A non-invasive method to predict electrical cardioversion outcome of persistent atrial fibrillation.

Abstract:

:Atrial fibrillation (AF) is the most common cardiac arrhythmia with episodes that may terminate spontaneously in the first stages of the disease. On the other hand, when the arrhythmia is not self-terminating, normal sinus rhythm (NSR) restoration use to be required to reduce the risk of stroke and improve cardiac output. Electrical cardioversion (ECV) is the most effective alternative to revert AF back to sinus rhythm. However, because of its collateral effects and the high risk of AF recurrence, it is clinically important to predict NSR maintenance after ECV before it is attempted. This work presents a non-invasive method able to predict the ECV outcome of persistent AF. In this respect, the atrial activity (AA) organization degree has been computed, both in time and wavelet domains, using a non-linear regularity index, such as sample entropy (SampEn). The main hypothesis considers that AF recurrence can be greater in those patients who present a more disorganized AA. Considering only the time-domain organization analysis, 90% (19 out of 21) sensitivity and 79% (11 out of 14) specificity was obtained, whereas, with only the wavelet-domain organization analysis, 81% (17 out of 21) sensitivity and 86% (12 out of 14) specificity was reported. By combining suitably both organization strategies, 95% (20 out of 21) sensitivity and 93% (13 out of 14) specificity was obtained and the ECV outcome in 33 out of 35 patients (94%) was correctly predicted. These results show that the proposed AA organization schemes and their suitable combination are promising candidates for predicting successful cardioversion and NSR maintenance following ECV in persistent AF patients. Nevertheless, further studies employing larger ECV databases are required to provide confidence and reliability to these methods.

journal_name

Med Biol Eng Comput

authors

Alcaraz R,Rieta JJ

doi

10.1007/s11517-008-0348-5

subject

Has Abstract

pub_date

2008-07-01 00:00:00

pages

625-35

issue

7

eissn

0140-0118

issn

1741-0444

journal_volume

46

pub_type

杂志文章
  • Using three-dimensional multigrid-based snake and multiresolution image registration for reconstruction of cranial defect.

    abstract::In cranioplasty, neurosurgeons use bone grafts to repair skull defects. To ensure the protection of intracranial tissues and recover the original head shape for aesthetic purposes, a custom-made pre-fabricated prosthesis must match the cranial incision as closely as possible. In our previous study (Liao et al. in Med ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0972-y

    authors: Liao YL,Lu CF,Wu CT,Lee JD,Lee ST,Sun YN,Wu YT

    更新日期:2013-02-01 00:00:00

  • Time-frequency analysis of heart murmurs. Part I: Parametric modelling and numerical simulations.

    abstract::The object of this study is to compare the performance of two new bilinear time-frequency representation techniques with the spectrogram to characterise the behaviour of heart murmurs produced by bioprosthetic heart valves implanted in the mitral or aortic position. The murmurs are those of mitral stenosis, mitral reg...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02525526

    authors: Debiais F,Durand LG,Pibarot P,Guardo R

    更新日期:1997-09-01 00:00:00

  • Intraoperative acceleration measurements to quantify improvement in tremor during deep brain stimulation surgery.

    abstract::Deep brain stimulation (DBS) surgery is extensively used in the treatment of movement disorders. Nevertheless, methods to evaluate the clinical response during intraoperative stimulation tests to identify the optimal position for the implantation of the chronic DBS lead remain subjective. In this paper, we describe a ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1559-9

    authors: Shah A,Coste J,Lemaire JJ,Taub E,Schüpbach WMM,Pollo C,Schkommodau E,Guzman R,Hemm-Ode S

    更新日期:2017-05-01 00:00:00

  • Continuous monitoring of upper-limb activity in a free-living environment: a validation study.

    abstract::Monitoring upper-limb activity in a free-living environment is important for the evaluation of rehabilitation. This study is a validation of the Strathclyde Upper-Limb Activity Monitor (SULAM) which records the vertical movement and position of each wrist, and assesses bimanual movement. Agreement between the SULAM an...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0233-7

    authors: Vega-Gonzalez A,Bain BJ,Dall PM,Granat MH

    更新日期:2007-10-01 00:00:00

  • Computational wrist analysis of functional restoration after scapholunate dissociation repair.

