Control of triceps surae stimulation based on shank orientation using a uniaxial gyroscope during gait.

Abstract:

:This article presents a stimulation control method using a uniaxial gyroscope measuring angular velocity of the shank in the sagittal plane, to control functional electrical stimulation of the triceps surae to improve push-off of stroke subjects during gait. The algorithm is triggered during each swing phase of gait when the angular velocity of the shank is relatively high. Subsequently, the start of the stance phase is detected by a change of sign of the gyroscope signal at approximately the same time as heel strike. Stimulation is triggered when the shank angle reaches a preset value since the beginning of stance. The change of angle is determined by integrating angular velocity from the moment of change of sign. The results show that the real-time reliability of stimulation control was at least 95% for four of the five stroke subjects tested, two of which were 100% reliable. For the remaining subject, the reliability was increased from 50% found during the experiment, to 99% during offline processing. Our conclusion is that a uniaxial gyroscope on the shank is a simple, more reliable alternative to the heel switch for the purpose of restoring push-off of stroke subjects during gait.

journal_name

Med Biol Eng Comput

authors

Monaghan CC,van Riel WJ,Veltink PH

doi

10.1007/s11517-009-0539-8

subject

Has Abstract

pub_date

2009-11-01 00:00:00

pages

1181-8

issue

11

eissn

0140-0118

issn

1741-0444

journal_volume

47

pub_type

杂志文章
  • Single motor unit analysis from spatially filtered surface electromyogram signals. Part 2: conduction velocity estimation.

    abstract::The aim of the study was to compare experimentally conduction velocity (CV) estimates obtained with different estimation methods based on surface electromyogram (EMG) signals detected using five spatial filters. The filters investigated were the longitudinal single and double differential, transverse single and double...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348440

    authors: Schulte E,Farina D,Rau G,Merletti R,Disselhorst-Klug C

    更新日期:2003-05-01 00:00:00

  • PC/VAX or standalone PC-based general purpose biological data collection system.

    abstract::A system, to collect, analyse and display biological data, is developed using IBM PC AT compatibles (PCs) or CED1401/1609 devices networked to a VAX environment. It can be operated in three separate modes: using the CED/IEEE/VAX network; using the PC/Ethernet/VAX network; as a standalone PC. The original system compri...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446881

    authors: Marlow SP,Mackenzie DA,Tomlinson JB

    更新日期:1993-01-01 00:00:00

  • Functional evaluation of triceps surae during heel rise test: from EMG frequency analysis to machine learning approach.

    abstract::Soleus muscle flap as coverage tissue is a possible surgical solution adopted to cover the wounds due to open fractures. Despite this procedure presents many clinical advantages, relatively poor information is available about the loss of functionality of triceps surae of the treated leg. In this study, a group of pati...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02286-7

    authors: Ferracuti F,Fioretti S,Frontoni E,Iarlori S,Mengarelli A,Riccio M,Romeo L,Verdini F

    更新日期:2021-01-01 00:00:00

  • Validation of the non-stereo corresponding points stereoradiographic 3D reconstruction technique.

    abstract::Several 3D reconstruction techniques deriving from stereoradiographic DLT have been presented during the last 15 years, but these techniques have usually been limited in accuracy because of the small number of corresponding anatomical landmarks identified on both radiographs. A new technique has recently been proposed...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344797

    authors: Mitulescu A,Semaan I,De Guise JA,Leborgne P,Adamsbaum C,Skalli W

    更新日期:2001-03-01 00:00:00

  • A new method for measurement of motor unit action potential duration based on correlation, a pilot study.

    abstract::We present a new, automatic, correlation-based method for measuring the duration of motor unit action potentials (MUAPs). The method seeks to replicate the way an expert elctromyographer uses his or her eyes, calculating the start and end of the MUAP waveform on the basis of the degree of similarity of non-excluded di...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02115-6

    authors: Rodríguez Carreño I,Malanda A,Gila Useros L,Gurtubay IG,Navallas J,Rodríguez-Falces J

