Assessment of a procedure for detecting minute levels of tooth erosion.

Abstract:

:Over a period of some years, the components of a system for discerning erosion on children's teeth have been progressively developed, for use in an extensive project seeking correlations between erosion and various perceived risk factors. The aim was the detection of minute levels of erosion, based on mappings of the palatal surfaces of the maxillary central incisors in children. Significant challenges were encountered, the primary problem being the impracticality of placing control marks that would aid the realignment of successive measurements. The paper describes the erosion detection system and initial experiences based on the results of the first 100 subjects measured after 9 months. The procedures detected the occurrence of erosion of 50 microm magnitude on about one-quarter of the teeth over the 9 month period, at a precision estimated to be +/- 15 microm. The occurrence of some anomalous incidents prevented the procedure from being fully automatic, and it necessitated human examination of a graphical diagram derived from the surface matching program, but it was nevertheless superior to current practices of examining impressions or replicas entirely by eye.

journal_name

Med Biol Eng Comput

authors

Mitchell HL,Chadwick RG,Ward S,Manton SL

doi

10.1007/BF02348090

keywords:

subject

Has Abstract

pub_date

2003-07-01 00:00:00

pages

464-9

issue

4

eissn

0140-0118

issn

1741-0444

journal_volume

41

pub_type

杂志文章
  • "Wave" as defined by wave intensity analysis.

    abstract::The propagation of waves in the arteries is generally described using Fourier analysis in terms of periodic wavetrains formed by the superposition of a mean value and sinusoidal waves at the fundamental frequency (defined by the heart rate) and its harmonics. There is, however, an alternative way to describe waves in ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0403-2

    authors: Wang JJ,Shrive NG,Parker KH,Tyberg JV

    更新日期:2009-02-01 00:00:00

  • Modelling the dynamics of expiratory airflow to describe chronic obstructive pulmonary disease.

    abstract::Chronic obstructive pulmonary disease (COPD) is characterized by expiratory airflow limitation, but current diagnostic criteria only consider flow till the first second and are therefore strongly debated. We aimed to develop a data-based individualized model for flow decline and to explore the relationship between mod...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1202-6

    authors: Topalovic M,Exadaktylos V,Decramer M,Troosters T,Berckmans D,Janssens W

    更新日期:2014-12-01 00:00:00

  • Frequency range extension of spectral analysis of pulse rate variability based on Hilbert-Huang transform.

    abstract::Heart rate variability (HRV) is a well-accepted indicator for neural regulatory mechanisms in cardiovascular circulation. Its spectrum analysis provides the powerful means of observing the modulation between sympathetic and parasympathetic nervous system. The timescale of HRV is limited by discrete beat-to-beat time i...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1135-5

    authors: Chang CC,Hsiao TC,Hsu HY

    更新日期:2014-04-01 00:00:00

  • Estimation of the dynamics of event-related desynchronisation changes in electroencephalograms.

    abstract::A method for the estimation of medium rate transitions of non-stationary electroencephalograms (EEG) is proposed. The method is applicable to such EEG dynamics that are between (a) fast transitions for which segmentation procedures are used and (b) slow transitions for which adaptive filters work properly. The estimat...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513305

    authors: Hiltunen JK,Karjalainen PA,Partanen J,Kaipio JP

    更新日期:1999-05-01 00:00:00

  • Factors affecting electrode-gel-skin interface impedance in electrical impedance tomography.

    abstract::The magnitude, mismatch and temporal variations of the electrode-gel-skin interface impedance can cause problems in electrical impedance tomography (EIT) measurement. It is shown that at the high frequencies generally encountered in EIT the capacitive properties of the electrode interface, and especially those of the ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/BF02523842

    authors: McAdams ET,Jossinet J,Lackermeier A,Risacher F

    更新日期:1996-11-01 00:00:00

  • Transesophageal left ventricular electrogram-recording and temporary pacing to improve patient selection for cardiac resynchronization.

