System identification of evoked mechanomyogram from abductor pollicis brevis muscle in isometric contraction.

Abstract:

:The purpose of this study is to verify the applicability of a sixth-order model to the mechanomyogram (MMG) system of the parallel-fibered muscle, which was identified from the MMG of the pennation muscle. The median nerve was stimulated, and an MMG and torque of the abductor pollicis brevis muscle were measured. The MMGs were detected with either a capacitor microphone or an acceleration sensor. The transfer functions between stimulation and the MMG and between stimulation and torque were identified by the singular value decomposition method. The torque and the MMG, which were detected with a capacitor microphone, DMMG, were approximated with a second- and a third-order model, respectively. The natural frequency of the torque, reflecting longitudinal mechanical characteristics, did not show a significant difference from that of the DMMG. The MMG detected with an acceleration sensor was approximated with a fourth-order model. The natural frequencies of the AMMG reflecting the muscle and subcutaneous tissue in the transverse direction were obtained. Both DMMG and AMMG have to be measured to investigate the model of the MMG system for parallel-fibered muscle. The MMG system of parallel-fibered muscle was also modeled with a sixth-order model.

journal_name

Med Biol Eng Comput

authors

Uchiyama T,Sakai H

doi

10.1007/s11517-013-1107-9

subject

Has Abstract

pub_date

2013-12-01 00:00:00

pages

1349-55

issue

12

eissn

0140-0118

issn

1741-0444

journal_volume

51

pub_type

杂志文章
  • OKAS-3D: optoelectronic jaw movement recording system with six degrees of freedom.

    abstract::OKAS-3D is a further development of the single floating circle target tracker. This tracker consists of a cathode ray tube display, a lens in front of the display and a circular light-sensitive photocell placed in the image field of the lens. A small circular trace generated on the screen is focused around the photoce...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510786

    authors: Naeije M,Van der Weijden JJ,Megens CC

    更新日期:1995-09-01 00:00:00

  • Computerised analysis of auscultatory sounds associated with vascular patency of haemodialysis access.

    abstract::Vascular access for renal dialysis is a lifeline for about 120 000 individuals in the United States. Stethoscope auscultation of vascular sounds has some utility in the assessment of access patency, yet can be highly skill-dependent. The objective of the study was to identify acoustic parameters that are related to ch...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345123

    authors: Mansy HA,Hoxie SJ,Patel NH,Sandler RH

    更新日期:2005-01-01 00:00:00

  • CSF dynamic analysis of a predictive pulsatility-based infusion test for normal pressure hydrocephalus.

    abstract::Disturbed cerebrospinal fluid (CSF) dynamics are part of the pathophysiology of normal pressure hydrocephalus (NPH) and can be modified and treated with shunt surgery. This study investigated the contribution of established CSF dynamic parameters to AMP(mean), a prognostic variable defined as mean amplitude of cardiac...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1110-1

    authors: Qvarlander S,Malm J,Eklund A

    更新日期:2014-01-01 00:00:00

  • Quantitative assessment of lower limbs gross motor function in children with cerebral palsy based on surface EMG and inertial sensors.

    abstract::Taking advantage of motion sensing technology, a quantitative assessment method for lower limbs motor function of cerebral palsy (CP) based on the gross motor function measurement (GMFM)-24 scale was explored in this study. According to the motion analysis on GMFM-24 scale, we translated the assessment problem of GMFM...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02076-w

    authors: Chen X,Wu Q,Tang L,Cao S,Zhang X,Chen X

    更新日期:2020-01-01 00:00:00

  • A novel finite element model-based navigation system-supported workflow for breast tumor excision.

    abstract::In the case of female breast cancer, a breast-conserving excision is often desirable. This surgery is based on preoperatively gathered MRI, mammography, and sonography images. These images are recorded in multiple patient positions, e. g., 2D mammography images in standing position with a compressed breast and 3D MRI ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01977-0

    authors: Esslinger D,Rapp P,Knödler L,Preibsch H,Tarín C,Sawodny O,Brucker SY,Hahn M

