Foetal heart rate power spectrum response to uterine contraction.

Abstract:

:Cardiotocography is the most diffused prenatal diagnostic technique in clinical routine. The simultaneous recording of foetal heart rate (FHR) and uterine contractions (UC) provides useful information about foetal well-being during pregnancy and labour. However, foetal electronic monitoring interpretation still lacks reproducibility and objectivity. New methods of interpretation and new parameters can further support physicians' decisions. Besides common time-domain analysis, study of the variability of FHR can potentially reveal autonomic nervous system activity of the foetus. In particular, it is clinically relevant to investigate foetal reactions to UC to diagnose foetal distress early. Uterine contraction being a strong stimulus for the foetus and its autonomic nervous system, it is worth exploring the FHR variability response. This study aims to analyse modifications of the power spectrum of FHR variability corresponding to UC. Cardiotocographic signal tracts corresponding to 127 UC relative to 30 healthy foetuses were analysed. Results mainly show a general, statistically significant (t test, p<0.01) power increase of the FHR variability in the LF 0.03-0.2 Hz and HF 0.2-1 in correspondence of the contraction with respect to a reference tract set before contraction onset. Time evolution of the power within these bands was computed by means of time-varying spectral estimation to concisely show the FHR response along a uterine contraction. A synchronised grand average of these responses was also computed to verify repeatability, using the contraction apex as time reference. Such modifications of the foetal HRV that follow a contraction can be a sign of ANS reaction and, therefore, additional, objective information about foetal reactivity during labour.

journal_name

Med Biol Eng Comput

authors

Romano M,Bifulco P,Cesarelli M,Sansone M,Bracale M

doi

10.1007/s11517-006-0022-8

subject

Has Abstract

pub_date

2006-03-01 00:00:00

pages

188-201

issue

3

eissn

0140-0118

issn

1741-0444

journal_volume

44

pub_type

杂志文章
  • Performance evaluation of ISFETs and other ISE sensors for whole blood ion assay.

    abstract::Performance evaluations of ion-selective field-effect transistors (ISFETs) have been carried out using both quality-control materials and whole arterial blood samples. Comparison of the results from these evaluations suggests that the whole blood evaluation may be more useful when assessing the value of particular sen...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02442678

    authors: Thompson JM

    更新日期:1990-05-01 00:00:00

  • Selective laser sintering in biomedical engineering.

    abstract::Selective laser sintering (SLS) is a solid freeform fabrication technique, developed by Carl Deckard for his master's thesis at the University of Texas, patented in 1989. SLS manufacturing is a technique that produces physical models through a selective solidification of a variety of fine powders. SLS technology is ge...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-012-1001-x

    authors: Mazzoli A

    更新日期:2013-03-01 00:00:00

  • Influence of ionic shifts during dialysis on volume estimations with multifrequency impedance analysis.

    abstract::During dialysis the ion concentrations in many body fluids change significantly. The influence of these changes on the accuracy of volume measurements with bioimpedance spectroscopy is investigated by the following procedure: Plasma ion concentrations and impedance spectra (5-500 kHz) are measured during six standard ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02534137

    authors: Scharfetter H,Wirnsberger GH,Holzer H,Hutten H

    更新日期:1997-03-01 00:00:00

  • Dynamic cerebral autoregulation: different signal processing methods without influence on results and reproducibility.

    abstract::Cerebral autoregulation controls cerebral blood flow under changing cerebral perfusion pressure. Standards for measurement and analysis of dynamic cerebral autoregulation (dCA) are lacking. In this study, dCA reproducibility, quantified by intraclass correlation coefficient, is evaluated for different methodological a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0706-y

    authors: Gommer ED,Shijaku E,Mess WH,Reulen JP

    更新日期:2010-12-01 00:00:00

  • Urinary bladder volume tracking using a Kalman filter.

    abstract::This study introduced the Kalman filter procedure for tracking urinary bladder filling from intermittent bladder volume measurements taken by an ultrasonic bladder volume monitor. The Kalman filter was based on a double integrator as a model for the bladder filling process between micturitions and included a procedure...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345809

    authors: Kristiansen NK,Sjöström SO,Nygaard H

    更新日期:2005-05-01 00:00:00

  • Fluorescence microscopy image classification of 2D HeLa cells based on the CapsNet neural network.