    abstract::Cardiac resynchronization therapy (CRT) with biventricular pacing (BV) is an established therapy for heart failure (HF) patients with inter- and intraventricular conduction delay. The aim of this pilot study was to test the feasibility of both transesophageal measurement of left ventricular (LV) electrical delay and t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0767-6

    authors: Heinke M,Ismer B,Kühnert H,Figulla HR

    更新日期:2011-08-01 00:00:00

  • A catheter tactile sensor for measuring hardness of soft tissue: measurement in a silicone model and in an in vitro human prostate model.

    abstract::Tissue hardness is related to tissue composition, and this is often changed by disease. It is therefore of interest to measure the hardness in an objective and non-invasive way. A tactile sensor based on a vibrating piezoelectric ceramic element in a feedback loop is described. When the sensor touches an object it pro...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513357

    authors: Eklund A,Bergh A,Lindahl OA

    更新日期:1999-09-01 00:00:00

  • Empirical quantification of internal and external rotation muscular co-activation ratios in healthy shoulders.

    abstract::Biomechanical models used to estimate joint loads often predict that antagonistic muscles are inactive or underestimate their contributions [3, 5]. This can result in systematic underestimation of muscle force predictions and joint contact forces. To test the feasibility of employing an empirical co-activation ratio t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1081-2

    authors: Brookham RL,Dickerson CR

    更新日期:2014-03-01 00:00:00

  • Evaluating the relationship of non-phase locked activities in the electroencephalogram during intermittent stimulation: a partial coherence-based approach.

    abstract::Partial coherence estimate between two signals removing the contribution of a periodic, deterministic one is proposed for measuring the coherence between two ongoing eletroencephalografic (EEG) activities collected at distinct cortical regions under sensory stimulation. The estimator expression was derived and shown t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0191-0

    authors: Miranda de Sá AM,Infantosi AF

    更新日期:2007-07-01 00:00:00

  • Investigating body motion patterns in patients with Parkinson's disease using matching pursuit algorithm.

    abstract::Several recent studies have quantified abnormalities in Parkinsonian gait. However, few studies have attempted to quantify the regularity of body motion during walking in patients with Parkinson's disease. The aim of the paper was to characterise body motion patterns in healthy, elderly subjects and patients with Park...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02351008

    authors: Sekine M,Akay M,Tamura T,Higashi Y,Fujimoto T

    更新日期:2004-01-01 00:00:00

  • Effect of the shape and configuration of smooth muscle cells on the diffusion of ATP through the arterial wall.

    abstract::In this study, the shape and the configuration of smooth muscle cells (SMCs) within the arterial wall are altered to investigate their influence on molecular transport across the media layer of the thoracic aorta wall. In a 2D geometry of the media layer containing SMCs, the finite-element method has been employed to ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0219-5

    authors: Dabagh M,Jalali P,Sarkomaa P

    更新日期:2007-11-01 00:00:00

  • Direct nanodrug delivery for tumor targeting subject to shear-augmented diffusion in blood flow.

    abstract::The advent of multifunctional nanoparticle has enabled numerous innovative strategies in diagnostics, imaging, and cancer therapy. Despite the intense research efforts in developing new nanoparticles and surface bonding ligands, one major obstacle in achieving highly effective treatment, including minimizing detriment...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1818-z

    authors: Xu Z,Kleinstreuer C

    更新日期:2018-11-01 00:00:00

  • Automatic selection and feature extraction of motor-evoked potentials by transcranial magnetic stimulation in stroke patients.

    abstract::Transcranial magnetic stimulation (TMS) allows the assessment of stroke patients' cortical excitability and corticospinal tract integrity, which provide information regarding motor function recovery. However, the extraction of features from motor-evoked potentials (MEP) elicited by TMS, such as amplitude and latency, ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-021-02315-z

    authors: Tecuapetla-Trejo JE,Cantillo-Negrete J,Carrillo-Mora P,Valdés-Cristerna R,Ortega-Robles E,Arias-Carrion O,Carino-Escobar RI

    更新日期:2021-01-26 00:00:00

  • Mathematical model of tumor volume dynamics in mice treated with electrochemotherapy.

