Abstract:
:Results of self-consistent analyses of cells show the possibility of temperature increases at membranes in response to a single nanosecond, high-voltage pulse, at least over small sections of the membrane. Molecular Dynamics simulations indicate that such a temperature increase could facilitate poration, which is one example of a bio-process at the plasma membrane. Our study thus suggests that the use of repetitive high-intensity voltage pulses could open up possibilities for a host of synergistic bio-responses involving both thermal and electrically driven phenomena.
journal_name
Med Biol Eng Computjournal_title
Medical & biological engineering & computingauthors
Song J,Joshi RP,Schoenbach KHdoi
10.1007/s11517-011-0745-zsubject
Has Abstractpub_date
2011-06-01 00:00:00pages
713-8issue
6eissn
0140-0118issn
1741-0444journal_volume
49pub_type
杂志文章abstract::A bicuspid aortic valve (BAV) is a congenital cardiac disorder where the valve consists of only two cusps instead of three, as in a normal tricuspid valve (TAV). Although 97 % of BAVs include asymmetric cusps, little or no prior studies have investigated the blood flow through a three-dimensional BAV and root. The aim...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-013-1055-4
更新日期:2013-08-01 00:00:00
abstract::To make picture archiving and communication systems (PACS) a practical reality for small-scale structures, it appears necessary to build a network that integrates and optimises production management, analysis and storage of images, and to include the ability to communicate with other similar remote structures. To solv...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02458046
更新日期:1993-05-01 00:00:00
abstract::Protein glycosylation is one of the most important and complex post-translational modification that provides greater proteomic diversity than any other post-translational modification. Fast and reliable computational methods to identify glycosylation sites are in great demand. Two key issues, feature encoding and feat...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1268-9
更新日期:2015-06-01 00:00:00
abstract::A compression algorithm for electrocardiogram signals is presented, based on an auto-associative neural network. Issues of weight and activation coding are considered, and compression performances of various network sizes are compared. A unique feature is the performance improvement achieved using DC level removal. A ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02523019
更新日期:1995-11-01 00:00:00
abstract::A new system capable of generating static and dynamic random-element stereograms is designed and implemented. The stereogram is composed of a rectangle that can be varied in size, element density, orientation, and horizontal and vertical disparities, and can be swept at several velocities. The system is based on an in...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02524687
更新日期:1994-07-01 00:00:00
abstract::Recent studies were investigated that report spontaneous oscillations of cerebral perfusion in the very low-frequency range (0.01-0.04 Hz), emphasising details of spectral estimation. The effects of different spectral estimation procedures were compared, using simulated and clinical data. It was shown that data detren...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02343541
更新日期:2003-01-01 00:00:00
abstract::Selective laser sintering (SLS) is a solid freeform fabrication technique, developed by Carl Deckard for his master's thesis at the University of Texas, patented in 1989. SLS manufacturing is a technique that produces physical models through a selective solidification of a variety of fine powders. SLS technology is ge...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-012-1001-x
更新日期:2013-03-01 00:00:00
abstract::Increasing costs in healthcare have stimulated discussions on whether installation of competent in-house service groups for equipment management could eventually aid in reducing expenditure. In the Federal Republic of Germany, a four-year programme was initiated in 1979 with the purpose of investigating the feasibilit...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02442172
更新日期:1989-01-01 00:00:00
abstract::Reactive hyperaemia is the term given to the temporary increase in blood flow that follows release of an occlusion of the arterial supply. Measurement of reactive hyperaemia in the leg below the knee is useful in assessment of the vascular system, as resting flows remain unaffected even in the presence of quite severe...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02515312
更新日期:1994-09-01 00:00:00
abstract::The aim of the study was to assess the wavelength dependence of the UV absorbance during monitoring of different compounds in the dialysate. UV absorbance was determined by using a double-beam spectrophotometer on dialysate samples taken at pre-determined times during dialysis, over a wavelength range of 180-380 nm. C...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02348430
更新日期:2003-05-01 00:00:00
abstract::A technique is proposed that allows automatic decomposition of electromyographic (EMG) signals into their constituent motor unit action potential trains (MUAPTs). A specific iterative algorithm with a classification method using fuzzy-logic techniques was developed. The proposed classification method takes into accoun...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02349972
更新日期:2003-11-01 00:00:00
abstract::The software system GASepo has been developed as a tool to visualise and analyse doping (searching for performance-enhancing drugs in sports) with recombinant erythropoietin (rEpo). Digital images derived from the separation of Epo isoforms in gels by iso-electric focusing followed by double blotting and chemiluminesc...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345819
更新日期:2005-05-01 00:00:00
abstract::A method is presented for automatic analysis of the P-wave, based on lead II of a 12-lead standard ECG, in resting conditions during a routine examination for the detection of patients prone to atrial fibrillation (AF), one of the most prevalent arrhythmias. First, the P-wave was delineated, and this was achieved in t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02347697
更新日期:2002-01-01 00:00:00
abstract::Pain control in conscious patients was investigated using a push-button, demand-driven supply of drugs. A fuzzy logic patient-controlled analgesia (PCA) algorithm was compared with a conventional algorithm, for alfentanil administration in extracorporeal shock-wave lithotripsy. The conventional PCA algorithm used an i...
