A catheter tactile sensor for measuring hardness of soft tissue: measurement in a silicone model and in an in vitro human prostate model.

Abstract:

:Tissue hardness is related to tissue composition, and this is often changed by disease. It is therefore of interest to measure the hardness in an objective and non-invasive way. A tactile sensor based on a vibrating piezoelectric ceramic element in a feedback loop is described. When the sensor touches an object it produces a frequency shift related to the hardness of the object. The aim of this study was to develop an in vitro hardness measurement method using a catheter type version of the sensor. The method was evaluated in an established silicone tissue model and on human prostate tissue in vitro. A linear relationship was found with a high degree of explanation (R2 = 0.98) between a cone penetration hardness standard (DIN ISO 2137) applied to the silicone model and the corresponding frequency shift. The results from measurements on a human prostate tissue sample, fixed with formalin, showed that the relative hardness measured with the tactile sensor correlated (R = -0.96, p < 0.001, N = 60) with the proposed hardness related to the histological composition of the prostate tissue. The results indicated that hardness of prostate tissue, and maybe hardness of human tissue in general, can be expressed according to the cone penetration standard and that the hardness can be measured with this tactile sensory system. These findings hold the promise of further development of a non-invasive tool for hardness measurement in a clinical situation.

journal_name

Med Biol Eng Comput

authors

Eklund A,Bergh A,Lindahl OA

doi

10.1007/BF02513357

keywords:

subject

Has Abstract

pub_date

1999-09-01 00:00:00

pages

618-24

issue

5

eissn

0140-0118

issn

1741-0444

journal_volume

37

pub_type

杂志文章
  • Improvement of spike train decoder under spike detection and classification errors using support vector machine.

    abstract::The successful decoding of kinematic variables from spike trains of motor cortical neurons is essential for cortical neural prosthesis. Spike trains from each single unit must be extracted from extracellular neural signals and, thus, spike detection and sorting procedure is indispensable but the detection and sorting ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-005-0009-x

    authors: Kim KH,Kim SS,Kim SJ

    更新日期:2006-03-01 00:00:00

  • The formation of extracellular potentials over the innervation zone: Are these potentials affected by changes in fibre membrane properties?

    abstract::Widespread misconceptions still exist regarding the formation of extracellular potentials over the innervation zone: the assumption (1) that the first phase of these potentials mainly reflects the process of initiation of the intracellular action potential (IAP) at the neuromuscular junction and that (2) these potenti...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1487-8

    authors: Rodriguez-Falces J

    更新日期:2016-12-01 00:00:00

  • Left-ventricular pressure gradients: a computer-model simulation.

    abstract::Both invasive left-ventricular pressure measurements and non-invasive colour M-mode echographic measurements have shown the existence of intraventricular pressure gradients (IVPGs) during early filling. The mechanisms responsible for these IVPG cannot be completely explained by the experiments. Therefore a one-dimensi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513338

    authors: Verdonck P,Vierendeels J,Riemslagh K,Dick E

    更新日期:1999-07-01 00:00:00

  • Hybrid stent device of flow-diverting effect and stent-assisted coil embolization formed by fractal structure.

    abstract::This paper presents a novel hybrid medical stent device. This hybrid stent device formed by fractal mesh structures provides a flow-diverting effect and stent-assisted coil embolization. Flow-diverter stents decrease blood flow into an aneurysm to prevent its rupture. In general, the mesh size of a flow-diverter stent...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1374-8

    authors: Kojima M,Irie K,Masunaga K,Sakai Y,Nakajima M,Takeuchi M,Fukuda T,Arai F,Negoro M

    更新日期:2016-05-01 00:00:00

  • Direct nanodrug delivery for tumor targeting subject to shear-augmented diffusion in blood flow.

    abstract::The advent of multifunctional nanoparticle has enabled numerous innovative strategies in diagnostics, imaging, and cancer therapy. Despite the intense research efforts in developing new nanoparticles and surface bonding ligands, one major obstacle in achieving highly effective treatment, including minimizing detriment...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1818-z

    authors: Xu Z,Kleinstreuer C

    更新日期:2018-11-01 00:00:00

  • On-line monitoring of solutes in dialysate using wavelength-dependent absorption of ultraviolet radiation.

