Abstract:
:A computer-controlled pump for use both in the study of vascular haemodynamics and in the calibration of clinical devices which measure blood flow is designed. The novel design of this pump incorporates two rack-mounted pistons, driven into opposing cylinders by a micro-stepping motor. This approach allows the production of nearly uninterrupted steady flow, as well as a variety of pulsatile waveforms, including waveforms with reverse flow. The capabilities of this pump to produce steady flow from 0.1 to 60 ml s-1, as well as sinusoidal flow and physiological flow, such as that found in the common femoral and common carotid arteries are demonstrated. Cycle-to-cycle reproducibility is very good, with an average variation of 0.1 ml s-1 over thousands of cycles.
journal_name
Med Biol Eng Computjournal_title
Medical & biological engineering & computingauthors
Holdsworth DW,Rickey DW,Drangova M,Miller DJ,Fenster Adoi
10.1007/BF02446086subject
Has Abstractpub_date
1991-11-01 00:00:00pages
565-70issue
6eissn
0140-0118issn
1741-0444journal_volume
29pub_type
杂志文章abstract::A technique is proposed that allows automatic decomposition of electromyographic (EMG) signals into their constituent motor unit action potential trains (MUAPTs). A specific iterative algorithm with a classification method using fuzzy-logic techniques was developed. The proposed classification method takes into accoun...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02349972
更新日期:2003-11-01 00:00:00
abstract::Even though the World Health Organization criteria's for classifying the dengue infection have been used for long time, recent studies declare that several difficulties have been faced by the clinicians to apply these criteria. Accordingly, many studies have proposed modified criteria to identify the risk in dengue pa...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0561-x
更新日期:2010-03-01 00:00:00
abstract::Left ventricular volume calibration based on the conductance catheter depends on the correct determination of the parallel conductance (Gp). Baan's saline manoeuvre procedure leads to Gp by finding the end-systolic (Ges) and end-diastolic (Ged) conductances, for each beat of the dilution curve rising limb. After plott...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02513284
更新日期:1999-03-01 00:00:00
abstract::The aim of the study was to assess the wavelength dependence of the UV absorbance during monitoring of different compounds in the dialysate. UV absorbance was determined by using a double-beam spectrophotometer on dialysate samples taken at pre-determined times during dialysis, over a wavelength range of 180-380 nm. C...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02348430
更新日期:2003-05-01 00:00:00
abstract::Haematocrit and temperature effects on resistivity are investigated using the electrical impedance method. Measurements are made extensively for pig's blood. The experimental set-up basically involves four ring electrodes being placed around a wooden probe that is subsequently immersed into a syringe containing pig's ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02523215
更新日期:1998-07-01 00:00:00
abstract::Remote patient monitoring should reduce mortality rates, improve care, and reduce costs. We present an overview of the available technologies for the remote monitoring of chronic obstructive pulmonary disease (COPD) patients, together with the most important medical information regarding COPD in a language that is ada...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-018-1798-z
更新日期:2018-04-01 00:00:00
abstract::We investigate a new framework of surgical instrument detection based on power-varying ultrasound images with simple and efficient pixel-wise intensity processing. Without using complicated feature extraction methods, we identified the instrument with an estimated optimal power level and by comparing pixel values of v...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-017-1695-x
更新日期:2018-03-01 00:00:00
abstract::In common radiography, image contrast is often limited due mainly to scattered x-rays and noise, decreasing the quantitative usefulness of x-ray images. Several scatter reduction methods based on software correction schemes have been extensively investigated in an attempt to overcome these difficulties, most of which ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-018-1893-1
更新日期:2019-02-01 00:00:00
abstract::Past decades witnessed the expansion of linear signal processing methods in numerous biomedical applications. However, the nonlinear behavior of biomedical signals revived the interest in nonlinear signal processing methods such as higher-order statistics, in particular higher-order cumulants (HOC). In this paper, HOC...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1394-4
更新日期:2015-11-01 00:00:00
abstract::Full-night polysomnography (PSG) has been recognized as the gold standard test for sleep apnea-hypopnea syndrome (SAHS). However, PSG examinees are physically restrained for the full night by many contact sensors and obtrusive connecting cables, inducing mental stress. We developed a non-contact SAHS diagnostic system...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1370-z
更新日期:2016-05-01 00:00:00
abstract::In the present study, well known scale-space filtering (SSF) algorithm is used in combination with a linear mapping approach (LMA) to obtain clear auditory evoked potential (EP) waveform. The proposed combination involves two sequential steps: At first, the EEG noise level is reduced from -5 to 0 dB owing to the LMA b...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0450-3
更新日期:2009-04-01 00:00:00
abstract::It is clinically well-established that minimally invasive subcutaneous continuous glucose monitoring (CGM) sensors can significantly improve diabetes treatment. However, CGM readings are still not as reliable as those provided by standard fingerprick blood glucose (BG) meters. In addition to unavoidable random measure...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-014-1226-y
更新日期:2015-12-01 00:00:00
abstract::This article presents a novel approach of edged and edgeless object-shape recognition and 3D reconstruction from gradient-based analysis of tactile images. We recognize an object's shape by visualizing a surface topology in our mind while grasping the object in our palm and also taking help from our past experience of...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-014-1142-1
更新日期:2014-04-01 00:00:00
abstract::The scapholunate ligament stabilizes the scaphoid and lunate of the proximal row in the wrist which allows for proper force transmission with the radius and ulna. Damage to this structure degenerates into arthritis and disability. Controversy exists over the best technique to restore function and reduce pain. A three-...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-01971-6
