New method using multi-regression analysis on evoked electromyography during movement to adjust stimulation conditions.

Abstract:

:A new method of stimulation of the lower extremities was devised that automatically adjusts the stimulation conditions at any angle of the knee joint. An M-wave is considered to indicate the stimulation conditions, because it is the waveform that results from direct stimulation to the axon of the alpha motor neuron. The present device adjusted the stimulation intensity, using multi-regression analysis to evoke an M-wave of preset amplitude. Participants included five people without any neuromuscular impairment. The subjects sat on a chair during the test. The hip joint was fixed at a flexion angle of 90 degrees, and the ankle joint was fixed at the midposition. During passive knee joint movement ranging from 0 degrees to 135 degrees, M-waves were measured. Electrodes were attached at the popliteal fossa and the patella to stimulate the tibial nerve. Ag-AgCl electrodes were put on the belly of the right soleus muscle for the M-wave measurement. The device was set to give M-waves close to the preset value, 10% Mmax. According to previous research, the allowable limit of M-wave amplitude deviations was reported to be about 5% Mmax. The M-wave amplitudes evoked by the device were in the allowable range (9.2 +/- 2.5% Mmax). The device enabled control of the M-wave amplitude over the entire range of motion of the joint. Using this device, it was possible to examine the excitability of the alpha motor neuron pool more precisely.

journal_name

Med Biol Eng Comput

authors

Tanabe S,Muraoka Y,Tomita Y

doi

10.1007/BF02351018

keywords:

subject

Has Abstract

pub_date

2004-01-01 00:00:00

pages

106-9

issue

1

eissn

0140-0118

issn

1741-0444

journal_volume

42

pub_type

杂志文章
  • ANN compression of morphologically similar ECG complexes.

    abstract::A compression algorithm for electrocardiogram signals is presented, based on an auto-associative neural network. Issues of weight and activation coding are considered, and compression performances of various network sizes are compared. A unique feature is the performance improvement achieved using DC level removal. A ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02523019

    authors: Hamilton DJ,Thomson DC,Sandham WA

    更新日期:1995-11-01 00:00:00

  • Effect of the shape and configuration of smooth muscle cells on the diffusion of ATP through the arterial wall.

    abstract::In this study, the shape and the configuration of smooth muscle cells (SMCs) within the arterial wall are altered to investigate their influence on molecular transport across the media layer of the thoracic aorta wall. In a 2D geometry of the media layer containing SMCs, the finite-element method has been employed to ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0219-5

    authors: Dabagh M,Jalali P,Sarkomaa P

    更新日期:2007-11-01 00:00:00

  • Estimation of dynamic metabolic activity in micro-tissue cultures from sensor recordings with an FEM model.

    abstract::We estimated the dynamic cell metabolic activity and the distribution of the pH value and oxygen concentration in tissue samples cultured in vitro by using real-time sensor records and a numerical simulation of the underlying reaction-diffusion processes. As an experimental tissue model, we used chicken spleen slices....

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1367-7

    authors: Pfister C,Forstmeier C,Biedermann J,Schermuly J,Demmel F,Wolf P,Kaspers B,Brischwein M

    更新日期:2016-05-01 00:00:00

  • Towards a patient-specific hepatic arterial modeling for microspheres distribution optimization in SIRT protocol.

    abstract::Selective internal radiation therapy (SIRT) using Yttrium-90 loaded glass microspheres injected in the hepatic artery is an emerging, minimally invasive therapy of liver cancer. A personalized intervention can lead to high concentration dose in the tumor, while sparing the surrounding parenchyma. We propose a computat...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1703-1

    authors: Simoncini C,Jurczuk K,Reska D,Esneault S,Nunes JC,Bellanger JJ,Saint-Jalmes H,Rolland Y,Eliat PA,Bézy-Wendling J,Kretowski M

    更新日期:2018-03-01 00:00:00

  • Monopole patch antenna for in vivo exposure to nanosecond pulsed electric fields.

    abstract::To explore the promising therapeutic applications of short nanosecond electric pulses, in vitro and in vivo experiments are highly required. In this paper, an exposure system based on monopole patch antenna is reported to perform in vivo experiments on newborn mice with both monopolar and bipolar nanosecond signals. A...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1547-0

    authors: Merla C,Apollonio F,Paffi A,Marino C,Vernier PT,Liberti M

    更新日期:2017-07-01 00:00:00

  • Beat-to-beat estimation of stroke volume using impedance cardiography and artificial neural network.

