Finite element analysis of brain contusion: an indirect impact study.

Abstract:

:The mechanism of brain contusion has been investigated using a series of three-dimensional (3D) finite element analyses. A head injury model was used to simulate forward and backward rotation around the upper cervical vertebra. Intracranial pressure and shear stress responses were calculated and compared. The results obtained with this model support the predictions of cavitation theory that a pressure gradient develops in the brain during indirect impact. Contrecoup pressure-time histories in the parasagittal plane demonstrated that an indirect impact induced a smaller intracranial pressure (-53.7 kPa for backward rotation, and -65.5 kPa for forward rotation) than that caused by a direct impact. In addition, negative pressures induced by indirect impact to the head were not high enough to form cavitation bubbles, which can damage the brain tissue. Simulations predicted that a decrease in skull deformation had a large effect in reducing the intracranial pressure. However, the areas of high shear stress concentration were consistent with those of clinical observations. The findings of this study suggest that shear strain theory appears to better account for the clinical findings in head injury when the head is subjected to an indirect impact.

journal_name

Med Biol Eng Comput

authors

Huang HM,Lee MC,Lee SY,Chiu WT,Pan LC,Chen CT

doi

10.1007/BF02347044

keywords:

subject

Has Abstract

pub_date

2000-05-01 00:00:00

pages

253-9

issue

3

eissn

0140-0118

issn

1741-0444

journal_volume

38

pub_type

杂志文章
  • Use of surface potential spectral characteristics for solving the inverse problem in electroneurography.

    abstract::The changes in the power spectra of single-fibre extracellular action potentials (SFEAPs) generated in an infinite anisotropic frequency-dependent volume conductor, which occurred as a result of alterations in the propagation velocity v and duration T(in) of the intracellular action potential (IAP) were analytically d...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446167

    authors: Dimitrov GV,Lateva ZC,Dimitrova NA

    更新日期:1992-07-01 00:00:00

  • Haemodynamic model of a unilateral iliac stenosis with an aortoiliac bypass.

    abstract::A hydrodynamic model for the part of the human arterial network below the renal arteries has been constructed using specially fabricated distensible tubes and a pulsatile pump to simulate an aortoiliac bypass. The experiments and the computer model indicated that no 'steal' occurred due to the insertion of the bypass ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441802

    authors: Helal MA,Watts KC,Marble AE

    更新日期:1993-11-01 00:00:00

  • DICOM imaging watermarking for hiding medical reports.

    abstract::Medical confidentiality is an essential duty in the medical profession. In this paper, we introduce a novel robust blind watermarking method for securing the medical report in a DICOM (Digital Imaging and Communications in Medicine) imaging. The insertion of each bit is done in the subtraction of adjacent DC coefficie...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02269-8

    authors: Boussif M,Aloui N,Cherif A

    更新日期:2020-11-01 00:00:00

  • PC/VAX or standalone PC-based general purpose biological data collection system.

    abstract::A system, to collect, analyse and display biological data, is developed using IBM PC AT compatibles (PCs) or CED1401/1609 devices networked to a VAX environment. It can be operated in three separate modes: using the CED/IEEE/VAX network; using the PC/Ethernet/VAX network; as a standalone PC. The original system compri...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446881

    authors: Marlow SP,Mackenzie DA,Tomlinson JB

    更新日期:1993-01-01 00:00:00

  • Physiological quality assessment of stored whole blood by means of electrical measurements.

    abstract::The physiological parameters of blood such as extracellular Na(+), K(+), Cl(-), pH, 2,3-DPG and ATP and the complex electrical impedance were measured using whole blood samples from 31 male donors (21 donors form the training set and ten donors were used for testing), on the 0th, 10th and 21st day of blood bank storag...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0206-x

    authors: Ulgen Y,Sezdi M

    更新日期:2007-07-01 00:00:00

  • Classification of the long-QT syndrome based on discriminant analysis of T-wave morphology.

    abstract::The long QT syndrome (LQTS) is a genetic disorder, typically characterized by a prolonged QT interval in the ECG due to abnormal cardiac repolarization. LQTS may lead to syncopal episodes and sudden cardiac death. Various parameters based on T-wave morphology, as well as the QT interval itself have been shown to be us...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0061-1

    authors: Struijk JJ,Kanters JK,Andersen MP,Hardahl T,Graff C,Christiansen M,Toft E