更新日期:2019-07-01 00:00:00
abstract::The Pennes bioheat equation and finite element method (FEM) are used to solve for the temperature distributions in the spinal cord and cerebrospinal fluid (CSF) during 30 min of cooling for spinal cord injury (SCI) patients. The average CSF and spinal cord temperatures are reduced by 3.48 and 2.72 degrees C, respectiv...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0543-z
更新日期:2010-02-01 00:00:00
abstract::Modern pacemakers (implantable devices used for maintaining an appropriate heart rate in patients) can use an intracardiac ventricular impedance signal for physiological cardiac stimulation control. Intracardiac ventricular impedance from nine animal subjects is analysed and presented (seven sheep: 49.0 +/- 6.5 kg, si...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345448
更新日期:2002-09-01 00:00:00
abstract::Sealing resistance is highly significant with respect to the electrical neuron-electrode contact because it decreases the stimulation threshold of neurons cultured on a planar micro-electrode array. A method is proposed for measurement of the sealing resistance using impedance spectroscopy. The effect of the sealing r...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02524436
更新日期:1998-09-01 00:00:00
abstract::Greater trochanter (GT) stabilization techniques following a fracture or an osteotomy are still showing high levels of postoperative complications. Understanding the effect of femoral neck cut placement, cable tension and muscles forces on GT fragment displacements could help surgeons optimize their techniques. A 3D f...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-0892-x
更新日期:2012-04-01 00:00:00
abstract::A multichannel biopotential amplifier for simultaneous use with biomagnetic measurements in a magnetically shielded room is designed and evaluated. Particular care is taken to make the amplifier electromagnetically compatible with the biomagnetic instruments over the whole frequency spectrum, from DC to RF. The electr...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02534098
更新日期:1997-07-01 00:00:00
abstract::A system is presented for the recording of physiological signals on an unmodified domestic videocassette recorder (VCR). A modification in the vertical synchronism pulses permits the recording of continuous analogue signals without significant loss of samples. The system allows up to 16 input channels, with a maximum ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02447101
更新日期:1991-03-01 00:00:00
abstract::The propagation of waves in the arteries is generally described using Fourier analysis in terms of periodic wavetrains formed by the superposition of a mean value and sinusoidal waves at the fundamental frequency (defined by the heart rate) and its harmonics. There is, however, an alternative way to describe waves in ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-008-0403-2
更新日期:2009-02-01 00:00:00
abstract::Currently, simulations of the induced currents in the brain produced by transcranial magnetic stimulation (TMS) are used to elucidate the regions reached by stimuli. However, models commonly found in the literature are too general and neglect imperfections in the windings. Aiming to predict the stimulation sites in pa...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-020-02156-2
更新日期:2020-07-01 00:00:00
abstract::The aim of this study was to design a new approach for the acquisition of regional radial strain from the middle portion of the interventricular septum. We designed and wrote a program in Matlab (computer-assisted method) for use on a personal computer so that the septum thickness throughout the cardiac cycle could be...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-007-0222-x
更新日期:2007-09-01 00:00:00
abstract::It is of great importance to effectively process and interpret surface electromyogram (sEMG) signals to actuate a robotic and prosthetic exoskeleton hand needed by hand amputees. In this paper, we have proposed a cepstrum analysis-based method for classification of basic hand movement sEMG signals. Cepstral analysis t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02024-8
更新日期:2019-10-01 00:00:00
abstract::The first in vivo evaluation of a pO2 sensor constructed with a novel copolymer is described. The performance of the sensor is assessed under dynamic conditions in vitro and in vivo. This sensor is more stable and reliable than the control sensor with a heparin-treated polyethylene membrane. ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02511245
更新日期:1996-07-01 00:00:00
abstract::The recording of sounds over the orbit of the eye has been found to be useful in the detection of intracranial aneurysms. A hydrophone for auscultation over the eye has been developed and is tested under controlled conditions. The tests consist of measurement over the eyes in three healthy volunteers at rest, during v...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02523031
更新日期:1995-03-01 00:00:00
abstract::Significant efforts were invested during the last decade to accelerate PET list-mode reconstructions, notably with GPU devices. However, the computation time per event is still relatively long, and the list-mode efficiency on the GPU is well below the histogram-mode efficiency. Since list-mode data are not arranged in...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1284-9
更新日期:2015-09-01 00:00:00
abstract::The magnitude, mismatch and temporal variations of the electrode-gel-skin interface impedance can cause problems in electrical impedance tomography (EIT) measurement. It is shown that at the high frequencies generally encountered in EIT the capacitive properties of the electrode interface, and especially those of the ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/BF02523842
更新日期:1996-11-01 00:00:00
abstract::Instrumentation to measure accurately the stresses at the interface of a residual limb and prosthetic socket has a strong potential for use in prosthetic treatment. As a tool in the clinical setting, the device would allow a clinician to identify sites of excessive loading, information which could then be combined wit...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/BF02522507
更新日期:1995-07-01 00:00:00
abstract::The paper describes an investigation in which it is shown that small positive voltage pulses applied to an external conductor placed against the photocathode of a photomultiplier tube can be used to switch the photocathode completely off for the duration of the pulses. This suggests that a photomultiplier tube with a ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02441486
更新日期:1989-05-01 00:00:00