Abstract:
:Induction coils were fabricated based on flexible printed circuit board for inductive transcutaneous power transmission. The coil had closed magnetic circuit (CMC) structure consisting of inner and outer magnetic core. The power transmission efficiency of the fabricated device was measured in the air and in vivo condition. It was confirmed that the CMC coil had higher transmission efficiency than typical air-core coil. The power transmission efficiency during a misalignment between primary coil and implanted secondary coil was also evaluated. The decrease of mutual inductance between the two coils caused by the misalignment led to a low efficiency of the inductive link. Therefore, it is important to properly align the primary coil and implanted secondary coil for effective power transmission. To align the coils, a feedback coil was proposed. This was integrated on the backside of the primary coil and enabled the detection of a misalignment of the primary and secondary coils. As a result of using the feedback coil, the primary and secondary coils could be aligned without knowledge of the position of the implanted secondary coil.
journal_name
Med Biol Eng Computjournal_title
Medical & biological engineering & computingauthors
Jo SE,Joung S,Suh JK,Kim YJdoi
10.1007/s11517-012-0939-zsubject
Has Abstractpub_date
2012-09-01 00:00:00pages
973-80issue
9eissn
0140-0118issn
1741-0444journal_volume
50pub_type
杂志文章abstract::A bicuspid aortic valve (BAV) is a congenital cardiac disorder where the valve consists of only two cusps instead of three, as in a normal tricuspid valve (TAV). Although 97 % of BAVs include asymmetric cusps, little or no prior studies have investigated the blood flow through a three-dimensional BAV and root. The aim...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-013-1055-4
更新日期:2013-08-01 00:00:00
abstract::The problem of excess cerebrospinal fluid in the brain (hydrocephalus) is generally managed using a passive pressure or flow regulated mechanical shunt. Despite the success of such devices, they have been plagued with a number of problems. It is desirable to have a shunt valve that responds dynamically to the changing...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-010-0716-9
更新日期:2011-01-01 00:00:00
abstract::This study analyzes the performance of knee extension and flexion of Taekwondo and Kickboxing athletes. The power values were extracted through electromyography obtained by an isokinetic dynamometer at 60 degrees per second. These values are resulted from the square of the electromyography signal. The analysis of kick...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-010-0608-z
更新日期:2010-06-01 00:00:00
abstract::Axial and transverse components of liquid velocity are measured by laser Doppler anemometer in a perspex tube that has been deformed at one point to resemble the shape of the throat of a partially collapsed flexible tube, conveying fluid while being compressed externally. The Reynolds number is 5900. The flow down-str...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345363
更新日期:2001-07-01 00:00:00
abstract::High-intensity noises are a health hazard for industrial workers, and hearing protection is necessary to prevent hearing loss. Passive methods, such as ear muffs, are ineffective against low-frequency noise. Moreover, many hearing-impaired workers must wear hearing aids to enable communication at their workplace, and ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02430951
更新日期:2005-11-01 00:00:00
abstract::A rapid-access but limited vocabulary communication aid for the non-vocal and speech impaired is useful in some well defined situations. The design and construction of such a device is described. Three distinct situations have been identified where an aid is essential and an initial evaluation has shown the Pocket Spe...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02441487
更新日期:1989-05-01 00:00:00
abstract::Breast cancer is the most common cancer among women globally, and the number of young women diagnosed with this disease is gradually increasing over the years. Mammography is the current gold-standard technique although it is known to be less sensitive in detecting tumors in woman with dense breast tissue. Detecting a...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1403-7
更新日期:2016-09-01 00:00:00
abstract::The regulation of cerebral blood flow (CBF) following changes in arterial blood pressure (ABP) and end-tidal pCO2 (EtCO2) are of clinical interest in assessing cerebrovascular reserve capacity. Linear finite-impulse-response modelling is applied to ABP, EtCO2 and CBF velocity (CBFV, from transcranial Doppler measureme...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345749
更新日期:2000-09-01 00:00:00
abstract::Over a period of some years, the components of a system for discerning erosion on children's teeth have been progressively developed, for use in an extensive project seeking correlations between erosion and various perceived risk factors. The aim was the detection of minute levels of erosion, based on mappings of the ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02348090
更新日期:2003-07-01 00:00:00
abstract::A process is described for the fabrication of silicon-based microelectrodes for neurophysiology using bonded and etched-back silicon-on-insulator (BESOI) wafers. The probe shapes are defined without high levels of boron doping in the silicon; this is considered as a step towards producing probes with active electronic...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344773
更新日期:2000-03-01 00:00:00
abstract::In the present study, well known scale-space filtering (SSF) algorithm is used in combination with a linear mapping approach (LMA) to obtain clear auditory evoked potential (EP) waveform. The proposed combination involves two sequential steps: At first, the EEG noise level is reduced from -5 to 0 dB owing to the LMA b...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0450-3
更新日期:2009-04-01 00:00:00
abstract::Successful identification of gastric slow waves in canine gastric electrical activity (GEA) data was achieved using a statistical data-processing procedure based on the multiple linear regression (MLR) curve fitting technique. Both distal and proximal waveforms were identified, first by construction of separate orthon...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345076
更新日期:2002-07-01 00:00:00
abstract::In vivo follow-up of muscle shape variation represents a challenge when evaluating muscle development due to disease or treatment. Recent developments in muscles reconstruction techniques indicate MRI as a clinical tool for the follow-up of the thigh muscles. The comparison of 3D muscles shape from two different seque...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1302-y
更新日期:2015-10-01 00:00:00
