Comparison of heart rate variability spectra using generic relationships of their input signals.

Abstract:

:Spectral analysis of heart rate variability (HRV) is an accepted method for assessment of cardiac autonomic function and its relationship to numerous disorders and diseases. Various non-parametric methods for HRV estimation have been developed. The spectrum of counts, the instantaneous heart rate spectrum and the interval spectrum are mostly practised. Although extensive literature on their respective properties is available, there seems to be a need for a more complete comparison, eventually resulting in recommendations for applicability. The methods for HRV spectral analysis use their specific transforms of the primary R-R interval series into input signals for spectral computation. This is, in fact, the reason for obtaining different spectra. A basis for comparison is established, revealing the generic relationships of these HRV input signals. It allows for a more systematic evaluation and for further development of the considered methods. The results with simulated and real HRV data show better performance by the spectrum of counts and by a proposed instantaneous heart rate spectrum, obtained using a cubic spline interpolated input signal. The modulation depth of the primary signal can influence the accuracy of the HRV analysis methods.

journal_name

Med Biol Eng Comput

authors

Mitov IP,Daskalov IK

doi

10.1007/BF02524426

keywords:

subject

Has Abstract

pub_date

1998-09-01 00:00:00

pages

573-80

issue

5

eissn

0140-0118

issn

1741-0444

journal_volume

36

pub_type

杂志文章
  • Comparison between human awake, meditation and drowsiness EEG activities based on directed transfer function and MVDR coherence methods.

    abstract::This study examined the electroencephalogram functional connectivity (coherence) and effective connectivity (flow of information) of selected brain regions during three different attentive states: awake, meditation and drowsiness. For the estimation of functional connectivity (coherence), Welch and minimum variance di...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1272-0

    authors: Dissanayaka C,Ben-Simon E,Gruberger M,Maron-Katz A,Sharon H,Hendler T,Cvetkovic D

    更新日期:2015-07-01 00:00:00

  • Estimating normal and pathological dynamic responses in cerebral blood flow velocity to step changes in end-tidal pCO2.

    abstract::The regulation of cerebral blood flow (CBF) following changes in arterial blood pressure (ABP) and end-tidal pCO2 (EtCO2) are of clinical interest in assessing cerebrovascular reserve capacity. Linear finite-impulse-response modelling is applied to ABP, EtCO2 and CBF velocity (CBFV, from transcranial Doppler measureme...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345749

    authors: Simpson DM,Panerai RB,Evans DH,Garnham J,Naylor AR,Bell PR

    更新日期:2000-09-01 00:00:00

  • Parametric recursive system identification and self-adaptive modeling of the human energy metabolism for adaptive control of fat weight.

    abstract::A mathematical model has been developed to facilitate indirect measurements of difficult to measure variables of the human energy metabolism on a daily basis. The model performs recursive system identification of the parameters of the metabolic model of the human energy metabolism using the law of conservation of ener...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1552-3

    authors: Őri ZP

    更新日期:2017-05-01 00:00:00

  • A computerized volumetric segmentation method applicable to multi-centre MRI data to support computer-aided breast tissue analysis, density assessment and lesion localization.

    abstract::Density assessment and lesion localization in breast MRI require accurate segmentation of breast tissues. A fast, computerized algorithm for volumetric breast segmentation, suitable for multi-centre data, has been developed, employing 3D bias-corrected fuzzy c-means clustering and morphological operations. The full br...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1484-y

    authors: Ertas G,Doran SJ,Leach MO

    更新日期:2017-01-01 00:00:00

  • Feature extraction for on-line EEG classification using principal components and linear discriminants.

    abstract::The study focuses on the problems of dimensionality reduction by means of principal component analysis (PCA) in the context of single-trial EEG data classification (i.e. discriminating between imagined left- and right-hand movement). The principal components with the highest variance, however, do not necessarily carry...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02522476

    authors: Lugger K,Flotzinger D,Schlögl A,Pregenzer M,Pfurtscheller G

    更新日期:1998-05-01 00:00:00

  • Silicon-based microelectrodes for neurophysiology, micromachined from silicon-on-insulator wafers.

