Abstract:
:A novel laser Doppler flowmetry scheme is reported that adjusts the processing bandwidth adaptively to optimise the estimation of flow. To obtain an adequate processing bandwidth, the Doppler spectra is first fitted to the Lorentzian function, and the bandwidth at half the maximum of the Lorentzian function is used as an indicator of the major frequency range of the signal. The processing bandwidth is then tuned accordingly, and a frequency-weighted algorithm is applied to compute the fluid velocity. To investigate the influence of the processing bandwidth, an in vitro experiment was performed. In the experiment, the flow rate was controlled at constant velocity in the range from 0 to 18.52 mm s(-1), and the fluid velocity indices were calculated using adaptive and fixed processing bandwidths, respectively. The results showed that the adaptive processing bandwidth adjustment, not only significantly reduced the biological zero (9.6% of the case using 100 kHz bandwidth), but also enhanced the sensitivity of the laser Doppler measurement (over 20%) and linearly responded to a wider velocity range (R2 = 0.979 for velocity from 0 to 18.52 mm s(-1)).
journal_name
Med Biol Eng Computjournal_title
Medical & biological engineering & computingauthors
Chen YY,Lin YH,Jan IC,Liu RS,Chou NK,Jan GJdoi
10.1007/BF02344700keywords:
subject
Has Abstractpub_date
2004-05-01 00:00:00pages
277-81issue
3eissn
0140-0118issn
1741-0444journal_volume
42pub_type
杂志文章abstract::Instrumentation to measure accurately the stresses at the interface of a residual limb and prosthetic socket has a strong potential for use in prosthetic treatment. As a tool in the clinical setting, the device would allow a clinician to identify sites of excessive loading, information which could then be combined wit...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/BF02522507
更新日期:1995-07-01 00:00:00
abstract::Multi-scale modeling of the musculoskeletal system plays an essential role in the deep understanding of complex mechanisms underlying the biological phenomena and processes such as bone metabolic processes. Current multi-scale models suffer from the isolation of sub-models at each anatomical scale. The objective of th...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-016-1572-z
更新日期:2017-06-01 00:00:00
abstract::Biological variation in branching patterns is likely to affect perfusion of tissue. To assess the fundamental consequences of branching characteristics, 50 stochastic asymmetrical coronary trees and one non-stochastic symmetrical branching tree were generated. In the stochastic trees, area growth, A, at branching poin...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-006-0139-9
更新日期:2007-01-01 00:00:00
abstract::Neural networks are trained to estimate the germination percentages of Plasmopara viticola oospores, overwintered in natural conditions in two viticultural areas in northern Italy, by using climatic (temperature and rainfall) data, as well as the previous germination measurement, as input variables. The 288 available ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344698
更新日期:2000-01-01 00:00:00
abstract::Understanding the hemodynamics surrounding the venous valve environment is of a great importance for prosthetic valves design. The present study aims to evaluate the effect of leaflets' stiffening process on the venous valve hemodynamics, valve's failure on the next proximal valve hemodynamics and valve's failure in a...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-016-1575-9
更新日期:2017-06-01 00:00:00
abstract::Pre-operative diagnosis of chest-wall deformity is important for successful surgical correction and post-operative evaluation of funnel chest patients. However, conventional indices that define the severity of deformity have several limitations; manually calculated and cannot supply information about asymmetry. We dev...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-008-0367-2
更新日期:2008-08-01 00:00:00
abstract::Induction coils were fabricated based on flexible printed circuit board for inductive transcutaneous power transmission. The coil had closed magnetic circuit (CMC) structure consisting of inner and outer magnetic core. The power transmission efficiency of the fabricated device was measured in the air and in vivo condi...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-0939-z
更新日期:2012-09-01 00:00:00
abstract::During scoliosis instrumentation surgery, it is difficult for surgeons fully to track vertebral motion in 3D, because only the posterior elements of the spine are exposed. Different intra-operative modelling approaches are evaluated using a registration technique that matches intra-operative measurements with a 3D pre...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02513328
更新日期:1999-07-01 00:00:00
abstract::A method is presented for automatic analysis of the P-wave, based on lead II of a 12-lead standard ECG, in resting conditions during a routine examination for the detection of patients prone to atrial fibrillation (AF), one of the most prevalent arrhythmias. First, the P-wave was delineated, and this was achieved in t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02347697
更新日期:2002-01-01 00:00:00
abstract::On the basis of spatial covariance it is found that, by spatial filtering the localisation of a single dipole source, both parallel and perpendicular to the measurement plane (assuming a signal-noise ratio of 5:1), can be performed with an accuracy of < 0.5 mm. When the signal-noise ratio is increased to 30:1, the res...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02510982
更新日期:1997-11-01 00:00:00
abstract::Magnetic nanoparticles for therapy and diagnosis are at the leading edge of the rapidly developing field of bionanotechnology. In this study, we have theoretically studied motion of magnetic nano- as well as micro-particles in the field of cylindrical Halbach array of permanent magnets. Magnetic flux density was model...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-010-0636-8
更新日期:2010-08-01 00:00:00
abstract::Electromyography (EMG) in a bio-driven system is used as a control signal, for driving a hand prosthesis or other wearable assistive devices. Processing to get informative drive signals involves three main modules: preprocessing, dimensionality reduction, and classification. This paper proposes a system for classifyin...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-018-1857-5
更新日期:2018-12-01 00:00:00
abstract::The tortuosity of retinal blood vessels is an important diagnostic indicator for a number of retinal pathologies. We applied robust quantitative tortuosity metrics, which are well suited to automated detection and measurement, to retinal fluorescein images of normal and diseased vessels exhibiting background diabetic ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0559-4
更新日期:2010-01-01 00:00:00