    abstract::The development of computer technology now allows the quick and efficient automatic fluorescence microscopy generation of a large number of images of proteins in specific subcellular compartments using fluorescence microscopy. Digital image processing and pattern recognition technology can easily classify these images...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-01946-z

    authors: Zhang X,Zhao SG

    更新日期:2019-06-01 00:00:00

  • Automatic interpretation of hyperventilation-induced electroencephalogram constructed in the way of qualified electroencephalographer's visual inspection.

    abstract::Quantitative analysis and detection of electroencephalogram (EEG) recordings during evoked activities is essential for clinical diagnosis on neurological disorders. However, the process of interpreting EEG is time consuming for electroencephalographers (EEGers). In this study, an automatic EEG interpretation system co...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0688-9

    authors: Zhang X,Wang X,Sugi T,Ikeda A,Nagamine T,Shibasaki H,Nakamura M

    更新日期:2011-02-01 00:00:00

  • ML and MAP estimation of parameters for the Kalman filter and smoother applied to electrocardiographic imaging.

    abstract::In electrocardiographic imaging (ECGI), one solves the inverse problem of electrocardiography (ECG) to reconstruct equivalent cardiac sources based on the body surface potential measurements and a mathematical model of the torso. Due to attenuation and spatial smoothing within the torso, this inverse problem is ill-po...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02018-6

    authors: Erenler T,Serinagaoglu Dogrusoz Y

    更新日期:2019-10-01 00:00:00

  • Silicone rubber encapsulation for an endoscopically implantable gastrostimulator.

    abstract::Gastrointestinal stimulator implants have recently shown positive results in treating obesity. However, the implantation currently requires an invasive surgical procedure. Endoscopy could be used to place the gastric stimulator in the stomach, hence avoiding the riskier surgery. The implant then needs to go through th...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1236-9

    authors: Lonys L,Vanhoestenberghe A,Julémont N,Godet S,Delplancke MP,Mathys P,Nonclercq A

    更新日期:2015-04-01 00:00:00

  • Dynamic thermographic imaging method for quantifying dermal perfusion: potential and limitations.

    abstract::A new method of quantifying dermal perfusion on a regional basis using a dynamic thermographic technique is investigated. The technique is based on the relationship between dermal perfusion and the rate of skin surface reheating following the application of a transient cold challenge predicted by a theoretical model. ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441468

    authors: Wilson SB,Spence VA

    更新日期:1989-09-01 00:00:00

  • A new software scheme for scatter correction based on a simple radiographic scattering model.

    abstract::In common radiography, image contrast is often limited due mainly to scattered x-rays and noise, decreasing the quantitative usefulness of x-ray images. Several scatter reduction methods based on software correction schemes have been extensively investigated in an attempt to overcome these difficulties, most of which ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1893-1

    authors: Kim K,Kang S,Kim W,Park C,Lee D,Cho H,Kang W,Park S,Kim G,Lim H,Lee H,Park J,Jeon D,Lim Y,Woo T,Oh J

    更新日期:2019-02-01 00:00:00

  • Myocardial perfusion monitoring during coronary artery bypass using an electrocardiogram-triggered laser Doppler technique.

    abstract::Electrocardiogram (ECG)-triggered laser Doppler perfusion monitoring (LDPM) was used to assess myocardial perfusion, with minimum myocardial tissue motion influence, during coronary artery bypass grafting (CABG). Thirteen subjects were investigated at six phases: pre- and post-CABG; post aorta cross-clamping; pre and ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02351031

    authors: Karlsson MG,Fors C,Wårdell K,Casimir-Ahn H

    更新日期:2005-09-01 00:00:00

  • Varying ultrasound power level to distinguish surgical instruments and tissue.

    abstract::We investigate a new framework of surgical instrument detection based on power-varying ultrasound images with simple and efficient pixel-wise intensity processing. Without using complicated feature extraction methods, we identified the instrument with an estimated optimal power level and by comparing pixel values of v...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1695-x

    authors: Ren H,Anuraj B,Dupont PE

    更新日期:2018-03-01 00:00:00

  • Biomechanical analysis of the muscular power of martial arts athletes.