    abstract::The scapholunate ligament stabilizes the scaphoid and lunate of the proximal row in the wrist which allows for proper force transmission with the radius and ulna. Damage to this structure degenerates into arthritis and disability. Controversy exists over the best technique to restore function and reduce pain. A three-...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01971-6

    authors: Wayne JS,Tremols EJ

    更新日期:2019-07-01 00:00:00

  • Extracellular volume measurements using bioimpedance spectroscopy-Hanai method and wrist-ankle resistance at 50 kHz.

    abstract::A method for extrapolating the extracellular water (ECW) resistance from wrist-ankle resistance at 50 kHz (R (50)) is proposed in this paper, in order to enable 50 kHz impedancemeters to use the BIS-Hanai equation for determination of ECW. Values of R (50) and the ECW resistance extrapolated at zero frequency R (e) we...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0394-z

    authors: Jaffrin MY,Morel H

    更新日期:2009-01-01 00:00:00

  • Contact mechanics of a thin-walled capsule adhered onto a rigid planar substrate.

    abstract::A thin-walled capsule, modelled as an incompressible liquid droplet contained in a thin flexible membrane, was allowed to adhere onto a rigid substrate. The contact mechanics were formulated, based on linear elasticity, to portray quantitatively the relationships between osmotic inflation, contact area and angle, memb...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345154

    authors: Wan KT,Liu KK

    更新日期:2001-09-01 00:00:00

  • Inhibition of TNF-alpha induced cell death in human umbilical vein endothelial cells and Jurkat cells by protocatechuic acid.

    abstract::The Chinese herb radix Salviae miltiorrhizae (RSM) is used in traditional Chinese medicine as a treatment for cardiovascular and cerebrovascular diseases. Several components of the plant extract from salvia mitorrhiza bunge have been determined previously, one of which is protocatechuic acid (PAC). It has been found, ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345308

    authors: Zhou-Stache J,Buettner R,Artmann G,Mittermayer C,Bosserhoff AK

    更新日期:2002-11-01 00:00:00

  • Evaluation of laser Doppler imaging to measure blood flow in knee ligaments of adult rabbits.

    abstract::Laser Doppler imaging (LDI) is investigated as a novel method for in vivo ligament tissue blood flow determination. LDI output signal is obtained from surgically exposed rabbit medial collateral ligaments (MCL). The LDI signal is compared with simultaneously determined, coloured microsphere (CM)-derived standardised M...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02520078

    authors: Bray R,Forrester K,McDougall JJ,Damji A,Ferrell WR

    更新日期:1996-05-01 00:00:00

  • Arterial reservoir-excess pressure and ventricular work.

    abstract::This study is based on the hypothesis that the pressure within the arterial network can be usefully decomposed as the sum of a reservoir pressure and an excess pressure. The reservoir pressure waveform is defined to be the same in each vessel but delayed by the wave travel time from the root of the aorta. Using calcul...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0872-1

    authors: Parker KH,Alastruey J,Stan GB

    更新日期:2012-04-01 00:00:00

  • Estimation of habituation and signal-to-noise ratio of cortical evoked potentials to oesophageal electrical and mechanical stimulation.

    abstract::Electrical and mechanical stimulation of the oesophagus has been recently proposed to examine the physiological effects of autonomic stimulation in humans. Cortical evoked potentials (EPs) to oesophageal stimulation provide an assessment of afferent fibres and central processing. However, habituation takes place durin...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02534088

    authors: Kamath MV,Tougas G,Hollerbach S,Premji R,Fitzpatrick D,Shine G,Upton AR

    更新日期:1997-07-01 00:00:00

  • The Pocket Speech Aid.

    abstract::A rapid-access but limited vocabulary communication aid for the non-vocal and speech impaired is useful in some well defined situations. The design and construction of such a device is described. Three distinct situations have been identified where an aid is essential and an initial evaluation has shown the Pocket Spe...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441487

    authors: Keating D,Smith DC,Evans AL,Wyper DJ,Cunningham E

    更新日期:1989-05-01 00:00:00

  • Determining appropriate models for joint control using surface electrical stimulation of soleus in spinal cord injury.

    abstract::The mechanical impedance of the ankle joint during electrical stimulation of the soleus is studied by applying constant-velocity 10 degrees angular perturbations to the ankle and measuring the resultant torque. Both neurologically intact subjects and spinal cord injured subjects are tested. Lumped, piecewise linear mo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02512522

    authors: Flaherty B,Robinson C,Agarwal G

    更新日期:1994-05-01 00:00:00

  • Displacement of alveolar macrophages in air space of human lung.