    abstract::The effectiveness of electrochemotherapy, a local treatment using electric pulses to increase the uptake of chemotherapeutic drug, includes several antitumor mechanisms. In addition to the cytotoxic action of chemotherapeutic drug, treatment outcome also depends on antitumor immune response. In order to assess the con...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1562-1

    authors: Forjanič T,Miklavčič D

    更新日期:2017-07-01 00:00:00

  • Structuring of service centres for economic and equipment efficiency.

    abstract::Increasing costs in healthcare have stimulated discussions on whether installation of competent in-house service groups for equipment management could eventually aid in reducing expenditure. In the Federal Republic of Germany, a four-year programme was initiated in 1979 with the purpose of investigating the feasibilit...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02442172

    authors: Irnich W

    更新日期:1989-01-01 00:00:00

  • Relation between branching patterns and perfusion in stochastic generated coronary arterial trees.

    abstract::Biological variation in branching patterns is likely to affect perfusion of tissue. To assess the fundamental consequences of branching characteristics, 50 stochastic asymmetrical coronary trees and one non-stochastic symmetrical branching tree were generated. In the stochastic trees, area growth, A, at branching poin...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0139-9

    authors: Dankelman J,Cornelissen AJ,Lagro J,Vanbavel E,Spaan JA

    更新日期:2007-01-01 00:00:00

  • Physiological quality assessment of stored whole blood by means of electrical measurements.

    abstract::The physiological parameters of blood such as extracellular Na(+), K(+), Cl(-), pH, 2,3-DPG and ATP and the complex electrical impedance were measured using whole blood samples from 31 male donors (21 donors form the training set and ten donors were used for testing), on the 0th, 10th and 21st day of blood bank storag...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0206-x

    authors: Ulgen Y,Sezdi M

    更新日期:2007-07-01 00:00:00

  • Image-based state-of-the-art techniques for the identification and classification of brain diseases: a review.

    abstract::Detection and classification methods have a vital and important role in identifying brain diseases. Timely detection and classification of brain diseases enable an accurate identification and effective management of brain impairment. Brain disorders are commonly most spreadable diseases and the diagnosing process is t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-020-02256-z

    authors: Haq EU,Huang J,Kang L,Haq HU,Zhan T

    更新日期:2020-11-01 00:00:00

  • On-line monitoring of solutes in dialysate using wavelength-dependent absorption of ultraviolet radiation.

    abstract::The aim of the study was to assess the wavelength dependence of the UV absorbance during monitoring of different compounds in the dialysate. UV absorbance was determined by using a double-beam spectrophotometer on dialysate samples taken at pre-determined times during dialysis, over a wavelength range of 180-380 nm. C...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348430

    authors: Fridolin I,Lindberg LG

    更新日期:2003-05-01 00:00:00

  • Monopole patch antenna for in vivo exposure to nanosecond pulsed electric fields.

    abstract::To explore the promising therapeutic applications of short nanosecond electric pulses, in vitro and in vivo experiments are highly required. In this paper, an exposure system based on monopole patch antenna is reported to perform in vivo experiments on newborn mice with both monopolar and bipolar nanosecond signals. A...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1547-0

    authors: Merla C,Apollonio F,Paffi A,Marino C,Vernier PT,Liberti M

    更新日期:2017-07-01 00:00:00

  • Discrimination of stroke-related mild cognitive impairment and vascular dementia using EEG signal analysis.

    abstract::Stroke survivors are more prone to developing cognitive impairment and dementia. Dementia detection is a challenge for supporting personalized healthcare. This study analyzes the electroencephalogram (EEG) background activity of 5 vascular dementia (VaD) patients, 15 stroke-related patients with mild cognitive impairm...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1734-7

    authors: Al-Qazzaz NK,Ali SHBM,Ahmad SA,Islam MS,Escudero J

    更新日期:2018-01-01 00:00:00

  • A unified canonical correlation analysis-based framework for removing gradient artifact in concurrent EEG/fMRI recording and motion artifact in walking recording from EEG signal.

    abstract::Artifacts cause distortion and fuzziness in electroencephalographic (EEG) signal and hamper EEG analysis, so it is necessary to remove them prior to the analysis. Particularly, artifact removal becomes a critical issue in experimental protocols with significant inherent recording noise, such as mobile EEG recordings a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1620-3

    authors: Li J,Chen Y,Taya F,Lim J,Wong K,Sun Y,Bezerianos A

    更新日期:2017-09-01 00:00:00

  • Refixation stability in shoulder hemiarthroplasty in case of four-part proximal humeral fracture.

