Obtaining accurate and calibrated coil models for transcranial magnetic stimulation using magnetic field measurements.

Abstract:

:Currently, simulations of the induced currents in the brain produced by transcranial magnetic stimulation (TMS) are used to elucidate the regions reached by stimuli. However, models commonly found in the literature are too general and neglect imperfections in the windings. Aiming to predict the stimulation sites in patients requires precise modeling of the electric field (E-field), and a proper calibration to adequate to the empirical data of the particular coil employed. Furthermore, most fabricators do not provide precise information about the coil geometries, and even using X-ray images may lead to subjective interpretations. We measured the three components of the vector magnetic field induced by a TMS figure-8 coil with spatial resolutions of up to 1 mm. Starting from a computerized tomography-based coil model, we applied a multivariate optimization algorithm to automatically modify the original model and obtain one that optimally fits the measurements. Differences between models were assessed in a human brain mesh using the finite-elements method showing up to 6% variations in the E-field magnitude. Our calibrated model could increase the precision of the estimated E-field induced in the brain during TMS, enhance the accuracy of delivered stimulation during functional brain mapping, and improve dosimetry for repetitive TMS. Graphical Abstract Geometrical model of TMS coil based on TAC images is optimally deformed to match magnetic field measurements. The calibrated model's induced electric field in the brain differs from the original.

journal_name

Med Biol Eng Comput

authors

Mancino AV,Milano FE,Bertuzzi FM,Yampolsky CG,Ritacco LE,Risk MR

doi

10.1007/s11517-020-02156-2

subject

Has Abstract

pub_date

2020-07-01 00:00:00

pages

1499-1514

issue

7

eissn

0140-0118

issn

1741-0444

pii

10.1007/s11517-020-02156-2

journal_volume

58

pub_type

杂志文章
  • Internal work estimation in three-dimensional gait analysis.

    abstract::Many studies concerning the internal work of human motion have used two-dimensional kinematic models to estimate kinetic energy of the segments. The generalised co-ordinate concept has been applied here to a simultaneous and bilateral gait analysis. A three-dimensional kinematic model based on quaternions has been dev...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02523852

    authors: Aissaoui R,Allard P,Junqua A,Frossard L,Duhaime M

    更新日期:1996-11-01 00:00:00

  • Multiscale entropy-based approach to automated surface EMG classification of neuromuscular disorders.

    abstract::We introduce a novel method for an automatic classification of subjects to those with or without neuromuscular disorders. This method is based on multiscale entropy of recorded surface electromyograms (sEMGs) and support vector classification. The method was evaluated on a single-channel experimental sEMGs recorded fr...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0629-7

    authors: Istenic R,Kaplanis PA,Pattichis CS,Zazula D

    更新日期:2010-08-01 00:00:00

  • Myo-electric signals to augment speech recognition.

    abstract::It is proposed that myo-electric signals can be used to augment conventional speech-recognition systems to improve their performance under acoustically noisy conditions (e.g. in an aircraft cockpit). A preliminary study is performed to ascertain the presence of speech information within myo-electric signals from facia...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345373

    authors: Chan AD,Englehart K,Hudgins B,Lovely DF

    更新日期:2001-07-01 00:00:00

  • Development of automatized new indices for radiological assessment of chest-wall deformity and its quantitative evaluation.

    abstract::Pre-operative diagnosis of chest-wall deformity is important for successful surgical correction and post-operative evaluation of funnel chest patients. However, conventional indices that define the severity of deformity have several limitations; manually calculated and cannot supply information about asymmetry. We dev...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0367-2

    authors: Kim HC,Park HJ,Ham SY,Nam KW,Choi SY,Oh JS,Choi H,Jeong GS,Park SW,Kim MG,Sun K

    更新日期:2008-08-01 00:00:00

  • Pulsatile blood flow in total cavopulmonary connection: a comparison between Y-shaped and T-shaped geometry.

    abstract::Single-ventricle anomaly is a hereditary heart disease that is characterized by anatomical malformations. The main consequence of this malformation is desaturated blood flow, which without proper treatment increases the risk of death. The classical treatment is based on a three-stage palliative procedure which should ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1499-4

    authors: Rajabzadeh-Oghaz H,Firoozabadi B,Saidi MS,Monjezi M,Navabi Shirazi MA,Malakan Rad E