    abstract::A process is described for the fabrication of silicon-based microelectrodes for neurophysiology using bonded and etched-back silicon-on-insulator (BESOI) wafers. The probe shapes are defined without high levels of boron doping in the silicon; this is considered as a step towards producing probes with active electronic...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344773

    authors: Ensell G,Banks DJ,Richards PR,Balachandran W,Ewins DJ

    更新日期:2000-03-01 00:00:00

  • Sprouting from arteriovenous shunt vessels with increased blood flow.

    abstract::The purpose of this study was to evaluate the effect of increased blood flow on angiogenesis at the large vessels. The arteriovenous (AV) shunt was made on the thigh of male Wistar rats (n = 27) to increase blood flow, wrapped with artificial skin dermis, which consisted of a silicon outer layer, and isolated from sur...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345133

    authors: Asano Y,Ichioka S,Shibata M,Ando J,Nakatsuka T

    更新日期:2005-01-01 00:00:00

  • Noninvasive measurement of blood glucose concentrations by analysing Fourier transform infra-red absorbance spectra through oral mucosa.

    abstract::Whether Fourier transform infra-red spectroscopy with an attenuated total reflection prism could be applied for noninvasive glucose measurement through oral mucosa was evaluated. As a result, the same absorbance peak at 1033 cm-1 as in glucose aqueous solution was found in the absorbance spectra through mucous membran...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446645

    authors: Kajiwara K,Uemura T,Kishikawa H,Nishida K,Hashiguchi Y,Uehara M,Sakakida M,Ichinose K,Shichiri M

    更新日期:1993-07-01 00:00:00

  • The Pocket Speech Aid.

    abstract::A rapid-access but limited vocabulary communication aid for the non-vocal and speech impaired is useful in some well defined situations. The design and construction of such a device is described. Three distinct situations have been identified where an aid is essential and an initial evaluation has shown the Pocket Spe...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441487

    authors: Keating D,Smith DC,Evans AL,Wyper DJ,Cunningham E

    更新日期:1989-05-01 00:00:00

  • Mathematical model of tumor volume dynamics in mice treated with electrochemotherapy.

    abstract::The effectiveness of electrochemotherapy, a local treatment using electric pulses to increase the uptake of chemotherapeutic drug, includes several antitumor mechanisms. In addition to the cytotoxic action of chemotherapeutic drug, treatment outcome also depends on antitumor immune response. In order to assess the con...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1562-1

    authors: Forjanič T,Miklavčič D

    更新日期:2017-07-01 00:00:00

  • Influence of ionic shifts during dialysis on volume estimations with multifrequency impedance analysis.

    abstract::During dialysis the ion concentrations in many body fluids change significantly. The influence of these changes on the accuracy of volume measurements with bioimpedance spectroscopy is investigated by the following procedure: Plasma ion concentrations and impedance spectra (5-500 kHz) are measured during six standard ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02534137

    authors: Scharfetter H,Wirnsberger GH,Holzer H,Hutten H

    更新日期:1997-03-01 00:00:00

  • Development of automatized new indices for radiological assessment of chest-wall deformity and its quantitative evaluation.

    abstract::Pre-operative diagnosis of chest-wall deformity is important for successful surgical correction and post-operative evaluation of funnel chest patients. However, conventional indices that define the severity of deformity have several limitations; manually calculated and cannot supply information about asymmetry. We dev...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0367-2

    authors: Kim HC,Park HJ,Ham SY,Nam KW,Choi SY,Oh JS,Choi H,Jeong GS,Park SW,Kim MG,Sun K

    更新日期:2008-08-01 00:00:00

  • Haemodynamic model of a unilateral iliac stenosis with an aortoiliac bypass.

    abstract::A hydrodynamic model for the part of the human arterial network below the renal arteries has been constructed using specially fabricated distensible tubes and a pulsatile pump to simulate an aortoiliac bypass. The experiments and the computer model indicated that no 'steal' occurred due to the insertion of the bypass ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441802

    authors: Helal MA,Watts KC,Marble AE

    更新日期:1993-11-01 00:00:00

  • Fluorescence microscopy image classification of 2D HeLa cells based on the CapsNet neural network.

