Urinary bladder volume tracking using a Kalman filter.

Abstract:

:This study introduced the Kalman filter procedure for tracking urinary bladder filling from intermittent bladder volume measurements taken by an ultrasonic bladder volume monitor. The Kalman filter was based on a double integrator as a model for the bladder filling process between micturitions and included a procedure to reset the filter in the event of a micturition. The performance of the Kalman filter was evaluated experimentally using an ultrasonic bladder volume monitor on seven male urologic patients. During cystometry, saline was infused into the patient's bladder at a constant rate of 30 ml min(-1) until it was full, and the volume of the bladder was recorded every 30 s by the bladder volume monitor. The evaluation showed that the filter significantly improved the precision of the measured volumes in terms of mean absolute errorby 4.2 ml (95% confidence interval: 0.7-7.7 ml) (p = 0.025) without affecting the system accuracy, i.e. slope (p= 0.92) and intercept (p= 0.32). Finally, the micturition reset procedure was verified using simulated data.

journal_name

Med Biol Eng Comput

authors

Kristiansen NK,Sjöström SO,Nygaard H

doi

10.1007/BF02345809

keywords:

subject

Has Abstract

pub_date

2005-05-01 00:00:00

pages

331-4

issue

3

eissn

0140-0118

issn

1741-0444

journal_volume

43

pub_type

杂志文章
  • Improvement of wireless power transmission efficiency of implantable subcutaneous devices by closed magnetic circuit mechanism.

    abstract::Induction coils were fabricated based on flexible printed circuit board for inductive transcutaneous power transmission. The coil had closed magnetic circuit (CMC) structure consisting of inner and outer magnetic core. The power transmission efficiency of the fabricated device was measured in the air and in vivo condi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0939-z

    authors: Jo SE,Joung S,Suh JK,Kim YJ

    更新日期:2012-09-01 00:00:00

  • Computerised volumetric analysis of lesions in multiple sclerosis using new semi-automatic segmentation software.

    abstract::The paper describes the application of new semi-automatic segmentation software to the task of detection of anatomical structures and lesion and their three-dimensional (3D) visualisation in 23 patients with secondary progressive multiple sclerosis (MS). The purpose is to study the correlation between magnetic resonan...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513274

    authors: Dastidar P,Heinonen T,Vahvelainen T,Elovaara I,Eskola H

    更新日期:1999-01-01 00:00:00

  • PC/VAX or standalone PC-based general purpose biological data collection system.

    abstract::A system, to collect, analyse and display biological data, is developed using IBM PC AT compatibles (PCs) or CED1401/1609 devices networked to a VAX environment. It can be operated in three separate modes: using the CED/IEEE/VAX network; using the PC/Ethernet/VAX network; as a standalone PC. The original system compri...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446881

    authors: Marlow SP,Mackenzie DA,Tomlinson JB

    更新日期:1993-01-01 00:00:00

  • Dynamic simulation of the natural and replaced human ankle joint.

    abstract::Disappointing results for total ankle replacement have been explained by poor knowledge of the mechanics of the intact and replaced joints. Dynamic simulation tools have the capacity to simulate dynamic conditions that occur in human joints. The Working Model 2D tool was used to simulate the mechanics of the intact an...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348124

    authors: Leardini A,Moschella D

    更新日期:2002-03-01 00:00:00

  • Spectral moments of mechanomyographic signals recorded with accelerometer and microphone during sustained fatiguing contractions.

    abstract::The aim of this study was to analyse the trends of the first three power spectral moments of the mechanomyogram (MMG) signal recorded by a microphone (MMG(MIC)) and an accelerometer (MMG(ACC)) during sustained contractions. MMG signals were recorded from the biceps brachii muscle in 14 healthy male subjects during a 3...

    journal_title:Medical & biological engineering & computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/s11517-006-0036-2

    authors: Madeleine P,Ge HY,Jaskólska A,Farina D,Jaskólski A,Arendt-Nielsen L

    更新日期:2006-04-01 00:00:00

  • Velocity distribution model for normal blood flow in the human ascending aorta.