    更新日期:2019-07-01 00:00:00

  • Transient phase locking patterns among respiration, heart rate and blood pressure during cardiorespiratory synchronisation in humans.

    abstract::The interactions between respiration, heart rate and blood pressure variability (HRV, BPV), are considered to be of paramount importance for the study of the functional organisation of the autonomic nervous system (ANS). The aim of the reported study is to detect and classify the intermittent phase locking (PL) phenom...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345011

    authors: Censi F,Calcagnini G,Lino S,Seydnejad SR,Kitney RI,Cerutti S

    更新日期:2000-07-01 00:00:00

  • Gabor filters and phase portraits for the detection of architectural distortion in mammograms.

    abstract::Architectural distortion is a subtle abnormality in mammograms, and a source of overlooking errors by radiologists. Computer-aided diagnosis (CAD) techniques can improve the performance of radiologists in detecting masses and calcifications; however, most CAD systems have not been designed to detect architectural dist...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0088-3

    authors: Rangayyan RM,Ayres FJ

    更新日期:2006-10-01 00:00:00

  • Left-ventricular pressure gradients: a computer-model simulation.

    abstract::Both invasive left-ventricular pressure measurements and non-invasive colour M-mode echographic measurements have shown the existence of intraventricular pressure gradients (IVPGs) during early filling. The mechanisms responsible for these IVPG cannot be completely explained by the experiments. Therefore a one-dimensi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513338

    authors: Verdonck P,Vierendeels J,Riemslagh K,Dick E

    更新日期:1999-07-01 00:00:00

  • A non-invasive method to predict electrical cardioversion outcome of persistent atrial fibrillation.

    abstract::Atrial fibrillation (AF) is the most common cardiac arrhythmia with episodes that may terminate spontaneously in the first stages of the disease. On the other hand, when the arrhythmia is not self-terminating, normal sinus rhythm (NSR) restoration use to be required to reduce the risk of stroke and improve cardiac out...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0348-5

    authors: Alcaraz R,Rieta JJ

    更新日期:2008-07-01 00:00:00

  • Analysis of macro- and microstructures of normal and pathological tissues by ultrasonic backscattering techniques.

    abstract::A technique to obtain the spacing distribution of macro- and microstructures of hypercholestrolemic liver, lymphoidlucosed liver, rhinosporidium of man and ethmoidal tumour of bovine is presented. The method uses signal processing of spatially averaged spectra of ultrasonic backscattering from tissues in the frequency...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02442608

    authors: Swarnamani S,Singh M

    更新日期:1990-11-01 00:00:00

  • Application of mechanical mobility of periodontal tissues to tooth mobility examination.

    abstract::Tooth mobility examination is important in planning dental treatment, as it may give an indication of alveolar bone loss and the condition of the periodontal ligament. In clinical dental diagnosis a manual tooth mobility examination is useful. However, its determination of tooth mobility is subjective and depends on t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02442173

    authors: Oka H,Yamamoto T,Saratani K,Kawazoe T

    更新日期:1989-01-01 00:00:00

  • A cepstrum analysis-based classification method for hand movement surface EMG signals.

    abstract::It is of great importance to effectively process and interpret surface electromyogram (sEMG) signals to actuate a robotic and prosthetic exoskeleton hand needed by hand amputees. In this paper, we have proposed a cepstrum analysis-based method for classification of basic hand movement sEMG signals. Cepstral analysis t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02024-8

    authors: Yavuz E,Eyupoglu C

    更新日期:2019-10-01 00:00:00

  • A computer-assisted human peripheral blood leukocyte image classification method based on Siamese network.

    abstract::A computer-assisted human peripheral blood leukocyte image classification method based on Siamese network is proposed. Firstly, a Siamese network with two identical convolutional neural network (CNN) sub-networks and a logistic regression for leukocyte five classification is designed, which can learn not only distingu...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02180-2

    authors: Wang Y,Cao Y

    更新日期:2020-07-01 00:00:00

  • Modelling and multi-parametric control for delivery of anaesthetic agents.