    abstract::The development of computer technology now allows the quick and efficient automatic fluorescence microscopy generation of a large number of images of proteins in specific subcellular compartments using fluorescence microscopy. Digital image processing and pattern recognition technology can easily classify these images...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-01946-z

    authors: Zhang X,Zhao SG

    更新日期:2019-06-01 00:00:00

  • Analysis of four methods of measuring three-dimensional pelvic tilt in the lateral decubitus position.

    abstract::Proper alignment of acetabular implantation is necessary for good patient outcomes and preventing complications or additional surgeries in total hip arthroplasty (THA). Rotation of the pelvis in lateral decubitus (LD) is typically not accounted for as surgeons use the surgery table as a reference plane to align implan...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02235-4

    authors: Stadnyk M,Liu T,Arezodar FF,Westover L,Carvajal Alba JA,Masson E,Beaupre L,Jaremko JL,El-Rich M

    更新日期:2020-10-01 00:00:00

  • Design and application of sensor for recording sounds over human eye and nose.

    abstract::The recording of sounds over the orbit of the eye has been found to be useful in the detection of intracranial aneurysms. A hydrophone for auscultation over the eye has been developed and is tested under controlled conditions. The tests consist of measurement over the eyes in three healthy volunteers at rest, during v...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02523031

    authors: Journée HL,van Bruggen AC,van der Meer JJ,de Jonge AB,Mooij JJ

    更新日期:1995-03-01 00:00:00

  • Elastic porous tube model of reactive hyperaemia.

    abstract::Reactive hyperaemia is the term given to the temporary increase in blood flow that follows release of an occlusion of the arterial supply. Measurement of reactive hyperaemia in the leg below the knee is useful in assessment of the vascular system, as resting flows remain unaffected even in the presence of quite severe...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02515312

    authors: Smye SW,Bloor MI

    更新日期:1994-09-01 00:00:00

  • Efficient and robust estimation of blood oxygenation levels in single cerebral veins.

    abstract::Blood oxygenation level is an important measure that can be used alongside functional magnetic resonance imaging data in order to obtain closer correlates of neuronal activation. A robust estimate of this measure has thus far not been demonstrated. This is mainly due to the lack of knowledge of the underlying paramete...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0886-8

    authors: Dagher J,Du YP

    更新日期:2012-05-01 00:00:00

  • CT analysis of the use of the electrical impedance technique to estimate local oedema in the extremities in patients with lymphatic obstruction.

    abstract::The aim of the study is to establish the validity of the use of the electrical impedance technique for estimating local oedema in extremities through comparison with computed-tomography (CT) analysis. Eight healthy women (group 1) and nine women with unilateral leg oedema following chronic lymphatic obstruction (group...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02522859

    authors: Watanabe R,Kotoura H,Morishita Y

    更新日期:1998-01-01 00:00:00

  • Registration and geometric modelling of the spine during scoliosis surgery: a comparison study of different pre-operative reconstruction techniques and intra-operative tracking systems.

    abstract::During scoliosis instrumentation surgery, it is difficult for surgeons fully to track vertebral motion in 3D, because only the posterior elements of the spine are exposed. Different intra-operative modelling approaches are evaluated using a registration technique that matches intra-operative measurements with a 3D pre...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513328

    authors: Mac-Thiong JM,Aubin CE,Dansereau J,de Guise JA,Brodeur P,Labelle H

    更新日期:1999-07-01 00:00:00

  • Combination of "generalized Trotter operator splitting" and "quadratic adaptive algorithm" method for tradeoff among speedup, stability, and accuracy in the Markov chain model of sodium ion channels in the ventricular cell model.

    abstract::The fast hybrid operator splitting (HOS) and stable uniformization (UNI) methods have been proposed to save computation cost and enhance stability for Markov chain model in cardiac cell simulations. Moreover, Chen-Chen-Luo's quadratic adaptive algorithm (CCL) combined with HOS or UNI was used to improve the tradeoff b...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02220-x

    authors: Chen XJ,Luo CH,Chen MH

    更新日期:2020-09-01 00:00:00

  • Usability of Computerized Lung Auscultation-Sound Software (CLASS) for learning pulmonary auscultation.