    abstract::During the study of velocities in the human ascending aorta it became necessary to establish a method for two-dimensional velocity profiles from discrete velocity data obtained from different heartbeats and with different techniques. A descriptive geometrical model was therefore developed and expanded to 16 elements e...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02442319

    authors: Segadal L

    更新日期:1991-09-01 00:00:00

  • Estimating normal and pathological dynamic responses in cerebral blood flow velocity to step changes in end-tidal pCO2.

    abstract::The regulation of cerebral blood flow (CBF) following changes in arterial blood pressure (ABP) and end-tidal pCO2 (EtCO2) are of clinical interest in assessing cerebrovascular reserve capacity. Linear finite-impulse-response modelling is applied to ABP, EtCO2 and CBF velocity (CBFV, from transcranial Doppler measureme...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345749

    authors: Simpson DM,Panerai RB,Evans DH,Garnham J,Naylor AR,Bell PR

    更新日期:2000-09-01 00:00:00

  • Behaviour of two typical stents towards a new stent evolution.

    abstract::This study explores the analysis of a new stent geometry from two typical stents used to treat the coronary artery disease. Two different finite element methods are applied with different boundary conditions to investigate the stenosis region. Computational fluid dynamics (CFD) models including fluid-structure interac...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1574-x

    authors: Simão M,Ferreira JM,Mora-Rodriguez J,Fragata J,Ramos HM

    更新日期:2017-06-01 00:00:00

  • Pressures generated by rib cage and abdominal compressions during cardiopulmonary resuscitation.

    abstract::When the rib cage and abdomen are compressed during cardiopulmonary resuscitation (CPR), the effect on intrathoracic pressure, and therefore on haemodynamics, cannot be quantitatively predicted without a physiologically based mathematical model of chest wall dynamics. Using such a model, we compared model simulations ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441676

    authors: Ben-Haim SA,Shofti R,Dinnar U,Saidel GM

    更新日期:1990-01-01 00:00:00

  • Analysis of macro- and microstructures of normal and pathological tissues by ultrasonic backscattering techniques.

    abstract::A technique to obtain the spacing distribution of macro- and microstructures of hypercholestrolemic liver, lymphoidlucosed liver, rhinosporidium of man and ethmoidal tumour of bovine is presented. The method uses signal processing of spatially averaged spectra of ultrasonic backscattering from tissues in the frequency...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02442608

    authors: Swarnamani S,Singh M

    更新日期:1990-11-01 00:00:00

  • Evaluation of laser Doppler imaging to measure blood flow in knee ligaments of adult rabbits.

    abstract::Laser Doppler imaging (LDI) is investigated as a novel method for in vivo ligament tissue blood flow determination. LDI output signal is obtained from surgically exposed rabbit medial collateral ligaments (MCL). The LDI signal is compared with simultaneously determined, coloured microsphere (CM)-derived standardised M...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02520078

    authors: Bray R,Forrester K,McDougall JJ,Damji A,Ferrell WR

    更新日期:1996-05-01 00:00:00

  • Comparison between human awake, meditation and drowsiness EEG activities based on directed transfer function and MVDR coherence methods.

    abstract::This study examined the electroencephalogram functional connectivity (coherence) and effective connectivity (flow of information) of selected brain regions during three different attentive states: awake, meditation and drowsiness. For the estimation of functional connectivity (coherence), Welch and minimum variance di...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1272-0

    authors: Dissanayaka C,Ben-Simon E,Gruberger M,Maron-Katz A,Sharon H,Hendler T,Cvetkovic D

    更新日期:2015-07-01 00:00:00

  • A catheter tactile sensor for measuring hardness of soft tissue: measurement in a silicone model and in an in vitro human prostate model.

    abstract::Tissue hardness is related to tissue composition, and this is often changed by disease. It is therefore of interest to measure the hardness in an objective and non-invasive way. A tactile sensor based on a vibrating piezoelectric ceramic element in a feedback loop is described. When the sensor touches an object it pro...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513357

    authors: Eklund A,Bergh A,Lindahl OA

    更新日期:1999-09-01 00:00:00

  • Clinical applications of musculoskeletal modelling for the shoulder and upper limb.

    abstract::Musculoskeletal models have been developed to estimate internal loading on the human skeleton, which cannot directly be measured in vivo, from external measurements like kinematics and external forces. Such models of the shoulder and upper extremity have been used for a variety of purposes, ranging from understanding ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-013-1099-5

    authors: Bolsterlee B,Veeger DH,Chadwick EK

    更新日期:2013-09-01 00:00:00

  • Identification of the breast boundary in mammograms using active contour models.