    更新日期:2020-03-01 00:00:00

  • Modeling the effect of tilting, passive leg exercise, and functional electrical stimulation on the human cardiovascular system.

    abstract::Long periods of bed rest negatively affect the human body organs, notably the cardiovascular system. To avert these negative effects and promote functional recovery in patients dealing with prolonged bed rest, the goal is to mobilize them as early as possible while controlling and stabilizing their cardiovascular syst...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1628-8

    authors: Sarabadani Tafreshi A,Okle J,Klamroth-Marganska V,Riener R

    更新日期:2017-09-01 00:00:00

  • Design and application of sensor for recording sounds over human eye and nose.

    abstract::The recording of sounds over the orbit of the eye has been found to be useful in the detection of intracranial aneurysms. A hydrophone for auscultation over the eye has been developed and is tested under controlled conditions. The tests consist of measurement over the eyes in three healthy volunteers at rest, during v...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02523031

    authors: Journée HL,van Bruggen AC,van der Meer JJ,de Jonge AB,Mooij JJ

    更新日期:1995-03-01 00:00:00

  • RETRACTED ARTICLE: Deep convolutional neural network-based speech enhancement to improve speech intelligibility and quality for hearing-impaired listeners.

    abstract:: ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,撤回出版物

    doi:10.1007/s11517-018-1933-x

    authors: Khaleelur Rahiman PF,Jayanthi VS,Jayanthi AN

    更新日期:2019-03-01 00:00:00

  • Noise reduction in magnetocardiography by singular value decomposition and independent component analysis.

    abstract::In the routine recording of magnetocardiograms (MCGs), it is necessary to underline the problem of noise cancellation. Source separation has often been suggested to solve this problem. In this paper, blind source separation (BSS), by means of singular value decomposition (SVD) and independent component analysis (ICA),...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0055-z

    authors: DiPietroPaolo D,Müller HP,Nolte G,Erné SN

    更新日期:2006-06-01 00:00:00

  • Angular relational signature-based chest radiograph image view classification.

    abstract::In a computer-aided diagnosis (CAD) system, especially for chest radiograph or chest X-ray (CXR) screening, CXR image view information is required. Automatically separating CXR image view, frontal and lateral can ease subsequent CXR screening process, since the techniques may not equally work for both views. We presen...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1786-3

    authors: Santosh KC,Wendling L

    更新日期:2018-08-01 00:00:00

  • A multi-electrode array and inversion technique for retrieving six conductivities from heart potential measurements.

    abstract::A method for accurately finding cardiac bidomain conductivity parameters is a crucial part of efforts to study and understand the electrical functioning of the heart. The bidomain model considers current flowing along (longitudinal) and across (transverse) sheets of cardiac fibres, as well as between these sheets (nor...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1101-2

    authors: Johnston BM,Johnston PR

    更新日期:2013-12-01 00:00:00

  • Effect of flow direction on the morphological responses of cultured bovine aortic endothelial cells.

    abstract::The effect of flow direction on the morphology of cultured bovine aortic endothelial cells is studied. Fully confluent endothelial cells cultured on glass were subjected to a fluid-imposed shear stress of 2 Pa for 20 min and 24 h using a parallel plate flow chamber. Experiments on shear flow exposure were performed fo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02522869

    authors: Kataoka N,Ujita S,Sato M

    更新日期:1998-01-01 00:00:00

  • Quantitative video-based gait pattern analysis for hemiparkinsonian rats.

    abstract::Gait disturbances are common in the rat model of Parkinson's disease (PD) by administrating 6-hydroxydopamine. However, few studies have simultaneously assessed spatiotemporal gait indices and the kinematic information of PD rats during overground locomotion. This study utilized a simple, accurate, and reproducible me...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0933-5

    authors: Lee HY,Hsieh TH,Liang JI,Yeh ML,Chen JJ

    更新日期:2012-09-01 00:00:00

  • Dialysate-side urea kinetics. Neural network predicts dialysis dose during dialysis.