    更新日期:2017-02-01 00:00:00

  • Visualisation method of spatial interictal discharges in temporal epilepsy patients using magneto-encephalogram.

    abstract::The aim of the study was to develop a method for investigating how interictal epileptic discharges in temporal epilepsy patients are activated spatially. The activity was measured using magneto-encephalography (MEG). The MEG data were used to produce a current-arrow map that reflected the topographic distribution of t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344215

    authors: Kandori A,Oe H,Miyashita K,Date H,Yamada N,Naritomi H,Chiba Y,Murakami M,Miyashita T,Tsukada K

    更新日期:2002-05-01 00:00:00

  • Activating function of needle electrodes in anisotropic tissue.

    abstract::We present an analytical solution for the electrical potential and activating function (AF) established by cylindrical needle electrodes in anisotropic tissue. We compare this activating function to (1) AF computed assuming line-source electrodes and (2) AF computed using a finite element program. The results show tha...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0508-2

    authors: Guo L,Cranford JP,Neu JC,Neu WK

    更新日期:2009-09-01 00:00:00

  • Cumulant-based trapezoidal basis selection for heart sound classification.

    abstract::Past decades witnessed the expansion of linear signal processing methods in numerous biomedical applications. However, the nonlinear behavior of biomedical signals revived the interest in nonlinear signal processing methods such as higher-order statistics, in particular higher-order cumulants (HOC). In this paper, HOC...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1394-4

    authors: Safara F

    更新日期:2015-11-01 00:00:00

  • Effect of the shape and configuration of smooth muscle cells on the diffusion of ATP through the arterial wall.

    abstract::In this study, the shape and the configuration of smooth muscle cells (SMCs) within the arterial wall are altered to investigate their influence on molecular transport across the media layer of the thoracic aorta wall. In a 2D geometry of the media layer containing SMCs, the finite-element method has been employed to ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0219-5

    authors: Dabagh M,Jalali P,Sarkomaa P

    更新日期:2007-11-01 00:00:00

  • Repolarization variability independent of heart rate during sympathetic activation elicited by head-up tilt.

    abstract::The fraction of repolarization variability independent of RR interval variability is of clinical interest. It has been linked to direct autonomic nervous system (ANS) regulation of the ventricles in healthy subjects and seems to reflect the instability of the ventricular repolarization process in heart disease. In thi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01998-9

    authors: El-Hamad F,Javorka M,Czippelova B,Krohova J,Turianikova Z,Porta A,Baumert M

    更新日期:2019-08-01 00:00:00

  • Regulation of neurofilament interactions in vitro by natural and synthetic polypeptides sharing Lys-Ser-Pro sequences with the heavy neurofilament subunit NF-H: neurofilament crossbridging by antiparallel sidearm overlapping.

    abstract::Neurofilaments are organised into parallel bundles in axons through crossbridges formed by lateral projections of neurofilament subunits. Pure neurofilaments form gels in vitro, consisting of interconnected parallel arrays of filaments regulated by the phosphorylation level of neurofilament subunits. Neurofilament-ass...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02522486

    authors: Gou JP,Gotow T,Janmey PA,Leterrier JF

    更新日期:1998-05-01 00:00:00

  • EEG artifacts reduction by multivariate empirical mode decomposition and multiscale entropy for monitoring depth of anaesthesia during surgery.

    abstract::Electroencephalography (EEG) has been widely utilized to measure the depth of anaesthesia (DOA) during operation. However, the EEG signals are usually contaminated by artifacts which have a consequence on the measured DOA accuracy. In this study, an effective and useful filtering algorithm based on multivariate empiri...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1598-2

    authors: Liu Q,Chen YF,Fan SZ,Abbod MF,Shieh JS

    更新日期:2017-08-01 00:00:00

  • Development of an eye-movement analyser possessing functions for wireless transmission and autocalibration.

    abstract::An eye pointer was developed as a new line-of-sight displacement analyser. It analyses an observer's eye movements and superimposes their line of vision on a TV image which is the same as their view. A newly developed miniature colour field camera and very compact eye-movement sensors are attached to a translucent rei...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446149

    authors: Yamada M,Fukuda T,Hirota M

    更新日期:1990-07-01 00:00:00

  • Improved photomultiplier tube for positron emission tomography.

