Mechanisms governing the visco-elastic responses of living cells assessed by foam and tensegrity models.

Abstract:

:The visco-elastic properties of living cells, measured to date by various authors, vary considerably, depending on the experimental methods and/or on the theoretical models used. In the present study, two mechanisms thought to be involved in cellular visco-elastic responses were analysed, based on the idea that the cytoskeleton plays a fundamental role in cellular mechanical responses. For this purpose, the predictions of an open unit-cell model and a 30-element visco-elastic tensegrity model were tested, taking into consideration similar properties of the constitutive F-actin. The quantitative predictions of the time constant and viscosity modulus obtained by both models were compared with previously published experimental data obtained from living cells. The small viscosity modulus values (10(0)-10(3) Pa x s) predicted by the tensegrity model may reflect the combined contributions of the spatially rearranged constitutive filaments and the internal tension to the overall cytoskeleton response to external loading. In contrast, the high viscosity modulus values (10(3)-10(5) Pa x s) predicted by the unit-cell model may rather reflect the mechanical response of the cytoskeleton to the bending of the constitutive filaments and/or to the deformation of internal components. The present results suggest the existence of a close link between the overall visco-elastic response of micromanipulated cells and the underlying architecture.

journal_name

Med Biol Eng Comput

authors

Cañadas P,Laurent VM,Chabrand P,Isabey D,Wendling-Mansuy S

doi

10.1007/BF02349982

keywords:

subject

Has Abstract

pub_date

2003-11-01 00:00:00

pages

733-9

issue

6

eissn

0140-0118

issn

1741-0444

journal_volume

41

pub_type

杂志文章
  • Modelling and multi-parametric control for delivery of anaesthetic agents.

    abstract::This article presents model predictive controllers (MPCs) and multi-parametric model-based controllers for delivery of anaesthetic agents. The MPC can take into account constraints on drug delivery rates and state of the patient but requires solving an optimization problem at regular time intervals. The multi-parametr...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0604-3

    authors: Dua P,Dua V,Pistikopoulos EN

    更新日期:2010-06-01 00:00:00

  • Physiological quality assessment of stored whole blood by means of electrical measurements.

    abstract::The physiological parameters of blood such as extracellular Na(+), K(+), Cl(-), pH, 2,3-DPG and ATP and the complex electrical impedance were measured using whole blood samples from 31 male donors (21 donors form the training set and ten donors were used for testing), on the 0th, 10th and 21st day of blood bank storag...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0206-x

    authors: Ulgen Y,Sezdi M

    更新日期:2007-07-01 00:00:00

  • Real time monitoring and analysis via the medical information bus, Part II.

    abstract::The complexity of the monitored data available in modern intensive care units suggests that they may be best processed, for presentation to medical staff, by expert system techniques. However, standard expert system shells are ill-fitted to either the basic sequential monitoring tasks of data acquisition and storage, ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02525536

    authors: Taboada JA,Arcay B,Arias JE

    更新日期:1997-09-01 00:00:00

  • Interaction between steady flow and individualised compliant segments: application to upper airways.

    abstract::To describe upper airway obstruction in patients with sleep apnea syndrome, the steady state solutions of a simple model of local pharyngeal obstruction were studied. Importantly, the present model embodies a series of two individualised elements, each having its own compliance, which enables the consideration, from a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510972

    authors: Fodil R,Ribreau C,Louis B,Lofaso F,Isabey D

    更新日期:1997-11-01 00:00:00

  • Delivery devices for exposure of biological cells to nanosecond pulsed electric fields.

    abstract::In this paper, delivery devices for nanosecond pulsed electric field exposure of biological samples in direct contact with electrodes or isolated are presented and characterized. They are based on a modified electroporation cuvette and two transverse electromagnetic cells (TEM cells). The devices were used to apply pu...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1676-0

    authors: Soueid M,Dobbelaar MCF,Bentouati S,Bardet SM,O'Connor RP,Bessières D,Paillol J,Leveque P,Arnaud-Cormos D

    更新日期:2018-01-01 00:00:00

  • Experimental and numerical investigation on soft tissue dynamic response due to turbulence-induced arterial vibration.