    更新日期:2006-07-01 00:00:00

  • System identification of evoked mechanomyogram from abductor pollicis brevis muscle in isometric contraction.

    abstract::The purpose of this study is to verify the applicability of a sixth-order model to the mechanomyogram (MMG) system of the parallel-fibered muscle, which was identified from the MMG of the pennation muscle. The median nerve was stimulated, and an MMG and torque of the abductor pollicis brevis muscle were measured. The ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1107-9

    authors: Uchiyama T,Sakai H

    更新日期:2013-12-01 00:00:00

  • Parallel conductance determination in cardiac volumetry using dilution manoeuvres: theoretical analysis and practical implications.

    abstract::Left ventricular volume calibration based on the conductance catheter depends on the correct determination of the parallel conductance (Gp). Baan's saline manoeuvre procedure leads to Gp by finding the end-systolic (Ges) and end-diastolic (Ged) conductances, for each beat of the dilution curve rising limb. After plott...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513284

    authors: Herrera MC,Olivera JM,Valentinuzzi ME

    更新日期:1999-03-01 00:00:00

  • Hybrid finite elements and spectral method for computation of the electric potential generated by a nerve cuff electrode.

    abstract::An original numerical method is developed to compute the 3D electric potential generated by a dot-contact cuff electrode implanted around an axisymmetrical, inhomogeneous, anisotropic nerve. The technique is based on a 2D finite-element approach coupled with a semi-analytical Fourier spectral decomposition to approxim...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513375

    authors: Parrini S,Delbeke J,Romero E,Legat V,Veraart C

    更新日期:1999-11-01 00:00:00

  • Method for EMG conduction velocity estimation which accounts for input and output noise.

    abstract::A new technique is derived for estimating the conduction velocity of muscle fibre action potentials from surface EMG recordings in humans. The method is based on system identification and extends previous such methods by explicitly accounting for additive noise at the output as well as at the input. Experimental and s...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446220

    authors: Rababy N,Kearney RE,Hunter IW

    更新日期:1989-03-01 00:00:00

  • Effect of mains interference on time coherent averaging.

    abstract::The paper deals with the influence of mains interference on time coherent averaging using an internal trigger. The general distribution of the time jitter is derived and applied to a simplified signal. The authors prove that no amount of averaging can do away with this type of interference. Finally, the deformation th...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02457827

    authors: Strackee J,Peper A

    更新日期:1992-09-01 00:00:00

  • Optimal chest compression in cardiopulmonary resuscitation depends upon thoracic and back support stiffness.

    abstract::A biomechanical analysis of the constant peak displacement and constant peak force methods of cardiopulmonary resuscitation (CPR) has revealed that optimal CC performance strongly depends on back support stiffness, CC rate, and the thoracic stiffness of the patient being resuscitated. Clinically the results presented ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0963-z

    authors: Dellimore KH,Scheffer C

    更新日期:2012-12-01 00:00:00

  • Measurements of steady turbulent flow through a rigid simulated collapsed tube.

    abstract::Axial and transverse components of liquid velocity are measured by laser Doppler anemometer in a perspex tube that has been deformed at one point to resemble the shape of the throat of a partially collapsed flexible tube, conveying fluid while being compressed externally. The Reynolds number is 5900. The flow down-str...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345363

    authors: Bertram CD,Muller M,Ramus F,Nugent AH

    更新日期:2001-07-01 00:00:00

  • A unified canonical correlation analysis-based framework for removing gradient artifact in concurrent EEG/fMRI recording and motion artifact in walking recording from EEG signal.

    abstract::Artifacts cause distortion and fuzziness in electroencephalographic (EEG) signal and hamper EEG analysis, so it is necessary to remove them prior to the analysis. Particularly, artifact removal becomes a critical issue in experimental protocols with significant inherent recording noise, such as mobile EEG recordings a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1620-3

    authors: Li J,Chen Y,Taya F,Lim J,Wong K,Sun Y,Bezerianos A

    更新日期:2017-09-01 00:00:00

  • Fluid-structure interaction modeling of calcific aortic valve disease using patient-specific three-dimensional calcification scans.