    abstract::Impedance cardiography is a low-cost noninvasive technique, based on monitoring of the thoracic impedance, for estimation of stroke volume (SV). Impedance cardiogram (ICG) is the negative of the first derivative of the impedance signal. A technique for beat-to-beat SV estimation using impedance cardiography and artifi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1752-5

    authors: Naidu SMM,Pandey PC,Bagal UR,Hardas SP

    更新日期:2018-06-01 00:00:00

  • Gabor filters and phase portraits for the detection of architectural distortion in mammograms.

    abstract::Architectural distortion is a subtle abnormality in mammograms, and a source of overlooking errors by radiologists. Computer-aided diagnosis (CAD) techniques can improve the performance of radiologists in detecting masses and calcifications; however, most CAD systems have not been designed to detect architectural dist...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0088-3

    authors: Rangayyan RM,Ayres FJ

    更新日期:2006-10-01 00:00:00

  • Quantitative measurement of Parkinsonian gait from walking in monocular image sequences using a centroid tracking algorithm.

    abstract::Parkinson's disease (PD) is a neurodegenerative disease of the central nervous system that results from the degeneration of dopaminergic neurons in the substantia nigra. Abnormal gait begins in the early stage and becomes severe as the disease progresses; therefore, the assessment of gait becomes an important issue in...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1335-2

    authors: Lin SH,Chen SW,Lo YC,Lai HY,Yang CH,Chen SY,Chang YJ,Chen CH,Huang WT,Jaw FS,Chen YY,Tsang S,Liao LD

    更新日期:2016-03-01 00:00:00

  • Urinary bladder volume tracking using a Kalman filter.

    abstract::This study introduced the Kalman filter procedure for tracking urinary bladder filling from intermittent bladder volume measurements taken by an ultrasonic bladder volume monitor. The Kalman filter was based on a double integrator as a model for the bladder filling process between micturitions and included a procedure...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345809

    authors: Kristiansen NK,Sjöström SO,Nygaard H

    更新日期:2005-05-01 00:00:00

  • Comparison of heart rate variability spectra using generic relationships of their input signals.

    abstract::Spectral analysis of heart rate variability (HRV) is an accepted method for assessment of cardiac autonomic function and its relationship to numerous disorders and diseases. Various non-parametric methods for HRV estimation have been developed. The spectrum of counts, the instantaneous heart rate spectrum and the inte...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02524426

    authors: Mitov IP,Daskalov IK

    更新日期:1998-09-01 00:00:00

  • A novel finite element model-based navigation system-supported workflow for breast tumor excision.

    abstract::In the case of female breast cancer, a breast-conserving excision is often desirable. This surgery is based on preoperatively gathered MRI, mammography, and sonography images. These images are recorded in multiple patient positions, e. g., 2D mammography images in standing position with a compressed breast and 3D MRI ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01977-0

    authors: Esslinger D,Rapp P,Knödler L,Preibsch H,Tarín C,Sawodny O,Brucker SY,Hahn M

    更新日期:2019-07-01 00:00:00

  • Analysis of implantable cardioverter defibrillator signals for non conventional cardiac electrical activity characterization.

    abstract::Implantable cardioverter defibrillators (ICDs) can store intracardiac electrograms (EGMs) in sinus rhythm (SR), at the onset of spontaneous ventricular tachyarrhythmias (VT) or during their course. This allows the investigation of unknown features of the heart electrical activity associated with different cardiac rhyt...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-005-0014-0

    authors: Casaleggio A,Rossi P,Faini A,Guidotto T,Malavasi V,Musso G,Sartori G

    更新日期:2006-03-01 00:00:00

  • Influence of ionic shifts during dialysis on volume estimations with multifrequency impedance analysis.

    abstract::During dialysis the ion concentrations in many body fluids change significantly. The influence of these changes on the accuracy of volume measurements with bioimpedance spectroscopy is investigated by the following procedure: Plasma ion concentrations and impedance spectra (5-500 kHz) are measured during six standard ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02534137

    authors: Scharfetter H,Wirnsberger GH,Holzer H,Hutten H

    更新日期:1997-03-01 00:00:00

  • Multiplane spectroscopic whole-body photoacoustic imaging of small animals in vivo.