    abstract::Peripheral arterial occlusive disease is a serious cardiovascular disorder. The arterial occlusion leads to turbulent flow and arterial sound generation on the inner vessel wall. Stenosis-induced vibro-acoustic waves propagate through the surrounding soft tissues and reach the skin surface. In this study, the feasibil...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01995-y

    authors: Salman HE,Yazicioglu Y

    更新日期:2019-08-01 00:00:00

  • Multiscale entropy-based approach to automated surface EMG classification of neuromuscular disorders.

    abstract::We introduce a novel method for an automatic classification of subjects to those with or without neuromuscular disorders. This method is based on multiscale entropy of recorded surface electromyograms (sEMGs) and support vector classification. The method was evaluated on a single-channel experimental sEMGs recorded fr...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0629-7

    authors: Istenic R,Kaplanis PA,Pattichis CS,Zazula D

    更新日期:2010-08-01 00:00:00

  • Biomechanical analysis of structural deformation in living cells.

    abstract::Most tissues are subject to some form of physiological mechanical loading which results in deformation of the cells triggering intracellular mechanotransduction pathways. This response to loading is generally essential for the health of the tissue, although more pronounced deformation may result in cell and tissue dam...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-008-0381-4

    authors: Bader DL,Knight MM

    更新日期:2008-10-01 00:00:00

  • A fully automated hybrid human sperm detection and classification system based on mobile-net and the performance comparison with conventional methods.

    abstract::Sperm morphology, as an indicator of fertility, is a critical tool in semen analysis. In this study, a smartphone-based hybrid system that fully automates the sperm morphological analysis is introduced with the aim of eliminating unwanted human factors. Proposed hybrid system consists of two progressive steps: automat...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02101-y

    authors: Ilhan HO,Sigirci IO,Serbes G,Aydin N

    更新日期:2020-05-01 00:00:00

  • Clinically oriented real-time monitoring of the individual's risk for deep tissue injury.

    abstract::Spinal cord injury patients are under daily risk for developing deep tissue injury which is a severe pressure ulcer that initiates in soft tissues at the bones' proximity. We aimed to formulate a patient-specific biomechanical model that can continuously monitor internal tissue stresses in real time. We adopted a form...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0754-y

    authors: Portnoy S,Vuillerme N,Payan Y,Gefen A

    更新日期:2011-04-01 00:00:00

  • Time-varying digital filtering of ECG baseline wander.

    abstract::Time-varying filtering techniques are applied to the problem of baseline correction by letting the cut-off frequency of a linear filter be controlled by the low-frequency properties of the ECG signal. The time-varying filter is implemented as a bank of linear low-pass filters, in which each filter has a slightly diffe...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441986

    authors: Sörnmo L

    更新日期:1993-09-01 00:00:00

  • Combined compression and elongation experiments and non-linear modelling of liver tissue for surgical simulation.

    abstract::Uniaxial stress-strain data were obtained from in vitro experiments on 20 porcine livers for compressions, elongations and cycles of compression and then elongation. There were about 70 cylindrical samples, with diameter 7mm and varying height (4-11 mm). The combined compression and elongation test provide a unified f...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345212

    authors: Chui C,Kobayashi E,Chen X,Hisada T,Sakuma I

    更新日期:2004-11-01 00:00:00

  • Dielectric properties of bones for the monitoring of osteoporosis.

    abstract::Osteoporosis is one of the most common diseases that leads to bone fractures. Dual-energy X-ray absorptiometry is currently employed to measure the bone mineral density and to diagnose osteoporosis. Alternatively, the dielectric properties of bones are found to be influenced by bone mineral density; hence, dielectric ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-018-1887-z

    authors: Amin B,Elahi MA,Shahzad A,Porter E,McDermott B,O'Halloran M

    更新日期:2019-01-01 00:00:00

  • Numerical simulation of instantaneous backflow through central clearance of bileaflet mechanical heart valves at closure: shear stress and pressure fields within clearance.

    abstract::Instantaneous backflow through central clearance of bileaflet heart valves at the instant of closure is investigated. An Edwards-Duromedics valve in the mitral position is employed to measure the transient pressures near the entrance and exit region in an in vitro flow chamber. A region surrounding the clearance is mo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510497

    authors: Lee CS,Chandran KB

    更新日期:1995-05-01 00:00:00

  • Hybrid stent device of flow-diverting effect and stent-assisted coil embolization formed by fractal structure.

