Abstract:
:Artifacts cause distortion and fuzziness in electroencephalographic (EEG) signal and hamper EEG analysis, so it is necessary to remove them prior to the analysis. Particularly, artifact removal becomes a critical issue in experimental protocols with significant inherent recording noise, such as mobile EEG recordings and concurrent EEG-fMRI acquisitions. In this paper, we proposed a unified framework based on canonical correlation analysis for artifact removal. Raw signals were reorganized to construct a pair of matrices, based on which sources were sought through maximizing autocorrelation. Those sources related to artifacts were then removed by setting them as zeros, and the remaining sources were used to reconstruct artifact-free EEG. Both simulated and real recorded data were utilized to assess the proposed framework. Qualitative and quantitative results showed that the proposed framework was effective to remove artifacts from EEG signal. Specifically, the proposed method outperformed independent component analysis method for mitigating motion-related artifacts and had advantages for removing gradient artifact compared to the classical method (average artifacts subtraction) and the state-of-the-art method (optimal basis set) in terms of the combination of performance and computational complexity.
journal_name
Med Biol Eng Computjournal_title
Medical & biological engineering & computingauthors
Li J,Chen Y,Taya F,Lim J,Wong K,Sun Y,Bezerianos Adoi
10.1007/s11517-017-1620-3subject
Has Abstractpub_date
2017-09-01 00:00:00pages
1669-1681issue
9eissn
0140-0118issn
1741-0444pii
10.1007/s11517-017-1620-3journal_volume
55pub_type
杂志文章abstract::A new algorithm to resolve superimposed motor unit action potentials (MUAPs) is described, which uses a reduced search space and is based on the peel off approach. Knowledge specific to the problem domain, such as temporal relationships between and within motor unit action potential trains and MUAP energy information,...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02637020
更新日期:1996-01-01 00:00:00
abstract::A bicuspid aortic valve (BAV) is a congenital cardiac disorder where the valve consists of only two cusps instead of three, as in a normal tricuspid valve (TAV). Although 97 % of BAVs include asymmetric cusps, little or no prior studies have investigated the blood flow through a three-dimensional BAV and root. The aim...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-013-1055-4
更新日期:2013-08-01 00:00:00
abstract::Visual inspection of foetal heart rate (FHR) sequences is an important means of foetal well-being evaluation. The application of fractal features for classifying physiologically relevant FHR sequence patterns is reported. The use of fractal features is motivated by the difficulties exhibited by traditional classificat...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02510743
更新日期:1998-03-01 00:00:00
abstract::A technique to obtain the spacing distribution of macro- and microstructures of hypercholestrolemic liver, lymphoidlucosed liver, rhinosporidium of man and ethmoidal tumour of bovine is presented. The method uses signal processing of spatially averaged spectra of ultrasonic backscattering from tissues in the frequency...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02442608
更新日期:1990-11-01 00:00:00
abstract::The aim of the study was to develop a method for investigating how interictal epileptic discharges in temporal epilepsy patients are activated spatially. The activity was measured using magneto-encephalography (MEG). The MEG data were used to produce a current-arrow map that reflected the topographic distribution of t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344215
更新日期:2002-05-01 00:00:00
abstract::Computational modeling of the brain is crucial for the study of traumatic brain injury. An anatomically accurate model with refined details could provide the most accurate computational results. However, computational models with fine mesh details could take prolonged computation time that impedes the clinical transla...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-020-02262-1
更新日期:2020-11-01 00:00:00
abstract::Modern pacemakers (implantable devices used for maintaining an appropriate heart rate in patients) can use an intracardiac ventricular impedance signal for physiological cardiac stimulation control. Intracardiac ventricular impedance from nine animal subjects is analysed and presented (seven sheep: 49.0 +/- 6.5 kg, si...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345448
更新日期:2002-09-01 00:00:00
abstract::Results of self-consistent analyses of cells show the possibility of temperature increases at membranes in response to a single nanosecond, high-voltage pulse, at least over small sections of the membrane. Molecular Dynamics simulations indicate that such a temperature increase could facilitate poration, which is one ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-011-0745-z
更新日期:2011-06-01 00:00:00
abstract::Obstructive sleep apnea syndrome (OSAS) is a major public health problem. The golden reference for diagnosing OSAS is the sleep-laboratory based polysomnography (PSG). However, screening of population for OSAS may be practical and cost efficient only through ambulatory home recordings. In this work we aimed to design,...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-008-0418-8
更新日期:2009-01-01 00:00:00
abstract::This review is a commentary on recent, altered perspectives about biomedical engineering and its role in medicine. It is argued that, rather than being a peripheral specialty, medical engineering and engineering principles in general have a direct application to biochemical medicine and cell biology. A brief descripti...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/BF02446170
更新日期:1992-07-01 00:00:00
abstract::Implantable cardioverter defibrillators (ICDs) can store intracardiac electrograms (EGMs) in sinus rhythm (SR), at the onset of spontaneous ventricular tachyarrhythmias (VT) or during their course. This allows the investigation of unknown features of the heart electrical activity associated with different cardiac rhyt...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-005-0014-0
更新日期:2006-03-01 00:00:00
abstract::While matrix remodeling plays a key role in vascular physiology and pathology, the underlying mechanisms have remained incompletely understood. We studied the remodeling of collagen matrices by individual vascular smooth muscle cells (SMCs), clusters and monolayers. In addition, we focused on the contribution of trans...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-0916-6
更新日期:2012-07-01 00:00:00
abstract::Many studies concerning the internal work of human motion have used two-dimensional kinematic models to estimate kinetic energy of the segments. The generalised co-ordinate concept has been applied here to a simultaneous and bilateral gait analysis. A three-dimensional kinematic model based on quaternions has been dev...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02523852