    abstract::The role of alveolar macrophages in the process of the human lung clearance is summarised. Three patterns of alveolar macrophage (AM) displacement on the surface of alveolus are distinguished depending on the loading of the surface with insoluble deposits, i.e. directional, directional with small stochastic noise and ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02522517

    authors: Gradoń L,Podgórski A

    更新日期:1995-07-01 00:00:00

  • Ultrasonic characterization of ultrasound contrast agents.

    abstract::The main constituent of an ultrasound contrast agent (UCA) is gas-filled microbubbles. An average UCA contains billions per ml. These microbubbles are excellent ultrasound scatterers due to their high compressibility. In an ultrasound field they act as resonant systems, resulting in harmonic energy in the backscattere...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0497-1

    authors: de Jong N,Emmer M,van Wamel A,Versluis M

    更新日期:2009-08-01 00:00:00

  • Adaptive processing bandwidth adjustment for laser Doppler flowmetry.

    abstract::A novel laser Doppler flowmetry scheme is reported that adjusts the processing bandwidth adaptively to optimise the estimation of flow. To obtain an adequate processing bandwidth, the Doppler spectra is first fitted to the Lorentzian function, and the bandwidth at half the maximum of the Lorentzian function is used as...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344700

    authors: Chen YY,Lin YH,Jan IC,Liu RS,Chou NK,Jan GJ

    更新日期:2004-05-01 00:00:00

  • Dynamic thermographic imaging method for quantifying dermal perfusion: potential and limitations.

    abstract::A new method of quantifying dermal perfusion on a regional basis using a dynamic thermographic technique is investigated. The technique is based on the relationship between dermal perfusion and the rate of skin surface reheating following the application of a transient cold challenge predicted by a theoretical model. ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441468

    authors: Wilson SB,Spence VA

    更新日期:1989-09-01 00:00:00

  • Finite element analysis of brain contusion: an indirect impact study.

    abstract::The mechanism of brain contusion has been investigated using a series of three-dimensional (3D) finite element analyses. A head injury model was used to simulate forward and backward rotation around the upper cervical vertebra. Intracranial pressure and shear stress responses were calculated and compared. The results ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02347044

    authors: Huang HM,Lee MC,Lee SY,Chiu WT,Pan LC,Chen CT

    更新日期:2000-05-01 00:00:00

  • Hip implant performance prediction by acoustic emission techniques: a review.

    abstract::Nowadays, acoustic emission (AE) has its applications in various areas, including mechanical, civil, underwater acoustics, and biomedical engineering. It is a non-destructive evaluation (NDE) and a non-intrusive method to detect active damage mechanisms such as crack growth, delamination, and processes such as frictio...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-020-02202-z

    authors: Remya AR,Vishwash B,Lee C,Pai PS,Espinoza Oras AA,Ozevin D,Mathew MT

    更新日期:2020-08-01 00:00:00

  • A new method for measurement of motor unit action potential duration based on correlation, a pilot study.

    abstract::We present a new, automatic, correlation-based method for measuring the duration of motor unit action potentials (MUAPs). The method seeks to replicate the way an expert elctromyographer uses his or her eyes, calculating the start and end of the MUAP waveform on the basis of the degree of similarity of non-excluded di...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02115-6

    authors: Rodríguez Carreño I,Malanda A,Gila Useros L,Gurtubay IG,Navallas J,Rodríguez-Falces J

    更新日期:2020-03-01 00:00:00

  • Factors affecting electrode-gel-skin interface impedance in electrical impedance tomography.

    abstract::The magnitude, mismatch and temporal variations of the electrode-gel-skin interface impedance can cause problems in electrical impedance tomography (EIT) measurement. It is shown that at the high frequencies generally encountered in EIT the capacitive properties of the electrode interface, and especially those of the ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/BF02523842

    authors: McAdams ET,Jossinet J,Lackermeier A,Risacher F

    更新日期:1996-11-01 00:00:00

  • Technique for the evaluation of derivatives from noisy biomechanical displacement data using a model-based bandwidth-selection procedure.