    abstract::This paper presents a novel hybrid medical stent device. This hybrid stent device formed by fractal mesh structures provides a flow-diverting effect and stent-assisted coil embolization. Flow-diverter stents decrease blood flow into an aneurysm to prevent its rupture. In general, the mesh size of a flow-diverter stent...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1374-8

    authors: Kojima M,Irie K,Masunaga K,Sakai Y,Nakajima M,Takeuchi M,Fukuda T,Arai F,Negoro M

    更新日期:2016-05-01 00:00:00

  • Modelling and numerical simulation of the in vivo mechanical response of the ascending aortic aneurysm in Marfan syndrome.

    abstract::Marfan syndrome (MFS) is a genetic disorder that affects connective tissue, impairing cardiovascular structures and function, such as heart valves and aorta. Thus, patients with Marfan disease have a higher risk of developing circulatory problems associated with mitral and aortic valves prolapse, manifested as dilated...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1524-7

    authors: García-Herrera CM,Celentano DJ,Herrera EA

    更新日期:2017-03-01 00:00:00

  • Monopole patch antenna for in vivo exposure to nanosecond pulsed electric fields.

    abstract::To explore the promising therapeutic applications of short nanosecond electric pulses, in vitro and in vivo experiments are highly required. In this paper, an exposure system based on monopole patch antenna is reported to perform in vivo experiments on newborn mice with both monopolar and bipolar nanosecond signals. A...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1547-0

    authors: Merla C,Apollonio F,Paffi A,Marino C,Vernier PT,Liberti M

    更新日期:2017-07-01 00:00:00

  • Recording fetal breathing movements with a passive transducer based on an inductive principle.

    abstract::A new transducer has been developed, based on an inductive principle, for recording fetal movements and sounds. The compliance of this transducer, the INductive PHOno-sensor (INPHO), can be matched to that of the maternal abdomen to provide an optimal transfer of displacement between maternal abdomen and transducer. I...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441655

    authors: Goovaerts HG,van Geijn HP,Rompelman O,Mantel R,Swartjes JM

    更新日期:1991-07-01 00:00:00

  • The formation of extracellular potentials over the innervation zone: Are these potentials affected by changes in fibre membrane properties?

    abstract::Widespread misconceptions still exist regarding the formation of extracellular potentials over the innervation zone: the assumption (1) that the first phase of these potentials mainly reflects the process of initiation of the intracellular action potential (IAP) at the neuromuscular junction and that (2) these potenti...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1487-8

    authors: Rodriguez-Falces J

    更新日期:2016-12-01 00:00:00

  • Analysis of implantable cardioverter defibrillator signals for non conventional cardiac electrical activity characterization.

    abstract::Implantable cardioverter defibrillators (ICDs) can store intracardiac electrograms (EGMs) in sinus rhythm (SR), at the onset of spontaneous ventricular tachyarrhythmias (VT) or during their course. This allows the investigation of unknown features of the heart electrical activity associated with different cardiac rhyt...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-005-0014-0

    authors: Casaleggio A,Rossi P,Faini A,Guidotto T,Malavasi V,Musso G,Sartori G

    更新日期:2006-03-01 00:00:00

  • Resolving superimposed motor unit action potentials.

    abstract::A new algorithm to resolve superimposed motor unit action potentials (MUAPs) is described, which uses a reduced search space and is based on the peel off approach. Knowledge specific to the problem domain, such as temporal relationships between and within motor unit action potential trains and MUAP energy information,...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02637020

    authors: Etawil H,Stashuk D

    更新日期:1996-01-01 00:00:00

  • Ictal and peri-ictal changes in cervical vagus nerve activity associated with cardiac effects.

    abstract::The vagus nerves convey both afferent and efferent information about autonomic activity related to cardiovascular functions. Those functions have been shown to change due to epileptic seizures, which suggests that ictal events might be detected via the vagus electroneurogram (VENG). In this study, we characterize the ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0782-7

    authors: Harreby KR,Sevcencu C,Struijk JJ

    更新日期:2011-09-01 00:00:00

  • Power type strain energy function model and prediction of the anisotropic mechanical properties of skin using uniaxial extension data.