    abstract::A method for the identification of the breast boundary in mammograms is presented. The method can be used in the preprocessing stage of a system for computer-aided diagnosis (CAD) of breast cancer and also in the reduction of image file size in picture archiving and communication system applications. The method starte...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344632

    authors: Ferrari RJ,Rangayyan RM,Desautels JE,Borges RA,Frère AF

    更新日期:2004-03-01 00:00:00

  • An adaptive enhancement method for breast X-ray images based on the nonsubsampled contourlet transform domain and whale optimization algorithm.

    abstract::We propose a new method for breast X-ray image adaptive enhancement that combines nonsubsampled contourlet transform (NSCT) with the whale optimization algorithm (WOA). First, the mammography X-ray image was processed by histogram equalization to ensure global image contrast. The processed image was then decomposed in...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02022-w

    authors: Zhang CJ,Nie HH

    更新日期:2019-10-01 00:00:00

  • Comparison of body fat-free masses calculated from hand-to-foot and foot-to-foot resistances with DXA measurements.

    abstract::This article compares the determination of body fat-free-mass (FFM) by impedance, using either hand-to-foot resistance (R₁₃) or foot-to-foot one (R₃₄) from comparison with dual X-ray absorptiometry (DXA) measurements in a normal population. The first goal was to see if the foot-to-foot resistance used in body fat anal...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0827-y

    authors: Bousbiat S,Jaffrin MY,Dongmo E

    更新日期:2011-11-01 00:00:00

  • Fluid flow and particle transport in mechanically ventilated airways. Part II: particle transport.

    abstract::The flow mechanisms that play a role on aerosol deposition were identified and presented in a companion paper (Timothy et al. in Med Biol Eng Comput. doi: 10.1007/s11517-015-1407-3 , 2015). In the current paper, the effects of invasive conventional mechanical ventilation waveforms and endotracheal tube (ETT) on the ae...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1408-2

    authors: Alzahrany M,Van Rhein T,Banerjee A,Salzman G

    更新日期:2016-07-01 00:00:00

  • Modeling the effect of tilting, passive leg exercise, and functional electrical stimulation on the human cardiovascular system.

    abstract::Long periods of bed rest negatively affect the human body organs, notably the cardiovascular system. To avert these negative effects and promote functional recovery in patients dealing with prolonged bed rest, the goal is to mobilize them as early as possible while controlling and stabilizing their cardiovascular syst...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1628-8

    authors: Sarabadani Tafreshi A,Okle J,Klamroth-Marganska V,Riener R

    更新日期:2017-09-01 00:00:00

  • Fluorescence microscopy image classification of 2D HeLa cells based on the CapsNet neural network.

    abstract::The development of computer technology now allows the quick and efficient automatic fluorescence microscopy generation of a large number of images of proteins in specific subcellular compartments using fluorescence microscopy. Digital image processing and pattern recognition technology can easily classify these images...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-01946-z

    authors: Zhang X,Zhao SG

    更新日期:2019-06-01 00:00:00

  • Comparison of heart rate variability spectra using generic relationships of their input signals.

    abstract::Spectral analysis of heart rate variability (HRV) is an accepted method for assessment of cardiac autonomic function and its relationship to numerous disorders and diseases. Various non-parametric methods for HRV estimation have been developed. The spectrum of counts, the instantaneous heart rate spectrum and the inte...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02524426

    authors: Mitov IP,Daskalov IK

    更新日期:1998-09-01 00:00:00

  • Noninvasive measurement of blood glucose concentrations by analysing Fourier transform infra-red absorbance spectra through oral mucosa.

    abstract::Whether Fourier transform infra-red spectroscopy with an attenuated total reflection prism could be applied for noninvasive glucose measurement through oral mucosa was evaluated. As a result, the same absorbance peak at 1033 cm-1 as in glucose aqueous solution was found in the absorbance spectra through mucous membran...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446645

    authors: Kajiwara K,Uemura T,Kishikawa H,Nishida K,Hashiguchi Y,Uehara M,Sakakida M,Ichinose K,Shichiri M