    abstract::Determination of the adequacy of dialysis is a routine but crucial procedure in patient evaluation. The total dialysis dose, expressed as Kt/V, has been widely recognised to be a major determinant of morbidity and mortality in haemodialysed patients. Many different factors influence the correct determination of Kt/V, ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348080

    authors: Fernández EA,Valtuille R,Willshaw P,Perazzo CA

    更新日期:2003-07-01 00:00:00

  • Improvement of wireless power transmission efficiency of implantable subcutaneous devices by closed magnetic circuit mechanism.

    abstract::Induction coils were fabricated based on flexible printed circuit board for inductive transcutaneous power transmission. The coil had closed magnetic circuit (CMC) structure consisting of inner and outer magnetic core. The power transmission efficiency of the fabricated device was measured in the air and in vivo condi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0939-z

    authors: Jo SE,Joung S,Suh JK,Kim YJ

    更新日期:2012-09-01 00:00:00

  • Computer-assisted quantification of lung tumors in respiratory gated PET/CT images: phantom study.

    abstract::A computer-aided method was developed to automatically localize tumors in lung PET images of discrete bins within the breathing cycle, followed by an algorithm that registers all the information of a complete respiratory cycle into a single reference bin. Four registration/integration algorithms: Centroid Based, Inten...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0549-6

    authors: Wang J,del Valle M,Goryawala M,Franquiz JM,McGoron AJ

    更新日期:2010-01-01 00:00:00

  • Estimation of the lactate threshold using an electro acoustic sensor system analysing the respiratory air.

    abstract::The lactate threshold is used by athletes to optimise the intensity during exercise. It is of interest to measure the threshold on the very day and during the present sport activity. Steady state ergometer tests have been performed on 40 individuals to compare the threshold found by an electro acoustic sensor system t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0373-4

    authors: Folke M

    更新日期:2008-09-01 00:00:00

  • A novel finite element model-based navigation system-supported workflow for breast tumor excision.

    abstract::In the case of female breast cancer, a breast-conserving excision is often desirable. This surgery is based on preoperatively gathered MRI, mammography, and sonography images. These images are recorded in multiple patient positions, e. g., 2D mammography images in standing position with a compressed breast and 3D MRI ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01977-0

    authors: Esslinger D,Rapp P,Knödler L,Preibsch H,Tarín C,Sawodny O,Brucker SY,Hahn M

    更新日期:2019-07-01 00:00:00

  • Intelligent prediction of kinetic parameters during cutting manoeuvres.

    abstract::Due to its capabilities in analysing injury risk, the ability to analyse an athlete's ground reaction force and joint moments is of high interest in sports biomechanics. However, using force plates for the kinetic measurements influences the athlete's performance. Therefore, this study aims to use a feed-forward neura...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02000-2

    authors: Mundt M,David S,Koeppe A,Bamer F,Markert B,Potthast W

    更新日期:2019-08-01 00:00:00

  • Clinically oriented real-time monitoring of the individual's risk for deep tissue injury.

    abstract::Spinal cord injury patients are under daily risk for developing deep tissue injury which is a severe pressure ulcer that initiates in soft tissues at the bones' proximity. We aimed to formulate a patient-specific biomechanical model that can continuously monitor internal tissue stresses in real time. We adopted a form...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0754-y

    authors: Portnoy S,Vuillerme N,Payan Y,Gefen A

    更新日期:2011-04-01 00:00:00

  • Decreased global field synchronization of multichannel frontal EEG measurements in obsessive-compulsive disorders.

    abstract::Global field synchronization (GFS) quantifies the synchronization level of brain oscillations. The GFS method has been introduced to measure functional synchronization of EEG data in the frequency domain. GFS also detects phase interactions between EEG signals acquired from all of the electrodes. If a considerable amo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1689-8

    authors: Özçoban MA,Tan O,Aydin S,Akan A

    更新日期:2018-02-01 00:00:00

  • A unified treatment of the reference estimation problem in depth EEG recordings.

    abstract::The starting point of this paper is the analysis of the reference problem in intra-cerebral electroencephalographic (iEEG) recordings. It is well accepted that both surface and depth EEG signals are always recorded with respect to some unknown time-varying signal called reference. This article discusses different meth...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0946-0

    authors: Madhu N,Ranta R,Maillard L,Koessler L

    更新日期:2012-10-01 00:00:00

  • Effect of radiographic landmark identification errors on the accuracy of three-dimensional reconstruction of the human spine.