    abstract::The paper describes an investigation in which it is shown that small positive voltage pulses applied to an external conductor placed against the photocathode of a photomultiplier tube can be used to switch the photocathode completely off for the duration of the pulses. This suggests that a photomultiplier tube with a ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441486

    authors: Woldeselassie T

    更新日期:1989-05-01 00:00:00

  • Evaluation of feature extraction techniques and classifiers for finger movement recognition using surface electromyography signal.

    abstract::Electromyography (EMG) in a bio-driven system is used as a control signal, for driving a hand prosthesis or other wearable assistive devices. Processing to get informative drive signals involves three main modules: preprocessing, dimensionality reduction, and classification. This paper proposes a system for classifyin...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1857-5

    authors: Phukpattaranont P,Thongpanja S,Anam K,Al-Jumaily A,Limsakul C

    更新日期:2018-12-01 00:00:00

  • Effective identification and localization of immature precursors in bone marrow biopsy.

    abstract::Abnormal localization of immature precursors (ALIP) aggregating and clustering in bone marrow biopsy appears earlier than that of bone marrow smears in detection of the relapse of acute myelocytic leukemia (AML). But traditional manual ALIP recognition has many shortcomings such as prone to false alarms, neglect of di...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1223-1

    authors: Cao G,Li L,Chen W,Yu Y,Shi J,Zhang G,Liu X

    更新日期:2015-03-01 00:00:00

  • A catheter tactile sensor for measuring hardness of soft tissue: measurement in a silicone model and in an in vitro human prostate model.

    abstract::Tissue hardness is related to tissue composition, and this is often changed by disease. It is therefore of interest to measure the hardness in an objective and non-invasive way. A tactile sensor based on a vibrating piezoelectric ceramic element in a feedback loop is described. When the sensor touches an object it pro...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513357

    authors: Eklund A,Bergh A,Lindahl OA

    更新日期:1999-09-01 00:00:00

  • The Pocket Speech Aid.

    abstract::A rapid-access but limited vocabulary communication aid for the non-vocal and speech impaired is useful in some well defined situations. The design and construction of such a device is described. Three distinct situations have been identified where an aid is essential and an initial evaluation has shown the Pocket Spe...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441487

    authors: Keating D,Smith DC,Evans AL,Wyper DJ,Cunningham E

    更新日期:1989-05-01 00:00:00

  • Estimation of respiratory volumes from the photoplethysmographic signal. Part I: Experimental results.

    abstract::To evaluate the possibility of respiratory-volume measurement using photoplethysmography (PPG), PPG signals from 16 normal volunteers are collected, and the respiratory-induced intensity variations (RIIV) are digitally extracted. The RIIV signals are studied while respiratory volume is varied. Furthermore, respiratory...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513264

    authors: Johansson A,Oberg PA

    更新日期:1999-01-01 00:00:00

  • Improved performance of intravascular pO2 sensor incorporating poly(MPC-co-BMA) membrane.

    abstract::The first in vivo evaluation of a pO2 sensor constructed with a novel copolymer is described. The performance of the sensor is assessed under dynamic conditions in vitro and in vivo. This sensor is more stable and reliable than the control sensor with a heparin-treated polyethylene membrane. ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02511245

    authors: Zhang S,Wright G,Kingston MA,Rolfe P

    更新日期:1996-07-01 00:00:00

  • Hip implant performance prediction by acoustic emission techniques: a review.

    abstract::Nowadays, acoustic emission (AE) has its applications in various areas, including mechanical, civil, underwater acoustics, and biomedical engineering. It is a non-destructive evaluation (NDE) and a non-intrusive method to detect active damage mechanisms such as crack growth, delamination, and processes such as frictio...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-020-02202-z

    authors: Remya AR,Vishwash B,Lee C,Pai PS,Espinoza Oras AA,Ozevin D,Mathew MT

    更新日期:2020-08-01 00:00:00

  • Thermal distribution analysis of three-dimensional tumor-embedded breast models with different breast density compositions.