    abstract::We have successfully developed a multiscale acoustic-resolution photoacoustic tomography system in a single imaging platform. By switching between ultrasound transducers (center frequencies 5 and 40 MHz) and optical condensers, we have photoacoustically imaged microvasculatures of small animals in vivo at different sc...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1182-6

    authors: Jeon M,Kim J,Kim C

    更新日期:2016-03-01 00:00:00

  • Pressures generated by rib cage and abdominal compressions during cardiopulmonary resuscitation.

    abstract::When the rib cage and abdomen are compressed during cardiopulmonary resuscitation (CPR), the effect on intrathoracic pressure, and therefore on haemodynamics, cannot be quantitatively predicted without a physiologically based mathematical model of chest wall dynamics. Using such a model, we compared model simulations ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441676

    authors: Ben-Haim SA,Shofti R,Dinnar U,Saidel GM

    更新日期:1990-01-01 00:00:00

  • A computer-assisted human peripheral blood leukocyte image classification method based on Siamese network.

    abstract::A computer-assisted human peripheral blood leukocyte image classification method based on Siamese network is proposed. Firstly, a Siamese network with two identical convolutional neural network (CNN) sub-networks and a logistic regression for leukocyte five classification is designed, which can learn not only distingu...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02180-2

    authors: Wang Y,Cao Y

    更新日期:2020-07-01 00:00:00

  • Computational prediction of the effects of the intra-aortic balloon pump on heart failure with valvular regurgitation using a 3D cardiac electromechanical model.

    abstract::Intra-aortic balloon pump (IABP) is normally contraindicated in significant aortic regurgitation (AR). It causes and aggravates pre-existing AR while performing well in the event of mitral regurgitation (MR). Indirect parameters, such as the mean systolic pressure, product of heart rate and peak systolic pressure, and...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1731-x

    authors: Kim CH,Song KS,Trayanova NA,Lim KM

    更新日期:2018-05-01 00:00:00

  • Obtaining accurate and calibrated coil models for transcranial magnetic stimulation using magnetic field measurements.

    abstract::Currently, simulations of the induced currents in the brain produced by transcranial magnetic stimulation (TMS) are used to elucidate the regions reached by stimuli. However, models commonly found in the literature are too general and neglect imperfections in the windings. Aiming to predict the stimulation sites in pa...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02156-2

    authors: Mancino AV,Milano FE,Bertuzzi FM,Yampolsky CG,Ritacco LE,Risk MR

    更新日期:2020-07-01 00:00:00

  • Measurement of retinal vascular tortuosity and its application to retinal pathologies.

    abstract::The tortuosity of retinal blood vessels is an important diagnostic indicator for a number of retinal pathologies. We applied robust quantitative tortuosity metrics, which are well suited to automated detection and measurement, to retinal fluorescein images of normal and diseased vessels exhibiting background diabetic ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0559-4

    authors: Dougherty G,Johnson MJ,Wiers MD

    更新日期:2010-01-01 00:00:00

  • Fluorescence microscopy image classification of 2D HeLa cells based on the CapsNet neural network.

    abstract::The development of computer technology now allows the quick and efficient automatic fluorescence microscopy generation of a large number of images of proteins in specific subcellular compartments using fluorescence microscopy. Digital image processing and pattern recognition technology can easily classify these images...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-01946-z

    authors: Zhang X,Zhao SG

    更新日期:2019-06-01 00:00:00

  • Evaluation of range of motion restriction within the hip joint.

    abstract::In total hip arthroplasty, determining the impingement free range of motion requirement is a complex task. This is because in the native hip, motion is restricted by both impingement as well as soft tissue restraint. The aim of this study is to determine a range of motion benchmark which can identify motions which are...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-1016-3

    authors: Turley GA,Williams MA,Wellings RM,Griffin DR

    更新日期:2013-04-01 00:00:00

  • A novel recursive Fourier transform for nonuniform sampled signals: application to heart rate variability spectrum estimation.