    abstract::The aim of the study was to assess the wavelength dependence of the UV absorbance during monitoring of different compounds in the dialysate. UV absorbance was determined by using a double-beam spectrophotometer on dialysate samples taken at pre-determined times during dialysis, over a wavelength range of 180-380 nm. C...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348430

    authors: Fridolin I,Lindberg LG

    更新日期:2003-05-01 00:00:00

  • A novel finite element model-based navigation system-supported workflow for breast tumor excision.

    abstract::In the case of female breast cancer, a breast-conserving excision is often desirable. This surgery is based on preoperatively gathered MRI, mammography, and sonography images. These images are recorded in multiple patient positions, e. g., 2D mammography images in standing position with a compressed breast and 3D MRI ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01977-0

    authors: Esslinger D,Rapp P,Knödler L,Preibsch H,Tarín C,Sawodny O,Brucker SY,Hahn M

    更新日期:2019-07-01 00:00:00

  • Real-time human motion estimation using biomechanical models and non-linear state-space filters.

    abstract::In the field of sports biomechanics and rehabilitation engineering, the possibility of computing, in real time, the angular displacements and derivatives of human joints, from a video of motion sequences, represents an appealing goal. In particular, applications of biofeedback protocols in rehabilitation can benefit f...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344878

    authors: Cerveri P,Rabuffetti M,Pedotti A,Ferrigno G

    更新日期:2003-03-01 00:00:00

  • Improvement of wireless power transmission efficiency of implantable subcutaneous devices by closed magnetic circuit mechanism.

    abstract::Induction coils were fabricated based on flexible printed circuit board for inductive transcutaneous power transmission. The coil had closed magnetic circuit (CMC) structure consisting of inner and outer magnetic core. The power transmission efficiency of the fabricated device was measured in the air and in vivo condi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0939-z

    authors: Jo SE,Joung S,Suh JK,Kim YJ

    更新日期:2012-09-01 00:00:00

  • Inducing therapeutic hypothermia via selective brain cooling: a finite element modeling analysis.

    abstract::Therapeutic hypothermia is a treatment method to reduce brain injuries after stroke, especially for cerebral ischemia. This study investigates in the temperature distribution of the head within selective brain cooling (SBC). Anatomically accurate geometries based on CT images of head and neck regions are used to devel...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01962-7

    authors: Yin L,Jiang H,Zhao W,Li H

    更新日期:2019-06-01 00:00:00

  • Theoretical study of the effect of local flow disturbances on the concentration of low-density lipoproteins at the luminal surface of end-to-end anastomosed vessels.

    abstract::To elucidate the mechanisms of localisation of intimal hyperplasia in anastomosed arteries, the effects of flow disturbances on the transport of low-density lipoproteins (LDLs) from the flowing blood to the wall of end-to-end anastomosed arteries, with and without a moderate stenosis, were studied theoretically by mea...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345458

    authors: Wada S,Koujiya M,Karino T

    更新日期:2002-09-01 00:00:00

  • Radial strain assessment of the interventricular septum wall by a new technique in healthy subjects.

    abstract::The aim of this study was to design a new approach for the acquisition of regional radial strain from the middle portion of the interventricular septum. We designed and wrote a program in Matlab (computer-assisted method) for use on a personal computer so that the septum thickness throughout the cardiac cycle could be...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0222-x

    authors: Moladoust H,Mokhtari-Dizaji M,Ojaghi-Haghighi Z,D'hooge J,Noohi F,Khaledifar A,Khajavi A

    更新日期:2007-09-01 00:00:00

  • Dependence of excitability indices on membrane channel dynamics, myelin impedance, electrode location and stimulus waveforms in myelinated and unmyelinated fibre models.

    abstract::Neuronal excitability is determined in a complex way by several interacting factors, such as membrane dynamics, fibre geometry, electrode configuration, myelin impedance, neuronal terminations[Formula: see text] This study aims to increase understanding in excitability, by investigating the impact of these factors on ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1799-y

    authors: Tarnaud T,Joseph W,Martens L,Tanghe E

    更新日期:2018-09-01 00:00:00

  • Improved performance of intravascular pO2 sensor incorporating poly(MPC-co-BMA) membrane.

