear low-pass filters, in which each filter has a slightly diffe...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441986

    authors: Sörnmo L

    更新日期:1993-09-01 00:00:00

  • Numerical assessment of bone remodeling around conventionally and early loaded titanium and titanium-zirconium alloy dental implants.

    abstract::The aim of this study was to investigate conventionally and early loaded titanium and titanium-zirconium alloy implants by three-dimensional finite element stress analysis. Three-dimensional model of a dental implant was created and a thread area was established as a region of interest in trabecular bone to study a lo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1256-0

    authors: Akça K,Eser A,Çavuşoğlu Y,Sağırkaya E,Çehreli MC

    更新日期:2015-05-01 00:00:00

  • An atlas-based multimodal registration method for 2D images with discrepancy structures.

    abstract::An atlas-based multimodal registration method for 2-dimension images with discrepancy structures was proposed in this paper. Atlas was utilized for complementing the discrepancy structure information in multimodal medical images. The scheme includes three steps: floating image to atlas registration, atlas to reference...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1808-1

    authors: Lv W,Chen H,Peng Y,Li Y,Li J

    更新日期:2018-11-01 00:00:00

  • Parallel conductance determination in cardiac volumetry using dilution manoeuvres: theoretical analysis and practical implications.

    abstract::Left ventricular volume calibration based on the conductance catheter depends on the correct determination of the parallel conductance (Gp). Baan's saline manoeuvre procedure leads to Gp by finding the end-systolic (Ges) and end-diastolic (Ged) conductances, for each beat of the dilution curve rising limb. After plott...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513284

    authors: Herrera MC,Olivera JM,Valentinuzzi ME

    更新日期:1999-03-01 00:00:00

  • Pulsatile blood flow in total cavopulmonary connection: a comparison between Y-shaped and T-shaped geometry.

    abstract::Single-ventricle anomaly is a hereditary heart disease that is characterized by anatomical malformations. The main consequence of this malformation is desaturated blood flow, which without proper treatment increases the risk of death. The classical treatment is based on a three-stage palliative procedure which should ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1499-4

    authors: Rajabzadeh-Oghaz H,Firoozabadi B,Saidi MS,Monjezi M,Navabi Shirazi MA,Malakan Rad E

    更新日期:2017-02-01 00:00:00

  • Matching between theoretical and experimental data for ELF ion transport effects.

    abstract::In recent years, several studies have been focused on the problem of nonthermal interaction between extremely low-frequency (ELF) electromagnetic fields and cell environment at membrane level. In the paper, to analyse the dynamic effects of weak static and harmonic fields on charged particles, some new considerations ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446654

    authors: D'Inzeo G,Galli A,Palombo A

    更新日期:1993-07-01 00:00:00

  • PC/VAX or standalone PC-based general purpose biological data collection system.

    abstract::A system, to collect, analyse and display biological data, is developed using IBM PC AT compatibles (PCs) or CED1401/1609 devices networked to a VAX environment. It can be operated in three separate modes: using the CED/IEEE/VAX network; using the PC/Ethernet/VAX network; as a standalone PC. The original system compri...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446881

    authors: Marlow SP,Mackenzie DA,Tomlinson JB

    更新日期:1993-01-01 00:00:00