    abstract::This article presents model predictive controllers (MPCs) and multi-parametric model-based controllers for delivery of anaesthetic agents. The MPC can take into account constraints on drug delivery rates and state of the patient but requires solving an optimization problem at regular time intervals. The multi-parametr...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0604-3

    authors: Dua P,Dua V,Pistikopoulos EN

    更新日期:2010-06-01 00:00:00

  • Regulation of neurofilament interactions in vitro by natural and synthetic polypeptides sharing Lys-Ser-Pro sequences with the heavy neurofilament subunit NF-H: neurofilament crossbridging by antiparallel sidearm overlapping.

    abstract::Neurofilaments are organised into parallel bundles in axons through crossbridges formed by lateral projections of neurofilament subunits. Pure neurofilaments form gels in vitro, consisting of interconnected parallel arrays of filaments regulated by the phosphorylation level of neurofilament subunits. Neurofilament-ass...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02522486

    authors: Gou JP,Gotow T,Janmey PA,Leterrier JF

    更新日期:1998-05-01 00:00:00

  • Apnea bradycardia detection based on new coupled hidden semi Markov model.

    abstract::In this paper, a method for apnea bradycardia detection in preterm infants is presented based on coupled hidden semi Markov model (CHSMM). CHSMM is a generalization of hidden Markov models (HMM) used for modeling mutual interactions among different observations of a stochastic process through using finite number of hi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02277-8

    authors: Montazeri Ghahjaverestan N,Shamsollahi MB,Ge D,Beuchée A,Hernández AI

    更新日期:2021-01-01 00:00:00

  • French legal framework relating to human tissues and cells.

    abstract::Thousands of patients receive human tissue grafts every year. Developments in cell and tissue engineering have also increased considerably the number of available products of human origin. France has very strict regulations, in part stimulated by problems of public health and ethics that have emerged in recent years a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344783

    authors: Pascal P,Damour O,Colpart JJ,Braye F

    更新日期:2000-03-01 00:00:00

  • Dynamics of magnetic particles in cylindrical Halbach array: implications for magnetic cell separation and drug targeting.

    abstract::Magnetic nanoparticles for therapy and diagnosis are at the leading edge of the rapidly developing field of bionanotechnology. In this study, we have theoretically studied motion of magnetic nano- as well as micro-particles in the field of cylindrical Halbach array of permanent magnets. Magnetic flux density was model...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0636-8

    authors: Babinec P,Krafcík A,Babincová M,Rosenecker J

    更新日期:2010-08-01 00:00:00

  • Continuous monitoring of upper-limb activity in a free-living environment: a validation study.

    abstract::Monitoring upper-limb activity in a free-living environment is important for the evaluation of rehabilitation. This study is a validation of the Strathclyde Upper-Limb Activity Monitor (SULAM) which records the vertical movement and position of each wrist, and assesses bimanual movement. Agreement between the SULAM an...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0233-7

    authors: Vega-Gonzalez A,Bain BJ,Dall PM,Granat MH

    更新日期:2007-10-01 00:00:00

  • Analysis of the O-wave in acute right ventricular apex impedance measurements with a standard pacing lead in animals.

    abstract::Modern pacemakers (implantable devices used for maintaining an appropriate heart rate in patients) can use an intracardiac ventricular impedance signal for physiological cardiac stimulation control. Intracardiac ventricular impedance from nine animal subjects is analysed and presented (seven sheep: 49.0 +/- 6.5 kg, si...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345448

    authors: Järverud K,Ollmar S,Brodin LA

    更新日期:2002-09-01 00:00:00

  • Statistical processing for gastric slow-wave identification.

    abstract::Successful identification of gastric slow waves in canine gastric electrical activity (GEA) data was achieved using a statistical data-processing procedure based on the multiple linear regression (MLR) curve fitting technique. Both distal and proximal waveforms were identified, first by construction of separate orthon...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345076

    authors: Grant MS,Williams RD

    更新日期:2002-07-01 00:00:00

  • Motorised resection device for transurethral resection of the prostate: a laboratory evaluation.