abstract::In the PREVENIR-5 study, artificial neural networks (NN) were applied to a large sample of patients with recent first acute coronary syndrome (ACS) to identify determinants of persistence of evidence-based cardiovascular medications (EBCM: antithrombotic + beta-blocker + statin + angiotensin converting enzyme inhibito...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-011-0785-4
更新日期:2011-08-01 00:00:00
abstract::While matrix remodeling plays a key role in vascular physiology and pathology, the underlying mechanisms have remained incompletely understood. We studied the remodeling of collagen matrices by individual vascular smooth muscle cells (SMCs), clusters and monolayers. In addition, we focused on the contribution of trans...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-0916-6
更新日期:2012-07-01 00:00:00
abstract::Currently, simulations of the induced currents in the brain produced by transcranial magnetic stimulation (TMS) are used to elucidate the regions reached by stimuli. However, models commonly found in the literature are too general and neglect imperfections in the windings. Aiming to predict the stimulation sites in pa...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-020-02156-2
更新日期:2020-07-01 00:00:00
abstract::A hydrodynamic model for the part of the human arterial network below the renal arteries has been constructed using specially fabricated distensible tubes and a pulsatile pump to simulate an aortoiliac bypass. The experiments and the computer model indicated that no 'steal' occurred due to the insertion of the bypass ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02441802
更新日期:1993-11-01 00:00:00
abstract::When the rib cage and abdomen are compressed during cardiopulmonary resuscitation (CPR), the effect on intrathoracic pressure, and therefore on haemodynamics, cannot be quantitatively predicted without a physiologically based mathematical model of chest wall dynamics. Using such a model, we compared model simulations ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02441676
更新日期:1990-01-01 00:00:00
abstract::The long QT syndrome (LQTS) is a genetic disorder, typically characterized by a prolonged QT interval in the ECG due to abnormal cardiac repolarization. LQTS may lead to syncopal episodes and sudden cardiac death. Various parameters based on T-wave morphology, as well as the QT interval itself have been shown to be us...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-006-0061-1
更新日期:2006-07-01 00:00:00
abstract::A computer-controlled pump for use both in the study of vascular haemodynamics and in the calibration of clinical devices which measure blood flow is designed. The novel design of this pump incorporates two rack-mounted pistons, driven into opposing cylinders by a micro-stepping motor. This approach allows the product...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02446086
更新日期:1991-11-01 00:00:00
abstract::This article presents a stimulation control method using a uniaxial gyroscope measuring angular velocity of the shank in the sagittal plane, to control functional electrical stimulation of the triceps surae to improve push-off of stroke subjects during gait. The algorithm is triggered during each swing phase of gait w...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0539-8
更新日期:2009-11-01 00:00:00
abstract::Greater trochanter (GT) stabilization techniques following a fracture or an osteotomy are still showing high levels of postoperative complications. Understanding the effect of femoral neck cut placement, cable tension and muscles forces on GT fragment displacements could help surgeons optimize their techniques. A 3D f...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-0892-x
更新日期:2012-04-01 00:00:00
abstract::An atlas-based multimodal registration method for 2-dimension images with discrepancy structures was proposed in this paper. Atlas was utilized for complementing the discrepancy structure information in multimodal medical images. The scheme includes three steps: floating image to atlas registration, atlas to reference...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-018-1808-1
更新日期:2018-11-01 00:00:00
abstract::Reactive hyperaemia is the term given to the temporary increase in blood flow that follows release of an occlusion of the arterial supply. Measurement of reactive hyperaemia in the leg below the knee is useful in assessment of the vascular system, as resting flows remain unaffected even in the presence of quite severe...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02515312
更新日期:1994-09-01 00:00:00
abstract::Using images from the Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI), we developed a methodology for classifying lung nodules. The proposed methodology uses image processing and pattern recognition techniques. To classify volumes of interest into nodules and non-nodules, we used shape mea...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-016-1582-x
更新日期:2017-08-01 00:00:00
abstract::The scapholunate ligament stabilizes the scaphoid and lunate of the proximal row in the wrist which allows for proper force transmission with the radius and ulna. Damage to this structure degenerates into arthritis and disability. Controversy exists over the best technique to restore function and reduce pain. A three-...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-01971-6
更新日期:2019-07-01 00:00:00
abstract::Hepatic echinococcosis (HE) is a life-threatening liver disease caused by parasites that requires a precise diagnosis and proper treatments. To assess HE lesions accurately, we propose a novel automatic HE lesion segmentation and classification network that contains lesion region positioning (LRP) and lesion region se...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-020-02126-8
更新日期:2020-03-01 00:00:00
abstract::Biomechanical models used to estimate joint loads often predict that antagonistic muscles are inactive or underestimate their contributions [3, 5]. This can result in systematic underestimation of muscle force predictions and joint contact forces. To test the feasibility of employing an empirical co-activation ratio t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-013-1081-2
更新日期:2014-03-01 00:00:00
abstract::Gait disturbances are common in the rat model of Parkinson's disease (PD) by administrating 6-hydroxydopamine. However, few studies have simultaneously assessed spatiotemporal gait indices and the kinematic information of PD rats during overground locomotion. This study utilized a simple, accurate, and reproducible me...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-0933-5
更新日期:2012-09-01 00:00:00
abstract::With the advent of biomedical imaging technology, the number of captured and stored biomedical images is rapidly increasing day by day in hospitals, imaging laboratories and biomedical institutions. Therefore, more robust biomedical image analysis technology is needed to meet the requirement of the diagnosis and class...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-018-1819-y
更新日期:2019-01-01 00:00:00