    abstract::In three-dimensional reconstruction of the human spine obtained from stereo-radiographic set-ups (two radiographs or more), it is extremely difficult to identify exactly the same landmarks on all radiographs. The effect of these identification errors was investigated with simulations made on points of known three-dime...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446787

    authors: André B,Dansereau J,Labelle H

    更新日期:1992-11-01 00:00:00

  • "Hippocrates-mst": a prototype for computer-aided microcalcification analysis and risk assessment for breast cancer.

    abstract::One of the most common cancer types among women is breast cancer. Regular mammographic examinations increase the possibility for early diagnosis and treatment and significantly improve the chance of survival for patients with breast cancer. Clustered microcalcifications have been considered as important indicators of ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0117-2

    authors: Spyrou G,Kapsimalakou S,Frigas A,Koufopoulos K,Vassilaros S,Ligomenides P

    更新日期:2006-11-01 00:00:00

  • Dielectric relaxation of a protein-water system in atherosclerotic artery wall.

    abstract::Measurements of the dielectric properties of healthy and atherosclerotic human artery tissues were made in the frequency range of 100 Hz-100 kHz and temperatures from 22 to 260 degrees C. The temperature dependencies of the dielectric parameters for healthy tissues reveal distinctively the temperature ranges correspon...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0181-2

    authors: Brzeziński J,Oszkinis G,Marzec E

    更新日期:2007-06-01 00:00:00

  • Evaluation of range of motion restriction within the hip joint.

    abstract::In total hip arthroplasty, determining the impingement free range of motion requirement is a complex task. This is because in the native hip, motion is restricted by both impingement as well as soft tissue restraint. The aim of this study is to determine a range of motion benchmark which can identify motions which are...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-1016-3

    authors: Turley GA,Williams MA,Wellings RM,Griffin DR

    更新日期:2013-04-01 00:00:00

  • Fully coupled fluid-structure interaction model of congenital bicuspid aortic valves: effect of asymmetry on hemodynamics.

    abstract::A bicuspid aortic valve (BAV) is a congenital cardiac disorder where the valve consists of only two cusps instead of three, as in a normal tricuspid valve (TAV). Although 97 % of BAVs include asymmetric cusps, little or no prior studies have investigated the blood flow through a three-dimensional BAV and root. The aim...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1055-4

    authors: Marom G,Kim HS,Rosenfeld M,Raanani E,Haj-Ali R

    更新日期:2013-08-01 00:00:00

  • Efficient and robust estimation of blood oxygenation levels in single cerebral veins.

    abstract::Blood oxygenation level is an important measure that can be used alongside functional magnetic resonance imaging data in order to obtain closer correlates of neuronal activation. A robust estimate of this measure has thus far not been demonstrated. This is mainly due to the lack of knowledge of the underlying paramete...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0886-8

    authors: Dagher J,Du YP

    更新日期:2012-05-01 00:00:00

  • Thermal distribution analysis of three-dimensional tumor-embedded breast models with different breast density compositions.

    abstract::Breast cancer is the most common cancer among women globally, and the number of young women diagnosed with this disease is gradually increasing over the years. Mammography is the current gold-standard technique although it is known to be less sensitive in detecting tumors in woman with dense breast tissue. Detecting a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1403-7

    authors: Wahab AA,Salim MI,Ahamat MA,Manaf NA,Yunus J,Lai KW

    更新日期:2016-09-01 00:00:00

  • Cumulant-based trapezoidal basis selection for heart sound classification.

    abstract::Past decades witnessed the expansion of linear signal processing methods in numerous biomedical applications. However, the nonlinear behavior of biomedical signals revived the interest in nonlinear signal processing methods such as higher-order statistics, in particular higher-order cumulants (HOC). In this paper, HOC...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1394-4

    authors: Safara F

    更新日期:2015-11-01 00:00:00