更新日期:1996-11-01 00:00:00
abstract::Whether Fourier transform infra-red spectroscopy with an attenuated total reflection prism could be applied for noninvasive glucose measurement through oral mucosa was evaluated. As a result, the same absorbance peak at 1033 cm-1 as in glucose aqueous solution was found in the absorbance spectra through mucous membran...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02446645
更新日期:1993-07-01 00:00:00
abstract::An automatic power-generating system (AGS) which converts kinetic energy into electric energy for quartz watches was tested as a power source for implantable cardiac pacemakers. An automatic power-generating mechanism and a capacitor (0.33 F) were removed from a quartz watch (SEIKO) and encapsulated in a polyvinyl cas...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02513315
更新日期:1999-05-01 00:00:00
abstract::Electrocardiogram (ECG)-triggered laser Doppler perfusion monitoring (LDPM) was used to assess myocardial perfusion, with minimum myocardial tissue motion influence, during coronary artery bypass grafting (CABG). Thirteen subjects were investigated at six phases: pre- and post-CABG; post aorta cross-clamping; pre and ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02351031
更新日期:2005-09-01 00:00:00
abstract::The visco-elastic properties of living cells, measured to date by various authors, vary considerably, depending on the experimental methods and/or on the theoretical models used. In the present study, two mechanisms thought to be involved in cellular visco-elastic responses were analysed, based on the idea that the cy...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02349982
更新日期:2003-11-01 00:00:00
abstract::Several 3D reconstruction techniques deriving from stereoradiographic DLT have been presented during the last 15 years, but these techniques have usually been limited in accuracy because of the small number of corresponding anatomical landmarks identified on both radiographs. A new technique has recently been proposed...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344797
更新日期:2001-03-01 00:00:00
abstract::The management of postprandial glucose excursions in type 1 diabetes has a major impact on overall glycaemic control. In this work, we propose and evaluate various mechanistic models to characterize the disposal of meal-attributable glucose. Sixteen young volunteers with type 1 diabetes were subject to a variable-targ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-016-1509-6
更新日期:2017-02-01 00:00:00
abstract::Chronic obstructive pulmonary disease (COPD) is characterized by expiratory airflow limitation, but current diagnostic criteria only consider flow till the first second and are therefore strongly debated. We aimed to develop a data-based individualized model for flow decline and to explore the relationship between mod...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-014-1202-6
更新日期:2014-12-01 00:00:00
abstract::This work addresses the problem of estimating the conduction velocity (CV) of single motor unit (MU) action potentials from surface EMG signals detected with linear electrode arrays during voluntary muscle contractions. In ideal conditions, that is without shape or scale changes of the propagating signals and with add...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344807
更新日期:2001-03-01 00:00:00
abstract::During the study of velocities in the human ascending aorta it became necessary to establish a method for two-dimensional velocity profiles from discrete velocity data obtained from different heartbeats and with different techniques. A descriptive geometrical model was therefore developed and expanded to 16 elements e...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02442319
更新日期:1991-09-01 00:00:00
abstract::The development of computer technology now allows the quick and efficient automatic fluorescence microscopy generation of a large number of images of proteins in specific subcellular compartments using fluorescence microscopy. Digital image processing and pattern recognition technology can easily classify these images...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-018-01946-z
更新日期:2019-06-01 00:00:00
abstract::Electromyography (EMG) in a bio-driven system is used as a control signal, for driving a hand prosthesis or other wearable assistive devices. Processing to get informative drive signals involves three main modules: preprocessing, dimensionality reduction, and classification. This paper proposes a system for classifyin...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-018-1857-5
更新日期:2018-12-01 00:00:00
abstract::Deep brain stimulation (DBS) surgery is extensively used in the treatment of movement disorders. Nevertheless, methods to evaluate the clinical response during intraoperative stimulation tests to identify the optimal position for the implantation of the chronic DBS lead remain subjective. In this paper, we describe a ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-016-1559-9
更新日期:2017-05-01 00:00:00
abstract::Mammography is a widely used screening tool and is the gold standard for the early detection of breast cancer. The classification of breast masses into the benign and malignant categories is an important problem in the area of computer-aided diagnosis of breast cancer. A small dataset of 57 breast mass images, each wi...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-006-0077-6
更新日期:2006-08-01 00:00:00
abstract::Apoptosis proteins are related to many diseases. Obtaining the subcellular localization information of apoptosis proteins is helpful to understand the mechanism of diseases and to develop new drugs. At present, the researchers mainly focus on the primary protein sequences, so there is still room for improvement in the...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02045-3
更新日期:2019-12-01 00:00:00
abstract::Axial and transverse components of liquid velocity are measured by laser Doppler anemometer in a perspex tube that has been deformed at one point to resemble the shape of the throat of a partially collapsed flexible tube, conveying fluid while being compressed externally. The Reynolds number is 5900. The flow down-str...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345363
更新日期:2001-07-01 00:00:00
abstract:: ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,撤回出版物
doi:10.1007/s11517-018-1933-x
更新日期:2019-03-01 00:00:00
abstract::The tortuosity of retinal blood vessels is an important diagnostic indicator for a number of retinal pathologies. We applied robust quantitative tortuosity metrics, which are well suited to automated detection and measurement, to retinal fluorescein images of normal and diseased vessels exhibiting background diabetic ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0559-4
更新日期:2010-01-01 00:00:00