    abstract::This study analyzes the performance of knee extension and flexion of Taekwondo and Kickboxing athletes. The power values were extracted through electromyography obtained by an isokinetic dynamometer at 60 degrees per second. These values are resulted from the square of the electromyography signal. The analysis of kick...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0608-z

    authors: Machado SM,Osório RA,Silva NS,Magini M

    更新日期:2010-06-01 00:00:00

  • Model of glucose sensor error components: identification and assessment for new Dexcom G4 generation devices.

    abstract::It is clinically well-established that minimally invasive subcutaneous continuous glucose monitoring (CGM) sensors can significantly improve diabetes treatment. However, CGM readings are still not as reliable as those provided by standard fingerprick blood glucose (BG) meters. In addition to unavoidable random measure...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1226-y

    authors: Facchinetti A,Del Favero S,Sparacino G,Cobelli C

    更新日期:2015-12-01 00:00:00

  • New method using multi-regression analysis on evoked electromyography during movement to adjust stimulation conditions.

    abstract::A new method of stimulation of the lower extremities was devised that automatically adjusts the stimulation conditions at any angle of the knee joint. An M-wave is considered to indicate the stimulation conditions, because it is the waveform that results from direct stimulation to the axon of the alpha motor neuron. T...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02351018

    authors: Tanabe S,Muraoka Y,Tomita Y

    更新日期:2004-01-01 00:00:00

  • Relation between branching patterns and perfusion in stochastic generated coronary arterial trees.

    abstract::Biological variation in branching patterns is likely to affect perfusion of tissue. To assess the fundamental consequences of branching characteristics, 50 stochastic asymmetrical coronary trees and one non-stochastic symmetrical branching tree were generated. In the stochastic trees, area growth, A, at branching poin...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0139-9

    authors: Dankelman J,Cornelissen AJ,Lagro J,Vanbavel E,Spaan JA

    更新日期:2007-01-01 00:00:00

  • Extraction of Cole parameters from the electrical bioimpedance spectrum using stochastic optimization algorithms.

    abstract::Fitting the measured bioimpedance spectroscopy (BIS) data to the Cole model and then extracting the Cole parameters is a common practice in BIS applications. The extracted Cole parameters then can be analysed as descriptors of tissue electrical properties. To have a better evaluation of physiological or pathological p...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1355-y

    authors: Gholami-Boroujeny S,Bolic M

    更新日期:2016-04-01 00:00:00

  • Investigating body motion patterns in patients with Parkinson's disease using matching pursuit algorithm.

    abstract::Several recent studies have quantified abnormalities in Parkinsonian gait. However, few studies have attempted to quantify the regularity of body motion during walking in patients with Parkinson's disease. The aim of the paper was to characterise body motion patterns in healthy, elderly subjects and patients with Park...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02351008

    authors: Sekine M,Akay M,Tamura T,Higashi Y,Fujimoto T

    更新日期:2004-01-01 00:00:00

  • Measurement of sealing resistance of cell-electrode interfaces in neuronal cultures using impedance spectroscopy.

    abstract::Sealing resistance is highly significant with respect to the electrical neuron-electrode contact because it decreases the stimulation threshold of neurons cultured on a planar micro-electrode array. A method is proposed for measurement of the sealing resistance using impedance spectroscopy. The effect of the sealing r...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02524436

    authors: Buitenweg JR,Rutten WL,Willems WP,van Nieuwkasteele JW

    更新日期:1998-09-01 00:00:00

  • Interaction between steady flow and individualised compliant segments: application to upper airways.

    abstract::To describe upper airway obstruction in patients with sleep apnea syndrome, the steady state solutions of a simple model of local pharyngeal obstruction were studied. Importantly, the present model embodies a series of two individualised elements, each having its own compliance, which enables the consideration, from a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510972

    authors: Fodil R,Ribreau C,Louis B,Lofaso F,Isabey D

    更新日期:1997-11-01 00:00:00

  • Biphasic model of the trabecular meshwork in the eye.