    abstract::Many successful models to describe the biomechanical characteristics of planar biological soft tissues are based on strain energy function. However, the parameters in these models are determined by biaxial extension test, which might be difficult to exercise for certain types of soft tissue. This study presents a new ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1098-6

    authors: Li L,Qian X,Wang H,Hua L,Zhang H,Liu Z

    更新日期:2013-10-01 00:00:00

  • Numerical assessment of bone remodeling around conventionally and early loaded titanium and titanium-zirconium alloy dental implants.

    abstract::The aim of this study was to investigate conventionally and early loaded titanium and titanium-zirconium alloy implants by three-dimensional finite element stress analysis. Three-dimensional model of a dental implant was created and a thread area was established as a region of interest in trabecular bone to study a lo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1256-0

    authors: Akça K,Eser A,Çavuşoğlu Y,Sağırkaya E,Çehreli MC

    更新日期:2015-05-01 00:00:00

  • Computational prediction of the effect of D172N KCNJ2 mutation on ventricular pumping during sinus rhythm and reentry.

    abstract::The understanding of cardiac arrhythmia under genetic mutations has grown in interest among researchers. Previous studies focused on the effect of the D172N mutation on electrophysiological behavior. In this study, we analyzed not only the electrophysiological activity but also the mechanical responses during normal s...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02124-w

    authors: Heikhmakhtiar AK,Lee CH,Song KS,Lim KM

    更新日期:2020-05-01 00:00:00

  • Left-ventricular pressure gradients: a computer-model simulation.

    abstract::Both invasive left-ventricular pressure measurements and non-invasive colour M-mode echographic measurements have shown the existence of intraventricular pressure gradients (IVPGs) during early filling. The mechanisms responsible for these IVPG cannot be completely explained by the experiments. Therefore a one-dimensi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513338

    authors: Verdonck P,Vierendeels J,Riemslagh K,Dick E

    更新日期:1999-07-01 00:00:00

  • Heart rate and body temperature sensitive diaphragm pacing.

    abstract::Two ways of rate control for diaphragm pacing are proposed. One is rate control using only the patients' body temperature (method I). The other is rate control by both the patients' heart rate and body temperature (method II). To test the effectiveness of these methods, a diaphragm pacemaker which can be controlled by...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446125

    authors: Kimura M,Sugiura T,Fukui Y,Kimura T,Harada Y

    更新日期:1992-03-01 00:00:00

  • Effect of signal length on the performance of independent component analysis when extracting the lambda wave.

    abstract::The aim of the study was to investigate the effect of signal length on the performance of a signal source separation method, independent component analysis (ICA), when extracting the visual evoked potential (EP) lambda wave from saccade-related electro-encephalogram (EEG) waveforms. A method was devised that enabled t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348134

    authors: Vigon L,Saatchi R,Mayhew JE,Taroyan NA,Frisby JP

    更新日期:2002-03-01 00:00:00

  • Fast body part segmentation and tracking of neonatal video data using deep learning.

    abstract::Photoplethysmography imaging (PPGI) for non-contact monitoring of preterm infants in the neonatal intensive care unit (NICU) is a promising technology, as it could reduce medical adhesive-related skin injuries and associated complications. For practical implementations of PPGI, a region of interest has to be detected ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02251-4

    authors: Antink CH,Ferreira JCM,Paul M,Lyra S,Heimann K,Karthik S,Joseph J,Jayaraman K,Orlikowsky T,Sivaprakasam M,Leonhardt S

    更新日期:2020-12-01 00:00:00

  • Investigating body motion patterns in patients with Parkinson's disease using matching pursuit algorithm.

    abstract::Several recent studies have quantified abnormalities in Parkinsonian gait. However, few studies have attempted to quantify the regularity of body motion during walking in patients with Parkinson's disease. The aim of the paper was to characterise body motion patterns in healthy, elderly subjects and patients with Park...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02351008

    authors: Sekine M,Akay M,Tamura T,Higashi Y,Fujimoto T

    更新日期:2004-01-01 00:00:00