abstract::The mechanical impedance of the ankle joint during electrical stimulation of the soleus is studied by applying constant-velocity 10 degrees angular perturbations to the ankle and measuring the resultant torque. Both neurologically intact subjects and spinal cord injured subjects are tested. Lumped, piecewise linear mo...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02512522
更新日期:1994-05-01 00:00:00
abstract::Left ventricular volume calibration based on the conductance catheter depends on the correct determination of the parallel conductance (Gp). Baan's saline manoeuvre procedure leads to Gp by finding the end-systolic (Ges) and end-diastolic (Ged) conductances, for each beat of the dilution curve rising limb. After plott...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02513284
更新日期:1999-03-01 00:00:00
abstract::Fitting the measured bioimpedance spectroscopy (BIS) data to the Cole model and then extracting the Cole parameters is a common practice in BIS applications. The extracted Cole parameters then can be analysed as descriptors of tissue electrical properties. To have a better evaluation of physiological or pathological p...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1355-y
更新日期:2016-04-01 00:00:00
abstract::A previously proposed finite element model that considers geometric and material nonlinearities and the free boundary problems that occur at the catheter tip and in the annular zone around the lateral surface of the catheter was revised and was used to fit a power-law formula to predict backflow length during infusion...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-014-1187-1
更新日期:2014-10-01 00:00:00
abstract::The management of postprandial glucose excursions in type 1 diabetes has a major impact on overall glycaemic control. In this work, we propose and evaluate various mechanistic models to characterize the disposal of meal-attributable glucose. Sixteen young volunteers with type 1 diabetes were subject to a variable-targ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-016-1509-6
更新日期:2017-02-01 00:00:00
abstract::The main constituent of an ultrasound contrast agent (UCA) is gas-filled microbubbles. An average UCA contains billions per ml. These microbubbles are excellent ultrasound scatterers due to their high compressibility. In an ultrasound field they act as resonant systems, resulting in harmonic energy in the backscattere...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0497-1
更新日期:2009-08-01 00:00:00
abstract::With the advent of biomedical imaging technology, the number of captured and stored biomedical images is rapidly increasing day by day in hospitals, imaging laboratories and biomedical institutions. Therefore, more robust biomedical image analysis technology is needed to meet the requirement of the diagnosis and class...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-018-1819-y
更新日期:2019-01-01 00:00:00
abstract::Vertebral fractures are common in children with osteogenesis imperfecta (OI). Current imaging methods for fracture detection (X-ray and DXA) use ionising radiation. This pilot study explored whether the alteration in blood flow in vertebral fractures results in skin temperature changes that may be detected using high ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-018-1806-3
更新日期:2018-09-01 00:00:00
abstract::Respiratory rate (RR) is an important vital sign which can be difficult to measure accurately and unobtrusively in routine clinical practice. Pulse transit time (PTT), on the other hand, is unobtrusive to collect from electrocardiogram (ECG) and photoplethysmogram (PPG) signals. Using PTT is a novel method to estimate...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02088-6
更新日期:2020-02-01 00:00:00
abstract::The aim of this study was to evaluate feasibility and reproducibility of quantitative assessment of colonic morphology on CT colonography (CTC). CTC datasets from 60 patients with optimal colonic distension were assessed using prototype software. Metrics potentially associated with poor endoscopic performance were cal...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-016-1529-2
更新日期:2017-03-01 00:00:00
abstract::The recording of sounds over the orbit of the eye has been found to be useful in the detection of intracranial aneurysms. A hydrophone for auscultation over the eye has been developed and is tested under controlled conditions. The tests consist of measurement over the eyes in three healthy volunteers at rest, during v...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02523031
更新日期:1995-03-01 00:00:00
abstract::Laser Doppler imaging (LDI) is investigated as a novel method for in vivo ligament tissue blood flow determination. LDI output signal is obtained from surgically exposed rabbit medial collateral ligaments (MCL). The LDI signal is compared with simultaneously determined, coloured microsphere (CM)-derived standardised M...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02520078
更新日期:1996-05-01 00:00:00
abstract::Soleus muscle flap as coverage tissue is a possible surgical solution adopted to cover the wounds due to open fractures. Despite this procedure presents many clinical advantages, relatively poor information is available about the loss of functionality of triceps surae of the treated leg. In this study, a group of pati...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-020-02286-7
更新日期:2021-01-01 00:00:00
abstract::To describe the spatial and temporal profiles of connectivity networks and sources preceding generalized spike-and-wave discharges (SWDs) in human absence epilepsy. Nonlinear associations of MEG signals and cluster indices obtained within the framework of graph theory were determined, while source localization in the ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-011-0778-3
更新日期:2011-05-01 00:00:00
abstract::The Delft Shoulder and Elbow Model (DSEM), a musculoskeletal model of the shoulder and elbow has been extensively developed since its introduction in 1994. Extensions cover both model structures and anatomical data focusing on the addition of an elbow part and muscle architecture parameters. The model was also extende...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-011-0839-7
更新日期:2011-12-01 00:00:00
abstract::The software system GASepo has been developed as a tool to visualise and analyse doping (searching for performance-enhancing drugs in sports) with recombinant erythropoietin (rEpo). Digital images derived from the separation of Epo isoforms in gels by iso-electric focusing followed by double blotting and chemiluminesc...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345819
更新日期:2005-05-01 00:00:00
abstract::We propose a new method for breast X-ray image adaptive enhancement that combines nonsubsampled contourlet transform (NSCT) with the whale optimization algorithm (WOA). First, the mammography X-ray image was processed by histogram equalization to ensure global image contrast. The processed image was then decomposed in...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02022-w
更新日期:2019-10-01 00:00:00