    abstract::Breast cancer is the most common cancer among women globally, and the number of young women diagnosed with this disease is gradually increasing over the years. Mammography is the current gold-standard technique although it is known to be less sensitive in detecting tumors in woman with dense breast tissue. Detecting a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1403-7

    authors: Wahab AA,Salim MI,Ahamat MA,Manaf NA,Yunus J,Lai KW

    更新日期:2016-09-01 00:00:00

  • Investigating body motion patterns in patients with Parkinson's disease using matching pursuit algorithm.

    abstract::Several recent studies have quantified abnormalities in Parkinsonian gait. However, few studies have attempted to quantify the regularity of body motion during walking in patients with Parkinson's disease. The aim of the paper was to characterise body motion patterns in healthy, elderly subjects and patients with Park...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02351008

    authors: Sekine M,Akay M,Tamura T,Higashi Y,Fujimoto T

    更新日期:2004-01-01 00:00:00

  • MicroPACS: a PC-based small PACS implementation.

    abstract::To make picture archiving and communication systems (PACS) a practical reality for small-scale structures, it appears necessary to build a network that integrates and optimises production management, analysis and storage of images, and to include the ability to communicate with other similar remote structures. To solv...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02458046

    authors: Duchêne J,Lerallut JF,Gong N,Kanz R

    更新日期:1993-05-01 00:00:00

  • Mechanisms governing the visco-elastic responses of living cells assessed by foam and tensegrity models.

    abstract::The visco-elastic properties of living cells, measured to date by various authors, vary considerably, depending on the experimental methods and/or on the theoretical models used. In the present study, two mechanisms thought to be involved in cellular visco-elastic responses were analysed, based on the idea that the cy...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02349982

    authors: Cañadas P,Laurent VM,Chabrand P,Isabey D,Wendling-Mansuy S

    更新日期:2003-11-01 00:00:00

  • Estimating normal and pathological dynamic responses in cerebral blood flow velocity to step changes in end-tidal pCO2.

    abstract::The regulation of cerebral blood flow (CBF) following changes in arterial blood pressure (ABP) and end-tidal pCO2 (EtCO2) are of clinical interest in assessing cerebrovascular reserve capacity. Linear finite-impulse-response modelling is applied to ABP, EtCO2 and CBF velocity (CBFV, from transcranial Doppler measureme...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345749

    authors: Simpson DM,Panerai RB,Evans DH,Garnham J,Naylor AR,Bell PR

    更新日期:2000-09-01 00:00:00

  • Application of mechanical mobility of periodontal tissues to tooth mobility examination.

    abstract::Tooth mobility examination is important in planning dental treatment, as it may give an indication of alveolar bone loss and the condition of the periodontal ligament. In clinical dental diagnosis a manual tooth mobility examination is useful. However, its determination of tooth mobility is subjective and depends on t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02442173

    authors: Oka H,Yamamoto T,Saratani K,Kawazoe T

    更新日期:1989-01-01 00:00:00

  • Estimation of single motor unit conduction velocity from surface electromyogram signals detected with linear electrode arrays.

    abstract::This work addresses the problem of estimating the conduction velocity (CV) of single motor unit (MU) action potentials from surface EMG signals detected with linear electrode arrays during voluntary muscle contractions. In ideal conditions, that is without shape or scale changes of the propagating signals and with add...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344807

    authors: Farina D,Muhammad W,Fortunato E,Meste O,Merletti R,Rix H

    更新日期:2001-03-01 00:00:00

  • Varying ultrasound power level to distinguish surgical instruments and tissue.

    abstract::We investigate a new framework of surgical instrument detection based on power-varying ultrasound images with simple and efficient pixel-wise intensity processing. Without using complicated feature extraction methods, we identified the instrument with an estimated optimal power level and by comparing pixel values of v...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1695-x

    authors: Ren H,Anuraj B,Dupont PE

    更新日期:2018-03-01 00:00:00

  • Finite element analysis of brain contusion: an indirect impact study.

    abstract::The mechanism of brain contusion has been investigated using a series of three-dimensional (3D) finite element analyses. A head injury model was used to simulate forward and backward rotation around the upper cervical vertebra. Intracranial pressure and shear stress responses were calculated and compared. The results ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02347044

    authors: Huang HM,Lee MC,Lee SY,Chiu WT,Pan LC,Chen CT

    更新日期:2000-05-01 00:00:00