    abstract::Smoothing and differentiation of noisy signals are common problems whenever it is difficult or impossible to obtain derivatives by direct measurement. In biomechanics body displacements are frequently assessed and these measurements are affected by noise. To avoid high-frequency noise magnification, data filtering bef...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441963

    authors: D'Amico M,Ferrigno G

    更新日期:1990-09-01 00:00:00

  • Development of a non-invasive treatment system for urinary incontinence using a functional continuous magnetic stimulator (FCMS).

    abstract::A system composed of a functional continuous magnetic stimulator (FCMS) and a saddle-type coil has been developed for non-invasive treatment of urinary incontinence, especially stress incontinence and urge incontinence. The FCMS conditions were as follows: 2 kW maximum electrical power consumption, 800 V maximum capac...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02518872

    authors: Ishikawa N,Suda S,Sasaki T,Yamanishi T,Hosaka H,Yasuda K,Ito H

    更新日期:1998-11-01 00:00:00

  • Application of mechanical mobility of periodontal tissues to tooth mobility examination.

    abstract::Tooth mobility examination is important in planning dental treatment, as it may give an indication of alveolar bone loss and the condition of the periodontal ligament. In clinical dental diagnosis a manual tooth mobility examination is useful. However, its determination of tooth mobility is subjective and depends on t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02442173

    authors: Oka H,Yamamoto T,Saratani K,Kawazoe T

    更新日期:1989-01-01 00:00:00

  • Measurements of steady turbulent flow through a rigid simulated collapsed tube.

    abstract::Axial and transverse components of liquid velocity are measured by laser Doppler anemometer in a perspex tube that has been deformed at one point to resemble the shape of the throat of a partially collapsed flexible tube, conveying fluid while being compressed externally. The Reynolds number is 5900. The flow down-str...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345363

    authors: Bertram CD,Muller M,Ramus F,Nugent AH

    更新日期:2001-07-01 00:00:00

  • Detection of the third heart sound using a tailored wavelet approach: method verification.

    abstract::Heart sounds can be considered as mechanical fingerprints of myocardial function. The third heart sound normally occurs in children but disappears with maturation. The sound can also appear in patients with heart failure. The sound is characterised by its low-amplitude and low-frequency content, which makes it difficu...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345957

    authors: Hult P,Fjällbrant T,Hildén K,Dahlström U,Wranne B,Ask P

    更新日期:2005-03-01 00:00:00

  • System identification of evoked mechanomyogram from abductor pollicis brevis muscle in isometric contraction.

    abstract::The purpose of this study is to verify the applicability of a sixth-order model to the mechanomyogram (MMG) system of the parallel-fibered muscle, which was identified from the MMG of the pennation muscle. The median nerve was stimulated, and an MMG and torque of the abductor pollicis brevis muscle were measured. The ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1107-9

    authors: Uchiyama T,Sakai H

    更新日期:2013-12-01 00:00:00

  • Pulsatile blood flow in total cavopulmonary connection: a comparison between Y-shaped and T-shaped geometry.

    abstract::Single-ventricle anomaly is a hereditary heart disease that is characterized by anatomical malformations. The main consequence of this malformation is desaturated blood flow, which without proper treatment increases the risk of death. The classical treatment is based on a three-stage palliative procedure which should ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1499-4

    authors: Rajabzadeh-Oghaz H,Firoozabadi B,Saidi MS,Monjezi M,Navabi Shirazi MA,Malakan Rad E

    更新日期:2017-02-01 00:00:00

  • 3D micro-computed tomography of trabecular and cortical bone architecture with application to a rat model of immobilisation osteoporosis.

    abstract::Bone mass and microarchitecture are the main determinants of bone strength. Three-dimensional micro-computed tomography has the potential to examine complete bones of small laboratory animals with very high resolution in a non-invasive way. In the presented work, the proximal part of the tibiae of hindlimb unloaded an...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02347054

    authors: Laib A,Barou O,Vico L,Lafage-Proust MH,Alexandre C,Rügsegger P

    更新日期:2000-05-01 00:00:00

  • Image-based state-of-the-art techniques for the identification and classification of brain diseases: a review.

    abstract::Detection and classification methods have a vital and important role in identifying brain diseases. Timely detection and classification of brain diseases enable an accurate identification and effective management of brain impairment. Brain disorders are commonly most spreadable diseases and the diagnosing process is t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-020-02256-z

    authors: Haq EU,Huang J,Kang L,Haq HU,Zhan T

    更新日期:2020-11-01 00:00:00