    abstract::Primary stability of refixated fractures in case of shoulder hemiarthroplasty is a prerequisite to restore physiological glenohumeral joint function. Clinical observations often show a secondary dislocation and subsequent resorption of the bony anchor points like the greater and lesser tuberosity at the rotator cuff t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0483-7

    authors: Baumgartner D,Lorenzetti SR,Mathys R,Gasser B,Stüssi E

    更新日期:2009-05-01 00:00:00

  • Fast GPU-based computation of spatial multigrid multiframe LMEM for PET.

    abstract::Significant efforts were invested during the last decade to accelerate PET list-mode reconstructions, notably with GPU devices. However, the computation time per event is still relatively long, and the list-mode efficiency on the GPU is well below the histogram-mode efficiency. Since list-mode data are not arranged in...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1284-9

    authors: Nassiri MA,Carrier JF,Després P

    更新日期:2015-09-01 00:00:00

  • MicroPACS: a PC-based small PACS implementation.

    abstract::To make picture archiving and communication systems (PACS) a practical reality for small-scale structures, it appears necessary to build a network that integrates and optimises production management, analysis and storage of images, and to include the ability to communicate with other similar remote structures. To solv...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02458046

    authors: Duchêne J,Lerallut JF,Gong N,Kanz R

    更新日期:1993-05-01 00:00:00

  • Dynamics of magnetic particles in cylindrical Halbach array: implications for magnetic cell separation and drug targeting.

    abstract::Magnetic nanoparticles for therapy and diagnosis are at the leading edge of the rapidly developing field of bionanotechnology. In this study, we have theoretically studied motion of magnetic nano- as well as micro-particles in the field of cylindrical Halbach array of permanent magnets. Magnetic flux density was model...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0636-8

    authors: Babinec P,Krafcík A,Babincová M,Rosenecker J

    更新日期:2010-08-01 00:00:00

  • Inertial measurement units furnish accurate trunk trajectory reconstruction of the sit-to-stand manoeuvre in healthy subjects.

    abstract::A simple inertial measurement unit (IMU) incorporating rate gyroscopes and accelerometers has been tested to investigate the trunk kinematics during the sit-to-stand. It was affixed at trunk L5 level and used for sit-to-stand position and orientation reconstruction. The method was validated with standard optoelectroni...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0224-8

    authors: Giansanti D,Maccioni G,Benvenuti F,Macellari V

    更新日期:2007-10-01 00:00:00

  • A machine learning approach for magnetic resonance image-based mouse brain modeling and fast computation in controlled cortical impact.

    abstract::Computational modeling of the brain is crucial for the study of traumatic brain injury. An anatomically accurate model with refined details could provide the most accurate computational results. However, computational models with fine mesh details could take prolonged computation time that impedes the clinical transla...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02262-1

    authors: Lai C,Chen Y,Wang T,Liu J,Wang Q,Du Y,Feng Y

    更新日期:2020-11-01 00:00:00

  • A multi-electrode array and inversion technique for retrieving six conductivities from heart potential measurements.

    abstract::A method for accurately finding cardiac bidomain conductivity parameters is a crucial part of efforts to study and understand the electrical functioning of the heart. The bidomain model considers current flowing along (longitudinal) and across (transverse) sheets of cardiac fibres, as well as between these sheets (nor...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1101-2

    authors: Johnston BM,Johnston PR

    更新日期:2013-12-01 00:00:00

  • Continuous remote monitoring of COPD patients-justification and explanation of the requirements and a survey of the available technologies.

    abstract::Remote patient monitoring should reduce mortality rates, improve care, and reduce costs. We present an overview of the available technologies for the remote monitoring of chronic obstructive pulmonary disease (COPD) patients, together with the most important medical information regarding COPD in a language that is ada...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-018-1798-z

    authors: Tomasic I,Tomasic N,Trobec R,Krpan M,Kelava T

    更新日期:2018-04-01 00:00:00