    abstract::The first in vivo evaluation of a pO2 sensor constructed with a novel copolymer is described. The performance of the sensor is assessed under dynamic conditions in vitro and in vivo. This sensor is more stable and reliable than the control sensor with a heparin-treated polyethylene membrane. ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02511245

    authors: Zhang S,Wright G,Kingston MA,Rolfe P

    更新日期:1996-07-01 00:00:00

  • Silicon-based microelectrodes for neurophysiology, micromachined from silicon-on-insulator wafers.

    abstract::A process is described for the fabrication of silicon-based microelectrodes for neurophysiology using bonded and etched-back silicon-on-insulator (BESOI) wafers. The probe shapes are defined without high levels of boron doping in the silicon; this is considered as a step towards producing probes with active electronic...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344773

    authors: Ensell G,Banks DJ,Richards PR,Balachandran W,Ewins DJ

    更新日期:2000-03-01 00:00:00

  • Optimal chest compression in cardiopulmonary resuscitation depends upon thoracic and back support stiffness.

    abstract::A biomechanical analysis of the constant peak displacement and constant peak force methods of cardiopulmonary resuscitation (CPR) has revealed that optimal CC performance strongly depends on back support stiffness, CC rate, and the thoracic stiffness of the patient being resuscitated. Clinically the results presented ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0963-z

    authors: Dellimore KH,Scheffer C

    更新日期:2012-12-01 00:00:00

  • Performance analysis of melanoma classifier using electrical modeling technique.

    abstract::An efficient and novel modeling approach is proposed in this paper for identifying proteins or genes involved in melanoma skin cancer. Two types of classifiers are modeled, based on the chemical structure and hydropathy property of amino acids. These classifiers are further implemented using NI LabVIEW-based hardware ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02241-6

    authors: Roy T,Bhattacharjee P

    更新日期:2020-10-01 00:00:00

  • Development of a comprehensive musculoskeletal model of the shoulder and elbow.

    abstract::The Delft Shoulder and Elbow Model (DSEM), a musculoskeletal model of the shoulder and elbow has been extensively developed since its introduction in 1994. Extensions cover both model structures and anatomical data focusing on the addition of an elbow part and muscle architecture parameters. The model was also extende...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0839-7

    authors: Nikooyan AA,Veeger HE,Chadwick EK,Praagman M,Helm FC

    更新日期:2011-12-01 00:00:00

  • Adaptive processing bandwidth adjustment for laser Doppler flowmetry.

    abstract::A novel laser Doppler flowmetry scheme is reported that adjusts the processing bandwidth adaptively to optimise the estimation of flow. To obtain an adequate processing bandwidth, the Doppler spectra is first fitted to the Lorentzian function, and the bandwidth at half the maximum of the Lorentzian function is used as...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344700

    authors: Chen YY,Lin YH,Jan IC,Liu RS,Chou NK,Jan GJ

    更新日期:2004-05-01 00:00:00

  • Design and application of sensor for recording sounds over human eye and nose.

    abstract::The recording of sounds over the orbit of the eye has been found to be useful in the detection of intracranial aneurysms. A hydrophone for auscultation over the eye has been developed and is tested under controlled conditions. The tests consist of measurement over the eyes in three healthy volunteers at rest, during v...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02523031

    authors: Journée HL,van Bruggen AC,van der Meer JJ,de Jonge AB,Mooij JJ

    更新日期:1995-03-01 00:00:00

  • Quantitative video-based gait pattern analysis for hemiparkinsonian rats.

    abstract::Gait disturbances are common in the rat model of Parkinson's disease (PD) by administrating 6-hydroxydopamine. However, few studies have simultaneously assessed spatiotemporal gait indices and the kinematic information of PD rats during overground locomotion. This study utilized a simple, accurate, and reproducible me...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0933-5

    authors: Lee HY,Hsieh TH,Liang JI,Yeh ML,Chen JJ

    更新日期:2012-09-01 00:00:00

  • Modeling the pharyngeal anatomical effects on breathing resistance and aerodynamically generated sound.