    abstract::Transurethral resection of the prostate is the most common method of relieving urinary outflow obstruction secondary to prostatic enlargement. However, this procedure can be responsible for various complications, including irrigant-fluid absorption and blood loss, both of which are strongly dependent on operation dura...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510962

    authors: Mestas JL,Cathignol D,Chavrier F,Devonec M

    更新日期:1997-11-01 00:00:00

  • Rheological modelling of leukocytes.

    abstract::A three-layer Newtonian model is investigated using a combined Eulerian-Lagrangian computational method to describe the dynamic behaviour of leukocytes. The model, composed of a cell membrane (outer layer), cytoplasm (middle layer) and nucleus (inner layer), can better describe the recovery characteristics because lar...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510753

    authors: Tran-Son-Tay R,Kan HC,Udaykumar HS,Damay E,Shyy W

    更新日期:1998-03-01 00:00:00

  • Optimal chest compression in cardiopulmonary resuscitation depends upon thoracic and back support stiffness.

    abstract::A biomechanical analysis of the constant peak displacement and constant peak force methods of cardiopulmonary resuscitation (CPR) has revealed that optimal CC performance strongly depends on back support stiffness, CC rate, and the thoracic stiffness of the patient being resuscitated. Clinically the results presented ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0963-z

    authors: Dellimore KH,Scheffer C

    更新日期:2012-12-01 00:00:00

  • Improved performance of intravascular pO2 sensor incorporating poly(MPC-co-BMA) membrane.

    abstract::The first in vivo evaluation of a pO2 sensor constructed with a novel copolymer is described. The performance of the sensor is assessed under dynamic conditions in vitro and in vivo. This sensor is more stable and reliable than the control sensor with a heparin-treated polyethylene membrane. ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02511245

    authors: Zhang S,Wright G,Kingston MA,Rolfe P

    更新日期:1996-07-01 00:00:00

  • Repolarization variability independent of heart rate during sympathetic activation elicited by head-up tilt.

    abstract::The fraction of repolarization variability independent of RR interval variability is of clinical interest. It has been linked to direct autonomic nervous system (ANS) regulation of the ventricles in healthy subjects and seems to reflect the instability of the ventricular repolarization process in heart disease. In thi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01998-9

    authors: El-Hamad F,Javorka M,Czippelova B,Krohova J,Turianikova Z,Porta A,Baumert M

    更新日期:2019-08-01 00:00:00

  • New method using multi-regression analysis on evoked electromyography during movement to adjust stimulation conditions.

    abstract::A new method of stimulation of the lower extremities was devised that automatically adjusts the stimulation conditions at any angle of the knee joint. An M-wave is considered to indicate the stimulation conditions, because it is the waveform that results from direct stimulation to the axon of the alpha motor neuron. T...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02351018

    authors: Tanabe S,Muraoka Y,Tomita Y

    更新日期:2004-01-01 00:00:00

  • Effect of mains interference on time coherent averaging.

    abstract::The paper deals with the influence of mains interference on time coherent averaging using an internal trigger. The general distribution of the time jitter is derived and applied to a simplified signal. The authors prove that no amount of averaging can do away with this type of interference. Finally, the deformation th...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02457827

    authors: Strackee J,Peper A

    更新日期:1992-09-01 00:00:00

  • Clinically oriented real-time monitoring of the individual's risk for deep tissue injury.

    abstract::Spinal cord injury patients are under daily risk for developing deep tissue injury which is a severe pressure ulcer that initiates in soft tissues at the bones' proximity. We aimed to formulate a patient-specific biomechanical model that can continuously monitor internal tissue stresses in real time. We adopted a form...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0754-y

    authors: Portnoy S,Vuillerme N,Payan Y,Gefen A

    更新日期:2011-04-01 00:00:00

  • Evaluation of range of motion restriction within the hip joint.

    abstract::In total hip arthroplasty, determining the impingement free range of motion requirement is a complex task. This is because in the native hip, motion is restricted by both impingement as well as soft tissue restraint. The aim of this study is to determine a range of motion benchmark which can identify motions which are...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-1016-3

    authors: Turley GA,Williams MA,Wellings RM,Griffin DR

    更新日期:2013-04-01 00:00:00