    abstract::A biphasic continuum model for the flow of intraocular fluid, the aqueous humour, in the trabecular meshwork is proposed in the paper. The model considers the meshwork as a circular ring with uniform thickness of homogeneous, isotropic, viscoelastic material swollen with continuously percolating aqueous humour. The mo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446710

    authors: Tandon PN,Autar R

    更新日期:1991-05-01 00:00:00

  • Parallel conductance determination in cardiac volumetry using dilution manoeuvres: theoretical analysis and practical implications.

    abstract::Left ventricular volume calibration based on the conductance catheter depends on the correct determination of the parallel conductance (Gp). Baan's saline manoeuvre procedure leads to Gp by finding the end-systolic (Ges) and end-diastolic (Ged) conductances, for each beat of the dilution curve rising limb. After plott...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513284

    authors: Herrera MC,Olivera JM,Valentinuzzi ME

    更新日期:1999-03-01 00:00:00

  • Internal work estimation in three-dimensional gait analysis.

    abstract::Many studies concerning the internal work of human motion have used two-dimensional kinematic models to estimate kinetic energy of the segments. The generalised co-ordinate concept has been applied here to a simultaneous and bilateral gait analysis. A three-dimensional kinematic model based on quaternions has been dev...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02523852

    authors: Aissaoui R,Allard P,Junqua A,Frossard L,Duhaime M

    更新日期:1996-11-01 00:00:00

  • Identification of the breast boundary in mammograms using active contour models.

    abstract::A method for the identification of the breast boundary in mammograms is presented. The method can be used in the preprocessing stage of a system for computer-aided diagnosis (CAD) of breast cancer and also in the reduction of image file size in picture archiving and communication system applications. The method starte...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344632

    authors: Ferrari RJ,Rangayyan RM,Desautels JE,Borges RA,Frère AF

    更新日期:2004-03-01 00:00:00

  • Analysis of biomechanical changes after removal of instrumentation in lumbar arthrodesis by finite element analysis.

    abstract::The purpose of this study is to investigate the change in biomechanical milieu following removal of pedicle screws in instrumented single level lumbar arthrodesis. Using a validated finite element (FE) model of the intact lumbar spine (L2-5), two scenarios of L3-4 lumbar fusion were simulated: posterolateral fusion (P...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0621-2

    authors: Kim HJ,Chun HJ,Moon SH,Kang KT,Kim HS,Park JO,Moon ES,Sohn JS,Lee HM

    更新日期:2010-07-01 00:00:00

  • Estimation of the dynamics of event-related desynchronisation changes in electroencephalograms.

    abstract::A method for the estimation of medium rate transitions of non-stationary electroencephalograms (EEG) is proposed. The method is applicable to such EEG dynamics that are between (a) fast transitions for which segmentation procedures are used and (b) slow transitions for which adaptive filters work properly. The estimat...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513305

    authors: Hiltunen JK,Karjalainen PA,Partanen J,Kaipio JP

    更新日期:1999-05-01 00:00:00

  • A novel recursive Fourier transform for nonuniform sampled signals: application to heart rate variability spectrum estimation.

    abstract::We present a novel method to iteratively calculate discrete Fourier transforms for discrete time signals with sample time intervals that may be widely nonuniform. The proposed recursive Fourier transform (RFT) does not require interpolation of the samples to uniform time intervals, and each iterative transform update ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0461-0

    authors: Holland A,Aboy M

    更新日期:2009-07-01 00:00:00

  • Modelling the effect of insulin on the disposal of meal-attributable glucose in type 1 diabetes.

    abstract::The management of postprandial glucose excursions in type 1 diabetes has a major impact on overall glycaemic control. In this work, we propose and evaluate various mechanistic models to characterize the disposal of meal-attributable glucose. Sixteen young volunteers with type 1 diabetes were subject to a variable-targ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1509-6

    authors: García-García F,Hovorka R,Wilinska ME,Elleri D,Hernando ME

    更新日期:2017-02-01 00:00:00

  • A new combination: scale-space filtering of projected brain activities.

    abstract::In the present study, well known scale-space filtering (SSF) algorithm is used in combination with a linear mapping approach (LMA) to obtain clear auditory evoked potential (EP) waveform. The proposed combination involves two sequential steps: At first, the EEG noise level is reduced from -5 to 0 dB owing to the LMA b...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0450-3

    authors: Aydin S

    更新日期:2009-04-01 00:00:00