    abstract::We present a novel method to iteratively calculate discrete Fourier transforms for discrete time signals with sample time intervals that may be widely nonuniform. The proposed recursive Fourier transform (RFT) does not require interpolation of the samples to uniform time intervals, and each iterative transform update ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0461-0

    authors: Holland A,Aboy M

    更新日期:2009-07-01 00:00:00

  • Adaptive processing bandwidth adjustment for laser Doppler flowmetry.

    abstract::A novel laser Doppler flowmetry scheme is reported that adjusts the processing bandwidth adaptively to optimise the estimation of flow. To obtain an adequate processing bandwidth, the Doppler spectra is first fitted to the Lorentzian function, and the bandwidth at half the maximum of the Lorentzian function is used as...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344700

    authors: Chen YY,Lin YH,Jan IC,Liu RS,Chou NK,Jan GJ

    更新日期:2004-05-01 00:00:00

  • An adaptive enhancement method for breast X-ray images based on the nonsubsampled contourlet transform domain and whale optimization algorithm.

    abstract::We propose a new method for breast X-ray image adaptive enhancement that combines nonsubsampled contourlet transform (NSCT) with the whale optimization algorithm (WOA). First, the mammography X-ray image was processed by histogram equalization to ensure global image contrast. The processed image was then decomposed in...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02022-w

    authors: Zhang CJ,Nie HH

    更新日期:2019-10-01 00:00:00

  • Advanced computational workflow for the multi-scale modeling of the bone metabolic processes.

    abstract::Multi-scale modeling of the musculoskeletal system plays an essential role in the deep understanding of complex mechanisms underlying the biological phenomena and processes such as bone metabolic processes. Current multi-scale models suffer from the isolation of sub-models at each anatomical scale. The objective of th...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-016-1572-z

    authors: Dao TT

    更新日期:2017-06-01 00:00:00

  • Time-varying digital filtering of ECG baseline wander.

    abstract::Time-varying filtering techniques are applied to the problem of baseline correction by letting the cut-off frequency of a linear filter be controlled by the low-frequency properties of the ECG signal. The time-varying filter is implemented as a bank of linear low-pass filters, in which each filter has a slightly diffe...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441986

    authors: Sörnmo L

    更新日期:1993-09-01 00:00:00

  • Image-based state-of-the-art techniques for the identification and classification of brain diseases: a review.

    abstract::Detection and classification methods have a vital and important role in identifying brain diseases. Timely detection and classification of brain diseases enable an accurate identification and effective management of brain impairment. Brain disorders are commonly most spreadable diseases and the diagnosing process is t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-020-02256-z

    authors: Haq EU,Huang J,Kang L,Haq HU,Zhan T

    更新日期:2020-11-01 00:00:00

  • Mechanisms governing the visco-elastic responses of living cells assessed by foam and tensegrity models.

    abstract::The visco-elastic properties of living cells, measured to date by various authors, vary considerably, depending on the experimental methods and/or on the theoretical models used. In the present study, two mechanisms thought to be involved in cellular visco-elastic responses were analysed, based on the idea that the cy...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02349982

    authors: Cañadas P,Laurent VM,Chabrand P,Isabey D,Wendling-Mansuy S

    更新日期:2003-11-01 00:00:00

  • Extraction of Cole parameters from the electrical bioimpedance spectrum using stochastic optimization algorithms.

    abstract::Fitting the measured bioimpedance spectroscopy (BIS) data to the Cole model and then extracting the Cole parameters is a common practice in BIS applications. The extracted Cole parameters then can be analysed as descriptors of tissue electrical properties. To have a better evaluation of physiological or pathological p...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1355-y

    authors: Gholami-Boroujeny S,Bolic M

    更新日期:2016-04-01 00:00:00

  • Hip implant performance prediction by acoustic emission techniques: a review.

    abstract::Nowadays, acoustic emission (AE) has its applications in various areas, including mechanical, civil, underwater acoustics, and biomedical engineering. It is a non-destructive evaluation (NDE) and a non-intrusive method to detect active damage mechanisms such as crack growth, delamination, and processes such as frictio...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-020-02202-z

    authors: Remya AR,Vishwash B,Lee C,Pai PS,Espinoza Oras AA,Ozevin D,Mathew MT

    更新日期:2020-08-01 00:00:00