    abstract::Calcific aortic valve disease (CAVD) is characterized by calcification accumulation and thickening of the aortic valve cusps, leading to stenosis. The importance of fluid flow shear stress in the initiation and regulation of CAVD progression is well known and has been studied recently using fluid-structure interaction...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1458-0

    authors: Halevi R,Hamdan A,Marom G,Lavon K,Ben-Zekry S,Raanani E,Bluestein D,Haj-Ali R

    更新日期:2016-11-01 00:00:00

  • Sensitivity of hip tissues contact evaluation to the methods used for estimating the hip joint center of rotation.

    abstract::Computer-based simulations of human hip joints generally include investigating contacts happening among soft or hard tissues during hip movement. In many cases, hip movement is approximated as rotation about an estimated hip center. In this paper, we investigate the effect of different methods used for estimating hip ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0873-0

    authors: Arbabi E,Schmid J,Boulic R,Thalmann D,Magnenat-Thalmann N

    更新日期:2012-06-01 00:00:00

  • Time-varying digital filtering of ECG baseline wander.

    abstract::Time-varying filtering techniques are applied to the problem of baseline correction by letting the cut-off frequency of a linear filter be controlled by the low-frequency properties of the ECG signal. The time-varying filter is implemented as a bank of linear low-pass filters, in which each filter has a slightly diffe...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441986

    authors: Sörnmo L

    更新日期:1993-09-01 00:00:00

  • Continuous monitoring of upper-limb activity in a free-living environment: a validation study.

    abstract::Monitoring upper-limb activity in a free-living environment is important for the evaluation of rehabilitation. This study is a validation of the Strathclyde Upper-Limb Activity Monitor (SULAM) which records the vertical movement and position of each wrist, and assesses bimanual movement. Agreement between the SULAM an...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0233-7

    authors: Vega-Gonzalez A,Bain BJ,Dall PM,Granat MH

    更新日期:2007-10-01 00:00:00

  • Foetal heart rate power spectrum response to uterine contraction.

    abstract::Cardiotocography is the most diffused prenatal diagnostic technique in clinical routine. The simultaneous recording of foetal heart rate (FHR) and uterine contractions (UC) provides useful information about foetal well-being during pregnancy and labour. However, foetal electronic monitoring interpretation still lacks ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0022-8

    authors: Romano M,Bifulco P,Cesarelli M,Sansone M,Bracale M

    更新日期:2006-03-01 00:00:00

  • Improvement of wireless power transmission efficiency of implantable subcutaneous devices by closed magnetic circuit mechanism.

    abstract::Induction coils were fabricated based on flexible printed circuit board for inductive transcutaneous power transmission. The coil had closed magnetic circuit (CMC) structure consisting of inner and outer magnetic core. The power transmission efficiency of the fabricated device was measured in the air and in vivo condi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0939-z

    authors: Jo SE,Joung S,Suh JK,Kim YJ

    更新日期:2012-09-01 00:00:00

  • Radial strain assessment of the interventricular septum wall by a new technique in healthy subjects.

    abstract::The aim of this study was to design a new approach for the acquisition of regional radial strain from the middle portion of the interventricular septum. We designed and wrote a program in Matlab (computer-assisted method) for use on a personal computer so that the septum thickness throughout the cardiac cycle could be...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0222-x

    authors: Moladoust H,Mokhtari-Dizaji M,Ojaghi-Haghighi Z,D'hooge J,Noohi F,Khaledifar A,Khajavi A

    更新日期:2007-09-01 00:00:00

  • Real-time human motion estimation using biomechanical models and non-linear state-space filters.

    abstract::In the field of sports biomechanics and rehabilitation engineering, the possibility of computing, in real time, the angular displacements and derivatives of human joints, from a video of motion sequences, represents an appealing goal. In particular, applications of biofeedback protocols in rehabilitation can benefit f...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344878

    authors: Cerveri P,Rabuffetti M,Pedotti A,Ferrigno G

    更新日期:2003-03-01 00:00:00

  • Cumulant-based trapezoidal basis selection for heart sound classification.