    更新日期:1993-07-01 00:00:00

  • Mechanical and electromotile characteristics of auditory outer hair cells.

    abstract::The passive and active properties of the cochlear outer hair cell are studied. The outer hair cell is currently considered the major candidate for the active component of mammalian hearing. Understanding of its properties may explain the amplification and sharp frequency selectivity of the ear. To analyse the cell beh...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513294

    authors: Spector AA,Brownell WE,Popel AS

    更新日期:1999-03-01 00:00:00

  • Modelling the dynamics of expiratory airflow to describe chronic obstructive pulmonary disease.

    abstract::Chronic obstructive pulmonary disease (COPD) is characterized by expiratory airflow limitation, but current diagnostic criteria only consider flow till the first second and are therefore strongly debated. We aimed to develop a data-based individualized model for flow decline and to explore the relationship between mod...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1202-6

    authors: Topalovic M,Exadaktylos V,Decramer M,Troosters T,Berckmans D,Janssens W

    更新日期:2014-12-01 00:00:00

  • Fluctuation analysis of respiratory impedance waveform in asthmatic patients: effect of airway obstruction.

    abstract::Fluctuation analysis has great potential to contribute to pulmonary clinical science and practice. We evaluated the relationship between asthma and the respiratory impedance recurrence period density entropy (RPDEnZrs) and the variability (SDZrs). A non-invasive and simple protocol for assessing respiratory mechanics ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0957-x

    authors: Veiga J,Lopes AJ,Jansen JM,Melo PL

    更新日期:2012-12-01 00:00:00

  • Fully coupled fluid-structure interaction model of congenital bicuspid aortic valves: effect of asymmetry on hemodynamics.

    abstract::A bicuspid aortic valve (BAV) is a congenital cardiac disorder where the valve consists of only two cusps instead of three, as in a normal tricuspid valve (TAV). Although 97 % of BAVs include asymmetric cusps, little or no prior studies have investigated the blood flow through a three-dimensional BAV and root. The aim...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1055-4

    authors: Marom G,Kim HS,Rosenfeld M,Raanani E,Haj-Ali R

    更新日期:2013-08-01 00:00:00

  • Spatio-spectral filters for low-density surface electromyographic signal classification.

    abstract::In this paper, we proposed to utilize a novel spatio-spectral filter, common spatio-spectral pattern (CSSP), to improve the classification accuracy in identifying intended motions based on low-density surface electromyography (EMG). Five able-bodied subjects and a transradial amputee participated in an experiment of e...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-1024-3

    authors: Huang G,Zhang Z,Zhang D,Zhu X

    更新日期:2013-05-01 00:00:00

  • Radial strain assessment of the interventricular septum wall by a new technique in healthy subjects.

    abstract::The aim of this study was to design a new approach for the acquisition of regional radial strain from the middle portion of the interventricular septum. We designed and wrote a program in Matlab (computer-assisted method) for use on a personal computer so that the septum thickness throughout the cardiac cycle could be...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0222-x

    authors: Moladoust H,Mokhtari-Dizaji M,Ojaghi-Haghighi Z,D'hooge J,Noohi F,Khaledifar A,Khajavi A

    更新日期:2007-09-01 00:00:00

  • Methods of dynamic spectral analysis by self-exciting autoregressive moving average models and their application to analysing biosignals.

    abstract::Dynamic methods in the spectral domain are necessary to analyse biological signals because of the frequently nonstationary character of the signals. The paper presents an adaptive procedure of fitting time-dependent ARMA models to nonstationary signals, which is suitable for on-line calculations. The properties of the...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510536

    authors: Schack B,Bareshova E,Grieszbach G,Witte H

    更新日期:1995-05-01 00:00:00

  • Effect of signal length on the performance of independent component analysis when extracting the lambda wave.

    abstract::The aim of the study was to investigate the effect of signal length on the performance of a signal source separation method, independent component analysis (ICA), when extracting the visual evoked potential (EP) lambda wave from saccade-related electro-encephalogram (EEG) waveforms. A method was devised that enabled t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348134

    authors: Vigon L,Saatchi R,Mayhew JE,Taroyan NA,Frisby JP

    更新日期:2002-03-01 00:00:00