    abstract::The mastering of pulmonary auscultation requires complex acoustic skills. Computer-assisted learning tools (CALTs) have potential to enhance the learning of these skills; however, few have been developed for this purpose and do not integrate all the required features. Thus, this study aimed to assess the usability of ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1697-8

    authors: Machado A,Oliveira A,Jácome C,Pereira M,Moreira J,Rodrigues J,Aparício J,Jesus LMT,Marques A

    更新日期:2018-04-01 00:00:00

  • Delivery devices for exposure of biological cells to nanosecond pulsed electric fields.

    abstract::In this paper, delivery devices for nanosecond pulsed electric field exposure of biological samples in direct contact with electrodes or isolated are presented and characterized. They are based on a modified electroporation cuvette and two transverse electromagnetic cells (TEM cells). The devices were used to apply pu...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1676-0

    authors: Soueid M,Dobbelaar MCF,Bentouati S,Bardet SM,O'Connor RP,Bessières D,Paillol J,Leveque P,Arnaud-Cormos D

    更新日期:2018-01-01 00:00:00

  • 3D micro-computed tomography of trabecular and cortical bone architecture with application to a rat model of immobilisation osteoporosis.

    abstract::Bone mass and microarchitecture are the main determinants of bone strength. Three-dimensional micro-computed tomography has the potential to examine complete bones of small laboratory animals with very high resolution in a non-invasive way. In the presented work, the proximal part of the tibiae of hindlimb unloaded an...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02347054

    authors: Laib A,Barou O,Vico L,Lafage-Proust MH,Alexandre C,Rügsegger P

    更新日期:2000-05-01 00:00:00

  • Real time monitoring and analysis via the medical information bus, Part II.

    abstract::The complexity of the monitored data available in modern intensive care units suggests that they may be best processed, for presentation to medical staff, by expert system techniques. However, standard expert system shells are ill-fitted to either the basic sequential monitoring tasks of data acquisition and storage, ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02525536

    authors: Taboada JA,Arcay B,Arias JE

    更新日期:1997-09-01 00:00:00

  • Urinary bladder volume tracking using a Kalman filter.

    abstract::This study introduced the Kalman filter procedure for tracking urinary bladder filling from intermittent bladder volume measurements taken by an ultrasonic bladder volume monitor. The Kalman filter was based on a double integrator as a model for the bladder filling process between micturitions and included a procedure...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345809

    authors: Kristiansen NK,Sjöström SO,Nygaard H

    更新日期:2005-05-01 00:00:00

  • Direct nanodrug delivery for tumor targeting subject to shear-augmented diffusion in blood flow.

    abstract::The advent of multifunctional nanoparticle has enabled numerous innovative strategies in diagnostics, imaging, and cancer therapy. Despite the intense research efforts in developing new nanoparticles and surface bonding ligands, one major obstacle in achieving highly effective treatment, including minimizing detriment...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1818-z

    authors: Xu Z,Kleinstreuer C

    更新日期:2018-11-01 00:00:00

  • Assessment of a procedure for detecting minute levels of tooth erosion.

    abstract::Over a period of some years, the components of a system for discerning erosion on children's teeth have been progressively developed, for use in an extensive project seeking correlations between erosion and various perceived risk factors. The aim was the detection of minute levels of erosion, based on mappings of the ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348090

    authors: Mitchell HL,Chadwick RG,Ward S,Manton SL

    更新日期:2003-07-01 00:00:00

  • Modelling and multi-parametric control for delivery of anaesthetic agents.

    abstract::This article presents model predictive controllers (MPCs) and multi-parametric model-based controllers for delivery of anaesthetic agents. The MPC can take into account constraints on drug delivery rates and state of the patient but requires solving an optimization problem at regular time intervals. The multi-parametr...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0604-3

    authors: Dua P,Dua V,Pistikopoulos EN

    更新日期:2010-06-01 00:00:00

  • RETRACTED ARTICLE: Deep convolutional neural network-based speech enhancement to improve speech intelligibility and quality for hearing-impaired listeners.

    abstract:: ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,撤回出版物

    doi:10.1007/s11517-018-1933-x

    authors: Khaleelur Rahiman PF,Jayanthi VS,Jayanthi AN

    更新日期:2019-03-01 00:00:00