    abstract::The objective of this study was to systematically assess the effects of pharyngeal anatomical details on breathing resistance and acoustic characteristics by means of computational modeling. A physiologically realistic nose-throat airway was reconstructed from medical images. Individual airway anatomy such as the uvul...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1160-z

    authors: Xi J,Si X,Kim J,Su G,Dong H

    更新日期:2014-07-01 00:00:00

  • Visualisation method of spatial interictal discharges in temporal epilepsy patients using magneto-encephalogram.

    abstract::The aim of the study was to develop a method for investigating how interictal epileptic discharges in temporal epilepsy patients are activated spatially. The activity was measured using magneto-encephalography (MEG). The MEG data were used to produce a current-arrow map that reflected the topographic distribution of t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344215

    authors: Kandori A,Oe H,Miyashita K,Date H,Yamada N,Naritomi H,Chiba Y,Murakami M,Miyashita T,Tsukada K

    更新日期:2002-05-01 00:00:00

  • "Hippocrates-mst": a prototype for computer-aided microcalcification analysis and risk assessment for breast cancer.

    abstract::One of the most common cancer types among women is breast cancer. Regular mammographic examinations increase the possibility for early diagnosis and treatment and significantly improve the chance of survival for patients with breast cancer. Clustered microcalcifications have been considered as important indicators of ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0117-2

    authors: Spyrou G,Kapsimalakou S,Frigas A,Koufopoulos K,Vassilaros S,Ligomenides P

    更新日期:2006-11-01 00:00:00

  • RETRACTED ARTICLE: Deep convolutional neural network-based speech enhancement to improve speech intelligibility and quality for hearing-impaired listeners.

    abstract:: ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,撤回出版物

    doi:10.1007/s11517-018-1933-x

    authors: Khaleelur Rahiman PF,Jayanthi VS,Jayanthi AN

    更新日期:2019-03-01 00:00:00

  • Spatial and temporal variations in the magnetic fields produced by human gastrointestinal activity.

    abstract::Magnetoenterography (MENG) is a new, non-invasive technique that measures gastrointestinal magnetic signals near the body surface. This study was undertaken to evaluate the temporal and spatial characteristics of the magnetic signals generated by gastric and duodenal slow wave activity. The gastrointestinal magnetic f...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513347

    authors: Turnbull GK,Ritcey SP,Stroink G,Brandts B,van Leeuwen P

    更新日期:1999-09-01 00:00:00

  • Development and validation of a pressure-type automated quantitative sensory testing system for point-of-care pain assessment.

    abstract::Quantitative sensory testing (QST) can provide useful information about the underlying mechanisms involved in chronic pain. However, currently available devices typically employed suffer from operator-dependent effects, or are too cumbersome for routine clinical care. This paper presents the design and initial validat...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1033-x

    authors: Harte SE,Mitra M,Ichesco EA,Halvorson ME,Clauw DJ,Shih AJ,Kruger GH

    更新日期:2013-06-01 00:00:00

  • Classification of basic daily movements using a triaxial accelerometer.

    abstract::A generic framework for the automated classification of human movements using an accelerometry monitoring system is introduced. The framework was structured around a binary decision tree in which movements were divided into classes and subclasses at different hierarchical levels. General distinctions between movements...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02347551

    authors: Mathie MJ,Celler BG,Lovell NH,Coster AC

    更新日期:2004-09-01 00:00:00

  • New method using multi-regression analysis on evoked electromyography during movement to adjust stimulation conditions.

    abstract::A new method of stimulation of the lower extremities was devised that automatically adjusts the stimulation conditions at any angle of the knee joint. An M-wave is considered to indicate the stimulation conditions, because it is the waveform that results from direct stimulation to the axon of the alpha motor neuron. T...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02351018

    authors: Tanabe S,Muraoka Y,Tomita Y

    更新日期:2004-01-01 00:00:00

  • Dialysate-side urea kinetics. Neural network predicts dialysis dose during dialysis.

    abstract::Determination of the adequacy of dialysis is a routine but crucial procedure in patient evaluation. The total dialysis dose, expressed as Kt/V, has been widely recognised to be a major determinant of morbidity and mortality in haemodialysed patients. Many different factors influence the correct determination of Kt/V, ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348080

    authors: Fernández EA,Valtuille R,Willshaw P,Perazzo CA

    更新日期:2003-07-01 00:00:00