    abstract::Past decades witnessed the expansion of linear signal processing methods in numerous biomedical applications. However, the nonlinear behavior of biomedical signals revived the interest in nonlinear signal processing methods such as higher-order statistics, in particular higher-order cumulants (HOC). In this paper, HOC...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1394-4

    authors: Safara F

    更新日期:2015-11-01 00:00:00

  • Relation between branching patterns and perfusion in stochastic generated coronary arterial trees.

    abstract::Biological variation in branching patterns is likely to affect perfusion of tissue. To assess the fundamental consequences of branching characteristics, 50 stochastic asymmetrical coronary trees and one non-stochastic symmetrical branching tree were generated. In the stochastic trees, area growth, A, at branching poin...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0139-9

    authors: Dankelman J,Cornelissen AJ,Lagro J,Vanbavel E,Spaan JA

    更新日期:2007-01-01 00:00:00

  • Evaluation of high resolution thermal imaging to determine the effect of vertebral fractures on associated skin surface temperature in children with osteogenesis imperfecta.

    abstract::Vertebral fractures are common in children with osteogenesis imperfecta (OI). Current imaging methods for fracture detection (X-ray and DXA) use ionising radiation. This pilot study explored whether the alteration in blood flow in vertebral fractures results in skin temperature changes that may be detected using high ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1806-3

    authors: Fane De Salis A,Saatchi R,Dimitri P

    更新日期:2018-09-01 00:00:00

  • A simulation technique for computation of the dosimetric effects of setup, organ motion and delineation uncertainties in radiotherapy.

    abstract::In this study, we introduce a novel simulation technique to incorporate delineation errors into radiotherapy treatment margins and combine them with organ motion and set-up errors to investigate the cumulative dosimetric effects in different tumour sites. The effects of applying patient realignment correction protocol...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0616-z

    authors: Mzenda B,Hosseini-Ashrafi M,Palmer A,Liu H,Brown DJ

    更新日期:2010-07-01 00:00:00

  • Dependence of excitability indices on membrane channel dynamics, myelin impedance, electrode location and stimulus waveforms in myelinated and unmyelinated fibre models.

    abstract::Neuronal excitability is determined in a complex way by several interacting factors, such as membrane dynamics, fibre geometry, electrode configuration, myelin impedance, neuronal terminations[Formula: see text] This study aims to increase understanding in excitability, by investigating the impact of these factors on ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1799-y

    authors: Tarnaud T,Joseph W,Martens L,Tanghe E

    更新日期:2018-09-01 00:00:00

  • Theoretical study of the effect of local flow disturbances on the concentration of low-density lipoproteins at the luminal surface of end-to-end anastomosed vessels.

    abstract::To elucidate the mechanisms of localisation of intimal hyperplasia in anastomosed arteries, the effects of flow disturbances on the transport of low-density lipoproteins (LDLs) from the flowing blood to the wall of end-to-end anastomosed arteries, with and without a moderate stenosis, were studied theoretically by mea...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345458

    authors: Wada S,Koujiya M,Karino T

    更新日期:2002-09-01 00:00:00

  • Inertial measurement units furnish accurate trunk trajectory reconstruction of the sit-to-stand manoeuvre in healthy subjects.

    abstract::A simple inertial measurement unit (IMU) incorporating rate gyroscopes and accelerometers has been tested to investigate the trunk kinematics during the sit-to-stand. It was affixed at trunk L5 level and used for sit-to-stand position and orientation reconstruction. The method was validated with standard optoelectroni...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0224-8

    authors: Giansanti D,Maccioni G,Benvenuti F,Macellari V

    更新日期:2007-10-01 00:00:00

  • Simulation framework for electrophysiological networks: effect of syncytial properties on smooth-muscle synaptic potentials.

    abstract::A building block-based software framework was developed to simulate electrophysiological networks. The synaptic potentials generated during neurotransmission were simulated in an existing discrete bidomain model of smooth muscle, using cubic, three-dimensional grids of varying sizes. The model is automatically derived...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345322

    authors: Turale N,Devulapalli A,Manchanda R,Moudgalya K,Sivakumar G

    更新日期:2003-09-01 00:00:00