journal_title:Medical & biological engineering & computing
pub_type: 临床试验,杂志文章
doi:10.1007/BF02347706
更新日期:2002-01-01 00:00:00
abstract::In this paper, delivery devices for nanosecond pulsed electric field exposure of biological samples in direct contact with electrodes or isolated are presented and characterized. They are based on a modified electroporation cuvette and two transverse electromagnetic cells (TEM cells). The devices were used to apply pu...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-017-1676-0
更新日期:2018-01-01 00:00:00
abstract::The purpose of this study is to verify the applicability of a sixth-order model to the mechanomyogram (MMG) system of the parallel-fibered muscle, which was identified from the MMG of the pennation muscle. The median nerve was stimulated, and an MMG and torque of the abductor pollicis brevis muscle were measured. The ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-013-1107-9
更新日期:2013-12-01 00:00:00
abstract::The aim of this study was to analyse the trends of the first three power spectral moments of the mechanomyogram (MMG) signal recorded by a microphone (MMG(MIC)) and an accelerometer (MMG(ACC)) during sustained contractions. MMG signals were recorded from the biceps brachii muscle in 14 healthy male subjects during a 3...
journal_title:Medical & biological engineering & computing
pub_type: 临床试验,杂志文章
doi:10.1007/s11517-006-0036-2
更新日期:2006-04-01 00:00:00
abstract::Monitoring upper-limb activity in a free-living environment is important for the evaluation of rehabilitation. This study is a validation of the Strathclyde Upper-Limb Activity Monitor (SULAM) which records the vertical movement and position of each wrist, and assesses bimanual movement. Agreement between the SULAM an...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-007-0233-7
更新日期:2007-10-01 00:00:00
abstract::This article presents model predictive controllers (MPCs) and multi-parametric model-based controllers for delivery of anaesthetic agents. The MPC can take into account constraints on drug delivery rates and state of the patient but requires solving an optimization problem at regular time intervals. The multi-parametr...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-010-0604-3
更新日期:2010-06-01 00:00:00
abstract::The problem of excess cerebrospinal fluid in the brain (hydrocephalus) is generally managed using a passive pressure or flow regulated mechanical shunt. Despite the success of such devices, they have been plagued with a number of problems. It is desirable to have a shunt valve that responds dynamically to the changing...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-010-0716-9
更新日期:2011-01-01 00:00:00
abstract::Instrumentation to measure accurately the stresses at the interface of a residual limb and prosthetic socket has a strong potential for use in prosthetic treatment. As a tool in the clinical setting, the device would allow a clinician to identify sites of excessive loading, information which could then be combined wit...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/BF02522507
更新日期:1995-07-01 00:00:00
abstract::In cranioplasty, neurosurgeons use bone grafts to repair skull defects. To ensure the protection of intracranial tissues and recover the original head shape for aesthetic purposes, a custom-made pre-fabricated prosthesis must match the cranial incision as closely as possible. In our previous study (Liao et al. in Med ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-0972-y
更新日期:2013-02-01 00:00:00
abstract::Aortic stiffness measurement is well recognized as an independent predictor of cardiovascular mortality and morbidity. Recently, a simple method has been proposed for the evaluation of the local aortic stiffness (AoStiff) using a non-invasive bioelectrical impedance (BI) technique. This approach relies on a novel inte...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-011-0741-3
更新日期:2011-04-01 00:00:00
abstract::Proper alignment of acetabular implantation is necessary for good patient outcomes and preventing complications or additional surgeries in total hip arthroplasty (THA). Rotation of the pelvis in lateral decubitus (LD) is typically not accounted for as surgeons use the surgery table as a reference plane to align implan...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-020-02235-4
更新日期:2020-10-01 00:00:00
abstract::Self-generated mobility is a major contributor to the physical, emotional, cognitive, and social development of infants and toddlers. When young children have disorders that hinder self locomotion, their development is at risk for delay. Independent mobility via traditional power mobility devices may prevent this dela...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-011-0820-5
更新日期:2011-10-01 00:00:00
abstract::Time-varying filtering techniques are applied to the problem of baseline correction by letting the cut-off frequency of a linear filter be controlled by the low-frequency properties of the ECG signal. The time-varying filter is implemented as a bank of linear low-pass filters, in which each filter has a slightly diffe...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02441986
更新日期:1993-09-01 00:00:00
abstract::Disappointing results for total ankle replacement have been explained by poor knowledge of the mechanics of the intact and replaced joints. Dynamic simulation tools have the capacity to simulate dynamic conditions that occur in human joints. The Working Model 2D tool was used to simulate the mechanics of the intact an...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02348124
更新日期:2002-03-01 00:00:00
abstract::In common radiography, image contrast is often limited due mainly to scattered x-rays and noise, decreasing the quantitative usefulness of x-ray images. Several scatter reduction methods based on software correction schemes have been extensively investigated in an attempt to overcome these difficulties, most of which ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-018-1893-1
更新日期:2019-02-01 00:00:00
abstract::The accelerometer is used for mechanomyogram (MMG) recordings of muscle contractions. Although the mechanical characteristics of other MMG transducers have been determined with reference to the accelerometer, mechanical aspects of the accelerometer itself, including the weight of the transducer, have not been verified...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344888
更新日期:2003-03-01 00:00:00
abstract::The mechanism of brain contusion has been investigated using a series of three-dimensional (3D) finite element analyses. A head injury model was used to simulate forward and backward rotation around the upper cervical vertebra. Intracranial pressure and shear stress responses were calculated and compared. The results ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02347044
更新日期:2000-05-01 00:00:00